The aim of the study was to apply 3D measurements for fracture displacement in minimally to moderately displaced acetabular fractures treated nonoperatively, and to evaluate whether this measurement can be used to estimate the likelihood of conversion to total hip arthroplasty (THA) at follow-up. A multicentre, cross-sectional study was performed on 144 patients who were treated nonoperatively for an acetabular fracture in four level 1 trauma centres between January 2000 and December 2020. For each patient, fracture displacement was measured on CT-based 3D models. The 3D gap area represents fracture displacement (mm2) between all fracture fragments. A receiver operating characteristic curve was generated to determine a 3D gap area threshold representing the optimal sensitivity and specificity to predict conversion to THA. Native hip survival was reported using Kaplan-Meier curves. Predictors of conversion to THA were determined using Cox regression analysis.Aims
Methods
Aims. Complex elbow fracture-dislocations often result in suboptimal outcomes and necessitate a thorough understanding of injury patterns to guide effective management and reduce adverse sequelae. The Wrightington Classification System (WCS) offers a comprehensive approach and considers both bony and soft-tissue disruption, providing clearer guidance for treatment. This is the first external study to assess the reliability of the WCS for elbow fracture-dislocations. Methods. A blinded study of patients with elbow fracture-dislocations at a single institution between December 2014 and December 2022 was conducted. Five assessors with a range of experience, including orthopaedic surgeons and radiologists, independently classified injuries using the WCS across three image methods: plain radiograph,
This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder. A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Aims
Methods
Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC).Aims
Methods
This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons? A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.Aims
Methods
Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed.Aims
Methods
The amount of glenoid bone loss is an important factor in deciding between soft-tissue and bony reconstruction when managing anterior shoulder instability. Accurate and reproducible measurement of glenoid bone loss is therefore vital in evaluation of shoulder instability and recommending specific treatment. The aim of this systematic review is to identify the range methods and measurement techniques employed in clinical studies treating glenoid bone loss. A systematic review of the PubMed, MEDLINE, and Embase databases was undertaken to cover a ten-year period from February 2011 to February 2021. We identified clinical studies that incorporated bone loss assessment in the methodology as part of the decision-making in the management of patients with anterior shoulder instability. The Preferred Reporting Items for Systematic Reviews (PRISMA) were used.Aims
Methods
Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether
Aims. The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. Methods. This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven observers reviewed preoperative radiographs and CT scans twice, with a minimum four-week interval. Radiographs and CT scans were reviewed separately. Inter- and intraobserver reliability were calculated using Fleiss and Cohen kappa coefficients. The Landis and Koch criteria were used to interpret the strength of the kappa values. Validity was assessed by calculating the percentage agreement against intraoperative findings. Results. Of the 48 patients, three (6%) had type A injury, 11 (23%) type B, 16 (33%) type B+, 16 (33%) Type C, two (4%) type D+, and none had a type D injury. All 48 patients had anteroposterior (AP) and lateral radiographs, 44 had
Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning. A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.Aims
Methods
Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired Aims
Methods
Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
Introduction. The degree of glenoid bone loss associated with primary glenohumeral osteoarthritis can influence the type of glenoid implant selected and its placement in total shoulder arthroplasty (TSA). The literature has demonstrated inaccurate glenoid component placement when using standard instruments and two-dimensional (2D) imaging without templating, particularly as the degree of glenoid deformity or bone loss worsens. Published results have demonstrated improved accuracy of implant placement when using three-dimensional (3D) computed tomography (CT) imaging with implant templating and patient specific instrumentation (PSI). Accurate placement of the glenoid component in TSA is expected to decrease component malposition and better correct pathologic deformity in order to decrease the risk of component loosening and failure over time. Different types of PSI have been described. Some PSI use 3D printed single use disposable instrumentation, while others use adjustable and reusable-patient specific instrumentation (R-PSI). However, no studies have directly compared the accuracy of different types of PSI in shoulder arthroplasty. We combined our clinical experience and compare the accuracy of glenoid implant placement with five different types of instrumentation when using 3D CT imaging, preoperative planning and implant templating in a series of 173 patients undergoing primary TSA. Our hypothesis was that all PSI technologies would demonstrate equivalent accuracy of implant placement and that PSI would show the most benefit with more severe glenoid deformity. Discussion and Conclusions. We demonstrated no consistent differences in accuracy of 3D CT preoperative planning and templating with any type of PSI used. In Groups 1 and 2, standard instrumentation was used in a patient specific manner defined by the software and in Groups 3, 4, and 5 a patient specific instrument was used. In all groups, the two surgeons were very experienced with use of the 3D CT preoperative planning and templating software and all of the instrumentation prior to starting this study, as well as very experienced with shoulder arthroplasty. This is a strength of the study when defining the efficacy of the technology, but limits the generalizability of the findings when considering the effectiveness of the technology with surgeons that may not have as much experience with shoulder arthroplasty and/or the PSI technology. Conversely, it could be postulated that greater improvements in accuracy may be seen with the studied PSI technology, when compared to no 3D planning or PSI, with less experienced surgeons. There could also be differences between the PSI technologies when used by less experienced surgeons, either across all cases or based upon the severity of pathology. When the surgeon is part of the method, the effectiveness of the technology is equally dependent upon the surgeon using the technology. A broader study using different surgeons is required to test the effectiveness of this technology. Comparing the results of this study with published results in the literature, 3D CT imaging and implant templating with use of PSI results in more accurate placement of the glenoid implant when compared to
An adult acquired flatfoot deformity (AAFD) is a complex 3D deformity. Surgical correction consists of a medial calcaneal osteotomy (MCO) but shows limitations due to the current 2D assessment. Therefore, the aim is to determine the influence of an MCO on the longitudinal foot arch assessed by 2D and 3D weightbearing CT (WBCT). Seventeen patients with a mean age of 44,5 years (range 18–66 yrs) were retrospectively included. MCO was indicated in a stage II AAFD (N=15) and a post-traumatic valgus deformity (N=2). Pre- and post-operative imaging was obtained from a WBCT. The height of the longitudinal foot arch was measured as the distance from the navicular tuberositas to the floor (Navicular Height, NH) on
We aimed to retrospectively assess the accuracy and safety of
CT navigated pedicle screws and to compare accuracy in the cervical
and thoracic spine (C2-T8) with (COMB) and without (POST) prior
anterior surgery (anterior cervical discectomy or corpectomy and
fusion with ventral plating: ACDF/ACCF). A total of 592 pedicle screws, which were used in 107 consecutively
operated patients (210 COMB, 382 POST), were analysed. The accuracy
of positioning was determined according to the classification of
Gertzbein and Robbins on post-operative CT scans.Aims
Patients and Methods
Background. Radiological and clinical results of total shoulder arthroplasty are dependent upon ability to accurately measure and correct glenoid version. There are a variety of imaging modalities and computer-assisted reconstruction programmes that are employed with varying degrees of success. We have compared three freely available modalities: unformatted
Background. Humeral version is the twist angle of the humeral head relative to the distal humerus. Pre-operatively, it is most commonly measured referencing the transepicondylar axis, although various techniques are described in literature (Matsumura et al. 2014, Edelson 1999, Boileau et al., 2008). Accurate estimation of the version angle is important for humeral head osteotomy in preparation for shoulder arthroplasty, as deviations from native version can result in prosthesis malalignment. Most humeral head osteotomy guides instruct the surgeon to reference the ulnar axis with the elbow flexed at 90°. Average version values have been reported at 17.6° relative to the transepicondylar axis and 28.8° relative to the ulnar axis (Hernigou, Duparc, and Hernigou 2014), although it is highly variable and has been reported to range from 10° to 55° (Pearl and Volk 1999). These studies used
Background. Dislocation is a common complication after proximal and total femur prosthesis reconstruction for primary bone sarcoma patients. Expandable prosthesis in children puts an additional challenge due to the lengthening process. Hip stability is impaired due to multiple factors: Resection of the hip stabilizers as part of the sarcoma resection: forces acts on the hip during the lengthening; and mismatch of native growing acetabulum to the metal femoral head. Surgical solutions described in literature are various with reported low rates of success. Objective. Assess a novel 3D surgical planning technology by use of 3D models (computerized and physical), 3D planning, and Patient Specific Instruments (PSI) in supporting correction of young children suffering from hip instability after expandable prosthesis reconstruction following proximal femur resection. This innovative technology creates a new dimension of visualization and customization, and could improve understanding of this complex problem and facilitate the surgical decision making and procedure. Method. Two children, both patients with Ewing Sarcoma of the left proximal femur stage-IIB, ages 3/5 years at diagnosis, were treated with conventional chemotherapy followed by proximal femur resection. Both were reconstructed with expandable prosthesis (one at resection and other 4 years after resection). Hip migration developed gradually during lengthening process in the 24m follow up period. 3D software (Mimics, Materialise, Belgium) were used to make computerized 3D models of patients' pelvises. These were used to 3D print 1:1 physical models. Custom 3D planning software (MSk Lab, Imperial College London) allowed surgeons visualizing the anatomical status and assess of problem severity. Thereafter, osteotomies planes and the desired position of acetabular roof after reduction of hip joint were planned by the surgeons. These plans were used to generate 3D printed PSIs to guide the osteotomies during shelf and triple osteotomy surgeries. Accuracy of planning and PSIs were verified with fluoroscopy and post-op X-rays, by comparing cutting planes and post-op position of the acetabulum. Results. Surgeons reported excellent experience with the 3D models (computerized and physical). It helped them in the decision process with an improved understanding of the relationship between prosthesis head and acetabulum, a clear view of the osteophytes and bone formation surrounding the pseudoacetabulum, and osteophytes inside the native acetabulum. These osteophytes were not immediately visible on
Assessing glenoid version is important for a successful total shoulder arthroplasty. Glenoid version is defined as the orientation of the glenoid cavity in relation to a plane perpendicular to the scapula body. Glenoid revision averages between 1 to 2 degrees of retroversion and varies between race and sex. In general glenoid retroversion is overestimated by 6.5 degrees on plain radiographs. Furthermore standard axial