Advertisement for orthosearch.org.uk
Results 1 - 20 of 52
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 18 - 18
12 Dec 2024
Rai A Nanda R Ponugoti N Saunders M
Full Access

Objectives. Distal humerus fractures in elderly population are often comminuted and presents multiple challenges. When managed with fixation the results are often complicated with stiffness, pain, and reduced function while total elbow replacement is fraught with lifelong restrictions on load bearing which can significantly affect elderly patients who rely assistive devices for ambulation. Elbow hemiarthroplasty however, presents a viable alternative in these cases. This series evaluates the results of the distal humerus hemiarthroplasty in a single centre. Designs and methods. Data was collected retrospectively. Comprehensive case reviews were done to collect demographic, intra-operative and post-operative data. Fractures were classified as per AO classification. The primary outcome was functional outcome and range of motion (ROM). The secondary outcomes were complications and patient satisfaction. Results. 22 cases were included in this study from 2016 – 2023 majority being females (n=18). Mean age was 74years (SD −11.2). Majority fractures were AO type C3 (n=15) with two A2 type fractures managed for non-union. Pre-existing bone on bone arthritis was present in 3 cases and CT scan was done for 12 patients to assess fracture configuration. Excluding those treated for non- union the median time between fracture and surgery was 8.5 days. Follow-up of more than 6 months was available for 16 patients with median follow-up of 18 months. ROM was available for 17 patients with 13 (50%) patients having functional ROM. No patients had full extension and there was a mean lag of 20. 0. Mean flexion was 118.2. 0. Nearly 2/3. rd. patients (73%- n=16) were satisfied with the surgery with no problems in activity of daily living. Complications seen were ulnar neuropathy (n=3), heterotopic ossification(n=2) and periprosthetic fracture (n=1). Conclusion. This single centre study suggests good outcomes following distal humerus hemiarthroplasty. It is a reasonable alternative to fixation and total elbow arthroplasty in complex fractures


Bone & Joint 360
Vol. 13, Issue 2 | Pages 41 - 44
1 Apr 2024

The April 2024 Children’s orthopaedics Roundup360 looks at: Ultrasonography or radiography for suspected paediatric distal forearm fractures?; Implant density in scoliosis: an important variable?; Gait after paediatric femoral shaft fracture treated with intramedullary nail fixation: a longitudinal prospective study; The opioid dilemma: navigating pain management for children’s bone fractures; 12- to 20-year follow-up of Dega acetabuloplasty in patients with developmental dysplasia of the hip; Physeal fractures of the distal ulna: incidence and risk factors for premature growth arrest; Analysis of growth after transphyseal anterior cruciate ligament reconstruction in children; Management of lateral condyle humeral fracture associated with elbow dislocation in children: a retrospective international multicentre cohort study.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 22 - 22
17 Apr 2023
Murugesu K Decruz J Jayakumar R
Full Access

Standard fixation for intra-articular distal humerus fracture is open reduction and internal fixation (ORIF). However, high energy fractures of the distal humerus are often accompanied with soft tissue injuries and or vascular injuries which limits the use of internal fixation. In our report, we describe a highly complex distal humerus fracture that showed promising healing via a ring external fixator. A 26-year-old man sustained a Gustillo Anderson Grade IIIB intra-articular distal humerus fracture of the non-dominant limb with bone loss at the lateral column. The injury was managed with aggressive wound debridement and cross elbow stabilization via a hinged ring external fixator. Post operative wound managed with foam dressing. Post-operatively, early controlled mobilization of elbow commenced. Fracture union achieved by 9 weeks and frame removed once fracture united. No surgical site infection or non-union observed throughout follow up. At 2 years follow up, flexion - extension of elbow is 20°- 100°, forearm supination 65°, forearm pronation 60° with no significant valgus or varus deformity. The extent of normal anatomic restoration in elbow fracture fixation determines the quality of elbow function with most common complication being elbow stiffness. Ring fixator is a non-invasive external device which provides firm stabilization of fracture while allowing for adequate soft tissue management. It provides continuous axial micro-movements in the frame which promotes callus formation while avoiding translation or angulation between the fragments. In appropriate frame design, they allow for early rehabilitation of joint where normal range of motion can be allowed in controlled manner immediately post-fixation. Functional outcome of elbow fracture from ring external fixation is comparable to ORIF due to better rehabilitation and lower complications. Ring external fixator in our patient achieved acceptable functional outcome and fracture alignment meanwhile the fracture was not complicated with common complications seen in ORIF. In conclusion, ring external fixator is as effective as ORIF in treating complex distal humeral fractures and should be considered for definitive fixation in such fractures


Bone & Joint 360
Vol. 12, Issue 2 | Pages 28 - 31
1 Apr 2023

The April 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic Bankart repair in athletes: in it for the long run?; Functional outcomes and the Wrightington classification of elbow fracture-dislocations; Hemiarthroplasty or ORIF intra-articular distal humerus fractures in older patients; Return to sport after total shoulder arthroplasty and hemiarthroplasty; Readmissions after shoulder arthroplasty; Arthroscopic Bankart repair in the longer term; Bankart repair with(out) remplissage or the Latarjet procedure? A systematic review and meta-analysis; Regaining motion among patients with shoulder pathology: are all exercises equal?


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


Bone & Joint Research
Vol. 11, Issue 11 | Pages 814 - 825
14 Nov 2022
Ponkilainen V Kuitunen I Liukkonen R Vaajala M Reito A Uimonen M

Aims

The aim of this systematic review and meta-analysis was to gather epidemiological information on selected musculoskeletal injuries and to provide pooled injury-specific incidence rates.

Methods

PubMed (National Library of Medicine) and Scopus (Elsevier) databases were searched. Articles were eligible for inclusion if they reported incidence rate (or count with population at risk), contained data on adult population, and were written in English language. The number of cases and population at risk were collected, and the pooled incidence rates (per 100,000 person-years) with 95% confidence intervals (CIs) were calculated by using either a fixed or random effects model.


Bone & Joint 360
Vol. 11, Issue 4 | Pages 25 - 29
1 Aug 2022


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 963 - 971
1 Aug 2022
Sun Z Liu W Liu H Li J Hu Y Tu B Wang W Fan C

Aims

Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries.

Methods

This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 29 - 32
1 Jun 2022


Bone & Joint 360
Vol. 11, Issue 2 | Pages 31 - 34
1 Apr 2022


Bone & Joint 360
Vol. 10, Issue 4 | Pages 31 - 34
1 Aug 2021


Bone & Joint 360
Vol. 10, Issue 3 | Pages 20 - 23
1 Jun 2021


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 87 - 87
1 Mar 2021
Bommireddy L Crimmins A Gogna R Clark DI
Full Access

Abstract. Objectives. Operative management of distal humerus fractures is challenging. In the past, plates were manually contoured intraoperatively, however this was associated with high rates of fixation failure, nonunion and metalwork removal. Anatomically pre-contoured distal humerus locking plates have since been developed. Owing to the rarity of distal humeral fractures, literature regarding outcomes of anatomically pre-contoured locking plates is lacking and patient numbers are often small. The purpose of this study is to investigate the outcomes of these patients. Methods. We retrospectively identified patients with distal humeral fractures treated at our institution from 2009–2018. Inclusion criteria were patients with a distal humeral fracture, who underwent two-column plate fixation with anatomically pre-contoured locking plates. Clinical records and radiographs were reviewed to elicit outcome measures, including range of motion, complications and reoperation rate. Results. We identified 50 patients with mean age of 55 years (range 17–96 years). Mean length of follow up was 5.2 years. AO fracture classification Type A occurred most frequently (46%), followed by Type B (22%) and Type C (32%). Low energy mechanisms of injury predominated in 72% of patients. Mean time from injury to fixation was seven days. Mean range of motion at the elbow was 13–123o postoperatively. The overall reoperation rate was 22%, the majority of which required subsequent removal of prominent metalwork (18%). The incidence of nonunion, heterotopic ossification, deep infection and neuropathy requiring decompression was 2% each. Fixation failure occurred in only one patient however the fracture went on to heal. Conclusions. Previously reported reoperation rates with manually contoured plates were as high as 44%, which is twice our reported rate. Modern locking plates are no longer subject to implant failure (previously 27% reported metalwork failure rate). Likewise, heterotopic ossification and non-union have also reduced, highlighting that modern plates have significantly improved overall patient outcomes. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Bone & Joint 360
Vol. 10, Issue 1 | Pages 28 - 31
1 Feb 2021


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 71 - 71
1 Aug 2020
Meldrum A Schneider P Harrison T Kwong C Archibold K
Full Access

Olecranon Osteotomy is a common approach used in the management of intraarticular distal humerus fractures. Significant complication rates have been associated with this procedure, including non-union rates of 0–13% and implant removal rates between 12–86%. This study is a multicentre retrospective study involving the largest cohort of olecranon osteotomies in the literature, examining implant fixation types, removal rates and associated complications. Patients were identified between 2007 and 2017 (minimum one year follow-up) via Canadian Classification of Health Interventions (CCI) coding and ICD9/10 codes by our health region's data information service. CCI intervention codes were used to identify patients who underwent surgery for their fracture with an olecranon osteotomy. Reasons for implant removal were identified from a chart review. Our primary outcome was implant removal rates. Categorical data was assessed using Chi square test and Fischer's Exact test. Ninety-nine patients were identified to have undergone an olecranon osteotomy for treatment of a distal humerus fracture. Twenty patients had their osteotomy fixed with a plate and screws and 67 patients were fixed with a tension band wire. Eleven patients underwent “screw fixation”, consisting of a single screw with or without the addition of a wire. One patient had placement of a cable-pin system. Of patients who underwent olecranon osteotomy fixation, 34.3% required implant removal. Removal rates were: 28/67 for TBW (41.8%), 6/20 plates (30%), 0/1 cable-pin and 0/11 for osteotomies fixed with screw fixation. Screw fixation was removed less frequently than TBW p<.006. TBW were more commonly removed than all other fixation types p<.043. Screws were less commonly removed than all other fixation types p<.015. TBW were more likely to be removed for implant irritation than plates, p<.007, and all other implants p<.007. The average time to removal was 361 days (80–1503 days). A second surgeon was the surgeon responsible for the removal in 10/34 cases (29%). TBWs requiring removal were further off the olecranon tip than those not removed p=.006. TBWs were associated with an OR of 3.29 (CI 1.10–9.84) for implant removal if implanted further than 1mm off bone. Nonunion of the osteotomy occurred in three out of 99 patients (3%). K-wires through the anterior ulnar cortex did not result in decreased need for TBW removal. There was no relation between plate prominence and the need for implant removal. There was no association between age and implant removal. The implant removal rate was 34% overall. Single screw fixation was the best option for osteotomy fixation, as 0/11 required hardware removal, which was statistically less frequent than TBW at 28/67. Screw fixation was removed less frequently than TBW and screw fixation was less commonly removed than all other fixation types. Only 6/20 (30%) plates required removal, which is lower than previously published rates. Overall, TBW were more commonly removed than all other fixation types and this was also the case if hardware irritation was used as the indication for removal. Nonunion rates of olecranon osteotomy were 3%


Bone & Joint 360
Vol. 9, Issue 4 | Pages 30 - 33
1 Aug 2020


Bone & Joint 360
Vol. 9, Issue 2 | Pages 3 - 6
1 Apr 2020
Myint Y Ollivere B


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 65 - 65
1 Nov 2018
Hoekzema N
Full Access

Advancements in treating distal humerus fractures. We will review and discuss approaches to the elbow to treat different types of fractures. We will discuss the role of soft tissue structures and how they affect elbow function. During this session, we will review the latest techniques for treating the complex articular fractures of the distal humerus to include capitellar and trochlear fractures. Techniques presented will address fixation, reconstruction, and salvaging of complex distal humerus fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 4 - 4
1 May 2018
Batten T Sin-Hindge C Brinsden M Guyver P
Full Access

We aimed to assess the functional outcomes of elderly patients with isolated comminuted distal humerus fractures that were managed non-operatively. Retrospective analysis of patients over 65 years presenting to our unit between 2005–2015 was undertaken. 67 patients were identified, 7 had immediate TEA, 41 died and 5 were lost to follow-up leaving 14 available for review. Mean Follow-up was 55 months(range 17–131) Patient functional outcomes were measured using VAS scores for pain at rest and during activity, and the Oxford Elbow Score (OES). Need for conversion to TEA and complications were recorded. The mean age at injury was 76 years(range 65–90) of which 79%(11/14) were females. The mean score on the OES was 46(range 29 – 48). The mean VAS score at rest was 0.4(range 0–6) and the mean VAS score during activity was 1.3(range 0–9). 93%(13/14) of patients reported no pain (0 out of 10 on the numeric scale for pain) in their injured elbow at rest and 79%(11/14) reported no pain during activity. No patients converted to TEA and there were no complications. Non-operative management of comminuted distal humerus fractures should be considered for elderly patients, avoiding surgical risks whilst giving satisfactory functional outcomes in this low demand group


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 53 - 53
1 Mar 2017
Levy J Kurowicki J Triplet J Law T Niedzielak T
Full Access

Background. Level 1 studies for fracture management of upper extremity fractures remains rare. The influence of these studies on management trends has yet to be evaluated. The purpose of this study was to examine alterations in national trends managing mid-shaft clavicle and intra-articular distal humerus fractures (DHF) surrounding recent Level 1 publications. Methods. We retrospectively reviewed a comprehensive Medicare (2005–2012) and Humana (2007–2014) patient population database within the PearlDiver supercomputer (Warsaw, IN, USA) for DHF and mid-shaft clavicle fractures, respectively. Non-operative management and open reduction internal fixation (ORIF) were reviewed for mid-shaft clavicle fractures. ORIF and total elbow arthroplasty (TEA) were reviewed for DHF. Total use and annual utilization rates were investigated using age limits defined in the original Level 1 studies. Results. A total of 4,929 clavicle patients between 15 and 59 years, and 106,535 DHF patients greater than 65 years of age were coded. There was no significant change in annual volume of mid-shaft clavicle fractures and DHF coded (p=0.078 and p=0.614, respectively). Among clavicle patients there was a significant increase in ORIF utilization following the publication of the Level 1 study (p=0.002), and a strong, positive correlation was evident (p=0.007). No significant change in annual TEA (p=0.515) utilization for DHF was seen. Conclusion. A significant increase in the utilization of ORIF for clavicular fractures was observed following the publication of supporting Level 1 evidence. This was not observed following similar evidence in managing DHF, as no increase in utilization of TEA was observed