Advertisement for orthosearch.org.uk
Results 1 - 20 of 41
Results per page:
Bone & Joint 360
Vol. 13, Issue 6 | Pages 30 - 33
1 Dec 2024

The December 2024 Shoulder & Elbow Roundup. 360. looks at: Predicting recurrence of instability after a primary traumatic anterior shoulder dislocation; Predictors of surgery and long-term outcomes in nonoperative management of full-thickness rotator cuff tears; Reverse shoulder arthroplasty viable despite acquired acromial compromise, but higher infection risk noted; LP-PRP reduces retear rates in rotator cuff repair but shows no functional outcome advantage; Long-term clinical outcomes of arthroscopic supraspinatus tendon repair using the single anchor tension band technique – minimum five-year follow-up; Arthroscopic stabilization for anterior shoulder dislocation shows low recurrence rates regardless of prior dislocations; ORIF outperforms arthroplasty for complex radial head fractures: mid-term outcomes; Routine use of surgical helmet systems may not reduce infection risk in shoulder arthroplasty


Bone & Joint Open
Vol. 5, Issue 10 | Pages 894 - 897
16 Oct 2024
Stoneham A Poon P Hirner M Frampton C Gao R

Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties. Methods. We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre. Results. A total of 2,728 operations (17%) took place using surgical helmet systems. Patient cohorts were broadly similar in terms of indication for surgery (osteoarthritis, rheumatoid arthritis, fractures) and medical comorbidities (age and sex). There were 842 revisions (5% of cases) with just 98 for deep infection (0.6% of all cases or 11.6% of the revisions). There were no differences in all-cause revisions or revision for deep infection between the surgical helmet systems and conventional gowns (p = 0.893 and p = 0.911, respectively). Conclusion. We found no evidence that wearing a surgical helmet system reduces the incidence of periprosthetic joint infection in any kind of primary shoulder arthroplasty. We acknowledge the limitations of this registry study and accept that there may be other benefits in terms of personal protection, comfort, or visibility. However, given their financial and ecological footprint, they should be used judiciously in shoulder surgery. Cite this article: Bone Jt Open 2024;5(10):894–897


Bone & Joint 360
Vol. 13, Issue 1 | Pages 41 - 43
1 Feb 2024

The February 2024 Research Roundup. 360. looks at: If you use a surgical helmet, you should seal your gown-glove interface; The use of iodophor-impregnated drapes in patients with iodine-related allergies: a case series and review of the literature; Location of the ovaries in children and efficacy of gonadal shielding in hip and pelvis radiography; Prehospital tranexamic acid administration does not improve outcomes in severe trauma patients; Silver-coated distal femur megaprosthesis in chronic infections with severe bone loss: a multicentre case series


Bone & Joint Open
Vol. 4, Issue 11 | Pages 859 - 864
13 Nov 2023
Chen H Chan VWK Yan CH Fu H Chan P Chiu K

Aims. The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. Methods. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed. Results. The leakage intensity increased with exposure duration and frequency of glove exchanges in all groups. When SHS was used and GGI was not sealed (H+S-), the leakage intensity via GGI had the fastest increase, consistently higher than other groups (H+S+, H-S+ and H-S-) after 30 minutes (p < 0.05) and when there were more than four instances of glove exchange (p < 0.05). Additionally, the leakage was strongly correlated with the duration of exposure (r. s. = 0.8379; p < 0.050) and the frequency of glove exchange (r. s. = 0.8198; p < 0.050) in H+S-. The correlations with duration and frequency turned weak when SHS was not used (H-) or GGI was sealed off (S+). Conclusion. Due to personal protection, SHS is recommended in arthroplasties. Meanwhile, it is strongly recommended to seal the GGI of the inner gloves and exchange the outer gloves hourly to reduce the risk of contamination from SHS. Cite this article: Bone Jt Open 2023;4(11):859–864


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 71 - 71
7 Nov 2023
Nzimande D Sukati F
Full Access

Trauma patients present with different injuries and some of them require emergency surgical procedures. Orthopaedic department at Steve Biko Academic Hospital (SBAH) have seen an increasing number of patients presenting with serious orthopaedic injuries due to Delivery Motorbike Accidents (DMBA). The aim of the study was to establish the epidemiology and pattern of orthopaedic injuries sustained following Delivery Motorbike Accident. Motor Vehicle Accident (MVA) administration office at SBAH in emergency department was approached for patients registers used between 1 January 2020 and 31 December 2022. There patients were registered as Motor Vehicle Accident (MVA), Motorbike Accident (MBA) and Pedestrian Vehicle Accident (PVA) by the administration office. The details of patients classified as MBA were collected and used to obtain clinical data from medical and radiological records in the form of patient's files and PACS respectively. Approximately 240 patients presented to Emergency department with orthopaedic injuries following a motorbike accident. About 78 files could not be retrieved from the patient's records department. About 74patients had their occupation recorded as unknown or unemployed. Approximately 70 patients had their occupation indicated in the file by the Clinicians or Administration Clerks. About 40 patients had their occupation as delivery man or working for a delivery company. 16 patients did not have images on the PACS system. Most of the patients were males, presented after hours and sustained multiple injuries that were managed surgically. Very few patients had their helmet status indicated in the file. The study suggests that accidents due to delivery motorbikes are prevalent at SBAH and result in orthopaedic injuries. Almost 50% of patients who had their occupation indicated in the file were delivery employees. A follow up prospective study is recommended to ensure complete collection of data from patients at presentation to ED


Bone & Joint Open
Vol. 3, Issue 9 | Pages 674 - 683
1 Sep 2022
Singh P Jami M Geller J Granger C Geaney L Aiyer A

Aims. Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters. Methods. We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using t-tests and p-values < 0.05 were considered significant. Results. We studied 5,705 patients from 34 studies. The mean age was 33.3 years (SD 3.5), and 58.3% (n = 3,325) were male. The leading mechanism of injury was falling (n = 3,595, 74.4%). Injured patients were more likely to not wear a helmet (n = 2,114; 68.1%; p < 0.001). The most common type of injury incurred was bony injuries (n = 2,761, 39.2%), of which upper limb fractures dominated (n = 1,236, 44.8%). Head and neck injuries composed 22.2% (n = 1,565) of the reported injuries, including traumatic brain injuries (n = 455; 2.5%), lacerations/abrasions/contusions (n = 500; 7.1%), intracerebral brain haemorrhages (n = 131; 1.9%), and concussions (n = 255; 3.2%). Standard radiographs comprised most images (n = 2,153; 57.7%). Most patients were treated and released without admission (n = 2,895; 54.5%), and 17.2% (n = 911) of injured patients required surgery. Qualitative analyses of the cost of injury revealed that any intoxication was associated with higher billing costs. Conclusion. The leading injuries from e-scooters are upper limb fractures. Falling was the leading mechanism of injury, and most patients did not wear a helmet. Future research should focus on injury characterization, treatment, and cost. Cite this article: Bone Jt Open 2022;3(9):674–683


Bone & Joint Open
Vol. 3, Issue 1 | Pages 35 - 41
9 Jan 2022
Buchalter DB Nduaguba A Teo GM Kugelman D Aggarwal VK Long WJ

Aims

Despite recent literature questioning their use, vancomycin and clindamycin often substitute cefazolin as the preoperative antibiotic prophylaxis in primary total knee arthroplasty (TKA), especially in the setting of documented allergy to penicillin. Topical povidone-iodine lavage and vancomycin powder (VIP) are adjuncts that may further broaden antimicrobial coverage, and have shown some promise in recent investigations. The purpose of this study, therefore, is to compare the risk of acute periprosthetic joint infection (PJI) in primary TKA patients who received cefazolin and VIP to those who received a non-cephalosporin alternative and VIP.

Methods

This was a retrospective cohort study of 11,550 primary TKAs performed at an orthopaedic hospital between 2013 and 2019. The primary outcome was PJI occurring within 90 days of surgery. Patients were stratified into two groups (cefazolin vs non-cephalosporin) based on their preoperative antibiotic. All patients also received the VIP protocol at wound closure. Bivariate and multiple logistic regression analyses were performed to control for potential confounders and identify the odds ratio of PJI.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 28 - 28
1 Aug 2021
Whelton C Barrow J Singhal R Board T
Full Access

Orthopaedic surgical hoods rely on an intrinsic fan to force clean external air over the wearer and allow potentially contaminated and expired air to flow down and away from the surgical field. Carbon dioxide (CO. 2. ) is produced through aerobic metabolism and can potentially accumulate inside the hood. Levels above 2500ppm have been shown to affect cognitive and practical function in flight simulator studies. Maximum Health and Safety Executive (HSE) 8-hour exposure limit is 5000ppm There is a paucity of data on real-world CO. 2. levels experienced during arthroplasty surgery whilst wearing a hood. CO. 2. levels were continuously recorded during 31 elective arthroplasties, both primary and revision. Data was collected for surgeon and assistant. Data was recorded at 0.5Hz throughout the procedure utilising a Bluetooth CO. 2. detector, worn inside a Stryker Flyte. ™. surgical helmet worn with a toga gown. Four surgeons contributed real time data to the study. This data was augmented with experimental data, investigating varying fan speeds and activity levels. Median operative duration was 82 minutes (range 36–207). The average CO. 2. level across all procedures was 2952ppm, with 22 of the cases having a mean above 2500ppm, but none having a mean above 5000ppm. For each procedure, the time spent above 2500 and 5000 ppm was calculated, with the average being 68.4 % and 5.6% respectively. The experimental data demonstrated higher CO. 2. levels with lower fan speed, and at higher activity levels, and levels exceeding 15000 ppm during gentle exercise. During operative cases, low fan speed cases did have a marginally higher mean CO. 2. value than high fan speed (3033.02 and 2903.56 respectively) but the small numbers of cases (n=10) where this data was captured limit the relevance of this difference. The use of surgical helmets for elective orthopaedic surgery, can results in CO. 2. levels regularly rising to a point which may affect cognitive function. This study recommends the use of a higher fan speed where possible to minimise the risk of such CO. 2. levels, and recommends further research in this area


Bone & Joint Open
Vol. 1, Issue 5 | Pages 144 - 151
21 May 2020
Hussain ZB Shoman H Yau PWP Thevendran G Randelli F Zhang M Kocher MS Norrish A Khanduja V

Aims

The COVID-19 pandemic presents an unprecedented burden on global healthcare systems, and existing infrastructures must adapt and evolve to meet the challenge. With health systems reliant on the health of their workforce, the importance of protection against disease transmission in healthcare workers (HCWs) is clear. This study collated responses from several countries, provided by clinicians familiar with practice in each location, to identify areas of best practice and policy so as to build consensus of those measures that might reduce the risk of transmission of COVID-19 to HCWs at work.

Methods

A cross-sectional descriptive survey was designed with ten open and closed questions and sent to a representative sample. The sample was selected on a convenience basis of 27 senior surgeons, members of an international surgical society, who were all frontline workers in the COVID-19 pandemic. This study was reported according to the Standards for Reporting Qualitative Research (SRQR) checklist.


Bone & Joint Open
Vol. 1, Issue 4 | Pages 74 - 79
24 Apr 2020
Baldock TE Bolam SM Gao R Zhu MF Rosenfeldt MPJ Young SW Munro JT Monk AP

Aim

The coronavirus disease 2019 (COVID-19) pandemic presents significant challenges to healthcare systems globally. Orthopaedic surgeons are at risk of contracting COVID-19 due to their close contact with patients in both outpatient and theatre environments. The aim of this review was to perform a literature review, including articles of other coronaviruses, to formulate guidelines for orthopaedic healthcare staff.

Methods

A search of Medline, EMBASE, the Cochrane Library, World Health Organization (WHO), and Centers for Disease Control and Prevention (CDC) databases was performed encompassing a variety of terms including ‘coronavirus’, ‘covid-19’, ‘orthopaedic’, ‘personal protective environment’ and ‘PPE’. Online database searches identified 354 articles. Articles were included if they studied any of the other coronaviruses or if the basic science could potentially applied to COVID-19 (i.e. use of an inactivated virus with a similar diameter to COVID-19). Two reviewers independently identified and screened articles based on the titles and abstracts. 274 were subsequently excluded, with 80 full-text articles retrieved and assessed for eligibility. Of these, 66 were excluded as they compared personal protection equipment to no personal protection equipment or referred to prevention measures in the context of bacterial infections.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1331 - 1347
1 Nov 2019
Jameson SS Asaad A Diament M Kasim A Bigirumurame T Baker P Mason J Partington P Reed M

Aims

Antibiotic-loaded bone cements (ALBCs) may offer early protection against the formation of bacterial biofilm after joint arthroplasty. Use in hip arthroplasty is widely accepted, but there is a lack of evidence in total knee arthroplasty (TKA). The objective of this study was to evaluate the use of ALBC in a large population of TKA patients.

Materials and Methods

Data from the National Joint Registry (NJR) of England and Wales were obtained for all primary cemented TKAs between March 2003 and July 2016. Patient, implant, and surgical variables were analyzed. Cox proportional hazards models were used to assess the influence of ALBC on risk of revision. Body mass index (BMI) data were available in a subset of patients.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 646 - 651
1 Jun 2019
Aggarwal VK Elbuluk A Dundon J Herrero C Hernandez C Vigdorchik JM Schwarzkopf R Iorio R Long WJ

Aims

A variety of surgical approaches are used for total hip arthroplasty (THA), all with reported advantages and disadvantages. A number of common complications can occur following THA regardless of the approach used. The purpose of this study was to compare five commonly used surgical approaches with respect to the incidence of surgery-related complications.

Patients and Methods

The electronic medical records of all patients who underwent primary elective THA at a single large-volume arthroplasty centre, between 2011 and 2016, with at least two years of follow-up, were reviewed. After exclusion, 3574 consecutive patients were included in the study. There were 1571 men (44.0%) and 2003 women (56.0%). Their mean age and body mass index (BMI) was 63.0 years (sd 11.8) and 29.1 kg/m2 (sd 6.1), respectively. Data gathered included the age of the patient, BMI, the American Society of Anesthesiologists (ASA) score, estimated blood loss (EBL), length of stay (LOS), operating time, the presence of intra- or postoperative complications, type of complication, and the surgical approach. The approaches used during the study were posterior, anterior, direct lateral, anterolateral, and the northern approach. The complications that were recorded included prolonged wound drainage without infection, superficial infection, deep infection, dislocation, aseptic loosening, and periprosthetic fracture. Finally, the need for re-operation was recorded. Means were compared using analysis of variance (ANOVA) and Student’s t-tests where appropriate and proportions were compared using the chi-squared test.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 2 - 8
1 Jun 2019
Aggarwal VK Weintraub S Klock J Stachel A Phillips M Schwarzkopf R Iorio R Bosco J Zuckerman JD Vigdorchik JM Long WJ

Aims

We studied the impact of direct anterior (DA) versus non-anterior (NA) surgical approaches on prosthetic joint infection (PJI), and examined the impact of new perioperative protocols on PJI rates following all surgical approaches at a single institution.

Patients and Methods

A total of 6086 consecutive patients undergoing primary total hip arthroplasty (THA) at a single institution between 2013 and 2016 were retrospectively evaluated. Data obtained from electronic patient medical records included age, sex, body mass index (BMI), medical comorbidities, surgical approach, and presence of deep PJI. There were 3053 male patients (50.1%) and 3033 female patients (49.9%). The mean age and BMI of the entire cohort was 62.7 years (18 to 102, sd 12.3) and 28.8 kg/m2 (13.3 to 57.6, sd 6.1), respectively. Infection rates were calculated yearly for the DA and NA approach groups. Covariates were assessed and used in multivariate analysis to calculate adjusted odds ratios (ORs) for risk of development of PJI with DA compared with NA approaches. In order to determine the effect of adopting a set of infection prevention protocols on PJI, we calculated ORs for PJI comparing patients undergoing THA for two distinct time periods: 2013 to 2014 and 2015 to 2016. These periods corresponded to before and after we implemented a set of perioperative infection protocols.


Bone & Joint Research
Vol. 6, Issue 9 | Pages 566 - 571
1 Sep 2017
Cheng T Zhang X Hu J Li B Wang Q

Objectives

Surgeons face a substantial risk of infection because of the occupational exposure to blood-borne pathogens (BBPs) from patients undergoing high-risk orthopaedic procedures. This study aimed to determine the seroprevalence of four BBPs among patients undergoing joint arthroplasty in Shanghai, China. In addition, we evaluated the significance of pre-operative screening by calculating a cost-to-benefit ratio.

Methods

A retrospective observational study of pre-operative screening for BBPs, including hepatitis B and C viruses (HBV and HCV), human immunodeficiency virus (HIV) and Treponema pallidum (TP), was conducted for sequential patients in the orthopaedic department of a large urban teaching hospital between 01 January 2009 and 30 May 2016. Medical records were analysed to verify the seroprevalence of these BBPs among the patients stratified by age, gender, local origin, type of surgery, history of previous transfusion and marital status.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 917 - 920
1 Jul 2017
Bloch BV Shah A Snape SE Boswell TCJ James PJ

Aims

Infection following total hip or knee arthroplasty is a serious complication. We noted an increase in post-operative infection in cases carried out in temporary operating theatres. We therefore compared those cases performed in standard and temporary operating theatres and examined the deep periprosthetic infection rates.

Patients and methods

A total of 1223 primary hip and knee arthroplasties were performed between August 2012 and June 2013. A total of 539 (44%) were performed in temporary theatres. The two groups were matched for age, gender, body mass index and American Society of Anesthesiologists grade.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 8 - 8
1 Jun 2017
Moores T Chatterton B Khan S Harvey G Lewthwaite S
Full Access

Deep infection occurs in 2–4% of lower limb arthroplasty resulting in increasing cost, co-morbidity and challenging revision arthroplasty surgery. Identifying the potential sources of infection helps reduce infection rates. The aim of our study is to identify the impact and potential for contamination of our hands and gowns whilst scrubbing using SSHS.

A colony-forming unit (CFU) is a pathogenic particle of 0.5 micrometers to 5 micrometers. Concurrent particle counts and blood agar exposure settle plates for 3 subjects and 1 alcohol cleaned mannequin; testing a standard arthroplasty hood, a SSHS with and without the fan on for a 2 minute exposure to represent scrubbing time. Microbiological plates were incubated using a standard protocol by our local microbiology department.

All SSHS were positive for gram-positive cocci with a mean colony count of 410cfu/m2. Comparing background counts for laminar flow (mean 0.7 particle/m3; 95% CI 0–1.4) versus scrub areas (mean 131.5 particle/m3; 95% CI 123.5–137.9; p=0.0003), however neither grew any CFU's with a 2-minute exposure. For the mannequin, the only significant result was with the fan on with a 1.5× increase in the particle count (p=0.042) and a correlating positive organism (13CFU/m2). With human subjects, however, the particle count increased by 3.75× the background count with the fan on (total p=0.004, CFU p=0.047) and all had positive cultures, mean 36 CFU/m2. There were no positive cultures with the standard arthroplasty hood or the SSHS with no fan on. If repeated in laminar flow, there was only a statistically significant increase with the fan on (p=0.049), but with negative cultures following a 2-minute exposure.

Sterile gloves and gowns can be contaminated when scrubbing with the SSHS fan on. We recommend having the fan switched off when scrubbing until the hood and gown is in place, ideally in a laminar flow environment.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 3 - 10
1 Apr 2017
Parvizi J Shohat N Gehrke T

The World Health Organization (WHO) and the Centre for Disease Control and Prevention (CDC) recently published guidelines for the prevention of surgical site infection. The WHO guidelines, if implemented worldwide, could have an immense impact on our practices and those of the CDC have implications for healthcare policy in the United States.

Our aim was to review the strategies for prevention of periprosthetic joint infection in light of these and other recent guidelines.

Cite this article: Bone Joint J 2017;99-B(4 Supple B):3–10.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1262 - 1269
1 Sep 2016
Pinder EM Bottle A Aylin P Loeffler MD

Aims

To determine whether there is any difference in infection rate at 90 days between trauma operations performed in laminar flow and plenum ventilation, and whether infection risk is altered following the installation of laminar flow (LF).

Patients and Methods

We assessed the impact of plenum ventilation (PV) and LF on the rate of infection for patients undergoing orthopaedic trauma operations. All NHS hospitals in England with a trauma theatre(s) were contacted to identify the ventilation system which was used between April 2008 and March 2013 in the following categories: always LF, never LF, installed LF during study period (subdivided: before, during and after installation) and unknown. For each operation, age, gender, comorbidity, socio-economic deprivation, number of previous trauma operations and surgical site infection within 90 days (SSI90) were extracted from England’s national hospital administrative Hospital Episode Statistics database. Crude and adjusted odds ratios (OR) were used to compare ventilation groups using hierarchical logistic regression. Subanalysis was performed for hip hemiarthroplasties.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 48 - 48
1 May 2016
Spangehl M Fraser J Young S Probst N Valentine K
Full Access

Introduction. The original Charnley-type negative pressure body exhaust suit reduced infection rates in randomized trials of total joint arthroplasty decades ago. Modern positive pressure surgical helmet systems (SHS) have not shown similar benefit, and several recent studies have shown a trend towards increased wound contamination and infection with SHS use. The gown glove interface may be one source of particle contamination. Objectives. The purpose of this study was to compare particle contamination at the gown glove interface in several modern SHS vs. a conventional gown. Methods. A 0.5 micron fluorescent powder was evenly applied to both hands to the level of the wrist flexion crease. After gowning in the normal fashion, the acting surgeon performed a standardized twenty minute simulated total joint replacement. The amount of gown contamination at the gown glove interface was then measured by three observers under ultraviolet light using a standardized grading scale; from 0 (no contamination) to 4 (gross contamination). Using Minitab 15, the Mann-Whitney U test was performed to compare gowns and an ordinal logistic regression analysis was performed to identify variables associated with levels of contamination. Results. All gown-glove interfaces showed some contamination. There was no difference among any of the gowns except for gown 2, which showed significantly more contamination when compared directly to each of the other four gowns (p<0.001 in each case) (Figure 1). The ordinal logistic regression analysis showed that gown type (p 0.10) was more significantly associated with contamination levels than were the other variables of observer (p 0.70), location of contamination (p 0.56), or trial order (p 0.5). Conclusions. Particle contamination occurs at the gown glove interface in most commonly used surgical helmet systems and was significantly increased in the gown with stiffer material that may be less apt to make a seal with the glove


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 334 - 340
1 Mar 2016
Tayton ER Frampton C Hooper GJ Young SW

Aims. The aim of this study was to identify risk factors for prosthetic joint infection (PJI) following total knee arthroplasty (TKA). . Patients and Methods. The New Zealand Joint Registry database was analysed, using revision surgery for PJI at six and 12 months after surgery as primary outcome measures. Statistical associations between revision for infection, with common and definable surgical and patient factors were tested. Results. A total of 64 566 primary TKAs have been recorded on the registry between 1999 and 2012 with minimum follow-up of 12 months. Multivariate analysis showed statistically significant associations with revision for PJI between male gender (odds ratio (OR) 1.85, 95% confidence interval (CI) 1.24 to 2.74), previous surgery (osteotomy (OR 2.45 95% CI 1.2 to 5.03), ligament reconstruction (OR 1.85, 95% CI 0.68 to 5.00)), the use of laminar flow (OR 1.6, 95% CI 1.04 to 2.47) and the use of antibiotic-laden cement (OR 1.93, 95% CI 1.19 to 3.13). There was a trend towards significance (p = 0.052) with the use of surgical helmet systems at six months (OR 1.53, 95% CI 1.00 to 2.34). Conclusion. These findings show that patient factors remain the most important in terms of predicting early PJI following TKA. Furthermore, we found no evidence that modern surgical helmet systems reduce the risk of PJI and laminar flow systems may actually increase risk in TKA. The use of this registry data assists the estimation of the risk of PJI for individual patients, which is important for both informed consent and the interpretation of infection rates at different institutions. . Take home message: Infection rates in TKA are related to both individual patient and surgical factors, and some modern methods of reducing infection may actually increase infection risk. . Cite this article: Bone Joint J 2016;98-B:334–40