The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.Aims
Methods
The April 2023 Children’s orthopaedics Roundup. 360. looks at: CT scan of the ipsilateral femoral neck in paediatric shaft fractures; Meniscal injuries in skeletally immature children with tibial eminence fractures: a systematic literature review; Post-maturity progression in adolescent idiopathic scoliosis curves of 40° to 50°; Prospective, randomized Ponseti treatment for clubfoot: orthopaedic surgeons versus physical therapists; FIFA 11+ Kids: challenges in implementing a prevention programme; The management of developmental dysplasia of the hip in children aged under three months: a consensus study from the British Society for Children's Orthopaedic Surgery; Early investigation and bracing in developmental dysplasia of the hip impacts maternal wellbeing and breastfeeding;
Aims. To examine the long-term outcome of arthrodesis of the hip undertaken in a paediatric population in treating painful arthritis of the hip. In our patient population, most of whom live rurally in hilly terrain and have limited healthcare access and resources,
Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8).Aims
Methods
Patients with longstanding hip fusion are predisposed to symptomatic degenerative changes of the lumbar spine, ipsilateral knee and contralateral hip. 1. In such patients, conversion of
Appropriate acetabular component placement has been proposed for prevention of postoperative dislocation in total hip arthroplasty (THA). Manual placements often cause outliers in spite of attempts to insert the component within the intended safe zone; therefore, some surgeons routinely evaluate intraoperative pelvic radiographs to exclude excessive acetabular component malposition. However, their evaluation is often ambiguous in case of the tilted or rotated pelvic position. The purpose of this study was to develop the computational analysis to digitalize the acetabular component orientation regardless of the pelvic tilt or rotation. Intraoperative pelvic radiographs of 50 patients who underwent THA were collected retrospectively. The 3D pelvic bone model and the acetabular component were image-matched to the intraoperative pelvic radiograph. The radiological anteversion (RA) and radiological inclination (RI) of the acetabular component were calculated and those measurement errors from the postoperative CT data were compared relative to those of the 2D measurements. In addition, the intra- and interobserver differences of the image-matching analysis were evaluated.Aims
Methods
This study aimed to explore whether intraoperative nerve monitoring can identify risk factors and reduce the incidence of nerve injury in patients with high-riding developmental dysplasia. We conducted a historical controlled study of patients with unilateral Crowe IV developmental dysplasia of the hip (DDH). Between October 2016 and October 2017, intraoperative nerve monitoring of the femoral and sciatic nerves was applied in total hip arthroplasty (THA). A neuromonitoring technician was employed to monitor nerve function and inform the surgeon of ongoing changes in a timely manner. Patients who did not have intraoperative nerve monitoring between September 2015 and October 2016 were selected as the control group. All the surgeries were performed by one surgeon. Demographics and clinical data were analyzed. A total of 35 patients in the monitoring group (ten male, 25 female; mean age 37.1 years (20 to 46)) and 56 patients in the control group (13 male, 43 female; mean age 37.9 years (23 to 52)) were enrolled. The mean follow-up of all patients was 13.1 months (10 to 15).Aims
Patients and Methods
The main challenges in
The modified Dunn procedure has the potential to restore the anatomy in hips with severe slipped capital femoral epiphyses (SCFE). However, there is a risk of developing avascular necrosis of the femoral head (AVN). In this paper, we report on clinical outcome, radiological outcome, AVN rate and complications, and the cumulative survivorship at long-term follow-up in patients undergoing the modified Dunn procedure for severe SCFE. We performed a retrospective analysis involving 46 hips in 46 patients treated with a modified Dunn procedure for severe SCFE (slip angle > 60°) between 1999 and 2016. At nine-year-follow-up, 40 hips were available for clinical and radiological examination. Mean preoperative age was 13 years, and 14 hips (30%) presented with unstable slips. Mean preoperative slip angle was 64°. Kaplan–Meier survivorship was calculated.Aims
Patients and Methods
The modified Dunn procedure has the potential to restore the anatomy in hips with slipped capital femoral epiphyses (SCFE) while protecting the blood supply to the femoral head. However, there is controversy about the risks associated with the procedure especially in the most severe capital slips. Therefore, we report on (1) clinical outcome, (2) the cumulative survivorship with endpoints AVN and/or OA progression and (3) radiographic anatomy of the proximal femur at followup in patients treated with a modified Dunn procedure for severe SCFE. We performed a retrospective analysis involving 46 hips of 46 patients treated with a modified Dunn procedure for severe SCFE (slip angle >60°) between 1999 and 2016. Followup averaged 8 years, (range 1–17) with 2 patients lost to followup after one year. The mean age was 13 years (range 9–19 years). Mean preoperative slip angle was 64° (range 60–90) and 14 out of 46 hips (30%) presented with unstable slips. Clinical scores and PROMs were evaluated and the hips were followed standard x-rays. Cumulative survivorship (Kaplan-Meier) with three defined endpoints: (1) AVN; (2) progression by at least one OA grade according to Tönnis; (3) non-preserved hip joint. (1)Mean Harris Hip score (HHS) was 93 points (66–100) and mean Hip Disability and Osteoarthritis Outcome Score (HOOS) was 90 points (67–100) at last followup. (2)Cumulative survivorship was 93% at 10-year followup. Three hips reached an endpoint. Two hips (4%) had AVN, one of them underwent
The aim of this study was to compare the rate of mortality and
causes of death in Korean patients who undergo surgery for a fracture
of the hip, up to 11 years after the injury, with a control group
from the general population. National cohort data from Korean Health Insurance Review and
Assessment Service – National Sample Cohort were used. A ratio of
1:4 matched patients with a fracture who underwent surgery (3383,
fracture group) between 2003 and 2012, and controls (13 532) were
included. The matches were processed for age, gender, income, and
region of residence. We also undertook analyses of subgroups according
to age and gender. The mean follow-up was 4.45 years (1 to 11).Aims
Materials and Methods
The main challenges in
To determine the effect of a change in design of a cementless
ceramic acetabular component in fixation and clinical outcome after
total hip arthroplasty We compared 342 hips (302 patients) operated between 1999 and
2005 with a relatively smooth hydroxyapatite coated acetabular component
(group 1), and 337 hips (310 patients) operated between 2006 and
2011 using a similar acetabular component with a macrotexture on
the entire outer surface of the component (group 2). The mean age of
the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70)
in group 2. The mean follow-up was 12.7 years (10 to 17) for group
1 and 7.2 years (4 to 10) for group 2.Aims
Patients and Methods
Patients with longstanding hip fusion are predisposed to symptomatic degenerative changes of the lumbar spine, ipsilateral knee and contralateral hip. In such patients, conversion of
Some DEFINITIONS are necessary: “STEMS” refers to “intramedullary stem extensions”, which may be of a variety of lengths and diameters, fixed with cement, porous coating or press fit alone and which may be modular or an inherent part of the prosthesis. The standard extension keel on the tibia does not qualify as a “stem (extension)”. COMPLEX implies multiple variables acting on the end result of the arthroplasty with the capability of inducing failure, as well as necessary variations to the standard surgical technique. A lesser degree of predictability is implied. More specifically, the elements usually found in an arthritic knee and used for the arthroplasty are missing, so that cases of COMPLEX primary TKA include: Soft tissue coverage-(not relevant here), Extensor mechanism deficiency-patellectomy, Severe deformity, Extra-articular deformity, Instability: Varus valgus, Instability: Plane of motion, Instability: Old PCL rupture, Dislocated patella, Stiffness, Medical conditions: Neuromuscular disorder, Ipsilateral arthroplasty, Prior incisions, Fixation hardware, Osteopenia, Ipsilateral
Degenerative problems of the hip in patients
with childhood and adult onset neuromuscular disorders can be challenging
to treat. Many orthopaedic surgeons are reluctant to recommend total
hip replacement (THR) for patients with underlying neuromuscular
disorders due to the perceived increased risks of dislocation, implant loosening,
and lack of information about the functional outcomes and potential
benefits of these procedures in these patients. Modular femoral
components and alternative bearings which facilitate the use of
large femoral heads, constrained acetabular components and perhaps
more importantly, a better understanding about the complications
and outcomes of THR in the patient with neuromuscular disorders,
make this option viable. This paper will review the current literature
and our experience with THR in the more frequently encountered neuromuscular
disorders. Cite this article:
Introduction. Management of the sequelae of arthritis of the hip joint has changed over time. Total joint replacement has gained popularity due to retained mobility and stability. In the high demand paediatric and adolescent population problems are encountered with longevity of the procedure.
We report an intertrochanteric fracture in a patient who had undergone
A total of 219 hips in 192 patients aged between
18 and 65 years were randomised to 28-mm metal-on-metal uncemented
total hip replacements (THRs, 107 hips) or hybrid hip resurfacing
(HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3)
there was no significant difference between the THR and HR groups
regarding rate of revision (4.0% (4 of 99) Cite this article: