Advertisement for orthosearch.org.uk
Results 1 - 20 of 156
Results per page:

Introduction

The evaluation of treatment modalities for distal femur periprosthetic fractures (DFPF) post-total knee arthroplasty (TKA) has predominantly focused on functional and radiological outcomes in existing literature. This study aimed to comprehensively compare the functional and radiological efficacy of locking plate (LP) and retrograde intramedullary nail (IMN) treatments, while incorporating mortality rates.

Method

Twenty patients (15 female, 5 male) with a minimum 24-month follow-up period, experiencing Lewis-Rorabeck type-2 DFPF after TKA were included. These patients underwent either LP (n=10) or IMN (n=10). The average follow-up duration was 48 months (range: 24–192). Treatment outcomes, including functional scores, alignment, union time, complications, and mortality rates, were assessed and compared between LP and IMN groups. Clinical examination findings pre-treatment and at final follow-up, along with two-way plain radiographs, were utilized. Statistical analyses comprised Student's t-test and Kaplan-Meier survival analysis with a 95% confidence interval.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup. 360. looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


Bone & Joint Research
Vol. 13, Issue 3 | Pages 127 - 135
22 Mar 2024
Puetzler J Vallejo Diaz A Gosheger G Schulze M Arens D Zeiter S Siverino C Richards RG Moriarty TF

Aims

Fracture-related infection (FRI) is commonly classified based on the time of onset of symptoms. Early infections (< two weeks) are treated with debridement, antibiotics, and implant retention (DAIR). For late infections (> ten weeks), guidelines recommend implant removal due to tolerant biofilms. For delayed infections (two to ten weeks), recommendations are unclear. In this study we compared infection clearance and bone healing in early and delayed FRI treated with DAIR in a rabbit model.

Methods

Staphylococcus aureus was inoculated into a humeral osteotomy in 17 rabbits after plate osteosynthesis. Infection developed for one week (early group, n = 6) or four weeks (delayed group, n = 6) before DAIR (systemic antibiotics: two weeks, nafcillin + rifampin; four weeks, levofloxacin + rifampin). A control group (n = 5) received revision surgery after four weeks without antibiotics. Bacteriology of humerus, soft-tissue, and implants was performed seven weeks after revision surgery. Bone healing was assessed using a modified radiological union scale in tibial fractures (mRUST).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 107 - 107
2 Jan 2024
Pastor T Zderic I Berk T Souleiman F Vögelin E Beeres F Gueorguiev B Pastor T
Full Access

Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking. Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047. From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable fracture configurations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD.

Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system.

BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension.

ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered.

For any figures or tables, please contact the authors directly.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 36 - 39
1 Dec 2023

The December 2023 Trauma Roundup360 looks at: Distal femoral arthroplasty: medical risks under the spotlight; Quads repair: tunnels or anchors?; Complex trade-offs in treating severe tibial fractures: limb salvage versus primary amputation; Middle-sized posterior malleolus fractures – to fix?; Bone transport through induced membrane: a randomized controlled trial; Displaced geriatric femoral neck fractures; Risk factors for reoperation to promote union in 1,111 distal femur fractures; New versus old – reliability of the OTA/AO classification for trochanteric hip fractures; Risk factors for fracture-related infection after ankle fracture surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 1 - 1
11 Apr 2023
Mischler D Knecht M Varga P
Full Access

Surgical education of fracture fixation biomechanics relies mainly on simplified illustrations to distill the essence of the underlying principles. These mostly consist of textbook drawings or hands-on exercises during courses, both with unique advantages such as broad availability and haptics, respectively. Computer simulations are suited to bridge these two approaches; however, the validity of such simulations must be guaranteed to teach the correct aspects. Therefore, the aim of this study was to validate finite element (FE) simulations of bone-plate constructs to be used in surgical education in terms of fracture gap movement and implant surface strain.

The validation procedure was conducted in a systematic and hierarchical manner with increasing complexity. First, the material properties of the isolated implant components were determined via four-point bending of the plate and three-point bending of the screw. Second, stiffness of the screw-plate interface was evaluated by means of cantilever bending to determine the properties of the locking mechanism. Third, implant surface strain and fracture gap motion were measured by testing various configurations of entire fixation constructs on artificial bone (Canevasit) in axial compression. The determined properties of the materials and interfaces assessed in these experiments were then implemented into FE models of entire fixation constructs with different fracture width and screw configurations. The FE-predicted implant surface strains and fracture gap motions were compared with the experimental results.

The simulated results of the different construct configurations correlated strongly with the experimentally measured fracture gap motions (R2>0.99) and plate surface strains (R2>0.95).

In a systematic approach, FE model validation was achieved successfully in terms of fracture gap motion and implant deformation, confirming trustworthiness for surgical education. These validated models are used in a novel online education tool OSapp (https://osapp.ch/) to illustrate and explain the biomechanical principles of fracture fixations in an interactive manner.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 83 - 83
10 Feb 2023
Lee H Lewis D Balogh Z
Full Access

Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for both acute fixation and revisions. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims

Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK.

Methods

A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages.


Distal radius fractures (DRF) are common and the indication for surgical treatment remain controversial in patients higher than 60 years old. The purpose of the study was to review and analyze the current evidence-based literature.

We performed a systematic review and meta-analysis according to PRISMA guidelines in order to evaluate the efficacy of volar locking plating (VLP) and conservative treatment in DRF in patients over 60 years old. Electronic databases including MEDLINE, CENTRAL, Embase, Web of science and Clinical Trial.gov were searched from inception to October 2020 for randomized controlled trials. Relevant article reference lists were also passed over.

Two reviewers independently screened and extracted the data. Main outcomes included functional status: wrist range of motion, validated scores and grip strength. Secondary outcomes include post-operative complications and radiologic assessment.

From 3009 screened citations, 5 trials (539 patients) met the inclusion criteria. All trials of this random effect meta-analysis were at moderate risk of bias due to lack of blinding. Differences in the DASH score (MD −5,91; 95% CI, −8,83; −3,00), PRWE score (MD −9.07; 95% CI, −14.57, −3.57) and grip strength (MD 5,12; 95% CI, 0,59-9,65) were statistically significant and favored VLPs. No effect was observed in terms of range of motion. Adverse events are frequent in both treatment groups, reoperation rate is higher in the VLP group.

VLP may provide better functional outcomes in patients higher than 60 years old. More RCT are still needed to evaluate if the risks and complications of VLP outweigh the benefits.


Distal radius fractures (DRF) are common and the indication for surgical treatment remain controversial in patients higher than 60 years old. The purpose of the study was to review and analyze the current evidence-based literature.

We performed a systematic review and meta-analysis according to PRISMA guidelines in order to evaluate the efficacy of volar locking plating (VLP) and conservative treatment in DRF in patients over 60 years old. Electronic databases including MEDLINE, CENTRAL, Embase, Web of science and Clinical Trial.gov were searched from inception to October 2020 for randomized controlled trials. Relevant article reference lists were also passed over.

Two reviewers independently screened and extracted the data. Main outcomes included functional status: wrist range of motion, validated scores and grip strength. Secondary outcomes include post-operative complications and radiologic assessment.

From 3009 screened citations, 5 trials (539 patients) met the inclusion criteria. All trials of this random effect meta-analysis were at moderate risk of bias due to lack of blinding. Differences in the DASH score (MD −5,91; 95% CI, −8,83; −3,00), PRWE score (MD −9.07; 95% CI, −14.57, −3.57) and grip strength (MD 5,12; 95% CI, 0,59-9,65) were statistically significant and favored VLPs. No effect was observed in terms of range of motion. Adverse events are frequent in both treatment groups, reoperation rate is higher in the VLP group.

VLP may provide better functional outcomes in patients higher than 60 years old. More RCT are still needed to evaluate if the risks and complications of VLP outweigh the benefits.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 902 - 908
1 Jul 2022
Hsu P Lee C Lin S Kuo KN Wu K Wang T

Aims

The aim of this study was to compare outcomes of guided growth and varus osteotomy in treating Kalamchi type II avascular necrosis (AVN) after open reduction and Pemberton acetabuloplasty for developmental dysplasia of the hip (DDH).

Methods

This retrospective study reviewed patients undergoing guided growth or varus osteotomy for Kalamchi type II AVN between September 2009 and January 2019. All children who had undergone open reduction and Pemberton acetabuloplasty for DDH with a minimum two-year follow-up were enrolled in the study. Demographic and radiological data, which included the head-shaft angle (HSA), neck-shaft angle (NSA), articulotrochanteric distance (ATD), Sharp angle (SA), and lateral centre-edge angle (LCEA) at baseline, two years, and at the extended follow-up, were compared. Revision rates were evaluated. Clinical outcomes using the Harris Hip Score were assessed two years postoperatively.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 69 - 69
1 Nov 2021
Pastor T Zderic I Richards G Gueorguiev B Knobe M
Full Access

Introduction and Objective. Distal femoral fractures are commonly treated with a straight plate fixed to the lateral aspects of both proximal and distal fragments. However, the lateral approach may not always be desirable due to persisting soft-tissue or additional vascular injury necessitating a medial approach. These problems may be overcome by pre-contouring the plate in helically shaped fashion, allowing its distal part to be fixed to the medial aspect of the femoral condyle. The objective of this study was to investigate the biomechanical competence of medial femoral helical plating versus conventional straight lateral plating in an artificial distal femoral fracture model. Materials and Methods. Twelve left artificial femora were instrumented with a 15-hole Locking Compression Plate – Distal Femur (LCP-DF) plate, using either conventional lateral plating technique with the plate left non-contoured, or the medial helical plating technique by pre-contouring the plate to a 180° helical shape and fixing its distal end to the medial femoral condyle (n=6). An unstable extraarticular distal femoral fracture was subsequently simulated by means of an osteotomy gap. All specimens were tested under quasi-static and progressively increasing cyclic axial und torsional loading until failure. Interfragmentary movements were monitored by means of optical motion tracking. Results. Initial axial stiffness was significantly higher for helical (185.6±50.1 N/mm) versus straight (56.0±14.4) plating, p<0.01. However, initial torsional stiffness in internal and external rotation remained not significantly different between the two fixation techniques (helical plating:1.59±0.17 Nm/° and 1.52±0.13 Nm/°; straight plating: 1.50±0.12 Nm/° and 1.43±0.13Nm/°), p≥0.21. Helical plating was associated with significantly higher initial interfragmentary movements under 500 N static compression compared to straight plating in terms of flexion (2.76±1.02° versus 0.87±0.77°) and shear displacement under 6 Nm static rotation in internal (1.23±0.28° versus 0.40±0.42°) and external (1.21±0.40° versus 0.57±0.33°) rotation, p≤0.01. In addition, helical plating demonstrated significantly lower initial varus/valgus deformation than straight plating (4.08±1.49° versus 6.60±0.47°), p<0.01. Within the first 10000 cycles of dynamic loading, helical plating revealed significantly bigger flexural movements and significantly lower varus/valgus deformation versus straight plating, p=0.02. No significant differences were observed between the two fixation techniques in terms of axial and shear displacement, p≥0.76. Cycles to failure was significantly higher for helical plating (13752±1518) compared to straight plating (9727±836), p<0.01. Conclusions. Although helical plating using a pre-contoured LCP-DF was associated with higher shear and flexion movements, it demonstrated improved initial axial stability and resistance against varus/valgus deformation compared to straight lateral plating. Moreover, helical plate constructs demonstrated significantly improved endurance to failure, which may be attributed to the less progressively increasing lever bending moment arm inherent to this novel fixation technique. From a biomechanical perspective, helical plating may be considered as a valid alternative fixation technique to standard straight lateral plating of unstable distal femoral fractures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 24 - 24
1 Nov 2021
Gueorguiev B Zderic I Pastor T Gehweiler D Richards G Knobe M
Full Access

Introduction and Objective. Plating of geriatric distal femoral fractures with Locking Compression Plate Distal Femur (LCP–DF) often requires augmentation with a supplemental medial plate to achieve sufficient stability allowing early mobilization. However, medial vital structures may be impaired by supplemental medial plating using a straight plate. Therefore, a helically shaped medial plate may be used to avoid damage of these structures. Aim of the current study was to investigate the biomechanical competence of augmented LCP–DF plating using a supplemental straight versus helically shaped medial plate. Materials and Methods. Ten pairs of human cadaveric femora with poor bone quality were assigned pairwise for instrumentation using a lateral anatomical 15-hole LCP–DF combined with a medial 14-hole LCP, the latter being either straight or manually pre-contoured to a 90-degree helical shape. An unstable distal femoral fracture AO/OTA 33–A3 was simulated by means of osteotomies. All specimens were biomechanically tested under non-destructive quasi-static and destructive progressively increasing combined cyclic axial and torsional loading in internal rotation, with monitoring by means of optical motion tracking. Results. Initial axial stiffness and torsional stiffness in internal and external rotation for straight double plating (548.1 ± 134.2 N/mm, 2.69 ± 0.52 Nm/° and 2.69 ± 0.50 Nm/°) was significantly higher versus helical double plating (442.9 ± 133.7 N/mm, 2.07 ± 0.32 Nm/° and 2.16 ± 0.22 Nm/°), p≤0.04. Initial interfragmentary axial displacement and flexural rotation under 500 N static loading were significantly smaller for straight plating (0.11 ± 0.14 mm and 0.21 ± 0.10°) versus helical plating (0.31 ± 0.14 mm and 0.68 ± 0.16°), p<0.01. However, initial varus deformation under this loading remained not significantly different between the two fixation methods (straight: 0.57 ± 0.23°, helical: 0.75 ± 0.34°), p=0.08. During dynamic loading, within the course of the first 4000 cycles the movements of the distal fragment in flexion were significantly bigger for helical over straight plating (1.03 ± 0.33° versus 0.40 ± 0.20°), p<0.01. However, no significant differences were observed between the two fixation methods in terms of varus, internal rotation, axial and shear displacements at the fracture site, and number of cycles to failure. Conclusions. Augmented lateral plating of unstable distal femoral fractures with use of supplemental helically shaped medial plate was associated with more elastic bone-implant construct behavior under static and dynamic loading compared to straight double plating. Both fixation methods resulted in comparable number of cycles to failure. From a biomechanical perspective, the more elastic helical double plating may be considered as useful alternative to straight plating, potentially reducing stress risers at the distal bone-implant interface due to its ameliorated damping capacities


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims

The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years.

Methods

From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.