Advertisement for orthosearch.org.uk
Results 1 - 20 of 4903
Results per page:
Bone & Joint Open
Vol. 6, Issue 1 | Pages 82 - 92
14 Jan 2025
Ranieri R Borroni M Delle Rose G Conti M Garofalo R Castagna A

Aims. The aim of this study was to report long-term clinical outcomes of a modern convertible metal-backed glenoid (MBG) in total shoulder arthroplasty (TSA). Methods. After a minimum of 15 years, a previously studied cohort of 35 patients who received a modern convertible MBG during the period 1996 to 2005 was contacted for clinical and radiological follow-up. At last follow-up, patients were evaluated radiologically and clinically according to the Constant Score, Simple Shoulder Test, and visual analogue scale for pain. Complications and revisions were recorded, and survival analysis was performed. Results. At the last follow-up, 20 patients were contacted. Of these, 15 patients had experienced at least one complication, and ten underwent revision surgery. The mean time to revision was 13.8 years (7 to 20). Cuff failure was the most common complication. Conversion to reverse shoulder arthroplasty, while maintaining the baseplate, was possible in five cases, with good results. In patients in whom the baseplate was removed, revision was performed significantly later (18.4 vs 11.1 years; p = 0.016). The general revision-free survival was 73% (95% CI 49.5 to 87.3) at 15 years and 38% (95% CI 11.8% to 64.3%) at 20 years, while MBG revision-free survival was 96.0% (95% CI 74.8% to 99.4%) at 15 years and 54% (95% CI 16.2% to 80.8%) at 20 years. Clinical scores showed a negative trend over time, although not statistically significant. Radiologically, polyethylene wear was observed in all cases and was complete in 12 out of 19 cases, and five glenoids were ‘at risk’ for loosening. Conclusion. At long-term follow-up, convertible MBG-TSA revealed a high rate of complications and revision surgery, mainly due to soft-tissue failure and polyethylene wear occurring with time. Prompt conversion to RSA maintaining the baseplate provided good results and a low complication rate. Radiological follow-up at about ten years is strictly recommended and, if metal-to-metal contact is observed, conversion to RSA is advisable. These results emphasize the need for continued research into improving TSA outcomes, especially in cases of MBG usage. Cite this article: Bone Jt Open 2025;6(1):82–92


Bone & Joint Open
Vol. 6, Issue 1 | Pages 35 - 42
8 Jan 2025
Fischer M Nonnenmacher L Hofer A Zimmerer A Nitsch A Großjohann R Erdmann S Wassilew GI

Aims. Periacetabular osteotomy (PAO) is well established for acetabular reorientation and has shown successful improvement in patient-reported outcome measures (PROMs). Nevertheless, studies focusing on postoperative outcomes related to patient individual factors are still underrepresented. Therefore, this study aimed to analyze the functional outcome and activity level in relation to patient sex with a minimum follow-up of two years after PAO for mild to severe hip dysplasia. Methods. A single-centre study was conducted, enrolling patients undergoing PAO and completing a preoperative and postoperative radiological and clinical outcome assessment. The PROMs were assessed using the modified Harris Hip Score (mHHS), the Hip disability and Osteoarthritis Outcome Score (HOOS) with the subscales for pain, sport, activities of daily living (ADL), and quality of life (QoL), and the University of California, Los Angeles (UCLA) activity score. Kendall’s tau were calculated for correlation analyses. Results. In total, 145 patients (28 male, 117 female) were included. The PROMs improved significantly across males and females at the latest follow-up. Female patients had significantly lower preoperative PROMs: mHHS (47 vs 57.4; p = 0.002); HOOS pain (44.9 vs 60; p = 0.003), sport (47 vs 57.4; p = 0.002), ADL (58.9 vs 69.3; p = 0.032), and QoL (26.8 vs 39.3; p = 0.009); and UCLA (5.6 vs 6.7, p = 0.042) scores. Males showed higher postoperative UCLA scores (7.5 vs 6.7; p = 0.03). Kendall’s tau showed significant negative correlation between BMI and UCLA scores in females and males (-0.21 to -0.29; p = 0.002/0.048), while BMI and HOOS sport (-0.16; p = 0.015) and ADL (-0.2; p = 0.003), as well as QoL (-0.14; p = 0.031) and preoperative acetabular inclination (-0.13; p = 0.049) were only significantly negatively correlated in females. Conclusion. Patient sex affects PROMs before and after PAO. Female patients experience higher improvement in hip function and activity level, due to poorer preoperative PROMs than males. Thus, these data are particularly interesting in providing preoperative guidance regarding postoperative outcome expectations. Cite this article: Bone Jt Open 2024;6(1):35–42


Bone & Joint Open
Vol. 6, Issue 1 | Pages 21 - 25
4 Jan 2025
Craven J O’Malley O Perry DC

Aims

This study aims to define a set of family-centred core outcomes for infants undergoing brace treatment to facilitate consistent reporting for future high-quality research.

Methods

Family-centred outcomes will be identified through a literature review and a scoping survey involving key stakeholders, including parents, healthcare professionals, and researchers. These outcomes will then be rated for their perceived importance in a two-stage modified Delphi process with the same stakeholders. Finally, a consensus meeting will be held to establish the final core outcome set (COS).


Bone & Joint Open
Vol. 6, Issue 1 | Pages 12 - 20
3 Jan 2025
Chan KCA Cheung A Chan P Luk MH Chiu KY Fu H

Aims. Around the world, the emergence of robotic technology has improved surgical precision and accuracy in total knee arthroplasty (TKA). This territory-wide study compares the results of various robotic TKA (R-TKA) systems with those of conventional TKA (C-TKA) and computer-navigated TKA (N-TKA). Methods. This is a retrospective study utilizing territory-wide data from the Clinical Data Analysis and Reporting System (CDARS). All patients who underwent primary TKA in all 47 public hospitals in Hong Kong between January 2021 and December 2023 were analyzed. Primary outcomes were the percentage use of various robotic and navigation platforms. Secondary outcomes were: 1) mean length of stay (LOS); 2) 30-day emergency department (ED) attendance rate; 3) 90-day ED attendance rate; 4) 90-day reoperation rate; 5) 90-day mortality rate; and 6) surgical time. Results. A total of 8,492 knees from 7,746 patients were included in the study. Overall robotic use had risen to 20.4% (2023 Q3 to Q4: 355/1,738) by the end of 2023, with Mako being the most popular at 10.3% (179/1,738). R-TKA had the shortest mean LOS compared with N-TKA and C-TKA (5.5 vs 6.3 and 7.1 days, respectively; p < 0.001). Only Mako (9.7%) demonstrated reduced 90-day ED attendance compared to C-TKA (13.1%; p = 0.009), Cori/Navio (15.0%; p = 0.005), and Rosa (16.4%; p < 0.001). No differences in 90-day reoperation rate and mortality were observed between all groups. Mean surgical times were longer in R-TKA groups by 20.6 minutes (p < 0.001). Conclusion. R-TKA use has increased in recent years, and has been shown to reduce hospital stay despite having a slightly longer surgical time, proving a promising candidate to alleviate the burden on healthcare systems. Individual differences between R-TKA systems contributed to variable clinical outcomes. Cite this article: Bone Jt Open 2024;6(1):12–20


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 34 - 41
1 Jan 2025
Tokuyasu H Kim Y Vergari C Tada H Tanaka C Takemoto M

Aims

Overall sagittal flexion is restricted in patients who have undergone both lumbar fusion and total hip arthroplasty (THA). However, it is not evident to what extent this movement is restricted in these patients and how this influences quality of life (QoL). The purpose of this study was to determine the extent to which hip-lumbar mobility is decreased in these patients, and how this affects their QoL score.

Methods

Patients who underwent primary THA at our hospital between January 2010 and March 2021 were considered (n = 976). Among them, 44 patients who underwent lumbar fusion were included as cases, and 44 THA patients without lumbar disease matched by age, sex, and BMI as Control T. Among those who underwent lumbar fusion, 44 patients without hip abnormalities matched by age, sex, and BMI to the cases were considered as Control F. Outcome and spinopelvic parameters were measured radiologically in extension and flexed-seated positions. Hip, lumbar, and hip-lumbar mobility were calculated as parameter changes between positions.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 58 - 64
1 Jan 2025
Carender CN Bedard NA Fruth KM Taunton MJ Pagnano MW Abdel MP

Aims

The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications.

Methods

We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 118 - 123
1 Jan 2025
Bavan L Bradley CS Verma Y Kelley SP

Aims

The primary aims of this study were to determine the time to sonographic correction of decentred hips during treatment with Pavlik harness for developmental dysplasia of the hip (DDH) and investigate potential risk factors for a delayed response to treatment.

Methods

This was a retrospective cohort study of infants with decentred hips who underwent a comprehensive management protocol with Pavlik harness between 2012 and 2016. Ultrasound assessments were performed at standardized intervals and time to correction from centring of the femoral head was quantified. Hips with < 40% femoral head coverage (FHC) were considered decentred, and hips with > 50% FHC and α angles > 60° were considered corrected. Survival analyses using log-rank tests and Cox regression were performed to investigate potential risk factors for delayed time to correction.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 124 - 132
1 Jan 2025
Thompson P Khattak M Joseph PJ Perry DC Cootes TF Lindner C

Aims

The aims of this study were to develop an automatic system capable of calculating four radiological measurements used in the diagnosis and monitoring of cerebral palsy (CP)-related hip disease, and to demonstrate that these measurements are sufficiently accurate to be used in clinical practice.

Methods

We developed a machine-learning system to automatically measure Reimer’s migration percentage (RMP), acetabular index (ACI), head shaft angle (HSA), and neck shaft angle (NSA). The system automatically locates points around the femoral head and acetabulum on pelvic radiographs, and uses these to calculate measurements. The system was evaluated on 1,650 pelvic radiographs of children with CP (682 females and 968 males, mean age 8.3 years (SD 4.5)). Each radiograph was manually measured by five clinical experts. Agreement between the manual clinical measurements and the automatic system was assessed by mean absolute deviation (MAD) from the mean manual measurement, type 1 and type 2 intraclass correlation coefficients (ICCs), and a linear mixed-effects model (LMM) for assessing bias.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 10 - 18
1 Jan 2025
Lewis TL Barakat A Mangwani J Ramasamy A Ray R

Hallux valgus (HV) presents as a common forefoot deformity that causes problems with pain, mobility, footwear, and quality of life. The most common open correction used in the UK is the Scarf and Akin osteotomy, which has good clinical and radiological outcomes and high levels of patient satisfaction when used to treat a varying degrees of deformity. However, there are concerns regarding recurrence rates and long-term outcomes. Minimally invasive or percutaneous surgery (MIS) has gained popularity, offering the potential for similar clinical and radiological outcomes with reduced postoperative pain and smaller scars. Despite this, MIS techniques vary widely, hindering comparison and standardization. This review evaluates the evidence for both open Scarf and Akin osteotomy and newer-generation MIS techniques. Fourth-generation MIS emphasizes multiplanar rotational deformity correction through stable fixation. While MIS techniques show promise, their evidence mainly comprises single-surgeon case series. Comparative studies between open and MIS techniques suggest similar clinical and radiological outcomes, although MIS may offer advantages in scar length and less early postoperative pain. MIS may afford superior correction in severe deformity and lower recurrence rates due to correcting the bony deformity rather than soft-tissue correction. Recurrence remains a challenge in HV surgery, necessitating long-term follow-up and standardized outcome measures for assessment. Any comparison between the techniques requires comparative studies. Surgeons must weigh the advantages and risks of both open and MIS approaches in collaboration with patients to determine the most suitable treatment.

Cite this article: Bone Joint J 2025;107-B(1):10–18.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 97 - 102
1 Jan 2025
Smeitink N Schröder FF Dorrestijn O Spekenbrink-Spooren A Govaert LHM Veen EJD

Aims

Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition.

Methods

Data from 280 shoulders with 159 primary HAs and 121 TSAs, which were undertaken in patients with atraumatic avascular necrosis of the humeral head between January 2014 and January 2023 from the Dutch Arthroplasty Register (LROI), were included. Kaplan-Meier survival analysis and Cox regression analysis were undertaken.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 81 - 88
1 Jan 2025
Rele S Shadbolt C Schilling C Thuraisingam S Trieu J Choong ELP Gould D Taylor NF Dowsey MM Choong PFM

Aims

The Clavien-Dindo (CD) classification and Comprehensive Complication Index (CCI) have been validated primarily among general surgical procedures. To date, the validity of these measures has not been assessed in patients undergoing arthroplasty.

Methods

This retrospective cohort study included patients undergoing primary total hip and knee arthroplasty between April 2013 and December 2019. Complications within 90 days of surgery were graded using the CD classification and converted to CCI. Validity was established by assessing the association between both measures and discharge to inpatient rehabilitation, length of stay, and costs.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 3 - 4
1 Jan 2025
Gelfer Y Ashby E Perry DC


Bone & Joint Open
Vol. 6, Issue 1 | Pages 3 - 11
1 Jan 2025
Shimizu A Murakami S Tamai T Haga Y Kutsuna T Kinoshita T Takao M

Aims

Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.

Methods

We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan. After propensity score matching, each group had 37 hips. Postoperative acetabular component position and orientation were measured using the planning module of the CT-based navigation system. Postoperative leg length and offset discrepancies were evaluated using postoperative CT in patients who have unilateral hip osteoarthritis.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 27 - 33
1 Jan 2025
Mc Donald S Yoong A Evans JT Farrow L

Aims

The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.

Methods

A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies based on registry data were analyzed separately.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1123 - 1129
20 Dec 2024
Manara JR Nixon M Tippett B Pretty W Collopy D Clark GW

Aims

Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized TKA alignment techniques. Functional alignment (FA) is a novel technique for performing a TKA and shares many principles with UKA. Our aim was to compare outcomes from a case-matched series of robotic-assisted UKAs and robotic-assisted TKAs performed using FA.

Methods

From a prospectively collected database between April 2015 and December 2019, patients who underwent a robotic-assisted medial UKA (RA-UKA) were case-matched with patients who had undergone a FA robotic-assisted TKA (RA-TKA) during the same time period. Patients were matched for preoperative BMI, sex, age, and Forgotten Joint Score (FJS). A total of 101 matched pairs were eligible for final review. Postoperatively the groups were then compared for differences in patient-reported outcome measures (PROMs), range of motion (ROM), ability to ascend and descend stairs, and ability to kneel.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 2 - 2
12 Dec 2024
Goel A Bidwai R Singh V Malaviya S Kumar K Cairns D Barker S Khan K
Full Access

Objective. We aimed to analyse the clinical outcomes and survivorship of anatomic total shoulder arthroplasty using a stemless humeral component with cemented pegged polyethylene glenoid performed with the technique of eccentric reaming to partially correct retroversion. These results were then compared with TSA using the same implant for end-stage shoulder arthritis with a normal version of the native glenoid. Design and methods. A retrospective case series was performed using a prospectively collected database of anatomic TSA patients operated at Woodend General Hospital, Aberdeen, UK. Between 2010 and 2019, 107 total shoulder arthroplasties (TSA) were done using standard anatomic stemless TSA implants (Affinis Short, Mathys Ltd, Bettlach, Switzerland) in 98 patients. Standardized preoperative and postoperative shoulder radiological imaging for glenoid retroversion was collected. Depending on the angle of native glenoid version, patients were divided into retroverted and non-retroverted glenoid as per the Walch Classification. To assess the radiological outcome at the final follow-up, radiolucency was assessed on the glenoid and humeral side using the Lazarus grading. The final clinical and radiologic outcome from the retroverted group was compared with the population with a non-retroverted glenoid. Five TSAs were excluded from the analysis as they did not have satisfactory postoperative radiographs. Hence, a total of 102 shoulders were available for analysis. Results. The mean follow-up was 3.48 years (2-10.2 years) in the retroverted group (n=44) and 3.9 years (2-8.9 years) in the non-retroverted group (n=58). The mean pre-operative retroversion of the glenoid in the retroverted group was 20.18, and the post-operative retroversion was 15.87, with a mean correction of 4.31. There was no significant difference between the two groups in the percentage of radiological loosening. The mean Oxford shoulder score was 41.4 (16-48) in the retroverted group, while it was 42.1 (20-48) in the non-retroverted group. Three patients in the retroverted group required revision surgery for rotator cuff failure. There were no revisions for aseptic loosening or instability. Conclusion. The degree of severity of retroversion of the glenoid was not associated with poor clinical outcomes, revisions, or failure in stemless TSA. At medium-term follow-up, partial correction of retroversion seems to provide comparable outcomes compared to a non-retroverted glenoid


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 12 - 12
12 Dec 2024
Langton D Bhalekar R Wells S Nargol M Natu S Nargol A Waller S Pabbruwe M Sidaginamale R
Full Access

Objectives. Several studies have reported elevated blood cobalt (Co) and chromium (Cr) concentrations in patients with total knee replacements (TKRs). Up to 44% of tissue samples taken from patients with failed TKRs exhibit histological evidence of metal sensitivity/ALVAL. In simulated conditions, metal particles contribute approximately 12% of total wear debris in TKR. We carried out this investigation to determine the source and quantity of metal release in TKRs. Design and Methods. We analysed 225 explanted fixed-bearing TKRs (Attune, Genesis II, NexGen, PFC, and Vanguard) revised for any indication. These were analysed using peer-reviewed [coordinate measuring machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D profilometry (surface roughness-Ra) and light microscopy. Histological and blood metal ion concentration analyses were performed in a sub-sample of patients. Results. The median (IQR) PE wear rate was 14 (6 to 20) mm. 3. /year. Microscopic examination of the superior surface of trays exhibited pitting on 132 (59%) of trays. There was a statistically significant (p<0.05) increase in Rvk on the pitted area of trays for each design, indicating material removal from the pits compared to the unpitted area. The inferior surface of 116(51%) of trays displayed polishing, indicative of abrasive wear. The median(range) Co and Cr concentrations were 2.5µg/l (0.2–69.4) and 1.7µg/l (0.5-12.5) respectively in 40 patients. Of the tissue samples examined in 30 patients, 6 had at least “mild”-ALVAL infiltrate. All corresponding “ALVAL” explants were found to be pitted and/or show evidence of loosening of the tray. Conclusion. This study provides further evidence that CoCr release in TKR appears to be an under-appreciated cause of adverse clinical outcomes. The generation of metal particles was predominantly from the metal tray, which may explain elevated metal ions after TKRs, despite no direct metal-on-metal contact


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 14 - 14
12 Dec 2024
Kakwani M Pujol-Nicolas A Griffiths A Hutt N Townshend D Murty A Kakwani R
Full Access

Objectives. Minimally invasive surgery (MIS) has gained popularity for hallux valgus, compared to the traditional scarf osteotomy (OS). Though evidence suggests similar clinical outcomes, there is paucity of randomised controlled studies. This study aimed to assess the feasibility of conducting a randomised controlled trial comparing the patient recorded and clinical outcomes for the surgical management of Hallux Valgus between OS and MIS Chevron Akin (MICA). Methods. Patients suitable for surgical correction were invited to participate. Post-op rehabilitation was standardised for both groups. Patients completed a validated questionnaire (Manchester Oxford Foot questionnaire and EQ-5D-5L) pre-operatively and post-operatively at 6 months and 1 year. Radiological parameters and range of motion were measured pre-and post-operatively. Results. 31 patients were recruited between Dec 2017 and June 2022. 17 patients were randomised to MICA (15 female, mean age 51) and 15 to OS (14 female, mean age 51). Both groups had a significant improvement in all MOXFQ parameters at 6m and 12m, as well as radiological parameters. VAS improved for OS (p=0.048) and for MICA (p=0.059) at 6m. There was no significant improvement in EQ-5D in either group at 12 months and no significant difference in operative time (p=0.53). There was a higher number of complications in the MICA group with 5 removal of metalwork (29.4%) and 2 superficial infections (11.8%) versus none in the OS group. The dorsiflexion significantly improved in the OS group at 6months (p=0.04). Recruitment rate dipped during COVID. No patients were lost at follow up. Conclusion. Both surgical options show similar clinical results, but higher complication rates were seen with MICA. This study illustrates the feasibility to conduct a randomised control trial for the comparison between the two techniques. Challenges to recruitment included surgeon equipoise, patient preference, training requirement and the pandemic which could be mitigated in a larger study


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1101 - 1107
11 Dec 2024
Haas-Lützenberger EM Emelianova I Bader MC Mert S Moellhoff N Demmer W Berger U Giunta R

Aims

In the treatment of basal thumb osteoarthritis (OA), intra-articular autologous fat transplantation has become of great interest within recent years as a minimally invasive and effective alternative to surgical intervention with regard to pain reduction. This study aims to assess its long-term effectiveness.

Methods

Patients diagnosed with stage one to three OA received a single intra-articular autologous fat transplantation. Fat tissue was harvested from the abdomen and injected into the trapeziometacarpal (TMC) joint under radiological guidance, followed by one week of immobilization. Patients with a minimum three-year post-procedure period were assessed for pain level (numerical rating scale), quality of life (Mental Health Quotient (MHQ)), the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH)), and grip and pinch strength, as well as their overall impression of the treatment. Wilcoxon tests compared data from pre-intervention, and at one and three years post-intervention.


Aims

Functional alignment (FA) in total knee arthroplasty (TKA) aims to achieve balanced gaps by adjusting implant positioning while minimizing changes to constitutional joint line obliquity (JLO). Although FA uses kinematic alignment (KA) as a starting point, the final implant positions can vary significantly between these two approaches. This study used the Coronal Plane Alignment of the Knee (CPAK) classification to compare differences between KA and final FA positions.

Methods

A retrospective analysis compared pre-resection and post-implantation alignments in 2,116 robotic-assisted FA TKAs. The lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were measured to determine the arithmetic hip-knee-ankle angle (aHKA = MPTA – LDFA), JLO (JLO = MPTA + LDFA), and CPAK type. The primary outcome was the proportion of knees that varied ≤ 2° for aHKA and ≤ 3° for JLO from their KA to FA positions, and direction and magnitude of those changes per CPAK phenotype. Secondary outcomes included proportion of knees that maintained their CPAK phenotype, and differences between sexes.