Advertisement for orthosearch.org.uk
Results 1 - 20 of 4591
Results per page:
Bone & Joint Research
Vol. 13, Issue 12 | Pages 779 - 789
16 Dec 2024
Zou H Hu F Wu X Xu B Shang G An D Qin D Zhang X Yang A

Aims

The involvement of long non-coding RNA (lncRNA) in bone marrow mesenchymal stem cell (MSC) osteogenic differentiation during osteoporosis (OP) development has attracted much attention. In this study, we aimed to disclose how LINC01089 functions in human mesenchymal stem cell (hMSC) osteogenic differentiation, and to study the mechanism by which LINC01089 regulates MSC osteogenesis.

Methods

Quantitative reverse transcription polymerase chain reaction (RT-qPCR) and western blotting were performed to analyze LINC01089, miR-1287-5p, and heat shock protein family A (HSP70) member 4 (HSPA4) expression. The osteogenic differentiation of MSCs was assessed through alkaline phosphatase (ALP) activity, alizarin red S (ARS) staining, and by measuring the levels of osteogenic gene marker expressions using commercial kits and RT-qPCR analysis. Cell proliferative capacity was evaluated via the Cell Counting Kit-8 (CCK-8) assay. The binding of miR-1287-5p with LINC01089 and HSPA4 was verified by performing dual-luciferase reporter and RNA immunoprecipitation (RIP) experiments.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 764 - 778
12 Dec 2024
Huang Q Zhuo Y Duan Z Long Y Wang J Zhang Z Fan S Huang Y Deng K Xin H

Aims

Mesenchymal stem cells (MSCs) are usually cultured in a normoxic atmosphere (21%) in vitro, while the oxygen concentrations in human tissues and organs are 1% to 10% when the cells are transplanted in vivo. However, the impact of hypoxia on MSCs has not been deeply studied, especially its translational application.

Methods

In the present study, we investigated the characterizations of human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) in hypoxic (1%) and normoxic (21%) atmospheres with a long-term culture from primary to 30 generations, respectively. The comparison between both atmospheres systematically analyzed the biological functions of MSCs, mainly including stemness maintenance, immune regulation, and resistance to chondrocyte apoptosis, and studied their joint function and anti-inflammatory effects in osteoarthritis (OA) rats constructed by collagenase II.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 10 - 10
12 Dec 2024
Fraser T Khalefa M Chesser T Ward A Acharya M
Full Access

Objectives. Acetabular fractures with quadrilateral plate involvement have been shown to have a high rate of complications. Anatomic suprapectineal plating systems have been developed to manage these injuries with good short-term outcomes, however long-term maintenance of anatomical reduction and functional outcomes is yet to be established. Efficacy of maintenance of reduction and functional outcomes at a minimum of 5-years follow-up is the aim of this study. Design and Methods. A retrospective cohort study examining patients aged over 16 years following fixation of acetabular fractures with quadrilateral plate involvement at a trauma centre in the United Kingdom. All patients had acetabular fracture fixation with an anatomically designed suprapectineal plate. Patients were admitted from March 2014 to January 2017. Primary outcomes included objective radiological outcomes such as reduction quality, maintenance of reduction, metalwork failure, complications (such as reoperation, neurological deficit and mortality) and subjective patient-related outcome measures (PROMs) using the Oxford Hip Score and EuroQol EQ5D Score at a minimum of 5-years post-operatively. Results. 16 patients met our eligibility criteria in this cohort. Post-operative mean Oxford Hip Score (OHS) at a minimum of 5-years was 40.5 (SD 11.9) with a median score of 45. Post-operative mean EuroQol EQ-5D scores at a minimum of 5-years were 0.83 (SD 0.25). Comparison of OHS and EQ5D at 1-year and 5-years showed no significant difference (OHS p = 0.27 / EQ5D p = 0.128). Radiographic outcomes were assessed with AP and Judet plain radiographs at a minimum of 5-years follow-up. Rate of conversion to total hip replacement was 6.25%. 56.3% showed some evidence of dome comminution with 18.8% demonstrating dome impaction. 93.7% showed evidence of quadrilateral plate involvement. 12.5% showed evidence of femoral head injury. Conclusion. Maintenance of reduction and functional and patient reported outcomes using anatomically contoured suprapectineal plates do not change significantly between 1 year and 5 years follow-up


Bone & Joint Research
Vol. 13, Issue 12 | Pages 741 - 749
6 Dec 2024
Blichfeldt-Eckhardt MR Varnum C Lauridsen JT Rasmussen LE Mortensen WCP Jensen HI Vaegter HB Lambertsen KL

Aims

Better prediction of outcome after total hip arthroplasty (THA) is warranted. Systemic inflammation and central neuroinflammation are possibly involved in progression of osteoarthritis and pain. We explored whether inflammatory biomarkers in blood and cerebrospinal fluid (CSF) were associated with clinical outcome, and baseline pain or disability, 12 months after THA.

Methods

A total of 50 patients from the Danish Pain Research Biobank (DANPAIN-Biobank) between January and June 2018 were included. Postoperative outcome was assessed as change in Oxford Hip Score (OHS) from baseline to 12 months after THA, pain was assessed on a numerical rating scale, and disability using the Pain Disability Index. Multiple regression models for each clinical outcome were included for biomarkers in blood and CSF, respectively, including age, sex, BMI, and Kellgren-Lawrence score.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 716 - 724
4 Dec 2024
Cao S Chen Y Zhu Y Jiang S Yu Y Wang X Wang C Ma X

Aims

This cross-sectional study aimed to investigate the in vivo ankle kinetic alterations in patients with concomitant chronic ankle instability (CAI) and osteochondral lesion of the talus (OLT), which may offer opportunities for clinician intervention in treatment and rehabilitation.

Methods

A total of 16 subjects with CAI (eight without OLT and eight with OLT) and eight healthy subjects underwent gait analysis in a stair descent setting. Inverse dynamic analysis was applied to ground reaction forces and marker trajectories using the AnyBody Modeling System. One-dimensional statistical parametric mapping was performed to compare ankle joint reaction force and joint moment curve among groups.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1485 - 1492
1 Dec 2024
Terek RM

Aims. The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device. Methods. A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively. Results. The mean VAS pain score decreased significantly from 84 (SD 15) to 50 (SD 29), 38 (SD 30), 31 (SD 29), 31 (SD 29), and 21 (SD 23) between the baseline and follow-up times (p < 0.001). The mean MSTS function scores significantly increased from 27 (SD 19) to 52 (SD 22), 60 (23), 67 (SD 23), 72 (SD 26), and 83 (SD 14) (p < 0.001). The pain and functional subscales of the QLQ-BM22 also significantly improved at most times. A total of 12 devices broke, giving an unadjusted device fracture rate of 15%. Conclusion. Stabilization with the IS decreased pain and improved function with consistent results during the first postoperative year. IS is a new, minimally invasive type of internal fixation. The use of the IS alone may be better for impending rather than completed pathological fractures, and may be better in completed fractures if an added plate or more than the usual number of locking screws is required. Caution is warranted regarding its use alone in patients with a completed pathological fracture due to the rate of breakage of the device. Cite this article: Bone Joint J 2024;106-B(12):1485–1492


Bone & Joint Research
Vol. 13, Issue 12 | Pages 695 - 702
1 Dec 2024
Cordero García-Galán E Medel-Plaza M Pozo-Kreilinger JJ Sarnago H Lucía Ó Rico-Nieto A Esteban J Gomez-Barrena E

Aims

Electromagnetic induction heating has demonstrated in vitro antibacterial efficacy over biofilms on metallic biomaterials, although no in vivo studies have been published. Assessment of side effects, including thermal necrosis of adjacent tissue, would determine transferability into clinical practice. Our goal was to assess bone necrosis and antibacterial efficacy of induction heating on biofilm-infected implants in an in vivo setting.

Methods

Titanium-aluminium-vanadium (Ti6Al4V) screws were implanted in medial condyle of New Zealand giant rabbit knee. Study intervention consisted of induction heating of the screw head up to 70°C for 3.5 minutes after implantation using a portable device. Both knees were implanted, and induction heating was applied unilaterally keeping contralateral knee as paired control. Sterile screws were implanted in six rabbits, while the other six received screws coated with Staphylococcus aureus biofilm. Sacrifice and sample collection were performed 24, 48, or 96 hours postoperatively. Retrieved screws were sonicated, and adhered bacteria were estimated via drop-plate. Width of bone necrosis in retrieved femora was assessed through microscopic examination. Analysis was performed using non-parametric tests with significance fixed at p ≤ 0.05.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 36 - 39
1 Dec 2024

The December 2024 Trauma Roundup. 360. looks at: Percutaneous lumbopelvic fixation is effective in the management of unstable transverse sacral fractures; A systematic review on autologous matrix-induced chondrogenesis (AMIC) for chondral knee defects; Stable clinical and radiological outcomes at medium and over five-year follow-up of calcaneus fracture open reduction internal fixation using a sinus tarsi approach; Right or left? It might make a difference; Suprapatellar versus infrapatellar tibial nailing – is there a difference in anterior knee pain and function?; Can patients safely weightbear following ankle fracture fixation?; Anterior-to-posterior or a plate fixation for posterior malleous fractures?; Audio distraction for traction pin insertion: a prospective randomized controlled study; Is intramedullary nailing of femoral diaphyseal fractures in the lateral decubitus position as safe and effective as on a traction table?


Bone & Joint 360
Vol. 13, Issue 6 | Pages 41 - 44
1 Dec 2024

The December 2024 Children’s orthopaedics Roundup. 360. looks at: Establishing best practice for managing idiopathic toe walking in children: a UK consensus; Long-term outcomes of below-elbow casting in paediatric diaphyseal forearm fractures; Residual dysplasia risk persists in developmental dysplasia of the hip patients after Pavlik harness treatment; 3D printing in paediatricorthopaedics: enhancing surgical efficiency and patient outcomes; Pavlik harness treatment for hip dysplasia does not delay motor skill development in children; High prevalence of hip dysplasia found in adolescents with idiopathic scoliosis on routine spine radiographs; Minifragment plates as effective growth modulation for ulnar deformities of the distal radius in children; Long-term success of Chiari pelvic osteotomy in preserving hip function: 30-year follow-up study


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1431 - 1442
1 Dec 2024
Poutoglidou F van Groningen B McMenemy L Elliot R Marsland D

Lisfranc injuries were previously described as fracture-dislocations of the tarsometatarsal joints. With advancements in modern imaging, subtle Lisfranc injuries are now more frequently recognized, revealing that their true incidence is much higher than previously thought. Injury patterns can vary widely in severity and anatomy. Early diagnosis and treatment are essential to achieve good outcomes. The original classification systems were anatomy-based, and limited as tools for guiding treatment. The current review, using the best available evidence, instead introduces a stability-based classification system, with weightbearing radiographs and CT serving as key diagnostic tools. Stable injuries generally have good outcomes with nonoperative management, most reliably treated with immobilization and non-weightbearing for six weeks. Displaced or comminuted injuries require surgical intervention, with open reduction and internal fixation (ORIF) being the most common approach, with a consensus towards bridge plating. While ORIF generally achieves satisfactory results, its effectiveness can vary, particularly in high-energy injuries. Primary arthrodesis remains niche for the treatment of acute injuries, but may offer benefits such as lower rates of post-traumatic arthritis and hardware removal. Novel fixation techniques, including suture button fixation, aim to provide flexible stabilization, which theoretically could improve midfoot biomechanics and reduce complications. Early findings suggest promising functional outcomes, but further studies are required to validate this method compared with established techniques. Future research should focus on refining stability-based classification systems, validation of weightbearing CT, improving rehabilitation protocols, and optimizing surgical techniques for various injury patterns to ultimately enhance patient outcomes.

Cite this article: Bone Joint J 2024;106-B(12):1431–1442.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 64 - 64
22 Nov 2024
Mbuku RB Poilvache H Van Bambeke F Cornu O
Full Access

Aim. The management of PJIs is slowed down by the presence of bacteria forming biofilms where they may withstand antibiotic therapy. The use of adjuvant strategies, such as hydrolytic enzymes cocktail targeting biofilm matrices and facilitating their dispersion, is a promising option to limit impact of biofilms. Our aim was to evaluate the effect of enzymes cocktail combined with antibiotic dual therapy of rifampicin and vancomycin in a relevant in-vitro model. Method. Mature methicillin-resistant Staphylococcus aureus biofilms were grown on Ti-6Al-4V coupons by adding 1mL of a 8Log10 ATCC 33591 suspension in TGN (TSB + 1% glucose + 2% NaCl) to 24-wells plates containing the coupons and incubating the plates for 24h at 37°C with a continuous 50rpm agitation. The samples were rinsed and placed in 6 wells plates containing 1ml of the enzymatic cocktail (C.D.D.) solution (tris-buffered (pH 7.0) solution of 400 U/ml of aspecific DNA/RNA endonuclease, 50 U/ml of endo-1,4-b-D-glucanase, and 0.06 U/ml of β-N-acetylhexosaminidase). 9ml of TGN or TGN containing antibiotics RIF/VAN (rifampicin 5µg/mL + vancomycin 8µg/mL) at clinically relevant concentrations found locally in bone or joints, was then added and the samples were incubated in identical conditions for 24h. The samples were then recovered and rinsed. CFU counts were obtained by recovering the bacteria with sonication, serial dilutions, and TSA plating. Biomass was determined via crystal violet staining, followed by dye solubilization in acetic acid, and absorbance measurement using a spectrophotometer. Results. Significant reductions in bacterial counts were observed in biofilms exposed to either RIF/VAN or RIF/VAN+CDD, by respectively 2,6 and 3,7Log10 when compared to samples reincubated with TGN alone (p <0.05). Additionally, CFU counts in samples exposed to RIF/VAN+CDD were reduced by 1,1Log10 when compared to those exposed to RIF/VAN (p<0,05). Significant reduction in biomass (-29,8%, p<0.05) was observed for coupons exposed to RIF/VAN+CDD when compared to C.D.D alone (figure 1). Conclusions. The concurrent utilization of enzymes with rifampicin and vancomycin, holds promise as a feasible method to address periprosthetic joint infections (PJIs). For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 1 - 1
22 Nov 2024
McNally M Frank F Hotchen A Valand P Stubbs D Ferguson J
Full Access

Aim. This is the first study to directly compare the clinical outcome of debridement, antimicrobials and implant retention (DAIR) with stabilization using new internal fixation after debridement, for patients with Fracture-related Infection (FRI). Method. Consecutive patients with FRI Consensus confirmed FRI had single-stage surgery with tissue sampling, debridement, stabilization, antimicrobial therapy and skin closure. All cases had FRIs which were unhealed at surgery. When existing implants were stable, the implant was retained but loose implants or fractures with poor reduction had implant removal and refixation with new implants. All patients had the same empiric and definitive antibiotics, the same diagnostic criteria and outcome assessment at least one year after surgery. Failure was defined as infection recurrence, reoperation or lack of fracture consolidation at one year. Results. Seventy-one patients were studied (40 DAIRs and 31 new implants, including 10 exchange nails). The two groups were well matched for age, duration of infection, BACH complexity, microbiology, bone involved and need for flap coverage. Ten patients (13.7%) died before the endpoint. Mortality was similar in both groups (DAIR 14.1% vs New Metalware 12.9%; p=0.801) but DAIR of IM nails had a higher mortality at 40% (p=0.011). Sixty-one patients were followed-up for a mean of 3.32 years (1.04-9.43). Infection was eradicated in 23/34 (67.6%) DAIR patients and 24/27 (88.9%) with new metalware (p=0.049). Overall rates of infection-free union were similar in both groups (58.8% vs 77.8%; p=0.117). DAIR of plates had significantly fewer infection-free unions compared to removal and implantation of new plates (DAIR 57.1% vs NM 91.7%; p=0.033). Conclusion. Implantation of new metalware had better eradication of infection and a strong trend towards better union rates. Treating FRI with retained or new metalware had a substantial mortality (13.7%). Choosing DAIR did not reduce this mortality and these patients more often required further surgery to treat residual infection and secure union


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 69 - 69
22 Nov 2024
De Vecchi E Riccardi M Mastroianni N
Full Access

Aim. Diagnosis of prosthetic joint infection are often complicated by the presence of biofilm, which hampers bacteria dislodging from the implants, thus affecting sensitivity of cultures. In the last 20 years several studies have evidenced the usefulness of implant sonication to improve microbial recovery from biofilm formed on inert substrates. More recently, treatment of prosthetic joints and tissues with Dithiothreitol, a sulphur compound already used in routine diagnostic workflow for fluidification of respiratory samples, has proved to be not inferior to sonication in microbiological diagnosis of prosthetic joint infections. This study aimed to evaluate if the combination of the two treatments could further improve microbial retrieval from biofilm in an in vitro model. Method. Three isolates of Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus lugdunensis, Eschericha coli and Pseudomonas aeruginosa responsible of prosthetic joint infections were used. They were grown onto 3 titanium discs (20 mm diameter) and incubated in 3 sterile plastic containers with 15 mL of Triptyc Soy Broth. After overnight incubation, not adhered cells were removed and fresh broth was added to each sample. After 48 hours incubation, the exausted broth was removed and one sample was used for sonication, one for treatment with 0,1% (v:v) Dithiothreitol and one treated with Dithiothreitol followed by sonication. Treated fluids were plated on Muller Hinton Agar plates for colony count. One-way ANOVA analysis was performed to evidence statistical differences between treatments. Results. Similar colony counts were observed for the 3 treatments: 10.1± 0.77 log CFU/mL for Dithiothreitol, 10.0 ± 0.75 for sonication and 10.1 ±0.73 for dithiothreitol + sonication. No statistical differences between the 3 treatments were evidenced by ANOVA analysis. Conclusions. Results seems to confirm that treatment with dithiothreitol is equivalent to sonication in recovering bacteria from biofilm grown on inert surface. Combining dithiotreitol treatment with sonication does not significantly improve bacterial recovery in respect to each treatment alone


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 3 - 3
22 Nov 2024
Samuel BJ Horbert V Jin Z Brauer DS Matziolis G
Full Access

Aim. Biomaterial-associated infections (BAI) present a formidable clinical challenge. Bioactive glasses (BG) have proven highly successful in diverse clinical applications, especially in dentistry and orthopaedics. In this study, we aimed to determine the effect of three commonly used BG composition and particle sizes on cell and bacterial attachment and growth. Our focus is on understanding the changes in pH and osmotic pressure in the surrounding environment during glass degradation. Method. First, three different melt-derived glasses were characterized by analyzing particle size and glass network structure using Raman and NMR. The different glasses were then tested in vitro by seeding 4x 10. 4. cells/well (SaOS Cell line) in a 48 well plate. After a pre-incubation period of 72 hours, the different BGs and particle sizes were added to the cells and the pH value, ion release and live/dead staining was measured every hour. The effect of BG against bacteria (S. epidermidis) was analyzed after 24 and 72 hours of treatment by using XTT viability assay and CFU counting by plating out the treated aliquot agar to estimate the viable bacteria cells. Results. All three BG compositions tested showed a significant increase in pH, which was highest in BG composition 45S5 with a value of 11 compared to the other BG compositions 10 and 9 in S53P4 and 13-93 respectively. This strong increase in the pH in all BG samples tested results in a strongly reduced cell viability rate of more than 75% compared to the untreated control and 6-fold reduction in bacterial viability compared to the untreated control. The live/ dead assay also showed an increased cell viability with increasing glass particle size (i. e smallest glass particle < 25% viable cell and largest glass particle> 65% viable cell). The ion release concentration over 50 h showed an increase in sodium ions to 0.25 mol/L, calcium to 0.003 mol/L and a decrease in phosphorus. Conclusions. These results show that the composition of the bioactive glass and the choice of particle size have a major influence on subsequent applications. In addition to the different compositions of the BG, particle size and additional medium change also influence the pH and ion release, and therefore also on cells or bacteria viability. The sizes of the bioactive glass particle are inversely proportional to it. Further tests are necessary to develop custom design BG compositions, which simultaneously stimulate osteoblasts proliferation and prevent microbial adhesion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 40 - 40
22 Nov 2024
Chao C Khilnani T Jo S Yang X Bostrom M Carli A
Full Access

Aim. Periprosthetic joint infection (PJI) is a complication of total joint arthroplasty that typically requires revision surgery for treatment. Systemic antibiotics are usually held prior to surgery to improve yield of intraoperative cultures. However, recent studies suggest that preoperative aspirations have a high concordance with intraoperative cultures, which may allow surgeons to initiate antibiotic treatment earlier. The purpose of the study was to investigate the effect of Pre-surgical systemic antibiotic therapy on the bacterial burden within the periprosthetic space and systemic immune reaction. Method. PJI was induced with MSSA (Xen36) S. aureus in the right knee of 16-week old, female, C57BL6 mice using a previously validated murine model. Mice were randomized to three groups (n=8, each): control; Vanc, receiving systemic vancomycin (110mg/kg, SQ, twice daily); or VancRif receiving vancomycin same as in Vanc group, plus rifampin (12mg/kg dose, IV, once daily). Following 2 weeks of treatment, mice were euthanized and periprosthetic bone, soft tissue and the implant were harvested. Bacterial burden, colony forming units (CFUs), was quantified in soft tissue, tibial bone, and on the implant. Specifically, tissues were homogenized and serially plated for CFUs, while the implant was sonicated and then plated for CFUs. The host immune response was analysed through weighing inguinal and iliac lymph nodes and through measuring serum amyloid A (SAA). Non-parametric pairwise group comparisons of the three outcome measures were performed using a Mann-Whitney U test. Results. VancRif, the combined treatment significantly reduced bacterial burden in the periprosthetic soft tissue, bone, and implant compared to control (p<0.001) and Vanc alone (p<0.001). While not significant, Vanc alone did reduce bacterial load as compared to control. The ipsilateral weight of the iliac lymph nodes was significantly reduced in Vanc and VancRif mice compared to controls (p<0.001), was well as in VancRif versus Vanc alone (p<0.001). Interestingly, SAA levels did not significantly differ among all groups. During tissue harvesting, minimal purulence was observed in antibiotic treatment groups, unlike controls. Conclusions. Treating active PJI with vancomycin alone decreases periprosthetic bacterial loads and reduces the local immunological response. This effect is significantly enhanced with the combined rifampin use. These findings could suggest that when culture positive PJI is diagnosed, pre-surgical treatment with antibiotics may decrease immunosuppression and soft tissue infiltration, leading to a better chance of infection cure with subsequent surgical debridement. Histological investigations and repeat experiments involving subsequent surgical treatment are underway. Acknowledgements. Funding comes from internal institutional grants


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 62 - 62
22 Nov 2024
Mueller MM Kowald B Gerlach U Grimme C Schulz A Frosch K Schoop-Schmetgens R
Full Access

Aim. Aim of this study was to establish the first clinical results after implantation of ultrathin silver-polysiloxane-coated. 1. plates in the treatment of infected non-union of the femoral shaft. Method. As part of the REFECT study, a prospective, non-interventional analysis was conducted encompassing all patients who received internal stabilization with a silver-coated. 1. plate from 01/2023 to 09/2024 as part of the treatment for infected non-union of the femur. Standardized clinical follow-ups including PROMs (WOMAC-Index, LEF-S, EQ-5D, VAS) and X-rays were performed 3, 6, 12 (and 24) months postoperatively. For comparison, a retrospective analysis of 76 patients with infected femoral non-union, who had received a stabilization with an uncoated plate in the past 10 years, was performed. Results. The mean follow-up of the 8 included patients (mean bone defect: 3.6 cm) was 9 months (as of 04/24). Multiresistant bacteria were found in the intraoperative samples of 5 patients. The concentration of silver ions in blood serum reached a maximum of 0.014 mg/l in the laboratory controls. All patients showed a positive healing process with no sign of re-infection and no adverse procedure-associated events. Full weight bearing was achieved after an average of 4 months (n=6) with improved WOMAC-, LEF-S-, EQ-5D and VAS-score at 1-year FU. In the reference group (uncoated, mean FU: 3.5 years), there was a re-infection rate of 25 %, mostly in the first 2 years. Difficult-to-treat bacteria were detected in 22%, multiresistant Staph. epidermidis in 28% of cases. Conclusions. -. The silver-coated. 1. implants showed good biocompatibility with no evidence of procedure-associated complications. -. The use of silver-coated. 1. implants could reduce the risk of re-infection. -. Further clinical data with longer follow-up are needed to assess the long-term value of the procedure


Bone & Joint Research
Vol. 13, Issue 11 | Pages 659 - 672
20 Nov 2024
Mo H Sun K Hou Y Ruan Z He Z Liu H Li L Wang Z Guo F

Aims

Osteoarthritis (OA) is a common degenerative disease. PA28γ is a member of the 11S proteasome activator and is involved in the regulation of several important cellular processes, including cell proliferation, apoptosis, and inflammation. This study aimed to explore the role of PA28γ in the occurrence and development of OA and its potential mechanism.

Methods

A total of 120 newborn male mice were employed for the isolation and culture of primary chondrocytes. OA-related indicators such as anabolism, catabolism, inflammation, and apoptosis were detected. Effects and related mechanisms of PA28γ in chondrocyte endoplasmic reticulum (ER) stress were studied using western blotting, real-time polymerase chain reaction (PCR), and immunofluorescence. The OA mouse model was established by destabilized medial meniscus (DMM) surgery, and adenovirus was injected into the knee cavity of 15 12-week-old male mice to reduce the expression of PA28γ. The degree of cartilage destruction was evaluated by haematoxylin and eosin (HE) staining, safranin O/fast green staining, toluidine blue staining, and immunohistochemistry.


Introduction. The evaluation of treatment modalities for distal femur periprosthetic fractures (DFPF) post-total knee arthroplasty (TKA) has predominantly focused on functional and radiological outcomes in existing literature. This study aimed to comprehensively compare the functional and radiological efficacy of locking plate (LP) and retrograde intramedullary nail (IMN) treatments, while incorporating mortality rates. Method. Twenty patients (15 female, 5 male) with a minimum 24-month follow-up period, experiencing Lewis-Rorabeck type-2 DFPF after TKA were included. These patients underwent either LP (n=10) or IMN (n=10). The average follow-up duration was 48 months (range: 24–192). Treatment outcomes, including functional scores, alignment, union time, complications, and mortality rates, were assessed and compared between LP and IMN groups. Clinical examination findings pre-treatment and at final follow-up, along with two-way plain radiographs, were utilized. Statistical analyses comprised Student's t-test and Kaplan-Meier survival analysis with a 95% confidence interval. Result. At final follow-up, the LP group demonstrated a mean Knee Society score of 67.2 ± 16.1, while the IMN group exhibited a score of 72.8 ± 9.4(P = 0.58). No statistically significant differences were observed in alignment between the groups[aLDFA (anatomical lateral distal femoral angle), P = 0.31; aPDFA (anatomical posterior distal femoral angle), P = 0.73]. The mean time to union was 3.7 ± 0.8 months for LP and 3.9 ± 0.6 months for IMN (P = 0.62). Complications such as infection occurred in 1 LP patient, and non-union was observed in 2 LP patients, while no complications were noted in IMN group(P < 0.01). Mortality rates were notably lower in the IMN group compared to the LP group across various time intervals. Conclusion. Both LP and IMN treatments yielded similar functional scores, alignment, and union time for DFPF post-TKA. However, the lower incidence of complications and mortality rates associated with IMN treatment suggest its superiority in managing DFPF following TKA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 10 - 10
14 Nov 2024
Zderic I Kraus M Rossenberg LV Puls L Pastor T Gueorguiev B Richards G Pape HC Pastor T
Full Access

Introduction. The main postoperative complications in fixation of ulna shaft fractures are non-union and implant irritation using currently recommended 3.5-mm locking compression plates. An alternative approach using a combination of two smaller plates in orthogonal configuration has been proposed. The aim of this study was to compare the biomechanical properties of a single 3.5-mm locking compression plate versus double plating using one 2.5-mm and one 2.0-mm mandible plate in a human ulna shaft fracture model. Method. Eight pairs human ulnar specimens with a standardized 10-mm fracture gap were pairwise assigned for instrumentation with either a single 3.5-mm plate placed posteriorly, or for double plating using a 2.5-mm and a 2.0-mm mandible plate placed posteriorly under the flexor muscles and laterally under the extensor muscles. All constructs were initially non-destructively biomechanically tested in axial compression, torsion, and bending, which was followed by cyclic torsional loading to failure. Interfragmentary movements were monitored by means of optical motion tracking. Result. There were no significant differences between the two plating techniques for axial stiffness (p=0.335), torsional stiffness in supination (p=0.462), torsional stiffness in pronation (p=0.307), medio-lateral bending stiffness (p=0.522), and antero-posterior bending stiffness (p=0.143). During cyclic torsional loading over the first 3000 cycles, there were no significant differences between the two plating techniques for shear displacement across the fracture gap, p=0.324. The numbers of cycles until clinically relevant failure of 5° angular deformation were 1366±685 for double plating and 2024±958 for single plating, which was statistically non-significantly different, p>0.05. The constructs treated with both plating techniques failed due to bone breakage at the most distal screw. Conclusion. From a biomechanical perspective double plating of ulna shaft fractures using a 2.5-mm and a 2.0-mm locking mandible plate demonstrated equivalent fixation strength as conventional plating using a single 3.5-mm locking compression plate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 64 - 64
14 Nov 2024
Hudson P Federer S Dunne M Pring C Smith N
Full Access

Introduction. Weight is a modifiable risk factor for osteoarthritis (OA) progression. Despite the emphasis on weight loss, data quantifying the changes seen in joint biomechanics are limited. Bariatric surgery patients experience rapid weight loss. This provides a suitable population to study changes in joint forces and function as weight changes. Method. 10 female patients undergoing gastric bypass or sleeve gastrectomy completed 3D walking gait analysis at a self-selected pace, pre- and 6 months post-surgery. Lower limb and torso kinematic data for 10 walking trials were collected using a Vicon motion capture system and kinetics using a Kistler force plate. An inverse kinematic model in Visual 3D allowed for no translation of the hip joint centre. 6 degrees of freedom were allowed at other joints. Data were analysed using JASP with a paired samples t-test. Result. On average participants lost 28.8±7.60kg. No significant changes were observed in standing knee and hip joint angles. Walking velocity increased from 1.10±0.11 ms. -1. to 1.23±0.17 ms. -1. (t(9)=-3.060, p = 0.014) with no change in step time but a mean increase in stride length of 0.12m (SE: 0.026m; t(9)=-4.476, p = 0.002). A significant decrease of 21.5±4.2% in peak vertical ground reaction forces was observed (t(9)=12.863, p <0.001). Stride width significantly decreased by 0.04m (SE: 0.010m; t(9)=4.316, p = 0.002) along with a decrease in lateral impulse of 21.2Ns (SE: 6.977Ns; t(7), p = 0.019), but no significant difference in knee joint angles were observed. Double limb support time also significantly reduced by 0.02s (SE: 0.006s; t(9) = 3.639, p=0.005). Conclusion. The reduction in stance width and lateral impulse suggests a more sagittal compass-gait walk is being achieved. This would reduce valgus moments on the knee reducing loading in the medial compartment. The reduction in peak ground reaction force would reduce knee contact forces and again potentially slow OA progression