Aims. Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized TKA alignment techniques. Functional alignment (FA) is a novel technique for performing a TKA and shares many principles with UKA. Our aim was to compare outcomes from a case-matched series of robotic-assisted UKAs and robotic-assisted TKAs performed using FA. Methods. From a prospectively collected database between April 2015 and December 2019, patients who underwent a robotic-assisted medial UKA (RA-UKA) were case-matched with patients who had undergone a FA robotic-assisted TKA (RA-TKA) during the same time period. Patients were matched for preoperative BMI, sex, age, and Forgotten Joint Score (FJS). A total of 101 matched pairs were eligible for final review. Postoperatively the groups were then compared for differences in patient-reported outcome measures (PROMs), range of motion (ROM), ability to ascend and descend stairs, and ability to kneel.
Aims. The free latissimus dorsi muscle (LDM) flap represents a workhorse procedure in the field of trauma and plastic surgery. However, only a small number of studies have examined this large group of patients with regard to the morbidity of flap harvest. The aim of this prospective study was therefore to objectively investigate the morbidity of a free LDM flap. Methods. A control group (n = 100) without surgery was recruited to assess the differences in strength and range of motion (ROM) in the shoulder joint with regard to handedness of patients. Additionally, in 40 patients with free LDM flap surgery, these parameters were assessed in an identical manner.
Aims. Arthroplasty has been shown to generate the most waste among all orthopaedic subspecialties, and it is estimated that hip and knee arthroplasty generate in excess of three million kg of waste annually in the UK. Infectious waste generates up to ten times more CO2 compared with recycled waste, and previous studies have shown that over 90% of waste in the infectious stream is misallocated. We assessed the effect of real-time waste segregation by an unscrubbed team member on waste generation in knee and hip arthroplasty cases, and compared this with a simple educational intervention during the ‘team brief’ at the start of the operating list across two sites. Methods. Waste was categorized into five categories: infectious, general, recycling, sharps, and linens. Each category was weighed at the end of each case using a digital weighing scale. At Site A (a tertiary orthopaedic hospital), pre-intervention data were collected for 16 total knee arthroplasy (TKA) and 15 total hip arthroplasty (THA) cases. Subsequently, for ten TKA and ten THA cases, an unscrubbed team member actively segregated waste in real-time into the correct streams. At Site B (a district general hospital), both pre- and post-intervention groups included ten TKA and ten THA cases. The intervention included reminding staff during the ‘team brief’ to segregate waste correctly.
Cite this article:
Aims. The involvement of long non-coding RNA (lncRNA) in bone marrow mesenchymal stem cell (MSC) osteogenic differentiation during osteoporosis (OP) development has attracted much attention. In this study, we aimed to disclose how LINC01089 functions in human mesenchymal stem cell (hMSC) osteogenic differentiation, and to study the mechanism by which LINC01089 regulates MSC osteogenesis. Methods. Quantitative reverse transcription polymerase chain reaction (RT-qPCR) and western blotting were performed to analyze LINC01089, miR-1287-5p, and heat shock protein family A (HSP70) member 4 (HSPA4) expression. The osteogenic differentiation of MSCs was assessed through alkaline phosphatase (ALP) activity, alizarin red S (ARS) staining, and by measuring the levels of osteogenic gene marker expressions using commercial kits and RT-qPCR analysis. Cell proliferative capacity was evaluated via the Cell Counting Kit-8 (CCK-8) assay. The binding of miR-1287-5p with LINC01089 and HSPA4 was verified by performing dual-luciferase reporter and RNA immunoprecipitation (RIP) experiments.
Objective. We aimed to analyse the clinical outcomes and survivorship of anatomic total shoulder arthroplasty using a stemless humeral component with cemented pegged polyethylene glenoid performed with the technique of eccentric reaming to partially correct retroversion. These results were then compared with TSA using the same implant for end-stage shoulder arthritis with a normal version of the native glenoid. Design and methods. A retrospective case series was performed using a prospectively collected database of anatomic TSA patients operated at Woodend General Hospital, Aberdeen, UK. Between 2010 and 2019, 107 total shoulder arthroplasties (TSA) were done using standard anatomic stemless TSA implants (Affinis Short, Mathys Ltd, Bettlach, Switzerland) in 98 patients. Standardized preoperative and postoperative shoulder radiological imaging for glenoid retroversion was collected. Depending on the angle of native glenoid version, patients were divided into retroverted and non-retroverted glenoid as per the Walch Classification. To assess the radiological outcome at the final follow-up, radiolucency was assessed on the glenoid and humeral side using the Lazarus grading. The final clinical and radiologic outcome from the retroverted group was compared with the population with a non-retroverted glenoid. Five TSAs were excluded from the analysis as they did not have satisfactory postoperative radiographs. Hence, a total of 102 shoulders were available for analysis.
Objectives. Our aim to study the incidence, demographics, inpatient stay, use of imaging and outcomes of patients who have non-operatively managed NOF fractures. Study Design & Methods. The data was collected retrospectively for the last 14 years (Jan 2009- Jan 2023) of all non-operatively managed NOF fractures at a level 2 trauma centre. The data was collected from the trauma board, electronic patient records, radiographs, and National Hip Fracture Database (NHFD). The data collected as demographic details, fracture classification, any reasons for non-operative management, mortality and further surgical management was done. Patients who died or transferred to other sites for specialist surgery were excluded.
Objectives. Distal humerus fractures in elderly population are often comminuted and presents multiple challenges. When managed with fixation the results are often complicated with stiffness, pain, and reduced function while total elbow replacement is fraught with lifelong restrictions on load bearing which can significantly affect elderly patients who rely assistive devices for ambulation. Elbow hemiarthroplasty however, presents a viable alternative in these cases. This series evaluates the results of the distal humerus hemiarthroplasty in a single centre. Designs and methods. Data was collected retrospectively. Comprehensive case reviews were done to collect demographic, intra-operative and post-operative data. Fractures were classified as per AO classification. The primary outcome was functional outcome and range of motion (ROM). The secondary outcomes were complications and patient satisfaction.
Objectives. Several studies have reported elevated blood cobalt (Co) and chromium (Cr) concentrations in patients with total knee replacements (TKRs). Up to 44% of tissue samples taken from patients with failed TKRs exhibit histological evidence of metal sensitivity/ALVAL. In simulated conditions, metal particles contribute approximately 12% of total wear debris in TKR. We carried out this investigation to determine the source and quantity of metal release in TKRs. Design and Methods. We analysed 225 explanted fixed-bearing TKRs (Attune, Genesis II, NexGen, PFC, and Vanguard) revised for any indication. These were analysed using peer-reviewed [coordinate measuring machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D profilometry (surface roughness-Ra) and light microscopy. Histological and blood metal ion concentration analyses were performed in a sub-sample of patients.
Introduction. Instability in ACL deficient knees can lead to medial compartment osteoarthritis. The risk of developing significant OA is 5x higher in knees with ACL deficiency. In associated Varus, there is quicker progression of the medial OA along with a varus thrust exerting strain on the ACL graft. The simultaneous valgus HTO and ACL reconstruction decompresses the medial tibiofemoral joint, corrects the mechanical-axis and reduces strain on the graft. Outcomes for this simultaneous procedure are still unclear in literature and we attempt evaluating its functional outcome. Methods. This Panel study was performed using data from 2019 to 2022 on 21 patients who had ACL insufficiency with Varus or medial OA and underwent a simultaneous Opening-wedge HTO with Arthroscopic ACL reconstruction. The mean follow-up was 2 years. The patients were evaluated with IKDC and Lysholm scores, Lachman test and ROM pre and post-operatively. The HKA was compared pre and post-operatively and the complications were evaluated. The progression of OA was evaluated with serial radiographs post-operatively.
Objectives. Sacroiliac joint dysfunction is a degenerative condition that can result in low back pain and is likely underdiagnosed. Diagnosis is made clinically with the patient experiencing pain in the sacroiliac joint region. Initial management is non-operative with pain management, physiotherapy, injections, and rhizolysis. If these fail then surgical management, by sacroiliac joint fusion, can be considered. The aim of this study was to review the outcomes of all patients who underwent sacroiliac joint fusion by a single surgeon in a large district general hospital between April 2018 and April 2023. Design and Methods. A retrospective review of all patients who underwent sacroiliac joint fusion between April 2018 and April 2023 was conducted. Data was collected from clinical letters, operative notes, and the British Spinal Registry. Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS) for back and leg pain were recorded as well as any post-operative complications.
Introduction & Aim. During TKR it is mandatory to achieve perfect soft tissue balance and component alignment. It is necessary to access all tight structures for proper releases. We aim to analyze the results of Trivector arthrotomy approach for TKRs. Methods. It is a retrospective study of 1050 cases between 2010-2020. All cases were performed by a single surgeon. Approach includes dividing distal 30% of vastus medialis along with medial retinaculum - 1cm medial to patella and patellar tendon distally up to Tibial tuberosity and raised as a single flap.
Objectives. Unicompartmental knee replacement (UKR) is a conservative option for degenerative disease, with mobile (Oxford UKR) and fixed bearing (Physica ZUK) the most commonly used devices. The primary reasons for revising UKRs include disease progression (36.9%), loosening (31.7%), and pain (7.5%). Loosening typically occurs due to osteolysis caused by wear particles from the polyethylene (PE) inserts. There is limited published literature which has quantified volumetric material loss from the PE inserts of cemented fixed-bearing UKRs. This study aimed to quantify bearing wear and backside deformation of these PE components. Design and Methods. At our national retrieval centre, we measured changes volumetric bearing wear and backside deformation of 31 explanted fixed-bearing Physica ZUK UKR PE inserts using a peer-reviewed methodology based on coordinate measuring machine analysis. These explants had been revised for any indication [Females (19) and Males (12)]. The location of the wear scars was identified and mapped. We compared the volumetric wear from the bearing surface with contemporary total knee replacement (TKR) inserts.
Objectives. To determine whether patients with scoliosis, treated with or without surgery, are at higher risk of needing caesarean section. To determine whether patients with scoliosis, treated with or without surgery, have increased intra-partum obstetric analgesic requirements. Design and Methods. Retrospective cohort study wherein obstetric outcomes were analysed in women with scoliosis in a tertiary teaching hospital. Women with scoliosis were identified using the high-risk obstetric anaesthesia register. Data was collected between May 2013 to April 2023.
Introduction. Video recording to teach and assess both technical and non-technical skills is well-established within medical education. Trainees’ clinical and practical competencies are evaluated using Procedure-Based Assessments (PBAs). However, there is limited research describing how these PBAs truly reflect trainee performance. We sought to:. 1). assess the duration between the procedure and PBA completion. 2). assess the perceived viability of supplementing assessments using intra-operative camera footage and. 3). clarify medico-legal considerations for the use of cameras in theatre. Method. We undertook a survey of Orthopaedic trainees in the East of England Deanery, United Kingdom. A six-item questionnaire was designed and provided to trainees (paper and online) to assess the time between procedure and filling in PBA forms, level of consultant input, time to PBA sign-off and trainees’ views on current PBA methods, operative video recording and retrospective access to clinical footage.
Aims. Mesenchymal stem cells (MSCs) are usually cultured in a normoxic atmosphere (21%) in vitro, while the oxygen concentrations in human tissues and organs are 1% to 10% when the cells are transplanted in vivo. However, the impact of hypoxia on MSCs has not been deeply studied, especially its translational application. Methods. In the present study, we investigated the characterizations of human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) in hypoxic (1%) and normoxic (21%) atmospheres with a long-term culture from primary to 30 generations, respectively. The comparison between both atmospheres systematically analyzed the biological functions of MSCs, mainly including stemness maintenance, immune regulation, and resistance to chondrocyte apoptosis, and studied their joint function and anti-inflammatory effects in osteoarthritis (OA) rats constructed by collagenase II.
Objectives. Minimally invasive surgery (MIS) has gained popularity for hallux valgus, compared to the traditional scarf osteotomy (OS). Though evidence suggests similar clinical outcomes, there is paucity of randomised controlled studies. This study aimed to assess the feasibility of conducting a randomised controlled trial comparing the patient recorded and clinical outcomes for the surgical management of Hallux Valgus between OS and MIS Chevron Akin (MICA). Methods. Patients suitable for surgical correction were invited to participate. Post-op rehabilitation was standardised for both groups. Patients completed a validated questionnaire (Manchester Oxford Foot questionnaire and EQ-5D-5L) pre-operatively and post-operatively at 6 months and 1 year. Radiological parameters and range of motion were measured pre-and post-operatively.
Objective. Neurological injuries are most common complication, which has refrained many surgeons from opting elbow arthroscopy for indicated surgeries. The objective of this study was to evaluate the safety of anterolateral (AL) and posterolateral (PL) portals and chances of injury to the radial nerve and posterior interosseous nerve around the elbow joint during elbow arthroscopy. Material & Methods. A cadaveric study was conducted on 16 non dissected cadavers (32 elbow specimens) between the period of January 2021 to June 2022. Four portals were established using 4 mm Steinmann pins which are Proximal AL Portal, Mid-AL Portal, Distal AL Portal and PL Portal. The measurements of each portal were taken for each nerve and compared with each other.
Introduction & Aim. The use of All-Poly Tibia has been in practice since the early 1970's. Recently due to the reports on wear and osteolysis in other articulations, this component has generated significant interest. In the current study we aim to report early medium-term results of All-poly Tibial components in elderly (>70 years) patients. Method. Study of 455 cases done between 2005-2020. All the cases were performed by a single surgeon. All-Poly Tibial component implantations were performed using Standard mechanical jigs and the same posterior-stabilized implant was used for all cases.
Objectives. We identified an unusual pattern of backside deformation on polyethylene (PE) inserts of contemporary total knee replacements (TKRs). The PE backside's margins were inferiorly deformed in TKRs with NexGen central-locking trays. This backside deformation was significantly associated with tray debonding. Furthermore, recent studies have shown high rate of tray debonding in PS NexGen TKRs. Subsequently, a field safety notice was issued regarding the performance of this particular device combination and the Option tray has been withdrawn from use. Therefore, we hypothesised that the backside deformation of PS inserts may be greater than that of CR inserts. Design and Methods. At our national implant retrieval centre, we used peer-reviewed techniques to analyse changes in the bearing wear rate and backside surface deformation of NexGen PE inserts using coordinate measuring machines [N=84 (CR-43 and PS-41) TKRs with non-augmented-trays]. Multiple regression was used to determine which variable had the greatest influence on backside deformation. The amount of cement cover on trays was quantified as a %of the total surface using Image-J software.