Introduction. Low back pain (LBP) is a worldwide leading cause of disability. This preclinical study evaluated the safety of a combined advanced therapy medicinal product developed during the European iPSpine project (#825925) consisting of mesendoderm progenitor cells (MEPC), derived from human induced pluripotent stem cells, in combination with a synthetic poly(N-isopropylacrylamide) hydrogel (NPgel) in an ovine intervertebral disc degeneration (IDD) model. Method. IDD was induced through nucleotomy in 4 adult sheep, 5 lumbar discs each (n=20). After 5 weeks, 3 alternating discs were treated with NPgel (n=6) or NPgel+MEPC (n=6). Before sacrifice, animals were subjected to: MRI of lumbar spines (disc height and Pfirmann grading); blood sampling (hematological, biochemical, metabolic and lymphocyte/monocytes immunological). After 3 months the sheep were sacrificed. The spines were processed for: macroscopic morphology (Thompson grading), microscopic morphology (Histological grading), and glycosaminoglycan content (GAG, DMMB Assay). Furthermore, at sacrifice biodistribution of human MEPC was assessed by Alu-sequences quantification (qPCR) from three tissue samples of heart, liver, spleen, brain, lungs, and kidneys, and PBMCs collected to assess activation of systemic immune cells. To each evaluation, appropriate statistical analysis was applied. Result. Flow cytometry showed no induction of systemic activation of T cells or monocytes. Alu quantification did not give detection of any cells in any organ. Disc height index was slightly increased in discs treated with NPgel+MEPC. Pfirmann'
Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system. A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected.Aims
Methods
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented
We conducted a systematic review and meta-analysis to compare the mortality, morbidity, and functional outcomes of cemented versus uncemented hemiarthroplasty in the treatment of intracapsular hip fractures, analyzing contemporary and non-contemporary implants separately. PubMed, Medline, EMBASE, CINAHL, and Cochrane Library were searched to 2 February 2020 for randomized controlled trials (RCTs) comparing the primary outcome, mortality, and secondary outcomes of function, quality of life, reoperation, postoperative complications, perioperative outcomes, pain, and length of hospital stay. Relative risks (RRs) and mean differences (with 95% confidence intervals (CIs)) were used as summary association measures.Aims
Methods
Interleukin 18 (IL-18) is a regulatory cytokine that degrades the disc matrix. Bone morphogenetic protein-2 (BMP-2) stimulates synthesis of the disc extracellular matrix. However, the combined effects of BMP-2 and IL-18 on human intervertebral disc degeneration have not previously been reported. The aim of this study was to investigate the effects of the anabolic cytokine BMP-2 and the catabolic cytokine IL-18 on human nucleus pulposus (NP) and annulus fibrosus (AF) cells and, therefore, to identify potential therapeutic and clinical benefits of recombinant human (rh)BMP-2 in intervertebral disc degeneration. Levels of IL-18 were measured in the blood of patients with intervertebral disc degenerative disease and in control patients. Human NP and AF cells were cultured in a NP cell medium and treated with IL-18 or IL-18 plus BMP-2. mRNA levels of target genes were measured by real-time polymerase chain reaction, and protein levels of aggrecan, type II collagen, SOX6, and matrix metalloproteinase 13 (MMP13) were assessed by western blot analysis.Objectives
Methods
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
We performed a case–control study to compare
the rates of further surgery, revision and complications, operating time
and survival in patients who were treated with either an uncemented
hydroxyapatite-coated Corail bipolar femoral stem or a cemented
Exeter stem for a displaced intracapsular fracture of the hip. The
mean age of the patients in the uncemented group was 82.5 years
(53 to 97) and in the cemented group was 82.7 years (51 to 99) We used
propensity score matching, adjusting for age, gender and the presence
or absence of dementia and comorbidities, to produce a matched cohort
receiving an Exeter stem (n = 69) with which to compare the outcome of
patients receiving a Corail stem (n = 69). The Corail had a significantly
lower all-cause rate of further surgery (p = 0.016; odds ratio (OR)
0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further
surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating
time was significantly less for the Corail group than for the cemented Exeter
group (59 min [12 to 136] Cite this article:
Following the recommendation of NICE guidelines (CG124) we have recently started using cemented smooth tapered stem hemiarthroplasty as our standard management of intra-capsular neck of femur fractures. Prior to publication of the above guidelines the standard implant utilised was Thompson Hemiarthroplasty prosthesis. The cost implications of this change have not been fully appreciated and the benefit of these changes in ASA grade 3–4 patients has not previously been analysed. We identified a cohort of 89 patients admitted with displaced intra-capsular neck of femur fracture with an ASA grade 3–4. These underwent hip hemiarthroplaties at our centre over a period of 12 months (before and after guideline implementation). Data regarding in-hospital mortality, dislocation, reoperation and place of discharge were retrospectively collected and analysed. Our cohort included 46 patients who underwent a Thompsons Hemiarthroplasty, 30 patients who had a cemented smooth tapered stem hemiarthroplasty and 13 patients who had an Austin-moore Hemiarthroplasty. In-patient mortality rates were highest in the Austin-moore group, followed by the Thompsons group compared to none in the smooth tapered stem group. However, this was not statistically significant. One patient in the Thompsons group and one patient in the smooth tapered group had multiple dislocations and re-operations, compared with none in the Austin-moore group. In terms of percentage of patients who were discharged home from hospital the smooth tapered stem group had a percentage that was more than twice that of the
We report the results of six trauma and orthopaedic
projects to Kenya in the last three years. The aims are to deliver both
a trauma service and teaching within two hospitals; one a district
hospital near Mount Kenya in Nanyuki, the other the largest public
hospital in Kenya in Mombasa. The Kenya Orthopaedic Project team
consists of a wide range of multidisciplinary professionals that
allows the experience to be shared across those specialties. A follow-up
clinic is held three months after each mission to review the patients.
To our knowledge there are no reported outcomes in the literature
for similar projects. A total of 211 operations have been performed and 400 patients
seen during the projects. Most cases were fractures of the lower
limb; we have been able to follow up 163 patients (77%) who underwent
surgical treatment. We reflect on the results so far and discuss
potential improvements for future missions.
Introduction. Following National patient safety alert on cement use in hip fracture surgery, we investigated the incidence and pattern of 72 hours peri-operative mortality after hip fracture surgery in a District General Hospital. Methods. We reviewed all patients who had hip fracture surgery between 2005-April, 2010. We recorded demographic variables, type of fracture, implant used, medical co-morbidity, seniority of operating surgeon and anaesthetist, peri-operative haemodynamic status, time and cause of death. Results. Over a 64 month period 15 cases were identified. Peri-operative death (PAD) was 1% (15/1402). 4/15 patients died intra-operatively. PAD was highest following Exeter Trauma Stem (ETS) implantation (5/85, 6%) and nil following Bipolar arthroplasty, Austin-Moore arthroplasty (AMA) or Cannulated screw fixation. PAD following total hip arthroplasty was 4% (1/25),
Current evidence suggests that we should be moving away from
Current evidence suggests that we should be moving away from
The cement in cement technique for revision total hip arthroplasty (THA) has shown good results in selected cases. However, results of its use in the revision of hemiarthroplasty to THA has not been previously reported. Between May 1994 and May 2007 28 (20
The carpometacarpal joint of the thumb is one of the most common locations of degenerative arthritis. Surgical options include trapezio-metacarpal fusion, replacement or resection arthroplasty with or without interposition. We report the medium term results of a Modified
The cement in cement technique for revision total hip arthroplasty (THA) has shown good results in selected cases. However results of its use in the revision of hemiarthroplasty to THA has not been previously reported. Between May 1994 and May 2007 28 (20
In 2006 the standard prosthesis for hip hemiarthroplasty in our unit was changed from the traditional Thompson prosthesis used for over 20 years to the monobloc Exeter Trauma Stem (ETS). The principle anticipated advantages were ease of stem implantation, improvement of orientation positioning and a consistency with modern proven femoral THR stem design. All patients selected for hemiarthroplasty replacement for a displaced subcapital fracture of the hip were eligible for inclusion. Failed previous surgical cases were excluded. The last 100
Between 1987 and 2006 we performed a modified
Background:Displaced sub-capital fractures of the femur are traditionally treated by hip arthroplasty (hemi or total joint replacement). Total hip arthroplasty (THA) was formerly disfavored due to presumed higher peri-operative complications, higher costs and higher incidence of dis-location. Lately, this procedure regained acceptance as a suitable solution for active elderly patients. The use of monopolar hemi-arthroplasty implants (Austin-Moore’
We have performed a prospective review of 590 consecutive patients treated for a displaced intracapsular femoral neck fracture with a Thompson hemiarthroplasty. 113 patients had the prosthesis cemented, 477 had no cement. The outcome at 12 months was obtained for every patient still alive as regards to pain, mobility, re-operation rate and residential status. There was no significant difference between the 2 groups as regards pain (p = 0.482), decrease in mobility or re-operation rate (p = 0.168). The main determination of poor outcome was increasing age at time of injury and whether the patient was already in institutional care at the time of the injury. The use of cement had no bearing on outcome. This study is of clinical interest because patients who have undergone uncemented hemiarthroplasty have been shown to have similar out come to cemented hemiarthroplasty in terms of function. In addition possible but preventable complications associated with cementing can be minimized. We now believe there is no primary indication to cement the Thompsons hemiarthroplasty in this group of patients. There have been smaller studies looking at this, but we believe this to be the largest and most comprehensive to date.