Advertisement for orthosearch.org.uk
Results 1 - 20 of 7373
Results per page:
Bone & Joint Open
Vol. 5, Issue 12 | Pages 1120 - 1122
20 Dec 2024
Gill RHS Haddad FS

Cite this article: Bone Jt Open 2024;5(12):1120–1122.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1123 - 1129
20 Dec 2024
Manara JR Nixon M Tippett B Pretty W Collopy D Clark GW

Aims. Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized TKA alignment techniques. Functional alignment (FA) is a novel technique for performing a TKA and shares many principles with UKA. Our aim was to compare outcomes from a case-matched series of robotic-assisted UKAs and robotic-assisted TKAs performed using FA. Methods. From a prospectively collected database between April 2015 and December 2019, patients who underwent a robotic-assisted medial UKA (RA-UKA) were case-matched with patients who had undergone a FA robotic-assisted TKA (RA-TKA) during the same time period. Patients were matched for preoperative BMI, sex, age, and Forgotten Joint Score (FJS). A total of 101 matched pairs were eligible for final review. Postoperatively the groups were then compared for differences in patient-reported outcome measures (PROMs), range of motion (ROM), ability to ascend and descend stairs, and ability to kneel. Results. Both groups had significant improvements in mean FJS (65.1 points in the TKA group and 65.3 points in the UKA group) and mean Oxford Knee Score (OKS) (20 points in the TKA group and 18.2 in the UKA group) two years following surgery. The UKA group had superior outcomes at three months in the OKS and at one year in ROM (5°), ability to kneel (0.5 points on OKS question), and ascend (1.3 points on OKS question) and descend stairs (0.8 points on OKS question), but these were not greater than the minimal clinically important difference. There were no differences seen in FJS or OKS at one year postoperatively. There were no statistically significant differences between the groups at 24 months in all the variables assessed. Conclusion. FA-RATKA and RA-UKA are both successful treatments for medial compartmental knee arthritis in this study. The UKA group showed a quicker recovery, but this study demonstrated equivalent two-year outcomes in all outcomes measured including stair ascent and descent, and kneeling. Cite this article: Bone Jt Open 2024;5(12):1123–1129


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1108 - 1113
18 Dec 2024
Prakash R Nasser A Sharma A Eastwood D Reed M Agrawal Y

Aims. Arthroplasty has been shown to generate the most waste among all orthopaedic subspecialties, and it is estimated that hip and knee arthroplasty generate in excess of three million kg of waste annually in the UK. Infectious waste generates up to ten times more CO2 compared with recycled waste, and previous studies have shown that over 90% of waste in the infectious stream is misallocated. We assessed the effect of real-time waste segregation by an unscrubbed team member on waste generation in knee and hip arthroplasty cases, and compared this with a simple educational intervention during the ‘team brief’ at the start of the operating list across two sites. Methods. Waste was categorized into five categories: infectious, general, recycling, sharps, and linens. Each category was weighed at the end of each case using a digital weighing scale. At Site A (a tertiary orthopaedic hospital), pre-intervention data were collected for 16 total knee arthroplasy (TKA) and 15 total hip arthroplasty (THA) cases. Subsequently, for ten TKA and ten THA cases, an unscrubbed team member actively segregated waste in real-time into the correct streams. At Site B (a district general hospital), both pre- and post-intervention groups included ten TKA and ten THA cases. The intervention included reminding staff during the ‘team brief’ to segregate waste correctly. Results. Active real-time waste segregation reduced infectious waste by a mean of 2.51 kg (95% CI 1.492 to 3.542) in TKA, and 1.83 kg in THA cases (p = 0.004). Educational intervention reduced infectious waste by a mean of 3.52 kg in TKA and 2.09 kg in THA cases (p = 0.026). Total waste was significantly reduced in both groups post-intervention for TKA cases. Conclusion. Simple educational measures alone can significantly reduce the amount of infectious waste. Extrapolated nationally, our results would yield a reduction of approximately 315,004 kg to 594,577 kg of CO2 annually, which equates to 70 to 132 gasoline-powered passenger vehicles driven for a year. Cite this article: Bone Jt Open 2024;5(12):1119–1124


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 12 - 12
12 Dec 2024
Langton D Bhalekar R Wells S Nargol M Natu S Nargol A Waller S Pabbruwe M Sidaginamale R
Full Access

Objectives. Several studies have reported elevated blood cobalt (Co) and chromium (Cr) concentrations in patients with total knee replacements (TKRs). Up to 44% of tissue samples taken from patients with failed TKRs exhibit histological evidence of metal sensitivity/ALVAL. In simulated conditions, metal particles contribute approximately 12% of total wear debris in TKR. We carried out this investigation to determine the source and quantity of metal release in TKRs. Design and Methods. We analysed 225 explanted fixed-bearing TKRs (Attune, Genesis II, NexGen, PFC, and Vanguard) revised for any indication. These were analysed using peer-reviewed [coordinate measuring machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D profilometry (surface roughness-Ra) and light microscopy. Histological and blood metal ion concentration analyses were performed in a sub-sample of patients. Results. The median (IQR) PE wear rate was 14 (6 to 20) mm. 3. /year. Microscopic examination of the superior surface of trays exhibited pitting on 132 (59%) of trays. There was a statistically significant (p<0.05) increase in Rvk on the pitted area of trays for each design, indicating material removal from the pits compared to the unpitted area. The inferior surface of 116(51%) of trays displayed polishing, indicative of abrasive wear. The median(range) Co and Cr concentrations were 2.5µg/l (0.2–69.4) and 1.7µg/l (0.5-12.5) respectively in 40 patients. Of the tissue samples examined in 30 patients, 6 had at least “mild”-ALVAL infiltrate. All corresponding “ALVAL” explants were found to be pitted and/or show evidence of loosening of the tray. Conclusion. This study provides further evidence that CoCr release in TKR appears to be an under-appreciated cause of adverse clinical outcomes. The generation of metal particles was predominantly from the metal tray, which may explain elevated metal ions after TKRs, despite no direct metal-on-metal contact


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 16 - 16
12 Dec 2024
Shah D Shah A
Full Access

Introduction & Aim. During TKR it is mandatory to achieve perfect soft tissue balance and component alignment. It is necessary to access all tight structures for proper releases. We aim to analyze the results of Trivector arthrotomy approach for TKRs. Methods. It is a retrospective study of 1050 cases between 2010-2020. All cases were performed by a single surgeon. Approach includes dividing distal 30% of vastus medialis along with medial retinaculum - 1cm medial to patella and patellar tendon distally up to Tibial tuberosity and raised as a single flap. Results. 656 cases Varus + FFD, 305 Varus, 60 Valgus, 24 hyperextension deformity & 5 neutral alignment cases were included. Results showed 87% patients at postop day-1 and 96% by day-4 regained ability to perform unassisted SLR. 4% had 5-to-10-degree quadriceps lag at discharge & recovered to neutral by 4 weeks. The surgical field was adequate in all cases. KSS score improved from Pre op of 56 (38-71) to a post op of 89 (84-95). All patients by day 10 were walking unaided or with a single cane in case of Bilateral TKRs. Medial parapatellar arthrotomy divides the quadriceps tendon. The alteration in various vectors of Quadriceps can change the balance and laterally mal-track the patella. Incidence of Lateral release is higher with this. Mid and subvastus approaches are non-extensile and have poor visibility during surgery increasing risk of malalignment. Trivector arthrotomy is extensile and retains 70% strength of vastus medialis. At closure, the quads mechanism is perfectly aligned, reducing the incidence of lateral mal-tracking and lateral release. Conclusion. The extensile nature of the approach and minimal disruption of the quadriceps mechanism encourages us to use this approach for all cases. It is a true “Gateway.”


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 3 - 3
12 Dec 2024
Bhalekar R Wells S Nargol M Nargol A Waller S Wildberg L Sidaginamale R Langton DJ
Full Access

Objectives. Unicompartmental knee replacement (UKR) is a conservative option for degenerative disease, with mobile (Oxford UKR) and fixed bearing (Physica ZUK) the most commonly used devices. The primary reasons for revising UKRs include disease progression (36.9%), loosening (31.7%), and pain (7.5%). Loosening typically occurs due to osteolysis caused by wear particles from the polyethylene (PE) inserts. There is limited published literature which has quantified volumetric material loss from the PE inserts of cemented fixed-bearing UKRs. This study aimed to quantify bearing wear and backside deformation of these PE components. Design and Methods. At our national retrieval centre, we measured changes volumetric bearing wear and backside deformation of 31 explanted fixed-bearing Physica ZUK UKR PE inserts using a peer-reviewed methodology based on coordinate measuring machine analysis. These explants had been revised for any indication [Females (19) and Males (12)]. The location of the wear scars was identified and mapped. We compared the volumetric wear from the bearing surface with contemporary total knee replacement (TKR) inserts. Results. The median (IQR) total volumetric wear of the UKR PEs [96(50-152) mm. 3. ] was significantly higher (p<0.001) than contemporary TKR PEs [40 (24-83) mm. 3. ]. The median (IQR) total volumetric wear of the PEs in males [148(122-200) mm. 3. ] was significantly higher(p=0.016) than in females [56(61-119) mm. 3. ]. The wear scars were situated in the anterior third in 61% of cases, with 26% located posteriorly. Examination of the PE backside surfaces exhibited damage in the area directly inferior to the bearing surface wear scar in the majority of cases. Conclusion. In conclusion, this study highlights significant PE wear of Physica ZUK UKR inserts, with higher wear rates compared to contemporary TKR inserts, particularly in males


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 5 - 5
12 Dec 2024
Shah D Shah A
Full Access

Introduction & Aim. The use of All-Poly Tibia has been in practice since the early 1970's. Recently due to the reports on wear and osteolysis in other articulations, this component has generated significant interest. In the current study we aim to report early medium-term results of All-poly Tibial components in elderly (>70 years) patients. Method. Study of 455 cases done between 2005-2020. All the cases were performed by a single surgeon. All-Poly Tibial component implantations were performed using Standard mechanical jigs and the same posterior-stabilized implant was used for all cases. Results. 20 cases were lost to follow-up. 25 patients died due to natural causes. Mean age at index surgery was 74 years (70 - 91 years). Preop KSS average was 47 (31- 62). Post operative at the last follow up was 87 (71- 93). Of the 410 cases there were 8 revisions, 6 for deep sepsis and 2 for periprosthetic fractures. There were no revisions for aseptic loosening or osteolysis. All cases are performing well functionally and clinically. 18 cases had a non-progressive radiolucent line beneath the Tibial component. The combination of perfect alignment and soft tissue balance creates an environment for a successful TKR. The choice of the All-Poly Tibial component for functionally low demand age group patients reduces the chances of premature wear and osteolysis. In elderly patients the implant should outlive the patient. Here it is observed that at 5-7 years aseptic loosening and subsequent revision chances are low. The all-poly Tibial component is significantly cheaper as compared to its metal back counterpart. Conclusion. An excellent clinical result in our hands for this group of patients supports the continued use of this implant strongly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 13 - 13
12 Dec 2024
Langton D Bhalekar R Wells S Nargol M Natu S Nargol A Waller S Pabbruwe M Sidaginamale R
Full Access

Objectives. We identified an unusual pattern of backside deformation on polyethylene (PE) inserts of contemporary total knee replacements (TKRs). The PE backside's margins were inferiorly deformed in TKRs with NexGen central-locking trays. This backside deformation was significantly associated with tray debonding. Furthermore, recent studies have shown high rate of tray debonding in PS NexGen TKRs. Subsequently, a field safety notice was issued regarding the performance of this particular device combination and the Option tray has been withdrawn from use. Therefore, we hypothesised that the backside deformation of PS inserts may be greater than that of CR inserts. Design and Methods. At our national implant retrieval centre, we used peer-reviewed techniques to analyse changes in the bearing wear rate and backside surface deformation of NexGen PE inserts using coordinate measuring machines [N=84 (CR-43 and PS-41) TKRs with non-augmented-trays]. Multiple regression was used to determine which variable had the greatest influence on backside deformation. The amount of cement cover on trays was quantified as a %of the total surface using Image-J software. Results. The median (IQR) bearing wear rate of the PS PEs [14(8-22) mm. 3. /year] was not significantly different(p=0.154) to that of the CR PEs [18(8-27)mm. 3. /year]. The median (IQR) backside deformation of the PS inserts [294(239-361) µm] was significantly greater (p<0.001) than that of the CR inserts [212(158-258)µm]. Multiple regression modelling showed that duration in-vivo (p=0.037), central-clearance between insert and tray (p<0.001) and constraint (p=0.003) were significantly associated with PE backside-deformation. 38(93%) PS and 31(72%) of CR trays exhibited ≤10% of cement cover. Non-contacting profilometry and microscopy revealed marked pitting and abrasive changes to the superior surface of the tray. Conclusion. This explant study showed the PE backside deformation was significantly higher in PS than in CR inserts and this may be one explanation for the unsatisfactory clinical performance reported with this device combination


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 17 - 17
12 Dec 2024
Ponugoti N Mccann E Ramappa M
Full Access

Background. The rise in the adoption of outpatient arthroplasty has been attributed to its cost-effectiveness, although safety concerns persist. In this meta-analysis, we compare inpatient and outpatient joint arthroplasty with a primary focus on readmission and complication rates, using exclusively high-quality prospective data. Cost-effectiveness was used as a secondary outcome measure. Methods. A literature search was performed in Medline, Embase and Cochrane Library from inception to October 2023. A predefined strategy was used to conduct a systematic review and meta-analysis. Twelve studies were deemed eligible for inclusion. These were critically appraised using RoB analysis and MINORS criteria. Overall readmission rate, readmission rate for THA, readmission rate for TKA, complication rate and cost-analysis were selected as outcomes of interest. Forest plots were extracted using RevMan 5.3.5 software. Results. The twelve studies included 2470 patients, of which 1052 were outpatients and 1418 inpatient subjects undergoing arthroplasty. Forest plot analysis showed no significant difference in safety outcomes (readmission and complication rates). However, there were significantly lower costs in the outpatient group compared to the inpatient group. The results of the analysis were; overall readmission rate (Odds ratio 0.66; P= 0.29; I. 2. =18%), readmission rate in THA (odds ratio 0.62; P=0.10; I. 2. =51%), readmission rate in TKA (odds ratio 0.67; P=0.56; I. 2. =0%), overall complication rate (odds ratio 0.77; P=0.12; I. 2. =38%) and cost analysis (RR −2.88; P<0.00001; I. 2. = 93%). Conclusions. This meta-analysis demonstrates that outpatient total joint arthroplasty (TJA) is a safe option, when compared to inpatient surgery. However, it is clear that further prospective studies and long-term randomized clinical data are necessary for a more comprehensive understanding


Aims. Functional alignment (FA) in total knee arthroplasty (TKA) aims to achieve balanced gaps by adjusting implant positioning while minimizing changes to constitutional joint line obliquity (JLO). Although FA uses kinematic alignment (KA) as a starting point, the final implant positions can vary significantly between these two approaches. This study used the Coronal Plane Alignment of the Knee (CPAK) classification to compare differences between KA and final FA positions. Methods. A retrospective analysis compared pre-resection and post-implantation alignments in 2,116 robotic-assisted FA TKAs. The lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were measured to determine the arithmetic hip-knee-ankle angle (aHKA = MPTA – LDFA), JLO (JLO = MPTA + LDFA), and CPAK type. The primary outcome was the proportion of knees that varied ≤ 2° for aHKA and ≤ 3° for JLO from their KA to FA positions, and direction and magnitude of those changes per CPAK phenotype. Secondary outcomes included proportion of knees that maintained their CPAK phenotype, and differences between sexes. Results. Overall, 71.6% had an aHKA change ≤ 2°, and 87.0% a JLO change ≤ 3°. Mean aHKA changed from -1.1° (SD 2.8°) in KA to -1.9° (SD 2.3°) in FA (mean difference (MD) -0.83 (SD 2.0); p < 0.001). Mean JLO changed from 173.9° (SD 3.0°) in KA to 174.2° (SD 2.6°) in FA (MD 0.38 (SD 2.3); p < 0.001). CPAK type was maintained in 58.1% of knees, with the proportion highest for Types I (73.9%), II (61.1%), and IV (51.2%). In valgus knees, 67.5% of Type III and 71.7% of Type VI were shifted to neutral phenotypes. There was minimal change to constitutional JLO across all CPAK types (MDs -2.0° to 1.2°). Conclusion. Functional alignment may alter CPAK type, but does not significantly change JLO. A kinematic starting point minimizes changes to native anatomy, while final position with FA provides an optimally balanced TKA. Cite this article: Bone Jt Open 2024;5(12):1081–1091


Bone & Joint Research
Vol. 13, Issue 12 | Pages 741 - 749
6 Dec 2024
Blichfeldt-Eckhardt MR Varnum C Lauridsen JT Rasmussen LE Mortensen WCP Jensen HI Vaegter HB Lambertsen KL

Aims

Better prediction of outcome after total hip arthroplasty (THA) is warranted. Systemic inflammation and central neuroinflammation are possibly involved in progression of osteoarthritis and pain. We explored whether inflammatory biomarkers in blood and cerebrospinal fluid (CSF) were associated with clinical outcome, and baseline pain or disability, 12 months after THA.

Methods

A total of 50 patients from the Danish Pain Research Biobank (DANPAIN-Biobank) between January and June 2018 were included. Postoperative outcome was assessed as change in Oxford Hip Score (OHS) from baseline to 12 months after THA, pain was assessed on a numerical rating scale, and disability using the Pain Disability Index. Multiple regression models for each clinical outcome were included for biomarkers in blood and CSF, respectively, including age, sex, BMI, and Kellgren-Lawrence score.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1067 - 1071
2 Dec 2024
Salzmann M Kropp E Prill R Ramadanov N Adriani M Becker R

Aims. The transepicondylar axis is a well-established reference for the determination of femoral component rotation in total knee arthroplasty (TKA). However, when severe bone loss is present in the femoral condyles, rotational alignment can be more complicated. There is a lack of validated landmarks in the supracondylar region of the distal femur. Therefore, the aim of this study was to analyze the correlation between the surgical transepicondylar axis (sTEA) and the suggested dorsal cortex line (DCL) in the coronal plane and the inter- and intraobserver reliability of its CT scan measurement. Methods. A total of 75 randomly selected CT scans were measured by three experienced surgeons independently. The DCL was defined in the coronal plane as a tangent to the dorsal femoral cortex located 75 mm above the joint line in the frontal plane. The difference between sTEA and DCL was calculated. Descriptive statistics and angulation correlations were generated for the sTEA and DCL, as well as for the distribution of measurement error for intra- and inter-rater reliability. Results. The external rotation of the DCL to the sTEA was a mean of 9.47° (SD 3.06°), and a median of 9.2° (IQR 7.45° to 11.60°), with a minimum value of 1.7° and maximum of 16.3°. The measurements of the DCL demonstrated very good to excellent test-retest and inter-rater reliability coefficients (intraclass correlation coefficient 0.80 to 0.99). Conclusion. This study reveals a correlation between the sTEA and the DCL. Overall, 10° of external rotation of the dorsal femoral cortical bone to the sTEA may serve as a reliable landmark for initial position of the femoral component. Surgeons should be aware that there are outliers in this study in up to 17% of the measurements, which potentially could result in deviations of femoral component rotation. Cite this article: Bone Jt Open 2024;5(12):1067–1071


Bone & Joint 360
Vol. 13, Issue 6 | Pages 19 - 22
1 Dec 2024

The December 2024 Knee Roundup. 360. looks at: Unicompartmental knee arthroplasty and total knee arthroplasty in the same patient?; Lateral unicompartmental knee arthroplasty: is it a good option?; The fate of the unresurfaced patellae in contemporary total knee arthroplasty: early- to mid-term results; Tibial baseplate migration is not associated with change in PROMs and clinical scores after total knee arthroplasty; Unexpected positive intraoperative cultures in aseptic revision knee arthroplasty: what effect does this have?; Kinematic or mechanical alignment in total knee arthroplasty surgery?; Revision total knee arthroplasty achieves minimal clinically important difference faster than primary total knee arthroplasty; Outcomes after successful DAIR for periprosthetic joint infection in total knee arthroplasty


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1049 - 1066
1 Dec 2024
Lister J James S Sharma HK Hewitt C Fulbright H Leggett H McDaid C

Aims

Lower limb reconstruction (LLR) has a profound impact on patients, affecting multiple areas of their lives. Many patient-reported outcome measures (PROMs) are employed to assess these impacts; however, there are concerns that they do not adequately capture all outcomes important to patients, and may lack content validity in this context. This review explored whether PROMs used with adults requiring, undergoing, or after undergoing LLR exhibited content validity and adequately captured outcomes considered relevant and important to patients.

Methods

A total of 37 PROMs were identified. Systematic searches were performed to retrieve content validity studies in the adult LLR population, and hand-searches used to find PROM development studies. Content validity assessments for each measure were performed following Consensus-based Standards for the selection of health measurement Instruments (COSMIN) guidelines. A mapping exercise compared all PROMs to a conceptual framework previously developed by the study team (‘the PROLLIT framework’) to explore whether each PROM covered important and relevant concepts.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 45 - 47
1 Dec 2024

The December 2024 Research Roundup360 looks at: Skeletal muscle composition, power, and mitochondrial energetics in older men and women with knee osteoarthritis; Machine-learning models to predict osteonecrosis in patients with femoral neck fractures undergoing internal fixation; Aetiology of patient dissatisfaction following primary total knee arthroplasty in the era of robotic-assisted technology; Efficacy and safety of commonly used thromboprophylaxis agents following hip and knee arthroplasty; The COVID-19 effect continues; Nickel allergy in knee arthroplasty: does self-reported sensitivity affect outcomes?; Tranexamic acid use and joint infection risk in total hip and knee arthroplasty.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1416 - 1425
1 Dec 2024
Stroobant L Jacobs E Arnout N Van Onsem S Tampere T Burssens A Witvrouw E Victor J

Aims

Approximately 10% to 20% of knee arthroplasty patients are not satisfied with the result, while a clear indication for revision surgery might not be present. Therapeutic options for these patients, who often lack adequate quadriceps strength, are limited. Therefore, the primary aim of this study was to evaluate the clinical effect of a novel rehabilitation protocol that combines low-load resistance training (LL-RT) with blood flow restriction (BFR).

Methods

Between May 2022 and March 2024, we enrolled 45 dissatisfied knee arthroplasty patients who lacked any clear indication for revision to this prospective cohort study. All patients were at least six months post-surgery and had undergone conventional physiotherapy previously. The patients participated in a supervised LL-RT combined with BFR in 18 sessions. Primary assessments included the following patient-reported outcome measures (PROMs): Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Society Score: satisfaction (KSSs); the EuroQol five-dimension five-level questionnaire (EQ-5D-5L); and the pain catastrophizing scale (PCS). Functionality was assessed using the six-minute walk Test (6MWT) and the 30-second chair stand test (30CST). Follow-up timepoints were at baseline, six weeks, three months, and six months after the start.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 22 - 23
1 Dec 2024

The December 2024 Arthroplasty Roundup360 looks at: Aspirin for hip and knee arthroplasty?; VTE prophylaxis; VTE prophylaxis part II.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1408 - 1415
1 Dec 2024
Wall L Bunzli S Nelson E Hawke LJ Genie M Hinwood M Lang D Dowsey MM Clarke P Choong PF Balogh ZJ Lohmander LS Paolucci F

Aims. Surgeon and patient reluctance to participate are potential significant barriers to conducting placebo-controlled trials of orthopaedic surgery. Understanding the preferences of orthopaedic surgeons and patients regarding the design of randomized placebo-controlled trials (RCT-Ps) of knee procedures can help to identify what RCT-P features will lead to the greatest participation. This information could inform future trial designs and feasibility assessments. Methods. This study used two discrete choice experiments (DCEs) to determine which features of RCT-Ps of knee procedures influence surgeon and patient participation. A mixed-methods approach informed the DCE development. The DCEs were analyzed with a baseline category multinomial logit model. Results. The proportion of respondents (surgeons n = 103; patients n = 140) who would not participate in any of the DCE choice sets (surgeons = 31%; patients = 40%), and the proportion who would participate in all (surgeons = 18%; patients = 30%), indicated strong views regarding the conduct of RCT-Ps. There were three main findings: for both surgeons and patients, studies which involved an arthroscopic procedure were more likely to result in participation than those with a total knee arthroplasty; as the age (for patients) and years of experience (for surgeons) increased, the overall likelihood of participation decreased; and, for surgeons, offering authorship and input into the RCT-P design was preferred for less experienced surgeons, while only completing the procedure was preferred by more experienced surgeons. Conclusion. Patients and surgeons have strong views regarding participation in RCT-Ps. However, understanding their preferences can inform future trial designs and feasibility assessments with regard to recruitment rates. Cite this article: Bone Joint J 2024;106-B(12):1408–1415


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1426 - 1430
1 Dec 2024
Warne CN Ryan S Yu E Osmon DR Berry DJ Abdel MP

Aims

Cutibacterium acnes (C. acnes; previously known as Propionibacterium acnes or P. acnes) periprosthetic hip and knee infections are under-reported. While culture contamination with C. acnes occurs, true infections are important to recognize and treat. We sought to describe the demographics and treatment outcomes of patients with C. acnes periprosthetic joint infections (PJIs) of the hip and knee.

Methods

Patients with C. acnes PJI between January 2005 and December 2018 were retrospectively reviewed utilizing the institutional total joint registry. Patients with monomicrobial PJI and two or more positive cultures were considered to have true C. acnes PJI. Patients with polymicrobial infection or with only one positive culture were excluded. This resulted in 35 PJIs (21 hips and 14 knees); the patients’ mean age was 63 years (35 to 84) and 15 (43%) were female. Mean follow-up was five years (1 to 14).


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1385 - 1392
1 Dec 2024
French JMR Woods A Sayers A Deere K Whitehouse MR

Aims. Day-case knee and hip replacement, in which patients are discharged on the day of surgery, has been gaining popularity during the last two decades, and particularly since the COVID-19 pandemic. This systematic review presents the evidence comparing day-case to inpatient-stay surgery. Methods. A systematic literature search was performed of MEDLINE, Embase, and grey literature databases to include all studies which compare day-case with inpatient knee and hip replacement. Meta-analyses were performed where appropriate using a random effects model. The protocol was registered prospectively (PROSPERO CRD42023392811). Results. A total of 38 studies were included, with a total of 83,888 day-case procedures. The studies were predominantly from the USA and Canada, observational, and with a high risk of bias. Day-case patients were a mean of 2.08 years younger (95% CI 1.05 to 3.12), were more likely to be male (odds ratio (OR) 1.3 (95% CI 1.19 to 1.41)), and had a lower mean BMI and American Society of Anesthesiologists grades compared with inpatients. Overall, day-case surgery was associated with significantly lower odds of readmission (OR 0.83 (95% CI 0.73 to 0.96); p = 0.009), subsequent emergency department attendance (OR 0.62 (95% CI 0.48 to 0.79); p < 0.001), and complications (OR 0.7 (95% CI 0.55 to 0.89) p = 0.004), than inpatient surgery. There were no significant differences in the rates of reoperation or mortality. The overall rate of successful same-day discharge for day-case surgery was 85% (95% CI 81 to 88). Patient-reported outcome measures and cost-effectiveness were either equal or favoured day-case. Conclusion. Within the limitations of the literature, in particular the substantial risk of selection bias, the outcomes following day-case knee and hip replacement appear not to be inferior to those following an inpatient stay. The evidence is more robust for unicompartmental knee replacement (UKR) than for total knee replacement (TKR) or total hip replacement (THR). The rate of successful same-day discharge is highest in UKR, followed by TKR and comparatively lower in THR. Cite this article: Bone Joint J 2024;106-B(12):1385–1392