Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 5 - 5
1 Mar 2013
King R Ikram A
Full Access

Background. This is a continued assessment of the effectiveness of a locked intramedullary device in the treatment of acute clavicle shaft fractures. Results of patients treated thus far were assessed, including patients reported on previously. Description of methods. Patients admitted with midshaft clavicle fractures were assessed to determine whether operative fixation of the fracture was required. Indications for surgery were midshaft clavicle fractures with 100% displacement; more than 1.5 cm of shortening, presence of a displaced butterfly segment, bilateral clavicle fractures, ipsilateral displaced glenoid neck fractures, skin and neurovascular compromise. Patients that matched the criteria for surgery were treated operatively with an intramedullary locked device by the author. Post-operatively, patients were kept in a shoulder immobilizer for a period of 6 weeks. Patients were invited to attend a scheduled follow-up visit where the data was collected that comprised the review. All patients were assessed by the surgeon, a radiologist, a physiotherapist and an occupational therapist. Scar size and quality, Dash score, Constant Shoulder score, complications and the radiological picture were assessed. Summary of results. 50 patients (52 clavicle fractures – 2 patients sustained bilateral fractures), 28 males and 22 females with a mean age of 30 attended the schedule data collection visit and were included in the study. 48 clavicles achieved complete union with the remaining 4 fractures progressing normally to union at 10 and 12 weeks post surgery. No additional complications than those reported on previously were encountered. Conclusion. Locked intramedullary fixation of clavicle shaft fractures that match the criteria for operative fixation continues to give good results. No non-unions were found and a high level of patient satisfaction was achieved. The operative technique continues to be refined leading to less fixation related complications. MULTIPLE DISCLOSURES


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 66 - 66
1 Mar 2010
Gregory J Carrothers A Williams D Cool W
Full Access

Endoprosthetic replacement is often the preferred treatment for neoplastic lesions as internal fixation has been shown to have a high failure rate. Due to anatomical location, disease factors and patient factors internal fixation may be the treatment of choice. No reports exist in the literature regarding the use of locking plates in the management of neoplastic long bone lesions. Data was collected prospectively on the first 10 patients who underwent locking plate fixation of neoplastic long bone lesions. Data was collected on the nature of the lesion, surgery performed, complications and outcome. The patients mean age was 56.6 (15–88). Six lesions were metastatic, one haematological (myeloma) and 3 were primary bone lesions (lymphoma, Giant cell tumour, simple bone cyst). In nine cases a fracture through the lesion had occurred. Anatomical locations of the lesions were; proximal humerus (four), proximal tibia (three), distal femur (two) and distal tibia (one). Cement augmentation of significant bone defects was necessary in seven cases. The mean hospital stay was 8 days (3–20). There were no inpatient complications. Five patients received adjuvant radiotherapy and one patient received neo-adjuvant radiotherapy to the lesion. There have been 3 deaths. All were due to metastatic disease and occurred between 6 and 12 months after surgery. The mean follow up in the surviving patients is currently 9 months (5–16). There have been no fixation related complications. Patients who had suffered a fracture had restoration of their WHO performance status. At last follow up the mean MSTS was 78% (57–90) for lower limb surgery and 70% (63–76) for upper limb surgery. These figures compare favourably with the results of endoprosthetic replacement. The early results of locking plate fixation for neoplastic long bone lesions are excellent. Follow up continues to observe how these devices perform in the long term