Advertisement for orthosearch.org.uk
Results 1 - 20 of 63
Results per page:
Bone & Joint 360
Vol. 14, Issue 1 | Pages 22 - 23
1 Feb 2025

The February 2025 Sports Roundup. 360. looks at: Long-term outcomes of focal cartilage lesions of the knee; Comparison of early and delayed multiligament knee reconstruction; Platelet-rich plasma does not improve recovery after partial meniscectomy; Patient height and sex predict semitendinosus autograft diameter


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 239 - 245
1 Feb 2025
Evenhuis RE Bus MPA van Nes J Walter SG Cabrolier J Fiocco M van der Wal RJP Broekhuis D Sellevold S van de Sande MAJ

Aims

Over time, the locking mechanism of Modular Universal Tumour and Revision System (MUTARS) knee arthroplasties changed from polyethylene (PE) to polyether-ether-ketone Optima (PEEK) and metal-on-metal (MoM) in an attempt to reduce the risk of mechanical failure. In this study, we aimed to assess the cumulative incidence of locking mechanism revision for symptomatic instability by type of material, and assess potential associated risk factors.

Methods

The MUTARS Orthopaedic Registry Europe was used for a retrospective review of 316 patients (54% male (n = 170), median age 44 years (IQR 23 to 61)) who underwent a MUTARS knee arthroplasty for oncological indications between December 1995 and January 2023. The minimum follow-up was 12 months, and the median follow-up was 7.9 years (IQR 3.3 to 13.0). A competing risk model was used to estimate the cumulative incidence of first locking mechanism revision with death and revision for any other reason as competing events. Possible risk factors were assessed employing a univariate cause-specific hazards regression model.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 24 - 26
1 Oct 2024

The October 2024 Knee Roundup360 looks at: Managing the unexpected: treatment of intraoperative medial collateral ligament injuries; Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: secondary analysis of data from a randomized controlled trial; Cost-effectiveness of enoxaparin versus aspirin in the prevention of venous thromboembolism after total hip or knee arthroplasty: an analysis from the CRISTAL cluster-randomized trial; Cartilage regeneration and long-term survival in medial knee osteoarthritis patients treated with high tibial osteotomy and osteochondral autologous transfer system; Treatment of chronic and complex meniscal tears with arthroscopic meniscus repair augmented with collagen matrix wrapping: failure rate and functional outcomes; Long-term outcomes of multiligament knee injuries in American football players.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 516 - 521
1 Jun 2024
Al-Hourani K Haddad FS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 2 - 2
1 Dec 2023
Basheer S Kwaees T Tang C Ali F Haslam P Nicolaou N
Full Access

Objectives. Congenital cruciate ligament deficiency is a rare condition that may occur in isolation or in association with longitudinal limb deficiencies such as fibular hemimelia or proximal femoral focal deficiency. Often anomalies of the menisci and their attachments can be very abnormal and impact on surgical management by standard techniques. Arthroscopic surgical knee reconstruction is undertaken to improve symptomatic instability and/or to stabilise and protect the knee for future planned limb lengthening surgery. The aim of this study is to evaluate the arthroscopic findings of patients undergoing surgery for congenital cruciate ligament deficiency, and specifically to determine the frequency and types of meniscal anatomical variations seen in these cases. Methods. Patients undergoing surgery for congenital cruciate ligament deficiency were identified from a prospectively collated database. Diagnosis was confirmed through review of the clinical notes and imaging. Operative notes and 4K saved arthroscopic images and video recordings for these cases were reviewed. Results. Over a six-year period (July 2017 – September 2023), 42 patients underwent surgery for congenital ligament deficiency and tibiofemoral instability (45 surgical episodes). Median age of patients at time of surgery was 10 years (range 4 – 17 years). The most frequent diagnosis was congenital longitudinal limb deficiency syndromes in 27 cases, with the most frequent being fibular hemimelia. Isolated congenital ligament deficiency without any other associated extra-articular manifestations occurred in 11 cases. Absence of meniscal root attachments or hypertrophy of meniscofemoral ligaments acting as ‘pseudo-cruciates’ were seen in over 25% of patients. In isolated ACL deficiency these were injured causing onset of instability symptoms and pain following trauma. Often these abnormal structures required addressing to allow surgical reconstruction. Conclusions. Our findings demonstrate that there are often meniscal variations seen in association with congenital absence or hypoplasia of the cruciate ligaments. In these patients hypertrophied meniscofemoral ligaments may act as cruciate-like structures and play a role in providing a degree of sagittal plane stability to the knee. However, when the knee becomes unstable to the point that cruciate ligament reconstruction is indicated, these meniscal variants may often require stabilisation using complex meniscal root repair techniques or variations to standard cruciate ligament reconstruction techniques to accommodate the variant anatomy


Bone & Joint 360
Vol. 12, Issue 2 | Pages 42 - 44
1 Apr 2023

The April 2023 Research Roundup360 looks at: Ear protection for orthopaedic surgeons?; Has arthroscopic meniscectomy use changed in response to the evidence?; Time to positivity of cultures obtained for periprosthetic joint infection; Bisphosphonates for post-COVID-19 osteonecrosis of the femoral head; Missing missed fractures: is AI the answer?; Congenital insensitivity to pain and correction of the knee; YouTube and paediatric elbow injuries.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 94 - 94
1 Dec 2022
Versteeg A Chisamore N Ng K Elmoursi O Leroux T Zywiel M
Full Access

While surgeon-industry relationships in orthopaedics have a critical role in advancing techniques and patient outcomes, they also present the potential for conflict of interest (COI) and increased risk of bias in surgical education. Consequently, robust processes of disclosure and mitigation of potential COI have been adopted across educational institutions, professional societies, and specialty journals. The past years have seen marked growth in the use of online video-based surgical education platforms that are commonly used by both trainees and practicing surgeons. However, it is unclear to what extent the same COI disclosure and mitigation principles are adhered to on these platforms. Thus, the purpose of the present study was to evaluate the frequency and adequacy of potential COI disclosure on orthopaedic online video-based educational platforms. We retrospectively reviewed videos from a single, publicly-accessible online peer-to-peer orthopaedic educational video platform (VuMedi) that is used as an educational resource by a large number of orthopaedic trainees across North America. The 25 highest-viewed videos were identified for each of 6 subspecialty areas (hip reconstruction, knee reconstruction, shoulder/elbow, foot and ankle, spine and sports). A standardized case report form was developed based on the COI disclosure guidelines of the American Academy of Orthopaedic Surgery (AAOS) and the Journal of Bone and Joint Surgery. Two reviewers watched and assessed each video for presentation of any identifiable commercial products or brand names, disclosure of funding source for video, and presenter's potential conflict of interest. Additionally, presenter disclosures were cross-referenced against commercial relationships reported in the AAOS disclosure database to determine adequacy of disclosure. Any discrepancies between reviewers were resolved by consensus wherever possible, or with adjudication by a third reviewer when necessary. Out of 150 reviewed videos, only 37 (25%) included a disclosure statement of any kind. Sixty-nine (46%) videos involved the presentation of a readily identifiable commercial orthopaedic device, implant or brand. Despite this, only 13 of these (19%) included a disclosure of any kind, and only 8 were considered adequate when compared to the presenter's disclosures in the AAOS database. In contrast, 83% of the presenters of the videos included in this study reported one or more commercial relationships in the AAOS disclosure database. Videos of presentations given at conferences and/or academic meetings had significantly greater rates of disclosure as compared to those that were not (41% vs 14%; p=0.004). Similarly, disclosures associated with conference/meeting presentations had significantly greater rates of adequacy (21% vs 7%; p=0.018). Even so, less than half of the educational videos originating from a conference or meeting included a disclosure of any kind, and only about half of these were deemed adequate. No differences were seen in the rate of disclosures between orthopaedic subspecialties (p=0.791). Online orthopaedic educational videos commonly involve presentation of specific, identifiable commercial products and brands, and the large majority of presenters have existing financial relationships with potential for conflict of interest. Despite this, the overall rate of disclosure of potential conflict of interest in these educational videos is low, and many of these disclosures are incomplete or inadequate. Further work is needed to better understand the impact of this low rate of disclosure on orthopaedic education both in-training and in practice


Bone & Joint Open
Vol. 3, Issue 3 | Pages 173 - 181
1 Mar 2022
Sobol KR Fram BR Strony JT Brown SA

Aims

Endoprosthetic reconstruction with a distal femoral arthroplasty (DFA) can be used to treat distal femoral bone loss from oncological and non-oncological causes. This study reports the short-term implant survivorship, complications, and risk factors for patients who underwent DFA for non-neoplastic indications.

Methods

We performed a retrospective review of 75 patients from a single institution who underwent DFA for non-neoplastic indications, including aseptic loosening or mechanical failure of a previous prosthesis (n = 25), periprosthetic joint infection (PJI) (n = 23), and native or periprosthetic distal femur fracture or nonunion (n = 27). Patients with less than 24 months’ follow-up were excluded. We collected patient demographic data, complications, and reoperations. Reoperation for implant failure was used to calculate implant survivorship.


Bone & Joint Research
Vol. 11, Issue 2 | Pages 91 - 101
1 Feb 2022
Munford MJ Stoddart JC Liddle AD Cobb JP Jeffers JRT

Aims

Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia.

Methods

In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 11 - 11
1 Jun 2021
Munford M Jeffers J
Full Access

OSSTEC is a pre-spin-out venture at Imperial College London seeking industry feedback on our orthopaedic implants which maintain bone quality in the long term. Existing orthopaedic implants provide successful treatment for knee osteoarthritis, however, they cause loss of bone quality over time, leading to more dangerous and expensive revision surgeries and high implant failure rates in young patients. OSSTEC tibial implants stimulate healthy bone growth allowing simple primary revision surgery which will provide value for all stakeholders. This could allow existing orthopaedics manufacturers to capture high growth in existing and emerging markets while offering hospitals and surgeons a safer revision treatment for patients and a 35% annual saving on lifetime costs. For patients, our implant technology could mean additional years of quality life by revising patients to a primary TKA before full revision surgery. Our implants use patent-filed additive manufacturing technology to restore a healthy mechanical environment in the proximal tibia; stimulating long term bone growth. Proven benefits of this technology include increased bone formation and osseointegration, shown in an animal model, and restoration of native load transfer, shown in a human cadaveric model. This technology could help capture the large annual growth (24%) currently seen in the cementless knee reconstruction market, worth $1.2B. Furthermore, analysis suggests an additional market of currently untreated younger patients exists, worth £0.8B and growing by 18% annually. Making revision surgery and therefore treatment of younger patients easier would enable access to this market. We aim to offer improved patient treatment via B2B sales of implants to existing orthopaedic manufacturer partners, who would then provide them with instrumentation to hospitals and surgeons. Existing implant materials provide good options for patient treatments, however OSSTEC's porous titanium structures offer unique competitive advantages; combining options for modular design, cementless fixation, initial bone fixation and crucially long term bone maintenance. Speaking to surgeons across global markets shows that many surgeons are keen to pursue bone preserving surgeries and the use of porous implants. Furthermore, there is a growing demand to treat young patients (with 25% growth in patients younger than 65 over the past 10 years) and to use cementless knee treatments, where patient volume has doubled in the past 4 years and is following trends in hip treatments. Our team includes engineers and consultant surgeons who have experience developing multiple orthopaedic implants which have treated over 200,000 patients. To date we have raised £175,000 for the research and development of these implants and we hope to gain insight from industry professionals before further development towards our aim to begin trials for regulatory approval in 2026. OSSTEC implants provide a way to stimulate bone growth after surgery to reduce revision risk. We hope this could allow orthopaedic manufactures to explore high growth markets while meaning surgeons can treat younger patients in a cost effective way and add quality years to patients' lives


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1743 - 1751
1 Dec 2020
Lex JR Evans S Cool P Gregory J Ashford RU Rankin KS Cosker T Kumar A Gerrand C Stevenson J

Aims

Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients.

Methods

MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 54 - 54
1 Oct 2020
Freiman S Schwabe M Pashos G Barrack RL Nunley R Adelani M Pascual-Garrido C Clohisy J Lawrie C
Full Access

Introduction. The purpose of the study was to determine access to and, ability to use telemedicine technology in an adult hip and knee reconstruction patient population and we seek to understand these patients' perceived benefits, risks and preferences of telemedicine. Methods. We performed a cross-sectional telephone administered survey on patients scheduled to undergo primary THA and TKA by one of six surgeons at a single academic institution between March 23 and June 2, 2020. Results. 163 patients were contacted and 113 (69.3%) completed the survey. Of the patients that completed surveys, 88% of patients reported using the internet with 94% reporting owning a device capable of videoconferencing. 78% of patients had participated in a video call in the past year and 37% having done a video visit with their physician. When asked for their preferred method for a physician visit, 80% ranked in-person as their first choice, followed by 18% preferring a video visit. Perceived benefits of telemedicine visits included reduced travel to appointments (87% agree or strongly agree) and reduced cost of attending appointments (63% agree or strongly agree). However, patients were concerned that they would not establish the same patient-physician connection (51% agree or strongly agree) and would not receive the same level of care (33% agree or strongly agree) through telemedicine visits versus in person visits. Conclusion. The majority of total hip and knee arthroplasty patients have access to and are capable of using the technology required for telemedicine visits. However, patients still prefer to have in person visit over concern that they will not establish the same patient-physician connection and will not receive the same level of care, despite benefits of reduced time spent traveling to and cost of attending appointments, and making it easier to attend appointments


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1248 - 1255
1 Sep 2020
Laufer A Frommer A Gosheger G Roedl R Broeking JN Toporowski G Rachbauer AM Vogt B

Aims

The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery.

Methods

This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 78 - 78
1 Aug 2020
Marwan Y Martineau PA Kulkarni S Addar A Algarni N Tamimi I Boily M
Full Access

The anterolateral ligament (ALL) is considered as an important stabilizer of the knee joint. This ligament prevents anterolateral subluxation of the proximal tibia on the femur when the knee is flexed and internally rotated. Injury of the ALL was not investigated in patients with knee dislocation. The aim of the current research is to study the prevalence and characteristics of ALL injury in dislocated knees. A retrospective review of charts and radiological images was done for patients who underwent multiligamentous knee reconstruction surgery for knee dislocation in our institution from May 2008 to December 2016. Magnetic resonance imaging (MRI) was used to describe the ALL injury. The association of ALL injury with other variables related to the injury and the patient's background features was examined. Forty-eight patients (49 knees) were included. The mean age of the patients was 32.3 ± 10.6 years. High energy trauma was the mechanism of dislocation in 28 (57.1%) knees. Thirty-one knees (63.3%) were classified as knee dislocation (KD) type IV. Forty-five (91.8%) knees had a complete ALL injury and three (6.1%) knees had incomplete ALL injury. Forty (81.6%) knees had a complete ALL injury at the proximal fibres of the ALL, while 23 (46.9%) knees had complete distal ALL injury. None of the 46 (93.9%) knees with lateral collateral ligament (LCL) injury had normal proximal ALL fibres (p = 0.012). Injury to the distal fibres of the ALL, as well as overall ALL injury, were not associated with any other variables (p >0.05). Moreover, all patients with associated tibial plateau fractures (9, 18.4%) had abnormality of the proximal fibres of the ALL (p = 0.033). High grade ALL injury is highly prevalent among dislocated knees. The outcomes of reconstructing the ALL in multiligamentous knee reconstruction surgery should be investigated in future studies


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 77 - 83
1 Jul 2019
James EW Blevins JL Gausden EB Turcan S Denova TA Satalich JR Ranawat AS Warren RF Ranawat AS

Aims

Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR.

Patients and Methods

Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m2 (19.5 to 55.7).


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims

The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR).

Patients and Methods

In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 133 - 133
1 Apr 2019
Higa M Nakayama H Yoshiya S
Full Access

Introduction. Although total knee replacement became a widespread procedure for the purpose of knee reconstruction, osteotomies around the knee were regularly performed. Total knee arthroplasty should be performed for advanced arthritis of the knee. With the advent of biplanar open wedge high tibial osteotomy (HTO) combined with locking plate fixation, HTO has been expanded and its surgical outcome has been improved in recent years. However, post-operative joint-line obliquity has been raised as a concern with this procedure, which may affect the outcome especially in the knees with severe varus deformity. Hence the purpose of this study is to analyze the compression and shear stresses in the knee cartilage with joint line obliquity after HTO. Methods. Using a three-dimensional computer aided design software, the digital knee model with soft tissues was developed. The geometrical bone data used in this study were derived from commercially available human bone digital anatomy media (3972 and 3976, Pacific Research Laboratories, Inc., WA, USA). The three-dimensional knee model was transferred to finite element model. Material properties of the soft tissues and bones were derived from previous studies. The loading condition was adjusted to the load during a single-leg stance of the gait cycle, which resulted in an axial compressive load of 1200 N. Two different conditions were subjected to the analysis: normal alignment and joint-line obliquity after HTO. For the normal alignment, a static force of 1200 N was applied along the mechanical axis. For the joint-line obliquity models, a single force of 1200 N was applied rotating force directions in the frontal plane from the normal direction by 2.5º, 5º, 7.5º, and 10º, respectively. Results. The maximum values of the axial stresses in the cartilages for the normal condition showed almost same values in medial and lateral compartments. In the joint-line obliquity models, the maximum axial stress values in the medial compartment did not exhibit substantial change up to the level of 7.5º obliquity, while a rise in maximum stress value was observed for the model with 10º obliquity. The shear stress showed a different tendency. In the joint-line obliquity models, a steep rise of laterally directed shear stress in the medial compartment was observed for models with obliquity of 5º or more. Discussion. The shear stress in the medial cartilage increased to almost twice as high as the normal knee level for the joint- line obliquity model with an inclination of 5º. The maximum shear stress values increased in accordance with the obliquity angle. The elevated stress could be deleterious to the cartilage. In such large amount of correction by tibial osteotomy leads to unfavorable mechanical environment in the knee. For those severe situations, double-level osteotomy, which retains anatomical knee joint line by simultaneous femoral and tibial osteotomies, should be considered to correct the joint-line obliquity


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 1 - 1
1 Jan 2019
Greenwald AS


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1640 - 1646
1 Dec 2018
Medellin MR Fujiwara T Clark R Jeys LM

Aims

The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses.

Patients and Methods

A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System.