Advertisement for orthosearch.org.uk
Results 1 - 20 of 633
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 36 - 36
22 Nov 2024
Goumenos S Hipfl C Michalski B Pidgaiska O Mewes M Stöckle U Perka C Meller S
Full Access

Background. Postoperative dislocation is one of the main surgical complications and the primary cause for revision surgery after 2-stage implant exchange due to periprosthetic infection of a total hip arthroplasty. Objective. The aims of our study were (1) to determine the incidence of dislocation after two-stage THA reimplantation without spacer placement, (2) to evaluate relevant risk factors for dislocation and (3) to assess the final functional outcome of those patients. Method. We prospectively analyzed 187 patients who underwent a two-stage total hip arthroplasty (THA) revision after being diagnosed with periprosthetic joint infection (PJI) from 2013 to 2019. The mean duration of follow-up was 54.2 ± 24.9 months (>36 months). The incidence of postoperative dislocation and subsequent revision was estimated through Kaplan-Meier curves and potential risk factors were identified using Cox hazard regression. The functional outcome of the patients was assessed using the modified Harris Hip Score (mHHS). Results. The estimated cumulative dislocation-free survival was 87.2% (95% CI: 81.2%-91.3%) with an estimated 10% and 12% risk for dislocation within the first 6 and 12 months, respectively. The use of a dual-mobility construct had no significant impact on the dislocation rate. Increasing body mass index (BMI) (HR=1.11, 95% CI: 1.02-1.19, p=0.011), abductor mechanism impairment (HR=2.85, 95% CI: 1.01-8.01, p=0.047), the extent of elongation of the affected extremity between stages (HR=1.04, 95% CI: 1.01-1.07, p=0.017), the final leg length discrepancy (HR=1.04, 95% CI: 1.01-1.08, p=0.018) and PJI recurrence (HR=2.76, 95% CI: 1.00-7.62, p=0.049) were found to be significant risk factors for dislocation. Overall revision rates were 17% after THA reimplantation. Dislocated hips were 62% more likely to undergo re-revision surgery (p<0.001, Log-rank= 78.05). A significant average increase of 30 points in mHHS scores after second-stage reimplantation (p=0.001, Wilcoxon-rank) was recorded, but no difference was noted in the final HHS measurements between stable and dislocated hips. Conclusion. Dislocation rates after 2-stage THA reimplantation for PJI remain high, especially regarding overweight or re-infected patients. Careful leg length restoration and an intact abductor mechanism seem critical to ensure stability in these complex patients


Bone & Joint Open
Vol. 5, Issue 10 | Pages 868 - 878
14 Oct 2024
Sekita T Asano N Kobayashi H Yonemoto T Kobayashi E Ishii T Kawai A Nakayama R

Aims

Surgical limb sparing for knee-bearing paediatric bone sarcoma is considered to have a clinically significant influence on postoperative function due to complications and leg-length discrepancies. However, researchers have not fully evaluated the long-term postoperative functional outcomes. Therefore, in this study, we aimed to elucidate the risk factors and long-term functional prognosis associated with paediatric limb-sparing surgery.

Methods

We reviewed 40 patients aged under 14 years who underwent limb-sparing surgery for knee bone sarcoma (15 cases in the proximal tibia and 25 in the distal femur) between January 2000 and December 2013, and were followed up for a minimum of five years. A total of 35 patients underwent reconstruction using artificial materials, and five underwent biological reconstruction. We evaluated the patients’ postoperative complications, survival rate of reconstruction material, and limb, limb function, and leg-length discrepancy at the final follow-up, as well as the risk factors for each.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 9 - 9
11 Oct 2024
Zace P Maas Z McIntyre R Khan Z Bailey O
Full Access

Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major leg length discrepancy of over 2cm between the pre-calibrated and post-calibrated X-Rays. Pelvic X-Rays of 80 patients that underwent total hip replacement were reviewed. Preoperative templating was compared to the implants inserted. An average of 1.94 discrepancy in the size of the acetabular implant was identified whilst in 30 cases the size of the femoral stem was incorrect by at least 1 size. Magnification of 119.7% on X-Rays was found to provide the most accurate templating. Seventy seven cases of pelvic X-Rays before and after hip hemiarthroplasty were also reviewed. The implant head was templated incorrectly in 74% of cases and the stem in 51%. It was identified that pelvic X-Ray magnification of 121.7% would provide the most accurate results. X-Rays with no calibration probes provide inaccurate measurements leading to faulty preoperative planning. Standardised use of a calibration sphere is strongly suggested and whenever that is not available, we suggest magnification of 121%


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims

Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context.

Methods

A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims

The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system.

Methods

This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 688 - 696
22 Aug 2024
Hanusrichter Y Gebert C Steinbeck M Dudda M Hardes J Frieler S Jeys LM Wessling M

Aims

Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction.

Methods

Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 19 - 19
19 Aug 2024
Macheras G Kostakos T Tzefronis D
Full Access

Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of leg length discrepancy (LLD) was present, requiring shortening femoral osteotomy. 12 patients underwent sequential proximal femoral resection with trochanteric osteotomy, 46 subtrochanteric, 6 midshaft, and 25 distal femoral osteotomies with simultaneous valgus correction were performed. All acetabular prostheses were placed in the true anatomical position. We used uncemented high porosity cups. Patients were followed up for a minimum of 12 months. All osteotomies healed uneventfully except 3 non-unions of the greater trochanter in the proximal femur resection group. No femoral shaft fractures in proximally based osteotomies. No significant LLD compared to the unaffected or reconstructed side. 2 patients suffered 3 and 5 degrees malrotation of the femur in the oblique sub-trochanteric group. 3 patients suffered transient sciatic nerve palsies. Shortening femoral osteotomies in the treatment of DDH are necessary to avoid injury to the sciatic nerve. In our series, we found transverse subtrochanteric osteotomies to be the most technically efficient, versatile and predictable in their clinical outcome, due to the ability to correct rotation and preserve the metaphyseal bone integrity, allowing for better initial stem stability. Distal femoral osteotomies allowed for controllable correction of valgus knee deformity


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 93 - 93
19 Aug 2024
Schaffler BC Robin JX Katzman JL Manjunath A Davidovitch R Rozell JC Schwarzkopf R
Full Access

The purpose of this study was to assess the variability in implant position between sides in patients who underwent staged, bilateral THA and whether variation from one side to the other affected patient-reported outcomes. A retrospective review was conducted on 207 patients who underwent staged, bilateral THA by the same surgeon from 2017–2022. Leg length, acetabular height, cup version, and coronal and sagittal stem angles were assessed radiographically and compared to the contralateral THA. Surgical approach and technology utilization were further assessed for their impact on variability. Linear regression was used to model the relationship between side-to-side variability and patient-reported outcome measures (PROMS). Between sides, mean radiographic leg length varied by 4.6mm (0.0–21.2), acetabular height varied by 3.3mm (0.0–13.7), anteversion varied by 8.2° (0.0 to 28.7), coronal stem alignment varied by 1.1° (0.0 to 6.9), and sagittal angulation varied by 2.3° (0.0 to 10.5). The anterior approach resulted in more variability in stem angle position in both the coronal (1.3° vs. 1.0°, p=0.036) and sagittal planes (2.8° vs. 2.0° p=0.012) compared to the posterior approach. The posterior approach generally led to more anteversion than the anterior approach. Use of robotics or navigation for acetabular positioning did not increase side-to-side variability in cup-related position or leg length. Despite considerable side-to-side variability, Hip dysfunction and osteoarthritis outcome scores (HOOS JR) were not affected by higher levels of position inconsistency. Staged, bilateral THA results in considerable variability in component position between sides. The anterior approach leads to more side-to-side variability in sagittal stem angle and cup anteversion than the posterior approach. Navigation and robotics do not improve the consistency of component position in bilateral THA. Variation in implant position was not associated with differences in PROMs, suggesting that despite variability, patients can tolerate these differences between sides


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 79 - 79
19 Aug 2024
Hormi-Menard M Wegrzyn J Girard J Faure P Duhamel A Erivan R Migaud H
Full Access

The results of total hip arthroplasty (THA) revisions to correct leg length discrepancy (LLD) are not clear, with only two former limited series (< 25 patients). Therefore, we conducted a retrospective study of THA revisions for LLD to determine: 1) the change in LLD, 2) the function outcomes and whether obtaining equal leg lengths influenced function, 3) the complication and survival rates. This multicenter study included 57 patients: 42 THA revisions for limb shortening and 15 revisions for limb lengthening. LLD was measured on conventional radiographs and EOS. The Oxford-12 and FJS outcome scores were collected and the number of patients achieving the Oxford-12 MCID. The revisions were carried out a mean of 2.8 years after the index THA. The median LLD decreased from 7.5 mm (IQR: [5;12]) to 1 mm (IQR: [0.5;2.5]) at follow-up (p=0.0002). Overall, 55 of 57 patients (96%) had < 5 mm LLD at follow-up and 12 patients (21%) had equal leg lengths. The complication rate was 25%: 12 mechanical complications (8 periprosthetic femoral fractures, 2 stem loosening and 1 cup loosening, 1 dislocation) and 1 periprosthetic infection. The patient satisfaction was high with a median FJS of 79.2/100 and 77% of patients reached the Oxford-12 MCID. Lengthening procedures had significantly worst function than shortening (38% vs 91% of patients achieving the Oxford-12 MCID (p=0.0004)). Survivorship was 85% (95% CI: 77.9 – 92.5) at 2 years and 77% (95% CI: 66.3 – 87.1) at 4.6 years when using re-revision for any reason as the endpoint. When LLD after THA does not respond to conservative management, revision THA should be considered. Although revision THA for LLD improved medium-term functional outcomes with a high patient satisfaction rate, especially for shortening procedures, the complication rate was high, particularly related to periprosthetic femoral fracture


Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 514 - 523
24 Jun 2024
Fishley W Nandra R Carluke I Partington PF Reed MR Kramer DJ Wilson MJ Hubble MJW Howell JR Whitehouse SL Petheram TG Kassam AM

Aims

In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.

Methods

Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). Results. DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. Conclusion. We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability. Cite this article: Bone Joint J 2024;106-B(5 Supple B):89–97


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 105 - 111
1 May 2024
Apinyankul R Hong C Hwang KL Burket Koltsov JC Amanatullah DF Huddleston JI Maloney WJ Goodman SB

Aims

Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocation. The aim of this study was to assess the risk for recurrent dislocation after revision THA for instability.

Methods

Between 2009 and 2019, 163 patients underwent revision THA for instability at Stanford University Medical Center. Of these, 33 (20.2%) required re-revision due to recurrent dislocation. Cox proportional hazard models, with death and re-revision surgery for periprosthetic infection as competing events, were used to analyze the risk factors, including the size and alignment of the components. Paired t-tests or Wilcoxon signed-rank tests were used to assess the outcome using the Veterans RAND 12 (VR-12) physical and VR-12 mental scores, the Harris Hip Score (HHS) pain and function, and the Hip disability and Osteoarthritis Outcome score for Joint Replacement (HOOS, JR).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 22 - 22
23 Apr 2024
Laufer A Frommer A Gosheger G Toporowski G Rölfing JD Antfang C Roedl R Vogt B
Full Access

Introduction. Coronal malalignment and leg length discrepancies (LLD) are frequently associated. Temporary hemiepiphysiodesis (tHED) is commonly employed for the correction of limb malalignment in skeletally immature patients. For treatment of LLD greater than 2 cm, lengthening with intramedullary legnthening nails is a safe and reliable technique. However, the combined application of these approaches in skeletally immature patients has not yet been investigated. Materials & Methods. Retrospective radiological and clinical analysis of 25 patients (14 females, 11 males) who underwent intramedullary femoral lengthening with an antegrade PRECICE® lengthening nail as well as tHED of the distal femur and / or proximal tibia between 2014 and 2019. tHED was conducted by implantation of flexible staples (FlexTack™) either prior (n = 11), simultaneously (n = 10), or subsequently (n = 4) to femoral lengthening. The mean follow-up period was 3.7 years (±1.4). Results. The median initial LLD was 39.0 mm (35.0–45.0). 21 patients (84%) presented valgus and 4 (16%) showed varus malalignment. Leg length equalization was achieved in 13 patients at skeletal maturity (62%). The median LLD of patients with a residual LLD > 10 mm was 15.5 mm (12.8–21.8). Limb realignment was obtained in nine of seventeen skeletally mature patients (53%) in the valgus group, and in one of four patients (25%) in the varus group. Conclusions. The combination of antegrade femoral lengthening and tHED can efficiently correct LLD and coronal limb malalignment in skeletally immature patients. Nevertheless, achieving limb length equalization and realignment may render difficult in cases of severe LLD and angular deformity. Furthermore, the reported techniques ought to be thoroughly planned and executed and require regular clinical and radiological examinations until skeletal maturity to avoid - or timely detect and manage - adverse events such as overcorrection and rebound of deformity


Bone & Joint 360
Vol. 13, Issue 2 | Pages 41 - 44
1 Apr 2024

The April 2024 Children’s orthopaedics Roundup360 looks at: Ultrasonography or radiography for suspected paediatric distal forearm fractures?; Implant density in scoliosis: an important variable?; Gait after paediatric femoral shaft fracture treated with intramedullary nail fixation: a longitudinal prospective study; The opioid dilemma: navigating pain management for children’s bone fractures; 12- to 20-year follow-up of Dega acetabuloplasty in patients with developmental dysplasia of the hip; Physeal fractures of the distal ulna: incidence and risk factors for premature growth arrest; Analysis of growth after transphyseal anterior cruciate ligament reconstruction in children; Management of lateral condyle humeral fracture associated with elbow dislocation in children: a retrospective international multicentre cohort study.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results. There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and leg length (mean 0.6 mm vs 1.4 mm; p < 0.001). Patient-reported outcome measures were comparable between the two groups at baseline and one year. Participants in the RO THA group needed fewer physiotherapy sessions postoperatively (median six (IQR 4.5 to 8) vs eight (IQR 6 to 11; p = 0.005). Conclusion. This RCT suggested that robotic-arm assistance in THA was associated with improved accuracy in restoring the native COR, better preservation of the combined offset, leg length correction, and superior accuracy in achieving the desired acetabular component positioning. Further evaluation through long-term and registry data is necessary to assess whether these findings translate into improved implant survival and functional outcomes. Cite this article: Bone Joint J 2024;106-B(4):324–335


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 97 - 103
1 Mar 2024
Baujard A Martinot P Demondion X Dartus J Faure PA Girard J Migaud H

Aims

Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after total hip arthroplasty (THA). The most common initiator is anterior acetabular component protrusion, where the anterior margin is not covered by anterior acetabular wall. A CT scan can be used to identify and measure this overhang; however, no threshold exists for determining symptomatic anterior IP impingement due to overhang. A case-control study was conducted in which CT scan measurements were used to define a threshold that differentiates patients with IP impingement from asymptomatic patients after THA.

Methods

We analyzed the CT scans of 622 patients (758 THAs) between May 2011 and May 2020. From this population, we identified 136 patients with symptoms suggestive of IP impingement. Among them, six were subsequently excluded: three because the diagnosis was refuted intraoperatively, and three because they had another obvious cause of impingement, leaving 130 hips (130 patients) in the study (impingement) group. They were matched to a control group of 138 asymptomatic hips (138 patients) after THA. The anterior acetabular component overhang was measured on an axial CT slice based on anatomical landmarks (orthogonal to the pelvic axis).