Lower limb reconstruction (LLR) has a profound impact on patients, affecting multiple areas of their lives. Many patient-reported outcome measures (PROMs) are employed to assess these impacts; however, there are concerns that they do not adequately capture all outcomes important to patients, and may lack content validity in this context. This review explored whether PROMs used with adults requiring, undergoing, or after undergoing LLR exhibited content validity and adequately captured outcomes considered relevant and important to patients. A total of 37 PROMs were identified. Systematic searches were performed to retrieve content validity studies in the adult LLR population, and hand-searches used to find PROM development studies. Content validity assessments for each measure were performed following Consensus-based Standards for the selection of health measurement Instruments (COSMIN) guidelines. A mapping exercise compared all PROMs to a conceptual framework previously developed by the study team (‘the PROLLIT framework’) to explore whether each PROM covered important and relevant concepts.Aims
Methods
Introduction. Previous studies have shown the potential for virtual reality (VR) immersion as a promising technique for pain and anxiety management. The aim of our study was to evaluate the feasibility of VR in the management of pain and anxiety during post-op external fixator care procedures. Method. This study involved patients aged 5-21 years following
Introduction. The non-union of long bones poses a substantial challenge to clinicians and patients alike. The Ilizarov fixation system and
Two discrete legal factors enable the surgeon to treat an injured patient the fully informed, autonomous consent of the adult patient with capacity via civil law; and the medical exception to the criminal law. This article discusses current concepts in consent in trauma; and also considers the perhaps less well known medical exception to the Offences against the Person Act 1861, which exempts surgeons from criminal liability as long as they provide ‘proper medical treatment’. Cite this article:
Weightbearing instructions after musculoskeletal injury or orthopaedic surgery are a key aspect of the rehabilitation pathway and prescription. The terminology used to describe the weightbearing status of the patient is variable; many different terms are used, and there is recognition and evidence that the lack of standardized terminology contributes to confusion in practice. A consensus exercise was conducted involving all the major stakeholders in the patient journey for those with musculoskeletal injury. The consensus exercise primary aim was to seek agreement on a standardized set of terminology for weightbearing instructions.Aims
Methods
Introduction. Continuous compression implants (CCIs) are small memory alloy bone staples that can provide continuous compression across a fracture site, which change shape due to temperature changes. Reviews of CCIs in orthopaedics have documented their use in mainly foot and ankle surgery, with very limited descriptions in trauma. They could be beneficial in the management of complex or open injuries due to their low profile and quick insertion time. The aim of this case series were to clarify the use of CCIs in modern day
Introduction. Schatzker V & VI tibial plateau fractures are serious life-changing injuries often resulting in significant complications including post-traumatic arthritis. Reported incidence of secondary TKA following ORIF of all tibial plateau fractures is 7.3% and 13% for Schatzker V & VI tibial. This study reports a 15-year single centre experience of CEF of Schatzker V & VI fractures including PROMs and incidence of secondary TKA. This study was approved by the local Institutional board. Materials & Methods. All patients from 2007 – 2022 with Schatzker V or VI fractures treated with CEF were identified from a departmental
Introduction. The reconstruction of segmental long bone defects remains one of the holy grails of orthopaedic surgery. The optimal treatment of which remains a topic of great debate. This study aimed to evaluate the outcomes following the management of critical-sized bone defects using a classification-based treatment algorithm. Materials & Methods. A retrospective review of all patients undergoing treatment for segmental diaphyseal defects of long bones at a tertiary-level
The requirement for the peer support groups were born out of concern for the psychological wellbeing of the paediatric patients and to assess if this would improve their wellbeing during their treatment. Groupwork is a method of Social Work which is recognised as a powerful tool to allow people meet their need for belonging while also creating the forum for group members to empower one another. Social Work meet with all paediatric patients attending the
Introduction. Limb deformity is usually assessed clinically assisted by long leg alignment radiographs and further imaging modalities (MRI and CT). Often decisions are made based on static imaging and simple gait interpretation in clinic. We have assessed the value of gait lab analysis in surgical decision making comparing surgical planning pre and post gait lab assessment. Materials & Methods. Patients were identified from the local
Introduction. Management of deformity involving limb length discrepancy (LLD) using intramedullary devices offers significant benefits to both patients and clinicians over traditional external fixation. Following the withdrawal of the PRECICE nail, the Fitbone became the primary implant available for intramedullary lengthening and deformity correction within our service. This consecutive series illustrates the advantages and complications associated with the use of this device, and describes a novel technique modification for antegrade intramedullary lengthening nails. Materials & Methods. A retrospective cohort review was performed of patient outcomes after treatment with the Fitbone nail at two tertiary referral
Aims. Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest. Methods. A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British
The aim of this study was to perform the first population-based description of the epidemiological and health economic burden of fracture-related infection (FRI). This is a retrospective cohort study of operatively managed orthopaedic trauma patients from 1 January 2007 to 31 December 2016, performed in Queensland, Australia. Record linkage was used to develop a person-centric, population-based dataset incorporating routinely collected administrative, clinical, and health economic information. The FRI group consisted of patients with International Classification of Disease 10th Revision diagnosis codes for deep infection associated with an implanted device within two years following surgery, while all others were deemed not infected. Demographic and clinical variables, as well as healthcare utilization costs, were compared.Aims
Methods
The external fixator is an invaluable device when treating acute complex trauma and in
Introduction. Derotation osteotomies are commonly performed in paediatric orthopaedic and
Introduction. The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial plain x-ray imaging. One of the challenges here is that the relatively radio-opaque components of the circular external fixator (e.g. the rings) can obscure the view of the area of interest (e.g. osteotomy site, fracture site). In this presentation we describe how the geometry of the x-ray beam affects the produced image and how we can use knowledge of this to our advantage. Whilst this can be applied to any long bone, we have focused on the tibia, given that it's the most common long bone that is treated by circular external fixation. Materials & Methods. In the first part of the presentation we describe the known attributes (geometry) of the x-ray beam and postulate what effect it would have when we x-ray a long bone that is surrounded by a circular external fixator. In the second part we demonstrate this in practice using a tibia and a 3 ring circular external fixator. Differing x-ray beam orientations are used to demonstrate both how the geometry of the beam affects the produced image and how we can use this to our advantage to better visualise part of the bone. Results. The practical part of the study confirmed the theoretical part. Conclusions. Knowledge of the beam geometry can be used to minimise the obscuring nature of the circular fixator. This technique is simple and can be easily taught to the radiographer. It is a useful adjunct for the
Introduction. External fixation (EF) devices are commonly used in the management of complex skeletal trauma, as well as in elective
Introduction. External fixators are common surgical orthopaedic treatments for the management of complex fractures and in particular, the use of circular frame fixation within patients requiring