The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured.Aims
Methods
Our primary aim was to assess reoperation-free survival at one year after the index injury in patients aged ≥ 75 years treated with internal fixation (IF) or arthroplasty for undisplaced femoral neck fractures (uFNFs). Secondary outcomes were reoperations and mortality analyzed separately. We retrieved data on all patients aged ≥ 75 years with an uFNF registered in the Swedish Fracture Register from 2011 to 2018. The database was linked to the Swedish Arthroplasty Register and the National Patient Register to obtain information on comorbidity, mortality, and reoperations. Our primary outcome, reoperation, or death at one year was analyzed using restricted mean survival time, which gives the mean time to either event for each group separately.Aims
Methods
The April 2023 Trauma Roundup360 looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?
The February 2023 Hip & Pelvis Roundup360 looks at: Total hip arthroplasty or internal fixation for hip fracture?; Significant deterioration in quality of life and increased frailty in patients waiting more than six months for total hip or knee arthroplasty: a cross-sectional multicentre study; Long-term cognitive trajectory after total joint arthroplasty; Costal cartilage grafting for a large osteochondral lesion of the femoral head; Foley catheters not a problem in the short term; Revision hips still a mortality burden?; How to position implants with a robotic arm; Uncemented stems in hip fracture?
Periprosthetic joint infections (PJIs) and fracture-related infections (FRIs) are associated with a significant risk of adverse events. However, there is a paucity of data on cardiac complications following revision surgery for PJI and FRI and how they impact overall mortality. Therefore, this study aimed to investigate the risk of perioperative myocardial injury (PMI) and mortality in this patient cohort. We prospectively included consecutive patients at high cardiovascular risk (defined as age ≥ 45 years with pre-existing coronary, peripheral, or cerebrovascular artery disease, or any patient aged ≥ 65 years, plus a postoperative hospital stay of > 24 hours) undergoing septic or aseptic major orthopaedic surgery between July 2014 and October 2016. All patients received a systematic screening to reliably detect PMI, using serial measurements of high-sensitivity cardiac troponin T. All-cause mortality was assessed at one year. Multivariable logistic regression models were applied to compare incidence of PMI and mortality between patients undergoing septic revision surgery for PJI or FRI, and patients receiving aseptic major bone and joint surgery.Aims
Methods
Infection following total knee arthroplasty (TKA) can cause significant morbidity to the patient and be associated with significant costs and burdens to the healthcare system. Wound complications often initiate the cascade that can eventually lead to deep infection and implant failure. Galat et al. reported that wound complications following TKA requiring surgical treatment were associated with 2-year cumulative risks of
We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year.Aims
Patients and Methods
Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.Aims
Patients and Methods
Introduction. Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNF), especially in physiologically younger patients. While elective THA for primary osteoarthritis (OA) has demonstrated low rates of complications and readmissions, the outcomes of THA for FNF are less predictable. Additionally, these THA procedures are equally included in various alternative payment bundles. Therefore, the aim of this study is to assess postoperative complication rates after THA for primary OA compared with FNF. Methods. The American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database from 2008 to 2016 was queried. Patients were identified using the Current Procedural Terminology (CPT) code for THA (27130) and divided into groups by diagnosis; OA in one group and FNF in another. Univariate statistics were performed. T-test compared continuous variables between groups, and Chi-square test compared categorical variables. Multivariate and propensity matched logistic regression analyses were performed to control for risk factors of interest. The primary outcomes for this study were death or serious morbidity (surgical site infection (SSI), infection, respiratory complication, cardiac complication, sepsis, or blood loss anemia requiring postoperative transfusion). Additional secondary outcomes included the incidence of specific complications, total operative time (time from incision to closure), length of hospital stay and proportion of patients that were discharged home. Results. Analyses included 139,635 patients undergoing THA. OA was the indication in 135,013 cases and FNF in 4,622 cases. Unadjusted analysis showed a significantly higher rate of mortality when THA was done for hip fracture (2.1% vs. 0.1%; p<0.001). There was also a significantly increased rate of serious morbidity for hip fracture patients; including cardiac complications (3.5% vs 0.96%; p<0.001), respiratory complications (1.3% vs 0.2%; p<0.001), postop transfusion (23.1% vs 9.36%; p<0.001), sepsis (0.95% vs 0.3%; p<0.001). There was a significantly higher percentage of patients requiring reoperation (4.5% vs 2.0%; p<0.001) and readmission (8.0% vs 3.5%; p<0.001) in the hip fracture group. There was a significantly higher percentage of patients in the hip fracture groups having operative time >90min (16.4% vs 10.1%; p<0.001), length of stay longer than 5 days (53.8% vs 7.5%; p<0.001), and a significantly lower percentage of patients who were discharged home (39.0% vs 78.0%; p<0.001). Propensity score matching resulted in a cohort of 6,968 patients; 3,484 in both the hip fracture and osteoarthritis groups. Mortality within 30 days was 530% higher, and major morbidity was 36% higher among FNF patients. Reoperation was 40% higher, readmission was 36% higher, operative length at the 90th percentile was 74% higher, prolonged length of stay was 838% higher, and discharge to home was 62% lower for the FNF group compared with OA patients. Logistic, reverse stepwise regression model () results were consistent with the propensity-matched analysis. Discussion and Conclusion. This large database study showed a higher risk of postoperative complications including mortality,
Aims. To report our experience with trunnion corrosion following metal-on-polyethylene
total hip arthroplasty, in particular to report the spectrum of
presentation and determine the mean time to presentation. Patients and Methods. We report the presenting symptoms and signs, intraoperative findings,
and early results and complications of operative treatment in nine
patients with a mean age of 74 years (60 to 86). The onset of symptoms
was at a mean of seven years (3 to 18) after index surgery. Results. Patients presented with a variety of symptoms including pain,
limp and rash. The preoperative mean serum cobalt level was 7.1 ppb
(2.2 to 12.8) and mean serum chromium level was 2.2 ppb (0.5 to
5.2). Metal artifact reduction sequence (MARS) MRI showed fluid
collection and possible pseudotumour formation in five hips, fluid
collection in two hips, and synovitis/debris in one hip, with no
MRI in one patient. Acetabular revision was performed in three patients,
six patients underwent liner and head exchange only. The postoperative
metal levels decreased in all patients: mean cobalt 0.5 ppb (0 to
1.8) and mean chromium 0.9 ppb (0 to 2.6) at a mean of five months
(3 to 8) postoperatively. Seven patients had good pain relief and
no complications at one year. There were two
Infection following total knee arthroplasty (TKA) can cause significant morbidity to the patient and be associated with significant costs and burdens to the health care system. Wound complications often initiate the cascade that can eventually lead to deep infection and implant failure. Galat et al. reported that wound complications following TKA requiring surgical treatment were associated with a 2-year cumulative risk of
The extraordinary majesty of THR, as it burst onto the scene 60 years ago, both dazzled and blinded. It dazzled patients and surgeons alike and simultaneously obstructed a clear eyed assessment of the human costs. It behooves current practitioners, who have benefited mightily by our progress, to pause and reflect thoughtfully on that progress. Look no further than the fact that the treatment of a benign disease left one patient out of every 50 dead. Dead from a pulmonary embolus and that over 25% of the patients threw pulmonary emboli. What were the big six major disadvantages: 1) Fatal pulmonary emboli; 2) Prosthetic joint infection; 3) Failure of fixation; 4) Dislocation; 5) Periprosthetic osteolysis; 6) Prolonged hospitalization. Start with the observation that THR in the modern era began with Charnley's experiment with Teflon articulations. Of the nearly 300 such operations done, nearly 300 failed. Ultrahigh molecular weight polyethylene was better- much better. But still it produced wear and periprosthetic osteolysis, afflicting an estimated 1 million patients. Periprosthetic osteolysis became the most common reason for failure, the most common reason for reoperation, the most common reason for fracture, and the most common reason for extremely difficult re-operations requiring
We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression.Objectives
Methods
Cubitus varus is the most common late complication of a supracondylar
fracture of the humerus in children. Correction can be performed
using one of a number of techniques of osteotomy but each has disadvantages.
We describe a new technique for correcting post-traumatic cubitus
varus using a lateral closing wedge isosceles triangular osteotomy. A lateral closing wedge isosceles triangular osteotomy was performed
in 25 patients (15 male and ten female with a mean age of 9.5 years
(6 to 12)) between May 2010 and April 2013. All patients had cubitus
varus secondary to malunion of a supracondylar fracture, with good
function of the elbow and a full range of movement. The osteotomy
lines were marked on the bone with an isosceles triangular template
made before surgery, after which the osteotomy was performed leaving
the medial cortex intact. Fixation was performed using two lateral
2 mm Kirschner (K)-wires and patients were immobilised in an above-elbow
plaster. By six to eight weeks callus was present and the wires
and cast were removed. Patients were reviewed at four and six weeks,
three, six and 12 months and then every two years until skeletal
maturity. Clinical and radiographic outcomes were categorised as excellent,
good or poor.Aims
Patients and Methods
Introduction. The optimal bearing for hip arthroplasty is still a matter of debate. in younger and more active patients ceramic-on-polyethylene (CoP) bearings are frequently chosen over metal-on-polyethylene (MoP) bearings to reduce wear and increase biocompatibility. However, the fracture risk of ceramic heads is higher than that of metal heads. This can cause serious issue, as ceramic fractures pose a serious complication often necessitating
Given the increasing number of total hip arthroplasty
procedures being performed annually, it is imperative that orthopaedic
surgeons understand factors responsible for instability. In order
to treat this potentially complex problem, we recommend correctly
classifying the type of instability present based on component position, abductor
function, impingement, and polyethylene wear. Correct classification
allows the treating surgeon to choose the appropriate revision option
that ultimately will allow for the best potential outcome. Cite this article:
The April 2015 Hip &
Pelvis Roundup360 looks at: Goal-directed fluid therapy in hip fracture; Liberal blood transfusion no benefit in the longer term; Repeated measures: increased accuracy or compounded errors?; Peri-acetabular osteotomy safer than perhaps thought?; Obesity and peri-acetabular osteotomy: poor bedfellows; Stress fracture in peri-acetabular osteotomy; Infection and tantalum implants; Highly crosslinked polyethylene really does work
Vancouver B fractures around a cemented polished tapered stem (CTPS) are often treated with revision arthroplasty. Results of osteosynthesis in these fractures are poor as per current literature. However, the available literature does not distinguish between fractures around CTPS from those around other stems. The aim of our study was to assess the clinical and radiological outcome of open reduction and internal fixation in Vancouver B fractures around CTPS using a broad non-locking plate. Patients treated with osteosynthesis between January 1997 and July 2011 were retrospectively reviewed. All underwent direct reduction and stabilisation using cerclage wires before definitive fixation with a broad DCP. Bicortical screw fixation was obtained in the proximal and distal fragments. We defined failure of treatment as revision for any cause. 101 patients (42 men and 59 women, mean age 79) were included. 70 had minimum follow-up of 6 months. 63 of these went on to clinical and radiological union. Three developed infected non-union. 7 had failure of fixation. Lack of anatomical reduction was the commonest predictor of failure followed by inadequate proximal fragment fixation and infection. 14 patients dropped at least 1 mobility grade from their preoperative status. This is the largest series of a very specific group of periprosthetic fractures treated with osteosynthesis. Patients who develop these fractures are often frail and “high risk” for
Introduction. Many patients with displaced intracapsular femoral neck fractures (IFNF) are treated with hemiarthroplasty (HA) which has been shown superior to internal fixation(IF) the first year after injury. Long term results, however, are sparse. Methods. A total of 222 consecutive patients above 60 years, including mentally disabled, with IFNF were randomized to either internal fixation with two parallel screws or hemiarthroplasty, and operated by the surgeon on call. After 5 years, 68 of the 70 surviving patients accepted a follow-up visit. The reviewers were blinded for initial treatment. Results. The mean survival of the groups was similar. Only 12 (of 31) patients in the IF group still had their native hip joint at five years. Harris Hips score was 70.0 ± 3.5 and 70.4 ± 3.4 in the IF and hemiarthroplasty group, respectively (p=0.9). Eq5d index was in the IF group 0.56 ±0.08 and in the hemiarthroplasty group 0.45 ± 0.7 (p=0.3). Barthel ADL index was split into good function (score 95 or 100) and reduced function (score below 95). Of the patients in the internal fixation group, 42 % reported good function, corresponding number in the arthroplasty group was 52 % (p=0.4). After two years, there were 44 (42%) hips with a