Introduction. Patients with external fixators are at risk of pin site infection. A more objective assessment of possible pin site infection is warranted, particularly for future home-based monitoring of pin sites. The aim was to determine if
To detect early signs of infection infrared
Introduction and Objective. Digital infra-red
Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on thermal necrosis to the bone. A total of 16 New Zealand white rabbits weighing a mean of 2.90 kg (2.70 – 3.30 kg) were used. All rabbits were operated under general anaesthesia in a sterile operating room. Firstly, 4 cm longitudinal lateral approach was used to the right femur and then the femur was drilled with 1.0 mm trochar tip, spade tip and previously used unsharpened K-wires and 1.0 mm drill bit at 1450 rpm speed. Left femur was drilled with same three type K-wires and drill bit at 330 rpm speed. One cm distance was left among four penetrations on the femur. The thermal changes were recorded by Flir® E6 Thermal Camera from 50 cm distance and 30-degree angle. Thermographic measurements saved for every drilling process and recorded for the highest temperature (°C) during the drilling. All subjects were sacrificed post-operatively on the eighth day and specimens were prepared for the histological examination. The results of osteonecrosis assessment score and thermographic correlation were evaluated statistically. Histological specimens were evaluated by the scoring of osteonecrosis, osteoblastic activity, haemorrhage, microfracture and inflammation. Results were graded semi-quantitatively as none, moderate or severe for osteonecrosis, haemorrhage and inflammation. The microfracture and osteoblastic activity were evaluated as present or absent. There was no meaningful correlation between osteonecrosis and the drilling speed (p=0.108). There was less microfracture zone which was drilled with trochar tip K-wires at 1450 rpm speed (p=0.017). And the drilling temperature of trochar tip K-wires was higher than the others(p=0.001). Despite this evaluation, osteonecrosis zone of spade and unsharpened tip K-wires were more than trochar tip K-wires (p=0.039). The drill bit at 330 rpm caused the least osteonecrosis and haemorrhage and respectfully the lowest drilling temperature (p=0,001). The osteoblastic activity shows no difference between the groups. (p=0,122; 0,636;0.289) On the contrary to the literature, our experiment showed that there is no meaningful correlation between osteonecrosis score and temperature produced by drilling. The histological assessment showed the osteonecrosis during short drilling time but, not clarify the relation with drilling temperature. Eventually, the osteonecrosis showed a positive correlation with drilling time independently of drilling temperature at 330 rpm. (p=0,042) These results show that we need more studies to understand about osteonecrosis and its relationship with drilling heat temperature. Trochar tip K-wires creates higher drilling temperature but less osteonecrosis than a spade and unsharpened cut tip K-wires. Using unsharpened tip K-wire causes more osteonecrosis. Previously used and, unsharpened K-wires should be discarded
The December 2014 Hip &
Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection
Introduction. The concept and method of repeatedly connecting an extracorporeal blood pump to produce elevated pancycle inflow pressures to ischaemic limbs is presented. The aim of this study was to determine if intermittent increased perfusion would improve the clinical picture in peripheral arterial disease. Methods. Animal studies—to determine the safety and efficacy of the pumping and the access device were performed on 12 sheep. Following successful completion of that study, pilot studies of 18 patients were treated using the Peripheral Access Device (PAD) and Hypertensive Extracorporeal Limb Hyperperfusion (HELP). Treatment was offered to patients who had no other alternative than major amputation. Patients were treated for less than 100 hours of total pumping, broken over three or less treatment periods over approximately one week. Improvement was measured by pain scores, clinical examination and digital
We undertook a study of the anti-tumour effects of hyperthermia, delivered via magnetite cationic liposomes (MCLs), on local tumours and lung metastases in a mouse model of osteosarcoma. MCLs were injected into subcutaneous osteosarcomas (LM8) and subjected to an alternating magnetic field which induced a heating effect in MCLs. A control group of mice with tumours received MCLs but were not exposed to an AMF. A further group of mice with tumours were exposed to an AMF but had not been treated with MCLs. The distribution of MCLs and local and lung metastases was evaluated histologically. The weight and volume of local tumours and the number of lung metastases were determined. Expression of heat shock protein 70 was evaluated immunohistologically. Hyperthermia using MCLs effectively heated the targeted tumour to 45°C. The mean weight of the local tumour was significantly suppressed in the hyperthermia group (p = 0.013). The mice subjected to hyperthermia had significantly fewer lung metastases than the control mice (p = 0.005). Heat shock protein 70 was expressed in tumours treated with hyperthermia, but was not found in those tumours not exposed to hyperthermia. The results demonstrate a significant effect of hyperthermia on local tumours and reduces their potential to metastasise to the lung.
Background: The mechanism of tissue removal and residual tissue damage for ultrasonic ablation instruments have not been adequately investigated. In particular, the relationship between applied force and amplitude of distal tip displacement as determinants of cutting effect and residual tissue damage has not been clearly defined. Recent clinical studies have highlighted the potentially deleterious thermal and mechanical effect of ultrasonic energy in residual tissue. Aims: To evaluate the role of ultrasonic tissue resection as an alternative to mechanical shaver and electrosurgical resection for orthopaedic applications. We aim to investigate factors influencing material removal rate (MRR), cutting rate (CR) and thermal damage for meniscus tissue resection using an experimental 20kHz ultrasonic ablation device. Methods: An experimental force controlled testing rig was constructed using a 20kHz ultrasonic probe suspended vertically from a load cell. Ex-vivo bovine meniscus samples were harvested from knee joints and cut into uniform 16mm discs. Effect of variation in force (2.5–4.5N) and amplitude of distal tip displacement (242–494μm peak-peak) settings on material removal rate (MRR) and cutting (CR) was analyzed. Time-discrete temperature elevation in the meniscus was measured by embedded thermocouples and infrared
Whereas
Thermonecrosis either results in bone loss which may weaken the purchase of surgically-inserted screws leading to loosening or the dead bone may remain in situ and become infected resulting in a ring sequestrum. The aim of this project was to measure the heat generated during drilling of bone. By using a novel realtime thermal camera the thermal events could be visualised topographically. An experimental setup comprising a force table, an infrared camera, a power drill and a new surgical 2.5mm drill bit was constructed. This enabled measurements of the force applied and temperature changes in sheep cortical bone during a drilling operation. The temperature was observed throughout the drilling period and for further 15s after the drill bit was withdrawn. Images were grabbed using a LAND FTI Mv thermal camera which was driven by LIPS Mini software. Calibration was made in the range 20-200 degrees C, the upper value being provided by a high wattage resistor. Data was processed using routines written in MATLAB. It was found that 12s were required to drill through a single cortex. Within one second of drilling, the maximum recorded temperature in the vicinity of the drill increased from the baseline of 20 to 170 degrees C. It remained above this temperature for 25s. Immediately after the drill bit was withdrawn, a region of approximately 15mm of diameter of cortical surface had a sustained temperature above 50 degrees C. After 15s of cooling, this diameter had only reduced to 10mm. By modelling the cooling curve, the maximum temperature at the drill tip was extrapolated to be between 500-600 degrees C.
The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference ≥ 1.0°C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations.
Complex regional pain syndrome is characterised by an exaggerated response to injury in a limb with intense prolonged pain, vasomotor disturbance, delayed functional recovery and trophic changes. This review describes the current knowledge of the condition and outlines the methods of treatment available with particular emphasis on the knee.
Reflex sympathetic dystrophy is a syndrome characterised by pain and hyperaesthesia associated with swelling, vasomotor instability and dystrophic changes of the skin. It is rare in children, can occur without any previous history of significant trauma and may be recurrent and migratory. We reported 13 new cases of RSD in children and emphasised the role of a multidisciplinary team approach in management. A review of the literature was included. 13 children (3 boys and 10 girls) with reflex sympathetic dystrophy were presented. They were aged between 8 and 17 years. Mean age at onset was 13 years 4 months. All of them had RSD involving the lower limbs.
We performed a randomised controlled study to compare heparin with the A-V Impulse System in the prevention of deep-vein thrombosis (DVT) in 132 consecutive patients undergoing total hip replacement. After the operation, all patients had compression stockings, 65 were treated with calcium heparin and 67 with the intermittent plantar pump. DVT was diagnosed by Doppler ultrasound and
Pain in front of the knee is common in athletes and is often called patellofemoral arthralgia, but it is difficult to prove that the pain arises in that joint. Thermograms of 30 athletes clinically considered to have patellofemoral arthralgia were compared with those of a similar number of unaffected athletes matched for age and sex. A comparison was also made with thermograms of two older groups of 30 patients with knee involvement from either rheumatoid arthritis or osteoarthritis. Twenty-eight of the athletes with patellofemoral arthralgia had a diagnostic pattern on
The orthopaedic surgeon is often the first consultant to whom a patient with syringomyelia is referred. The disease is not as rare as he may suppose, but its early presenting features are very variable; if he relies solely on such familiar features as pes cavus and scoliosis, he may well miss the diagnosis. The commonest presenting symptom is pain in the head, neck, trunk or limbs; headache or neckache made worse by straining is particularly significant. A history of birth injury also may suggest the possibility of syringomyelia, especially if any spasticity subsequently worsens. Neurological features which may be diagnostic include nystagmus, dissociated sensory loss, muscle wasting, spasticity of the lower limbs or Charcot's joints. Radiographic features include erosion of the bodies of cervical vertebrae and widening of the spinal canal; if, at C5, the size of the canal exceeds that of the body by 6 millimetres in the adult, pathological dilatation is present. The presence of basilar invagination or other abnormalities of the foramen magnum, of spina bifida occulta and of scoliosis are further pointers.