Advertisement for orthosearch.org.uk
Results 1 - 20 of 1957
Results per page:
Bone & Joint Open
Vol. 5, Issue 12 | Pages 1092 - 1100
8 Dec 2024
Fraser E Spence S Farhan-Alanie OM Doonan J Mahendra A Gupta S

Aims

Limb salvage surgery (LSS) is the primary treatment option for primary bone malignancy. It involves the removal of bone and tissue, followed by reconstruction with endoprosthetic replacements (EPRs) to prevent amputation. Trabecular metal (TM) collars have been developed to encourage bone ingrowth (osseointegration (OI)) into EPRs. The primary aim of this study was to assess whether OI occurs when TM collars are used in EPRs for tumour.

Methods

A total of 124 patients from July 2010 to August 2021 who underwent an EPR for tumour under the West of Scotland orthopaedic oncology team were identified. Overall, 81 patients (65%) met the inclusion criteria, and two consultants independently analyzed radiographs at three and 12 months, as well as the last radiograph, using a modified version of the Stanford Radiological Assessment System.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 26 - 29
1 Dec 2024

The December 2024 Wrist & Hand Roundup360 looks at: Variability in thumb ulnar collateral ligament rupture management across the UK: survey insights; Identifying five distinct hand osteoarthritis pain phenotypes highlights the impact of biopsychosocial factors; Long-term outcomes of MAÏA TMC joint prosthesis for osteoarthritis: a possible alternative to trapeziectomy; Diagnostic and management strategies for malignant melanoma of the hand; Early versus delayed surgery for distal radius fractures: comparable outcomes but higher complications in delayed treatment; Perioperative anticoagulant and antiplatelet use does not increase complications in wide-awake hand surgery; Variability in treatment of metacarpal shaft fractures highlights need for standardized care; Low-intensity pulsed ultrasound ineffective in reducing time to union for scaphoid nonunion post-surgery.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 19 - 22
1 Dec 2024

The December 2024 Knee Roundup360 looks at: Unicompartmental knee arthroplasty and total knee arthroplasty in the same patient?; Lateral unicompartmental knee arthroplasty: is it a good option?; The fate of the unresurfaced patellae in contemporary total knee arthroplasty: early- to mid-term results; Tibial baseplate migration is not associated with change in PROMs and clinical scores after total knee arthroplasty; Unexpected positive intraoperative cultures in aseptic revision knee arthroplasty: what effect does this have?; Kinematic or mechanical alignment in total knee arthroplasty surgery?; Revision total knee arthroplasty achieves minimal clinically important difference faster than primary total knee arthroplasty; Outcomes after successful DAIR for periprosthetic joint infection in total knee arthroplasty.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 39 - 41
1 Dec 2024

The December 2024 Oncology Roundup. 360. looks at: Non-reversed great saphenous vein grafts for vascular reconstruction after resection of lower limb sarcoma; Detrimental effects of COVID-19 pandemic on patients with limb bone sarcoma: reference centre experience; Whole-body staging guidelines in sarcoma; Intraoperative marrow margin frozen section in limb bone sarcoma resection; Vacuum-assisted closure and paediatric oncological limb salvage; Treatment differences and long-term outcomes in adults and children with Ewing’s sarcoma; Survival, complications, and functional outcomes of uncemented distal femoral endoprosthesis with short, curved stem for patients with bone tumours


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1377 - 1384
1 Dec 2024
Fontalis A Yasen AT Giebaly DE Luo TD Magan A Haddad FS

Periprosthetic joint infection (PJI) represents a complex challenge in orthopaedic surgery associated with substantial morbidity and healthcare expenditures. The debridement, antibiotics, and implant retention (DAIR) protocol is a viable treatment, offering several advantages over exchange arthroplasty. With the evolution of treatment strategies, considerable efforts have been directed towards enhancing the efficacy of DAIR, including the development of a phased debridement protocol for acute PJI management. This article provides an in-depth analysis of DAIR, presenting the outcomes of single-stage, two-stage, and repeated DAIR procedures. It delves into the challenges faced, including patient heterogeneity, pathogen identification, variability in surgical techniques, and antibiotics selection. Moreover, critical factors that influence the decision-making process between single- and two-stage DAIR protocols are addressed, including team composition, timing of the intervention, antibiotic regimens, and both anatomical and implant-related considerations. By providing a comprehensive overview of DAIR protocols and their clinical implications, this annotation aims to elucidate the advancements, challenges, and potential future directions in the application of DAIR for PJI management. It is intended to equip clinicians with the insights required to effectively navigate the complexities of implementing DAIR strategies, thereby facilitating informed decision-making for optimizing patient outcomes.

Cite this article: Bone Joint J 2024;106-B(12):1377–1384.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1372 - 1376
1 Dec 2024
Kennedy JW Meek RMD

Hip fractures pose a major global health challenge, leading to high rates of morbidity and mortality, particularly among the elderly. With an ageing population, the incidence of these injuries is rising, exerting significant pressure on healthcare systems worldwide. Despite substantial research aimed at establishing best practice, several key areas remain the subject of ongoing debate. This article examines the latest evidence on the place of arthroplasty in the surgical treatment of hip fractures, with a particular focus on the choice of implant, the use of cemented versus uncemented fixation, and advances in perioperative care. Cite this article: Bone Joint J 2024;106-B(12):1372–1376


Bone & Joint 360
Vol. 13, Issue 6 | Pages 17 - 19
1 Dec 2024

The December 2024 Hip & Pelvis Roundup360 looks at: Total hip arthroplasty after femoral neck fractures versus osteoarthritis at one-year follow-up: a comparative, retrospective study; Excellent mid-term survival of a monoblock conical prosthesis in treating atypical and complex femoral anatomy with total hip arthroplasty; Hip arthroscopy for femoroacetabular impingement improves sexual function; Fast-track hip arthroplasty does not increase complication rates; Ten-year experience with same-day discharge outpatient total hip arthroplasty: patient demographics changed, but safe outcomes were maintained.


Bone & Joint Research
Vol. 13, Issue 10 | Pages 611 - 621
24 Oct 2024
Wan Q Han Q Liu Y Chen H Zhang A Zhao X Wang J

Aims

This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture.

Methods

Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 825 - 831
3 Oct 2024
Afghanyar Y Afghanyar B Loweg L Drees P Gercek E Dargel J Rehbein P Kutzner KP

Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up. Methods. This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up. Results. Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%. Conclusion. Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup. Cite this article: Bone Jt Open 2024;5(10):825–831


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries. Results. The carbon footprint of an uncemented THA was estimated at 100.02 kg CO2e, with a marginal increase to 104.89 kg CO2e for hybrid THA. Key contributors were consumables in the operating theatre (21%), waste generation (22%), and scope 2 emissions (38%). The study identified opportunities for reducing emissions, including instrument rationalization, transitioning to LED lighting, and improving waste-recycling practices. Conclusion. This study sheds light on the substantial carbon footprint associated with THA. Actionable strategies for reducing emissions were identified, emphasizing the need for sustainable practices in orthopaedic surgery. The findings prompt a critical discussion on the environmental impact of single-use versus reusable items in the operating theatre, challenging traditional norms to make more environmentally responsible choices. Cite this article: Bone Jt Open 2024;5(9):742–748


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively. Results. Overall, 21 patients (16%) encountered complications, and the rate of aseptic loosening was 7% (9/134). The survival rate up to 8.5 years was 93% for aseptic loosening as the endpoint, and 88% for any reason as the endpoint, retrospectively. Conclusion. The use of an uncemented distal femoral endoprosthesis with a short, curved stem demonstrated a low incidence of aseptic loosening and achieved long-term survivorship of up to nine years. Meanwhile, aseptic loosening typically occurs in the early stage postoperatively. Cite this article: Bone Joint J 2024;106-B(9):1000–1007


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 19 - 19
19 Aug 2024
Macheras G Kostakos T Tzefronis D
Full Access

Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of leg length discrepancy (LLD) was present, requiring shortening femoral osteotomy. 12 patients underwent sequential proximal femoral resection with trochanteric osteotomy, 46 subtrochanteric, 6 midshaft, and 25 distal femoral osteotomies with simultaneous valgus correction were performed. All acetabular prostheses were placed in the true anatomical position. We used uncemented high porosity cups. Patients were followed up for a minimum of 12 months. All osteotomies healed uneventfully except 3 non-unions of the greater trochanter in the proximal femur resection group. No femoral shaft fractures in proximally based osteotomies. No significant LLD compared to the unaffected or reconstructed side. 2 patients suffered 3 and 5 degrees malrotation of the femur in the oblique sub-trochanteric group. 3 patients suffered transient sciatic nerve palsies. Shortening femoral osteotomies in the treatment of DDH are necessary to avoid injury to the sciatic nerve. In our series, we found transverse subtrochanteric osteotomies to be the most technically efficient, versatile and predictable in their clinical outcome, due to the ability to correct rotation and preserve the metaphyseal bone integrity, allowing for better initial stem stability. Distal femoral osteotomies allowed for controllable correction of valgus knee deformity


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 63 - 63
19 Aug 2024
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A
Full Access

Vitamin E-doped cross-linked polyethylene (VEPE) has encouraged the use of larger heads in thinner liners in total hip arthroplasty (THA). However, there are concerns about wear and mechanical failure of the thin liner, especially when metal heads are used. The aim of this randomized controlled trial was to investigate if the use of a large metal head in a thin VEPE liner would increase polyethylene wear compared with a standard 32-mm metal head and to compare periacetabular radiolucencies and patient-reported outcomes in THA. 96 candidates for uncemented THA were randomly allocated to either the largest possible metal head (36–44 mm) that could be fitted in the thinnest available VEPE liner (intervention group) or a standard 32-mm metal head (control group). The primary outcome was proximal head penetration (PHP) measured with model-based radiostereometric analysis (RSA). Secondary outcomes were periacetabular radiolucencies and patient-reported outcomes. The mid-term results of the trial at 5 years are presented. Median total PHP (interquartile range) was -0.04 mm (−0.12 to 0.02) in the intervention group and -0.03 mm (=0.14 to 0.05) in the control group (p=0.691). The rates of periacetabular radiolucencies were 1/44 and 4/42 (p=0.197), respectively. Patient-reported hip function and health-related quality of life did not differ between the groups, but participants in the intervention group reported a higher level of activity (median UCLA rank 7 vs 6, p=0.020). There were 5 revisions caused by dislocations (2), periprosthetic fracture (1), stem subsidence (1), or iliopsoas impingement (1). Large metal heads in thin VEPE liners did not increase liner wear and were not associated with liner failure 5 years after THA


Securing the osteotomized greater trochanter (GT) during total hip arthroplasty (THA) for dislocated dysplastic hips (DDH) poses a significant challenge. This study evaluates the union rate and effectiveness of a 2-strand transverse wiring technique utilizing the lesser trochanter for wire anchorage and tensioning. A digastric anterior slide trochanteric osteotomy was performed in 106 patients (118 hips) undergoing THA for DDH. Following uncemented stem insertion, the GT was transferred and fixed to the lateral cortex of the proximal femur using monofilament stainless steel wires. In 72 out of 106 patients (80 hips), the GT was fixed with 2 transverse wire cerclages threaded through 2 drill holes in the base of the lesser trochanter, spaced vertically 5–10 millimeters apart. The wires were wrapped transversely over the GT and tightened, avoiding contact with its tendinous attachments. Patients were regularly monitored, and GT union was assessed clinically and radiographically. Patient ages ranged from 20 to 57 years (mean 35.5), with a follow-up period ranging from 1.5 to 12 years (mean 6.2). The mean union time was 3.3 months (range 2–7). Among all hips, two developed stable nonunion and single wire breakage, but no fragment displacement (2.5%). Two hips exhibited delayed union, eventually healing at 6 and 7 months after surgery. Reattachment of the greater trochanter utilizing a 2-strand transverse wire cerclage anchored at the base of the lesser trochanter demonstrated a high rate of union (97.5%) following THA in dislocated DDH cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 43 - 43
19 Aug 2024
Lustig S Batailler C
Full Access

The stem design in total hip arthroplasty (THA) is constantly evolving. The impact of the collar on the risk of periprosthetic fracture remains controversial. This study aimed to determine whether adding a collar to the femoral stem impacts the early periprosthetic fracture risk within 90 days of surgery. This retrospective study included 1,623 patients who underwent primary total hip arthroplasty in a single orthopedic department between January 2010 and December 2020. The inclusion criteria were uncemented stem with or without a collar, in a primary intention, without previous hip surgery with a similar “corail like” design. The assessed data were demographic characteristics (age, gender, number of obese (BMI > 30)), single or dual mobility, the surgical approach, the early complication, particularly the periprosthetic femoral fractures. Of the 1,623 patients, 1,380 received a collared stem (85%), and 243 received a collarless stem (15%). A multivariate analysis was performed to determine the collar's effect on the risk of early periprosthetic fracture (<90 days). Nine (0.55%) early periprosthetic fractures were identified in the whole cohort. There were four fractures (1.65%) in the collarless stem group and five fractures (0.36%) in the collared stem group (p=0,005). One patient required revision surgery in the collared stem group, while two patients required revision surgery in the collarless stem group. The multinomial logistic regression model indicated a statistically significant lower (p<0.05) risk of early periprosthetic fracture within 90 days of surgery in the collared stems group. No other risk factor for early periprosthetic fractures has been identified. Using collared stems in cementless THA protects early periprosthetic femoral fractures within 90 days of surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 24 - 24
19 Aug 2024
Dagneaux L Abdel MP Sierra RJ Lewallen DG Trousdale RT Berry DJ
Full Access

Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m. 2. , and 59% were female. An uncemented metaphyseal fixation stem was used in 30%, an uncemented diaphyseal fixation stem in 28%, an uncemented modular body stem with metaphyseal fixation sleeve in 24%, and a cemented stem in 18%. Simultaneous corrective femoral osteotomy was performed in 18%. Kaplan-Meier survivorships and Harris hip scores were reported. Mean follow-up was 8 years. The 10-year survivorships free of femoral loosening, aseptic femoral revision, any revision, and any reoperation were 95%, 93%, 90% and 88%, respectively. Revisions occurred in 13 hips for: aseptic femoral component loosening (3), stem fracture (2), dislocation (2), aseptic acetabular loosening (2), polyethylene liner exchange (2), and infection (2). Preoperative varus angular deformities were associated with a higher risk of any revision (HR 10, p=0.03), and simultaneous osteotomies with a higher risk of any reoperation (HR 3.6, p=0.02). Mean Harris hip scores improved from 52 preoperatively to 82 at 10 years (p<0.001). In the largest series to date of primary THAs in patients with angular proximal femoral deformities, we found a good 10-year survivorship free from any revision. Varus angular deformities, particularly those treated with a simultaneous osteotomy due to the magnitude or location of the deformity, had a higher reoperation rate. Keywords: Proximal femoral deformity; dysplasia; femoral osteotomy; survivorship; revision. Level of evidence: Level III, comparative retrospective cohort


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 42 - 42
19 Aug 2024
de Graeff JJ Kowalska J van der Pas SL van Leeuwen N Willigenburg NW Neve WC de Vries LMA Schreurs BW Nelissen RGHH van Steenbergen LN Poolman R
Full Access

Controversy persists over whether cemented or uncemented fixation is more effective in reducing revision and mortality risks following primary total hip arthroplasty (THA). Despite a shift towards uncemented THA in Europe, Australia, and the US, no consensus exists on superior outcomes. This ambiguity in evidence from randomized controlled trials (RCTs) and observational studies necessitates advanced research methodologies to derive more definitive conclusions. This study investigates the causal impact of THA fixation type on 2-year and 5-year revision rates, along with 90-day mortality, utilizing a regression discontinuity (RD) design in scenarios where fixation choice is guided by patient age. Employing data from the Dutch Arthroplasty Register, we conducted a cohort study on primary THAs for osteoarthritis from 2007 to 2019. A “fuzzy” RD design was executed to compute the Local Average Treatment Effect for subjects around the age-based selection threshold for fixation type. The main outcome of interest was the revision rate at 2 years post-operation. Analysis for the 2-year revision endpoint, covering any cause, included 2,344 females and 1,671 males across 5 hospitals each, with no significant variation in revision rates observed. For the 5-year mark, 1,058 females in 3 hospitals and 214 males in 1 hospital were examined, similarly showing no significant differences. Mortality within 90 days post-operation was also investigated in 5 female and 7 male cohorts, with 2,180 and 2,145 surgeries respectively, yielding no substantial disparities. In conclusion, the RD analysis revealed no notable differences in revision rates at 2 and 5 years or in early mortality based on the fixation method used in THA. These outcomes suggest that the age-based preference for THA fixation may not influence the revision or mortality risk, underscoring the value of RD design in deriving causal insights from observational data


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 47 - 47
19 Aug 2024
Dimitriou D Almazrua I Alhasson M Staunton P Zukor D Huk O Antoniou J
Full Access

Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to conventional stems. Recent literature suggested that stem length might be an independent risk factor for acute periprosthetic femoral fracture in direct anterior THA (1) or with different short stem designs (2). The purpose of the present study was to compare the incidence of acute periprosthetic femoral fractures, between stems of the same manufacture (Taperloc microplasty vs Taperloc complete), which have the same stem characteristics, except for the stem length which is 35 mm shorter in Taperloc microplasty during posterior and lateral THA. Our institution's arthroplasty database was searched for all primary total hip arthroplasties utilizing short femoral stems performed between August 2016 and August 2023. Pre-operative X-rays for each case were analysed to characterize the proximal femoral geometry, specifically the canal bone ratio (CBR) and canal flare index (CFI). Data analysis was performed to identify risk factors for periprosthetic fractures. For the time period assessed, 2107 femoral stems (Taperloc Microplasty:1727, Taperloc complete: 380) were implanted. Females constituted 53% of the cohort. The average patient age was 70±11 years. The periprosthetic fracture rate was 0.94%, with 20 periprosthetic fractures (Taperloc Microplasty:17, Taperloc complete: 3) excluding 2 greater trochanteric fractures (1 at each group), identified at follow-up of three months. There was no significant difference between the periprosthetic fracture rates between the two stems (0.98% vs 0.79%, p>0.72) The multivariate regression analysis demonstrated that the stem length, CBR, CFI, age, and gender were not risk factors for periprosthetic fracture. The present study demonstrated that both Taperloc Microplasty and Taperloc complete stems had similar rates of periprosthetic fractures, and the stem length was not a risk factor for a periprosthetic fracture during uncemented THA. 1. Tamaki T, Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2018 Mar;33(3):805-809. 2. Staunton P. Acute Periprosthetic Hip Fracture with Short Uncemented Femoral Stems. J Arthroplasty 2024 accepted


Bone & Joint 360
Vol. 13, Issue 4 | Pages 13 - 16
2 Aug 2024

The August 2024 Hip & Pelvis Roundup360 looks at: Understanding perceived leg length discrepancy post-total hip arthroplasty: the role of pelvic obliquity; Influence of femoral stem design on revision rates in total hip arthroplasty; Outcomes of arthroscopic labral treatment of femoroacetabular impingement in adolescents; Characteristics and quality of online searches for direct anterior versus posterior approach for total hip arthroplasty; Rapid return to braking after anterior and posterior approach total hip arthroplasty; How much protection does a collar provide?; Timing matters: reducing infection risk in total hip arthroplasty with corticosteroid injection intervals; Identifying pain recovery patterns in total hip arthroplasty using PROMIS data.