Advertisement for orthosearch.org.uk
Results 1 - 20 of 92
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1372 - 1376
1 Dec 2024
Kennedy JW Meek RMD

Hip fractures pose a major global health challenge, leading to high rates of morbidity and mortality, particularly among the elderly. With an ageing population, the incidence of these injuries is rising, exerting significant pressure on healthcare systems worldwide. Despite substantial research aimed at establishing best practice, several key areas remain the subject of ongoing debate. This article examines the latest evidence on the place of arthroplasty in the surgical treatment of hip fractures, with a particular focus on the choice of implant, the use of cemented versus uncemented fixation, and advances in perioperative care.

Cite this article: Bone Joint J 2024;106-B(12):1372–1376.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 656 - 661
1 Jul 2024
Bolbocean C Hattab Z O'Neill S Costa ML

Aims. Cemented hemiarthroplasty is an effective form of treatment for most patients with an intracapsular fracture of the hip. However, it remains unclear whether there are subgroups of patients who may benefit from the alternative operation of a modern uncemented hemiarthroplasty – the aim of this study was to investigate this issue. Knowledge about the heterogeneity of treatment effects is important for surgeons in order to target operations towards specific subgroups who would benefit the most. Methods. We used causal forest analysis to compare subgroup- and individual-level treatment effects between cemented and modern uncemented hemiarthroplasty in patients aged > 60 years with an intracapsular fracture of the hip, using data from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized clinical trial. EuroQol five-dimension index scores were used to measure health-related quality of life at one, four, and 12 months postoperatively. Results. Our analysis revealed a complex landscape of responses to the use of a cemented hemiarthroplasty in the 12 months after surgery. There was heterogeneity of effects with regard to baseline characteristics, including age, pre-injury health status, and lifestyle factors such as alcohol consumption. This heterogeneity was greater at the one-month mark than at subsequent follow-up timepoints, with particular regard to subgroups based on age. However, for all subgroups, the effect estimates for quality of life lay within the confidence intervals derived from the analysis of all patients. Conclusion. The use of a cemented hemiarthroplasty is expected to increase health-related quality of life compared with modern uncemented hemiarthroplasty for all subgroups of patients aged > 60 years with a displaced intracapsular fracture of the hip. Cite this article: Bone Joint J 2024;106-B(7):656–661


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


Aims

The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture.

Methods

This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 319 - 322
1 Apr 2024
Parsons N Whitehouse MR Costa ML


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup. 360. looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 5 - 5
24 Nov 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrück A Rupp M
Full Access

Aim. The aim of this investigation was to compare risk of infection in both cemented and cementless hemiarthroplasty (HA) as well as total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD) In HA and THA following femoral neck fracture fixation method was divided into cemented and cementless protheses and paired according to age, sex, body mass index (BMI), and the Elixhauser score using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, with 9,110 (66.9 %) HAs and 4502 (33.1 %) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared to cementless fixated prosthesis (p=0.013). In patients with THA no statistical difference between cemented and cementless prothesis was registered, however after one year 2.4 % of infections were detected in cementless and 2.1 % in cemented THA. In the subpopulation of HA after one year 1.9 % of infections were registered in cemented and 2.8 % in cementless HA. BMI (p=0.001) and Elixhauser-Comorbidity-Score (p<0.003) were identified as risk factors of PJI, while in THA also cemented prosthesis demonstrated within the first 30 days an increased risk (HR=2.728; p=0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was significantly reduced in patients treated by antibiotic-loaded cemented hemiarthroplasty. In particular for patients with multiple risk factors for the development of a PJI the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1196 - 1200
1 Nov 2023
Parker MJ Chatterjee R Onsa M Cawley S Gurusamy K

Aims

The aim of this study was to report the three-year follow-up for a series of 400 patients with a displaced intracapsular fracture of the hip, who were randomized to be treated with either a cemented polished tapered hemiarthroplasty or an uncemented hydroxyapatite-coated hemiarthroplasty.

Methods

The mean age of the patients was 85 years (58 to 102) and 273 (68%) were female. Follow-up was undertaken by a nurse who was blinded to the hemiarthroplasty that was used, at intervals for up to three years from surgery. The short-term follow-up of these patients at a mean of one year has previously been reported.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1070 - 1077
1 Oct 2023
Png ME Costa M Nickil A Achten J Peckham N Reed MR

Aims

To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults.

Methods

Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 13 - 16
1 Aug 2023

The August 2023 Hip & Pelvis Roundup360 looks at: Using machine learning to predict venous thromboembolism and major bleeding events following total joint arthroplasty; Antibiotic length in revision total hip arthroplasty; Preoperative colonization and worse outcomes; Short stem cemented total hip arthroplasty; What are the outcomes of one- versus two-stage revisions in the UK?; To cement or not to cement? The best approach in hemiarthroplasty; Similar re-revisions in cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty; Are hip precautions still needed?


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


Bone & Joint Research
Vol. 12, Issue 5 | Pages 331 - 338
16 May 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrueck A Rupp M

Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection. Cite this article: Bone Joint Res 2023;12(5):331–338


Bone & Joint Open
Vol. 4, Issue 3 | Pages 198 - 204
16 Mar 2023
Ramsay N Close JCT Harris IA Harvey LA

Aims

Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture.

Methods

This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 16 - 16
1 Dec 2022
Ibrahim M Abdelbary H Mah T
Full Access

Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. To date, there are no animal models that can fully recapitulate how a biofilm is challenged in vivo in the setting of GN-PJI. The purpose of this study is to establish a clinically representative GN-PJI in vivo model that can reliably depict biofilm formation on titanium implant surface. We hypothesized that the biofilm formation on the implant surface would affect the ability of the implant to be osseointegrated. The model was developed using a 3D-printed, medical-grade titanium (Ti-6Al-4V), monoblock, cementless hemiarthroplasty hip implant. This implant was used to replace the femoral head of a Sprague-Dawley rat using a posterior surgical approach. To induce PJI, two bioluminescent Pseudomonas aeruginosa (PA) strains were utilized: a reference strain (PA14-lux) and a mutant strain that is defective in biofilm formation (DflgK-lux). PJI development and biofilm formation was quantitatively assessed in vivo using the in vivo imaging system (IVIS), and in vitro using the viable colony count of the bacterial load on implant surface. Magnetic Resonance Imaging (MRI) was acquired to assess the involvement of periprosthetic tissue in vivo, and the field emission scanning electron microscopy (FE-SEM) of the explanted implants was used to visualize the biofilm formation at the bone-implant interface. The implant stability, as an outcome, was directly assessed by quantifying the osseointegration using microCT scans of the extracted femurs with retained implants in vitro, and indirectly assessed by identifying the gait pattern changes using DigiGaitTM system in vivo. A localized prosthetic infection was reliably established within the hip joint and was followed by IVIS in real-time. There was a quantitative and qualitative difference in the bacterial load and biofilm formation between PA14 and DflgK. This difference in the ability to persist in the model between the two strains was reflected on the gait pattern and implant osseointegration. We developed a novel uncemented hip hemiarthroplasty GN-PJI rat model. This model is clinically representative since animals can bear weight on the implant. PJI was detected by various modalities. In addition, biofilm formation correlated with implant function and stability. In conclusion, the proposed in vivo GN-PJI model will allow for more reliable testing of novel biofilm-targeting therapetics


Bone & Joint 360
Vol. 11, Issue 6 | Pages 37 - 40
1 Dec 2022

The December 2022 Trauma Roundup. 360. looks at: Anterior approach for acetabular fractures using anatomical plates; Masquelet–Ilizarov for the management of bone loss post debridement of infected tibial nonunion; Total hip arthroplasty – better results after low-energy displaced femoral neck fracture in young patients; Unreamed intramedullary nailing versus external fixation for the treatment of open tibial shaft fractures in Uganda: a randomized clinical trial; The Open-Fracture Patient Evaluation Nationwide (OPEN) study: the management of open fracture care in the UK; Cost-utility analysis of cemented hemiarthroplasty versus hydroxyapatite-coated uncemented hemiarthroplasty; Unstable ankle fractures: fibular nail fixation compared to open reduction and internal fixation; Long-term outcomes of randomized clinical trials: wrist and calcaneus; ‘HeFT’y follow-up of the UK Heel Fracture Trial


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 27 - 27
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 1 - 1
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1190 - 1190
1 Oct 2022
Png ME Petrou S Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin XL Costa ML


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims

Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes.

Methods

Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.