Aim: The aim of the study was to investigate the influence of bone density of the greater tuberosity on
Background: The stability of fracture fixation is influenced by the type of fixation, densitometric and geometric structure of the bone. DXA measures the integral mass of trabecular and cortical bone mineral but cannot discriminate between the structurally and mechanically separate constitutes. Distribution and organisation of bone mass (the geometric structure) has the final determination of the mechanical properties of bone. Pq CT scan is able to measure densitometric and geometric parameters of bone structure. However, there are no reports in the literature on the relationship between these measurements and the strength of fracture fixation. Our aim is to study the correlation between geometric and densitometric measurements of Pq CT scan, with the strength of fixation of bicondylar tibial plateau fractures and to assess the role of both trabecular and cancellous bone in that strength. Method: Eight Fresh frozen human cadaveric tibias were collected from subjects without a medical history of skeletal pathology. The proximal 10% of the tibia was scanned in a peripheral quantitative computer tomography scanner 1mm thick transverse slides, the cancellous and cortical bone mineral density of the proximal tibia were measured. The geometrical parameters: cortical area, trabecular area, bone strength index (BSI) and the Stress strain index (SSI) as non invasive indicators of the
Aim: Retears after rotator cuff surgery occur frequently and may compromise the functional results. Failure of bone anchors and sutures may influence the results to a great part. The goals of this in vitro investigation were to determine the
Antibiotic-laden bone cement is an important strategy of treatment for an established bone infection. It was aimed to find the safe antibiotic dose intervals of the antibiotic cements soaked in Phosphate Buffered Saline solution and to determine whether there was a difference in terms of
Osteoporosis accounts for a leading cause of degenerative skeletal disease in the elderly. Osteoblast dysfunction is a prominent feature of age-induced bone loss. While microRNAs regulate osteogenic cell behavior and bone mineral acquisition, however, their function to osteoblast senescence during age-mediated osteoporosis remains elusive. This study aims to utilize osteoblast-specific microRNA-29a (miR-29a) transgenic mice to characterize its role in bone cell aging and bone mass. Young (3 months old) and aged (9 months old) transgenic mice overexpressing miR-29a (miR-29aTg) driven by osteocalcin promoter and wild-type (WT) mice were bred for study. Bone mineral density, trabecular morphometry, and biomechanical properties were quantified using μCT imaging, material testing system and histomorphometry. Aged osteoblasts and senescence markers were probed using immunofluorescence, flow cytometry for apoptotic maker annexin V, and RT-PCR. Significantly decreased bone mineral density, sparse trabecular morphometry (trabecular volume, thickness, and number), and poor biomechanical properties (maximum force and breaking force) along with low miR-29a expression occurred in aged WT mice. Aging significantly upregulated the expression of senescence markers p16INK4a, p21Waf/Cip1, and p53 in osteoporotic bone in WT mice. Of note, the severity of bone mass and biomechanical strength loss, as well as bone cell senescence, was remarkably compromised in aged miR-29aTg mice. In vitro, knocking down miR-29a accelerated senescent (β-galactosidase activity and senescence markers) and apoptotic reactions (capsas3 activation and TUNEL staining), but reduced mineralized matrix accumulation in osteoblasts. Forced miR-29a expression attenuated inflammatory cytokine-induced aging process and retained osteogenic differentiation capacity. Mechanistically, miR-29a dragged osteoblast senescence through targeting 3′-untranslated region of anti-aging regulator FoxO3 to upregulate that of expression as evident from luciferase activity assessment. Low miR-29a signaling speeds up aging-induced osteoblast dysfunction and osteoporosis development. Gain of miR-29a function interrupts osteoblast senescence and shields bone tissue from age-induced osteoporosis. The robust analysis sheds light to the protective actions of miR-29a to skeletal metabolism and conveys a perspective of miR-29a signaling enhancement beneficial for aged skeletons.
We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and suture anchor fixation both failed at low tensile loads (about 140 N). The use of a 2 mm thick, plate-like augmentation device improved the failure strength to 329 N. The mechanical properties of many current repair techniques are poor and can be greatly improved by using good materials, an improved tendon-grasping suture, and augmentation at the bone attachment.
A population based finite element study that accounts for subject-specific morphology, density and load variations, suggests that osteoporosis does not markedly lower the mechanical compliance of the proximal femur to routine loads. Osteoporosis (OP) is a bone disease defined by low bone density and micro-architectural deterioration. This deterioration is neither uniform nor symmetric at the proximal femur. Evidence from analyses performed at the tissue level suggests that the cortical shell at the femoral neck is thinner in OP patients, especially in the superior regions, but not in the infero-anterior ones [Poole, Rubinacci]. Analogously, OP femurs show a higher anisotropy of the trabecular bone than controls [Ciarelli], suggesting a preservation of load bearing capacity in the principal loading direction vs. the transverse one. There is general consensus that the regions subjected to higher loads during walking, which is the predominant motor activity in the elderly, are mostly preserved. All these findings suggest that the OP femur should exhibit an almost normal mechanical competence during daily activities. This would be in accordance with the very low incidence of spontaneous fractures [Parker] and with the moderate fracture predictivity of BMD. Although reasonable, this hypothesis has never been tested at the organ level. Aim of the present study was to verify it with a population-based finite element (FE) study.Summary Statement
Introduction
Comparison of two cementing techniques: femoral component insertion into early-cure stage cement and insertion into late-cure stage cement in an in vivo model to identify if cement cure stage affects the strength of the bone cement interface. Bilateral arthroplasties – using only the femoral component - were performed in vivo on paired porcine femora. The femora were harvested and cross-sectioned in preparation for strength testing. Performance was measured by peak load required to push the femoral prosthesis and surrounding cement mantle free of the cancellous bone. The mean failure load for prostheses inserted into late cure stage cement was 908 N +/− SD 420, whereas the mean failure load for the conjugate early cure stage cement was 503 N +/− SD 342. A paired t-test indicated significantly higher load failure rates in the late cure stage cement versus the early cure stage samples (t=2.37, p<
0.049). Femoral component insertion into late cure stage cement required statistically significant higher loads for push-out when compared to femoral component insertion into early cure stage cement.
The use of fresh morsellised allograft in impaction bone grafting for revision hip surgery remains the gold standard. Bone marrow contains osteogenic progenitor cells that arise from multipotent mesenchymal stem cells and we propose that in combination with allograft will produce a living composite with biological and mechanical potential. This study aimed to determine if human bone marrow stromal cells (HBMSC) seeded onto highly washed morsellised allograft could survive the impaction process, differentiate and proliferate along the osteogenic lineage and confer biomechanical advantage in comparison to impacted allograft alone. Future work into the development of a bioreactor is planned for the potential safe translation of such a technique into clinical practice.
Total leg muscle function in hip OA patients is not well studied. We used a test-retest protocol to evaluate the reproducibility of single- and multi-joint peak muscle torque and rapid torque development in a group of 40–65 yr old hip patients. Both peak torque and torque development are outcome measures associated with functional performance during activities of daily living. Patients: Twenty patients (age 55.5±3.3, BMI 27.6±4.8) who underwent total hip arthroplasty participated in this study. Reliability: We used the intra-class correlation (ICC) and within subject coefficients of variation (CVws) to evaluate reliability. Agreement: Relative Bland-Altman 95% limits of agreements (LOA) and smallest detectable difference (SDD) were calculated and used for evaluation of measurement accuracy. Parameters: Maximal muscle strength (peak torque, Nm) and rate of torque development (Nm•sec-1) for affected (AF) and non-affected (NA) side were measured during unilateral knee extension-flexion (seated), hip extension-flexion, and hip adduction-abduction (standing), respectively. Contractile RTD100, 200, peak was derived as the average slope of the torque-time curve (torque/time) at 0–100, 0–200 and 0 peak relative to onset of contraction. Protocol: After 5 min level walking at self-selected and maximum speeds each muscle group was tested using 1–2 sub-maximal contraction efforts followed by 3 maximal contractions 4s duration. Statistics: The variance components were estimated using STATA12, with muscle function and occasion as independent variable and patients as random factor, using the restricted maximum likelihood method (=0.05).Introduction
Material and Methods
Aims. Orthopaedic surgery requires grafts with sufficient
Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior
To address the current challenge of anterior cruciate ligament (ACL) reconstruction, this study is the first to fabricate a braided collagen rope (BCR) which mimics native hamstring for ACL reconstruction. The study aims to evaluate the biological and biomechanical properties of BCR both in vivo and vitro. Rabbit ACL reconstruction model using collagen rope and autograft (hamstring tendon) was conducted. The histological and biomechanical evaluations were conducted at 6-, 12-, 18, 26-week post-operation. In vitro study included cell morphology analysis, cell function evaluation and RNA sequencing of the tenocytes cultured on BCR. A cadaver study was also conducted to verify the feasibility of BCR for ACL reconstruction. BCR displays satisfactory
Aims. To develop an early implant instability murine model and explore the use of intermittent parathyroid hormone (iPTH) treatment for initially unstable implants. Methods. 3D-printed titanium implants were inserted into an oversized drill-hole in the tibiae of C57Bl/6 mice (n = 54). After implantation, the mice were randomly divided into three treatment groups (phosphate buffered saline (PBS)-control, iPTH, and delayed iPTH). Radiological analysis, micro-CT (µCT), and biomechanical pull-out testing were performed to assess implant loosening, bone formation, and osseointegration. Peri-implant tissue formation and cellular composition were evaluated by histology. Results. iPTH reduced radiological signs of loosening and led to an increase in peri-implant bone formation over the course of four weeks (timepoints: one week, two weeks, and four weeks). Observational histological analysis shows that iPTH prohibits the progression of fibrosis. Delaying iPTH treatment until after onset of peri-implant fibrosis still resulted in enhanced osseointegration and implant stability. Despite initial instability, iPTH increased the mean pull-out strength of the implant from 8.41 N (SD 8.15) in the PBS-control group to 21.49 N (SD 10.45) and 23.68 N (SD 8.99) in the immediate and delayed iPTH groups, respectively. Immediate and delayed iPTH increased mean peri-implant bone volume fraction (BV/TV) to 0.46 (SD 0.07) and 0.34 (SD 0.10), respectively, compared to PBS-control mean BV/TV of 0.23 (SD 0.03) (PBS-control vs immediate iPTH, p < 0.001; PBS-control vs delayed iPTH, p = 0.048; immediate iPTH vs delayed iPTH, p = 0.111). Conclusion. iPTH treatment mediated successful osseointegration and increased bone
A spine compression fracture is a very common form of fracture in elderly with osteoporosis. Injection of polymethyl methacrylate (PMMA) to fracture sites is a minimally invasive surgical treatment, but PMMA has considerable clinical risks. We develop a novel type thermoplastic injectable bone substitute contains the proprietary composites of synthetic ceramic bone substitute and absorbable thermoplastic polymer. We used thermoplastic biocompatible polymers Polycaproactone (PCL) to encapsulate calcium-based bone substitutes hydroxyapatite (Ca10(PO4)6(OH)2, HA) and tricalcium phosphate (TCP) to form a biodegradable injectable bone composite material. The space occupation ration PCL:HA/TCP is 1:9. After heating process, it can be injected to fracture site by specific instrument and then self-setting to immediate reinforce the vertebral body. The thermoplastic injection bone substitute can obtain good injection properties after being heated by a heater at 90˚C for three minutes, and has good anti-washout property when injected into normal saline at 37˚C. After three minutes, solidification is achieved. Mechanical properties were assessed using the material compression test system and the mechanical support close to the vertebral spongy bone. In vitro cytotoxicity MTT assay (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) was performed and no cell cytotoxicity was observed. In vivo study with three New Zealand rabbits was performed, well bone growth into bone substitute was observed and can maintain good mechanical support after three months implantation. The novel type thermoplastic injection bone substitute can achieve (a) adequate injectability and viscosity without the risk of cement leakage; (b) adequate
In 2021 the bone grafting market was worth €2.72 billion globally. As allograft bone has a limited supply and risk of disease transmission, the demand for synthetic grafting substitutes (BGS) continues to grow while allograft bone grafts steadily decrease. Synthetic BGS are low in
Residual tumor cells left in the bone defect after malignant bone tumor resection can result in local tumor recurrence and high mortality. Therefore, ideal bone filling materials should not only aid bone reconstruction or regeneration, but also exert local chemotherapeutic efficacy. However, common bone substitutes used in clinics are barely studied in research for local delivery of chemotherapeutic drugs. Here, we aimed to use facile manufacturing methods to render polymethylmethacrylate (PMMA) cement and ceramic granules suitable for local delivery of cisplatin to limit bone tumor recurrence. Porosity was introduced into PMMA cement by adding 1-4% carboxymethylcellulose (CMC) containing cisplatin, and chemotherapeutic activity was rendered to two types of granules via adsorption. Then, mechanical properties, porosity, morphology, drug release kinetics, ex vivo reconstructive properties of porous PMMA and in vitro anti-cancer efficacy against osteosarcoma cells were assessed. Morphologies, molecular structures, drug release profiles and in vitro cytostatic effects of two different drug-loaded granules on the proliferation of metastatic bone tumor cells were investigated. The
We developed a novel silorane-based biomaterial (SBB) for use as an orthopedic cement. SBB is comprised of non-toxic silicon-based monomers, undergoes non-exothermic polymerization, and has weight-bearing strength required of orthopedic cements. We sought to compare the antibiotic release kinetics of this new cement to that of commercially available PMMA bone cement. We also evaluated each material's inherent propensity to support the attachment of bacteria under both static and dynamic conditions. One gram of either rifampin or vancomycin was added to 40g batches of PMMA and SBB. Pellets were individually soaked in PBS. Eluate was collected and tested daily for 14 days using HPLC. Compressive strength and modulus were tested over 21 days. Bioassays were used to confirm the bioactivity of the antibiotics eluted. We measured the growth and maturation of staphylococcus aureus (SA) biofilm on the surface of both PMMA and SBB disks over the course of 72 hours in a static well plate and in a dynamic biofilm reactor (CDC Biofilm Reactor). N=4 at 24, 48, and 72 hours. A luminescent strain of SA (Xen 29) was employed allowing imaging of bacteria on the discs. SBB eluted higher concentrations of vancomycin than did PMMA over the course of 14 days (p<0.001). A significant 55.1% greater day 1 elution was observed from SBB. Silorane cement was able to deliver rifampin in clinically favorable concentrations over 14 days. On the contrary, PMMA was unable to deliver rifampin past day 1. The incorporation of rifampin into PMMA severely reduced its
Aim. Prosthetic joint infections pose a major clinical challenge. Developing novel material surface technologies for orthopedic implants that prevent bacterial adhesion and biofilm formation is essential. Antimicrobial coatings applicable to articulating implant surfaces are limited, due to the articulation mechanics inducing wear, coating degradation, and toxic particle release. Noble metals are known for their antimicrobial activity and high
Varus malalignment increases the susceptibility of cartilage to mechanical overloading, which stimulates catabolic metabolism to break down the extracellular matrix and lead to osteoarthritis (OA). The altered mechanical axis from the hip, knee to ankle leads to knee joint pain and ensuing cartilage wear and deterioration, which impact millions of the aged population. Stabilization of the remaining damaged cartilage, and prevention of further deterioration, could provide immense clinical utility and prolong joint function. Our previous work showed that high tibial osteotomy (HTO) could shift the mechanical stress from an imbalanced status to a neutral alignment. However, the underlying mechanisms of endogenous cartilage stabilization after HTO remain unclear. We hypothesize that cartilage-resident mesenchymal stem cells (MSCs) dampen damaged cartilage injury and promote endogenous repair in a varus malaligned knee. The goal of this study is to further examine whether HTO-mediated off-loading would affect human cartilage-resident MSCs' anabolic and catabolic metabolism. This study was approved by IACUC at Xi'an Jiaotong University. Patients with medial compartment OA (52.75±6.85 yrs, left knee 18, right knee 20) underwent open-wedge HTO by the same surgeons at one single academic sports medicine center. Clinical data was documented by the Epic HIS between the dates of April 2019 and April 2022 and radiographic images were collected with a minimum of 12 months of follow-up. Medial compartment OA with/without medial meniscus injury patients with unilateral Kellgren /Lawrence grade 3–4 was confirmed by X-ray. All incisions of the lower extremity healed well after the HTO operation without incision infection. Joint space width (JSW) was measured by uploading to ImageJ software. The Knee injury and Osteoarthritis Outcome Score (KOOS) toolkit was applied to assess the pain level. Outerbridge scores were obtained from a second-look arthroscopic examination. RNA was extracted to quantify catabolic targets and pro-inflammatory genes (QiaGen). Student's t test for two group comparisons and ANOVA analysis for differences between more than 2 groups were utilized. To understand the role of mechanical loading-induced cartilage repair, we measured the serial changes of joint space width (JSW) after HTO for assessing the state of the cartilage stabilization. Our data showed that HTO increased the JSW, decreased the VAS score and improved the KOOS score significantly. We further scored cartilage lesion severity using the Outerbridge classification under a second-look arthroscopic examination while removing the HTO plate. It showed the cartilage lesion area decreased significantly, the full thickness of cartilage increased and
Objectives. The objective of this study was to characterize the effect of rifampin incorporation into poly(methyl methacrylate) (PMMA) bone cement. While incompatibilities between the two materials have been previously noted, we sought to identify and quantify the cause of rifampin’s effects, including alterations in curing properties,
Anterior cruciate ligament (ACL) reconstruction is the current standard of care for ACL tears. However, the results are not consistently successful, autografts or allografts have certain disadvantages, and synthetic grafts have had poor clinical results. The aim of this study was to determine the efficacy of tissue engineering decellularized tibialis tendons by recellularization and culture in a dynamic tissue bioreactor. To determine if recellularization of decellularized tendons combined with mechanical stimulation in a bioreactor could replicate the mechanical properties of the native ACL and be successfully used for ACL reconstruction in vivo. Porcine tibialis tendons were decellularized and then recellularized with human adult bone marrow-derived stem cells. Tendons were cultured in a tissue bioreactor that provided biaxial cyclic loading for up to 7 days. To reproduce mechanical stresses similar to hose experienced by the ACL within the knee joint, the tendons were subjected to simultaneous tension and torsion in the bioreactor. Expression of tendon-specific genes, and newly synthesized collagen and glycosaminoglycan (GAG) were used to quantify the efficacy of recellularization and dynamic bioreactor culture. The
Background. Tigecycline, the first member of glycylcycline family, has effective antimicrobial activity against resistant and implant associated infectious organisms. The objectives of this study are to assess the compressive and tensile
Objective: The purpose of the present study was to assess whether clinicians are actually able to evaluate the mechanical status of lengthening callus from plain radiographs. Materials and Methods: 36 rats were employed in this study. Their left femurs were lengthened by 6 mm as a bone lengthening model. Rats were euthanized at 4 8 12 and 16 weeks after lengthening. Both femora were X-rayed and then bone density parameters (bone mineral content, bone mineral density and bone area) of lengthening callus were measured using pQCT. Three-point bending test was performed to determine the
Current strategy for orthopedic tissue engineering mainly focusses on the regeneration of the damaged tissue using cell-seeded three-dimensional scaffolds. Biocompatible scaffolds with controllable degradation and suitable mechanical property are required to support new tissue in-growth and regeneration . [1]. Porous composite scaffolds made from organic and inorganic materials are highly preferred, which can mimic the natural bone in their composition as well can enhance tissue repair . [2]. Scaffolds with optimum
Objectives. The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing
Introduction: Since Albright first proposed the concept of diabetic osteopenia, many studies have investigated the levels of mineral bone density (BMD) and risk of osteoporosis. In this study we investigate the effect of exercise, alfacalcidol and parathyroid hormone (1–34) on bone marker, BMD and bone mechanical properties in spontaneously diabetic GK/Jcl rats. Methods: 18 week-old male GK/Jcl rats were divided into 4 groups; no treatment (NT), exercise (Ex), alfacalcidol (ALF), and parathyroid hormone (PTH). The bone mineral density (BMD) of the lumbar vertebrae (L2-L4) and the left femur was measured by dual energy X-ray absorptiometry (DXA). Serum calcium (Ca), inorganic phosphorus (Pi) and osteocalcin (OC) were measured. Urinary Ca, Po, and creatinine (Cre) were measured. Urinary deoxypyridinoline (D-Pyr) was measured and the data were corrected for urinary Cre concentration.
As compared to magnesium (Mg) and iron (Fe), solid zinc (Zn)-based absorbable implants show better degradation rates. An ideal bone substitute should provide sufficient mechanical support, but pure Zn itself is not strong enough for load-bearing medical applications. Modern processing techniques, like additive manufacturing (AM), can improve
Background. Antibiotic-loaded cement has been used over decades as a local antibiotic delivery for the treatment of bone and joint infections. However, there were some disadvantages such as unpredictable elution, insufficient local concentration and reduced
After anterior cruciate ligament (ACL) rupture, reconstructive surgery with a hamstring tendon autograft is often performed. Despite overall good results, ACL re-rupture occurs in up to 10% of the patient population, increasing to 30% of the cases for patients aged under 20 years. This can be related to tissue remodelling in the first months to years after surgery, which compromises the graft's
Aims. To determine whether half-threaded screw holes in a new titanium locking plate design can substantially decrease the notch effects of the threads and increase the plate fatigue life. Methods. Three types (I to III) of titanium locking plates were fabricated to simulate plates used in the femur, tibia, and forearm. Two copies of each were fabricated using full- and half-threaded screw holes (called A and B, respectively). The
Treatment of tendon and ligament injuries remains challenging; the aim is to find a biocompatible substance with mechanical and structural properties that replicate those of normal tendon and ligament. We examined the mechanical properties of Demineralised Cortical Bone (DCB) after gamma irradiation (GI) and freeze drying (FD). We also used different techniques for repairing bone-tendon-bone with DCB in order to measure the mechanical performance of the construct. DCB specimens were allocated into 4 groups; FD, GI, combination of both or none. The maximum tensile forces and stresses were measured. 4 cadaveric models of repair of 1cm patellar tendon defect using DCB were designed; model-1 using one bone anchor, Model-2 using 2 bone anchors, Model-3 off-loading by continuous thread looped twice through bony tunnels, Model-4 off-loading with 3 hand braided threads. Force to failure and mode were recorded for each sample. FD groups results were statistically higher (p=<0.05) compared to non-FD groups, while there was no statistical difference between GI and non-GI groups. The median failure force for model-1: 250N, model-2: 290N, model-3: 767N and model-4: 934N. There was no statistical significance between model-1 and model-2 (p=0.249), however statistical significance was found between other models (p=<0.006). GI has no significant effect on
Introduction: Impaction allografting allows an initial stable function of revision hip replacements and a method of reconstituting the bone stock. A previous in-vivo ovine study has found that the density of impacted morsellised allograft reduces after six weeks but recovers by twelve weeks. This reduction in density during remodelling may also correspond with a reduced
Background. External fixation is a method of osteosynthesis currently required in traumatology and orthopaedic surgery. Pin tract infection is a common problem in clinical practice. Infection occurs after a bacterial colonisation of the pin due to its contact with skin and local environment. To prevent such local contamination, one way to handle this issue is to create a specific coating using method which could be applied in the medical field. In this work we develop a surface coating for external fixator pins based on photocatalytic TiOα properties, producing a bactericidal effect with sufficient
Summary Statement. We evaluated the
We studied the calcium content and
Introduction The AO/ASIF 3.5 mm STS is increasingly used for internal fixation of large bones with the recent introduction of the 3.5 mm periarticular plating system. Our study aims to compare the insertion torque and mechanical properties of the screw after insertion into bovine femora using non tapped and pretapped methods. Methods Three groups of ten 3.5 mm AO/ASIF STSs of variable lengths were used. One group was put aside as the control. One group was inserted into fresh bovine femora using pre-tapped drill holes and the final group using non-tapped drill holes. The insetion torques were measured and compared using an analogue torque screw driver. All screws were removed. The three groups were then tested for
Adult articular cartilage mechanical functionality is dependent on the unique zonal organization of its tissue. Current mesenchymal stem cell (MSC)-based treatment has resulted in sub-optimal cartilage repair, with inferior quality of cartilage generated from MSCs in terms of the biochemical content, zonal architecture and
Patellar fractures account for approximately 1% of all fractures. Open reduction and internal fixation is recommended to restore extensor continuity and articular congruity. However, complications such as nonunion and symptomatic hardware, still exist. Furthermore, there is a risk of re-fracturing of the healed bone during the removal of the implants. Magnesium (Mg), a biodegradable metal, has elastic moduli and compressive yield strength that are comparable to those of natural bone. Our previous study showed that released Mg ions enhanced fracture healing. However, Mg-based implants degrade rapidly after implantation and lead to insufficient
Objectives. Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the
Summary Statement. This study describes the design and preliminary in vitro testing of a novel patch for the repair of rotator cuff tendon tears. The laminated design incorporates woven and electrospun components. The woven element provides the patch with excellent
Biometals like Magnesium (Mg) and Zinc (Zn) are essential for life. Mg/Zn-deficiency has been linked to numerous diseases including cardiovascular, bone, diabetics, neurological and neurodegenerative disorders. Moreover, Mg/Zn-based biomaterials have recently emerged as innovative degradable medical implants, typically for cardiovascular and orthopedic application. We study the pathophysiological role of Mg. 2+. /Zn. 2+. ion in vascular and bone diseases, as well as metallic Mg/Zn alloys for stent and bone implant applications. We demonstrated some interesting role and mechanism of Mg. 2+. /Zn. 2+. ion in controlling cellular functions. Also, metallic Mg/Zn-based medical implants exhibited strong potential as stent and bone fixation device. They have sufficient
Introduction. Total Elbow Arthroplasty (TEA) is recognized as an effective treatment solution for patients with rheumatoid arthritis or for traumatic conditions. Current total elbow devices can be divided into linked or unlinked design. The first design usually presents a linking element (i.e. an axle) to link together the ulnar and humeral components to stabilize the joint; the second one does not present any linkage and the stability is provided by both intrinsic design constraints and the soft tissues. Convertible modular solutions allow for an intraoperative decision to link or unlink the prosthesis; the modular connections introduce however additional risks in terms of both
In order to evaluate the feasibility of zinc alloys as future biodegradable bone implant materials, the mechanical properties, corrosion resistance, hemocompatibility, cell activity, proliferation and adhesion, in vivo animal implantation experiments have been employed. The experimental results show that the alloying element magnesium, calcium and strontium can significantly improve the mechanical properties of pure zinc, and further deformation processes can further improve the mechanical properties of zinc alloys. Alloying elements can effectively control the corrosion rates of zinc alloys, which are between the rates of magnesium alloys and iron alloys. Zinc and zinc alloys exhibit excellent hemocompatibility and the hemolysis rate is far lower than 5%. After adding alloying elements Mg, Ca and Sr, MG63 and ECV304 cell proliferation rate and activity increased significantly, while for VSMC cell, the influence of alloying elements effect is not obvious. Zinc alloy intramedullary pins can effectively promote the new bone formation, and after 2 months implanted in mice femur, they still maintained a relatively complete structure, indicating that they are able to provide enough
Biomechanical analysis is important to evaluate the effect of orthopaedic surgeries. CT-image based finite element method (CT-FEM) is one of the most important techniques in the computational biomechanics field. We have been applied CT-FEM to evaluate resorptive bone remodeling, secondary to stress shielding, after total hip arthroplasty (THA). We compared the equivalent stress and strain energy density to postoperative BMD (bone mineral density) change in the femur after THA, and a significant correlation was observed between the rate of changes in BMD after THA and equivalent stress. For periacetabular osteotomy cases, we investigated mechanical stress in the hip joint before and after surgery. Mechanical stress in the hip joint decreased significantly after osteotomy and correlated with the degree of the acetabular coverage. For arthroscopic osteochondroplasty cases, we examined
Collagen is a key component of the extracellular matrix in a variety of tissues and hence is widely used in tissue engineering research, yet collagen has had limited uptake in the field of 3D printing. In this study we successfully adapted an existing electronic printing method, aerosol jet printing (AJP), to print high resolution 3D constructs of recombinant collagen type III (RHCIII). Circular samples with a diameter of 4.5mm and 288 layers thick, or a diameter of 6.5mm and 400 layers thick were printed on glass cover slips with print lines of 60µm. Attenuated Total Reflectance Fourier-Transorm Infa-red (ATR-FTIR) spectroscopy performed on the 4 of the printed samples and dried non-printed RHCIII samples showed that no denaturation had occurred due to the printing process. Printed samples were crosslinked using EDC [N-(3-Dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride, Sigma Aldrich] to improve their stability and
The effect of bisphosphonates on the mechanical properties of the uninjured contra-lateral cortical bone during fracture healing is poorly reported. There remains conflicting evidence with regards the effect of bisphosphonate therapy on cortical bone strength. We assessed the effect of nine weeks of Ibandronate therapy, in a dose known to preserve cancellous bone BMD and strength, on the mechanical properties of the uninjured rat tibial diaphyses using a standardised model of tibial osteotomy and plate fixation. Skeletally mature ex-breeder rats were used. Stress at failure of the tibial diaphyses was measured by a four-point bending test using a custom made jig for rat tibiae. The
Scaffold-based bone tissue engineering holds great promise for the future of osseous defects therapies. Prepare the suitable scaffold properties are physiochemical modifications in terms of porosity,
Balloon kyphoplasty (BKP) is a minimally invasive surgical technique used to correct kyphosis and vertebral compression fractures. BKP uses cement to fill a void created by the inflation of a balloon in a vertebra, it can be used as an alternative to vertebroplasty to reduce cement extravasation. Issues such as poor inter digitisation of the cement and the trabecular bone can arise with the BKP method. This can be due to a compacted layer created during the procedure which can cause complications post-surgery. The primary aim of this study was to investigate alternative cement application methods which could improve the