Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1662 - 1666
1 Dec 2013
Parker L Garlick N McCarthy I Grechenig S Grechenig W Smitham P

The AO Foundation advocates the use of partially threaded lag screws in the fixation of fractures of the medial malleolus. However, their threads often bypass the radiodense physeal scar of the distal tibia, possibly failing to obtain more secure purchase and better compression of the fracture. We therefore hypothesised that the partially threaded screws commonly used to fix a medial malleolar fracture often provide suboptimal compression as a result of bypassing the physeal scar, and proposed that better compression of the fracture may be achieved with shorter partially threaded screws or fully threaded screws whose threads engage the physeal scar. We analysed compression at the fracture site in human cadaver medial malleoli treated with either 30 mm or 45 mm long partially threaded screws or 45 mm fully threaded screws. The median compression at the fracture site achieved with 30 mm partially threaded screws (0.95 kg/cm. 2. (interquartile range (IQR) 0.8 to 1.2) and 45 mm fully threaded screws (1.0 kg/cm. 2 . (IQR 0.7 to 2.8)) was significantly higher than that achieved with 45 mm partially threaded screws (0.6 kg/cm. 2. (IQR 0.2 to 0.9)) (p = 0.04 and p < 0.001, respectively). The fully threaded screws and the 30mm partially threaded screws were seen to engage the physeal scar under an image intensifier in each case. The results support the use of 30 mm partially threaded or 45 mm fully threaded screws that engage the physeal scar rather than longer partially threaded screws that do not. A 45 mm fully threaded screw may in practice offer additional benefit over 30 mm partially threaded screws in increasing the thread count in the denser paraphyseal region. Cite this article: Bone Joint J 2013;95-B:1662–6


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 113 - 116
1 Jan 1999
Rowan R Davey KJ

We describe a surgical technique for ankle arthrodesis using an anterior approach to the ankle and internal fixation with an anteriorly-placed AO T plate. A total of 33 patients who had ankle arthrodeses have been followed retrospectively. Thirty-one (94%) of the ankles fused although two patients developed tibial stress fractures. Four patients had a superficial infection which did not prevent union. The surgical technique is simple, easily reproducible and gives excellent clinical results with a high rate of union


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 2 - 2
17 Jun 2024
Fishley W Morrison R Baldock T Hilley A Baker P Townshend D
Full Access

Background. In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods. Method. The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1. st. January 2019 and 31. st. December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery. Results. 1448 ankle fractures which involved fixation of the fibula were recorded; one-third tubular plate was used in 866 (59.8%) cases, a locking plate in 463 (32.0%) cases and other methods in 119 (8.2%) cases. There was significant difference between centres (p<0.001) in implant type used. Other factors associated with implant type were age, diabetes, osteoporosis, open fractures, fracture pattern and the presence of comminution. Incidence of lateral wound breakdown was higher in locking plates than one-third tubular plates (p<0.05). There was no significant difference in infection, non-union, fixation failure or removal of metalware. Conclusion. There is significant variation in practice in the UK in implant use for fixation of the fibula in ankle fractures. Potentially unnecessary use of locking plates, where a one-third tubular shows equivalent outcomes, incurs additional cost and may increase the risk of lateral wound breakdown. We would encourage surgeons with high locking plate usage to evaluate their own unit's practice against this data


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 7 - 7
10 Jun 2024
Hill D Davis J
Full Access

Introduction. Tibial Pilon fractures are potentially limb threatening, yet standards of care are lacking from BOFAS and the BOA. The mantra of “span, scan, plan” describes staged management with external fixation to allow soft tissue resuscitation, followed by a planning CT-scan. Our aim was to evaluate how Tibial Pilon fractures are acutely managed. Methods. ENFORCE was a multi-centre retrospective observational study of the acute management of partial and complete articular Tibial Pilon fractures over a three-year period. Mechanism, imaging, fracture classification, time to fracture reduction and cast, and soft tissue damage control details were determined. Results. 656 patients (670 fractures) across 27 centres were reported. AO fracture classifications were: partial articular (n=294) and complete articular (n=376). Initial diagnostic imaging mobilities were: plain radiographs (n=602) and CT-scan (n=54), with all but 38 cases having a planning CT-scan. 526 fractures had a cast applied in the Emergency Department (91 before radiological diagnosis), with the times taken to obtain post cast imaging being: mean 2.7 hours, median 2.3 hours, range 28 mins – 14 hours). 35% (102/294) of partial articular and 57% (216/376) of complete articular (length unstable) fractures had an external fixator applied, all of which underwent a planning CT-scan. Definitive management consisted of: open reduction internal fixation (n=495), fine wire frame (n=86), spanning external fixator (n=25), intramedullary nail (n=25), other (n=18). Conclusion. The management of Tibial Pilon fractures is variable, with prolonged delays in obtaining post cast reduction radiographs, and just over half of length unstable complete articular fractures being managed with the gold standard “span, scan, plan” staged soft tissue resuscitation. A BOFAS endorsed BOAST (British Orthopaedic Association Standard for Trauma) for Tibial Pilon fractures is suggested for standardisation of the acute management of these potentially limb threatening injuries, together with setting them apart from more straightforward ankle fractures


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 945 - 949
1 Jul 2015
Droog R Verhage SM Hoogendoorn JM

In this retrospective cohort study, we analysed the incidence and functional outcome of a distal tibiofibular synostosis. Patients with an isolated AO type 44-B or C fracture of the ankle who underwent surgical treatment between 1995 and 2007 were invited for clinical and radiological review. The American Orthopaedic Foot and Ankle Society score, the American Academy of Orthopaedic Surgeons score and a visual analogue score for pain were used to assess outcome. A total of 274 patients were available; the mean follow-up was 9.7 years (8 to 18). The extent of any calcification or synostosis at the level of the distal interosseous membrane or syndesmosis on the contemporary radiographs was defined as: no or minor calcifications (group 1), severe calcification (group 2), or complete synostosis (group 3). . A total of 222 (81%) patients were in group 1, 37 (14%) in group 2 and 15 (5%) in group 3. There was no significant difference in incidence between AO type 44-B and type 44-C fractures (p = 0.89). Severe calcification or synostosis occurred in 21 patients (19%) in whom a syndesmotic screw was used and in 31 (19%) in whom a syndesmotic screw was not used.(p = 0.70). No significant differences were found between the groups except for a greater reduction in mean dorsiflexion in group 2 (p = 0.004). . This is the largest study on distal tibiofibular synostosis, and we found that a synostosis is a frequent complication of surgery for a fracture of the ankle. Although it theoretically impairs the range of movement of the ankle, it did not affect the outcome. . Our findings suggest that synostosis of the distal tibiofibular syndesmosis in general does not warrant treatment. Cite this article: Bone Joint J 2015;97-B:945–9


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 58 - 58
1 May 2012
Parker L Smitham P McCarthy I Garlick N
Full Access

Conventionally, medial malleolus fractures are treated surgically with anatomical reduction and internal fixation using screws. There seems to be no consensus, backed by scientific study on the optimal screw characteristics in the literature. We retrospectively examined case notes and radiographs of 48 consecutive patients taken from our trauma database (21 male, 27 female) with an average age of 50 years (range 16-85) who had undergone medial malleolus fracture fixation with screws at the Royal Free Hospital, London between January 2009 and June 2010. The most commonly used screw was the AO 4.0 mm diameter cancellous partially-threaded screw in 40, 45 and 50 mm lengths (40 mm n = 28, 45 mm n = 26, 50 mm n = 23) with the threads passing beyond the physeal scar in all cases. Incomplete reduction defined as > 1mm fracture displacement was observed on post-operative x-rays in 12 out of 48 cases (25%), all of which relied on partially-threaded screw fixation. In 5 cases where AO 4.0 mm diameter fully-threaded screws engaging the physeal scar had been used, no loss of reduction was observed. This unusual, occasional use of fully-threaded screws prompted us to investigate further using a porcine model and adapted pedo-barographic transducer. We compared pressures generated within the fracture site using AO 4.0 mm partially-threaded cannulated screws, 4.0 mm partially-threaded cancellous screws and 4.0 mm fully-threaded cancellous screws. Fully-threaded cancellous 4.0 mm diameter screws generated almost 3 times the compression of a partially-threaded cancellous screw with superior stability at the fracture. Partially-threaded screws quickly lost purchase, compression and stability particularly when they were cannulated. We also observed that screw thread purchase seemed enhanced in the physeal region. We conclude that fully-threaded cancellous 4.0 mm AO screws are superior to longer partially-threaded screws and that use of cannulated 4.0 mm partially-threaded screws should be avoided in fixation of medial malleolus fractures


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 812 - 817
1 Jun 2016
Verhage SM Boot F Schipper IB Hoogendoorn JM

Aims. Involvement of the posterior malleolus in fractures of the ankle probably adversely affects the functional outcome and may be associated with the development of post-traumatic osteoarthritis. Anatomical reduction is a predictor of a successful outcome. The purpose of this study was to describe the technique and short-term outcome of patients with trimalleolar fractures, who were treated surgically using a posterolateral approach in our hospital between 2010 and 2014. Patients and Methods. The study involved 52 patients. Their mean age was 49 years (22 to 79). There were 41 (79%) AO 44B-type and 11 (21%) 44C-type fractures. The mean size of the posterior fragment was 27% (10% to 52%) of the tibiotalar joint surface. Results. Reduction was anatomical in all patients with a residual step in the articular surface of ≤ 1 mm. In nine of the C-type fractures (82%), the syndesmosis was stable after fixation of the posterior fragment and a syndesmosis screw was not required. Apart from one superficial wound infection, there were no wound healing problems. At a mean radiological follow-up of 34 weeks (seven to 131), one patient with a 44C-type fracture had widening of the syndesmosis which required further surgery. Conclusion. We conclude that the posterolateral surgical approach to the ankle gives adequate access to the posterior malleolus, allowing its anatomical reduction and stable fixation: it has few complications. Take home message: Fixation of the posterior malleolus in trimalleolar fractures can be easily done via the posterolateral approach whereby anatomical reduction and stable fixation can be reached due to adequate visualisation of the fracture. Cite this article: Bone Joint J 2016;98-B:812–17


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 949 - 956
1 Sep 2024
Matthews PA Scammell BE Coughlin TA Nightingale J Ollivere BJ

Aims

This study aimed to compare the outcomes of two different postoperative management approaches following surgical fixation of ankle fractures: traditional cast immobilization versus the Early Motion and Directed Exercise (EMADE) programme.

Methods

A total of 157 patients aged 18 years or older who underwent successful open reduction and internal fixation (ORIF) of Weber B (AO44B) ankle fractures were recruited to this randomized controlled trial. At two weeks post-surgical fixation, participants were randomized to either light-weight cast-immobilization or the EMADE programme, consisting of progressive home exercises and weekly advice and education. Both groups were restricted to non-weightbearing until six weeks post-surgery. The primary outcome was assessed using the Olerud-Molander Ankle Score (OMAS) questionnaire at 12 weeks post-surgery, with secondary measures at two, six, 24, and 52 weeks. Exploratory cost-effectiveness analyses were also performed.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 502 - 509
20 Jun 2022
James HK Griffin J Pattison GTR

Aims

To identify a core outcome set of postoperative radiographic measurements to assess technical skill in ankle fracture open reduction internal fixation (ORIF), and to validate these against Van der Vleuten’s criteria for effective assessment.

Methods

An e-Delphi exercise was undertaken at a major trauma centre (n = 39) to identify relevant parameters. Feasibility was tested by two authors. Reliability and validity was tested using postoperative radiographs of ankle fracture operations performed by trainees enrolled in an educational trial (IRCTN 20431944). To determine construct validity, trainees were divided into novice (performed < ten cases at baseline) and intermediate groups (performed ≥ ten cases at baseline). To assess concurrent validity, the procedure-based assessment (PBA) was considered the gold standard. The inter-rater and intrarater reliability was tested using a randomly selected subset of 25 cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1100 - 1106
1 Aug 2010
Kapoor SK Kataria H Patra SR Boruah T

Open reduction and internal fixation of high-energy pilon fractures are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. A total of 17 consecutive patients with pilon fractures of AO/OTA type 43-B3 (n = 1), type C2 (n = 12) and type C3 (n = 4) were treated by indirect reduction by capsuloligamentotaxis and stabilisation using an ankle-spanning Ilizarov fixator. The calcaneal ring was removed at a mean of 3.7 weeks (3 to 6). A total of 16 patients were available for follow-up at a mean of 29 months (23 to 43). The mean time to healing was 15.8 weeks (13 to 23). Nine patients had pin-track infections but none had deep infection or osteomyelitis. Four patients (25%) had malunion. Fair, good or excellent ankle scores were found in 14 patients. External fixation with a ring fixator achieves stable reduction of the fractured fragments without additional trauma to soft tissues. With minimum complications and good healing results, the Ilizarov apparatus is particularly useful for high-energy pilon fractures


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 931 - 938
1 May 2021
Liu Y Lu H Xu H Xie W Chen X Fu Z Zhang D Jiang B

Aims

The morphology of medial malleolar fracture is highly variable and difficult to characterize without 3D reconstruction. There is also no universally accepeted classification system. Thus, we aimed to characterize fracture patterns of the medial malleolus and propose a classification scheme based on 3D CT reconstruction.

Methods

We retrospectively reviewed 537 consecutive cases of ankle fractures involving the medial malleolus treated in our institution. 3D fracture maps were produced by superimposing all the fracture lines onto a standard template. We sliced fracture fragments and the standard template based on selected sagittal and coronal planes to create 2D fracture maps, where angles α and β were measured. Angles α and β were defined as the acute angles formed by the fracture line and the horizontal line on the selected planes.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims

A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures.

Methods

A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods.


Introduction:. Inadequate reduction and fixation of ankle fractures leads to poor clinical outcomes although there are no well-established criteria to evaluate the quality of surgical fracture fixation of the ankle. The aim of our study was to validate Pettrone's criteria that can be used in the radiological assessment of the quality of ankle fracture fixation that predict the functional outcome. Methods:. A retrospective study was completed following the operative management of ankle fractures at a University teaching hospital between 1. st. January 2009 and 31. st. December 2009 were included in the study. Exclusion criteria were paediatric fractures, polytrauma, and fractures involving the tibial plafond. The fracture pattern was classified using the AO classification system. Three independent Foot and Ankle Consultants assessed the quality of surgical ankle fracture fixation using Pettrone's criteria. Approximately one year following the surgery, functional outcome was obtained using Lower Extremity Function Score (LEFS) and a modified American Orthopaedic Foot and Ankle Society score (AOFAS). The Mann-Whitney test was used for the LEFS and AOFAS functional scores. Logistic regression was performed upon age and gender with regards to functional outcome. Given that the Kappa coefficient is a pair wise statistic, the average pair wise agreement for each category of the Pettrone criteria was also determined. Results:. Sixty-one consecutive patients were included in the study with a mean age of 51 years (17–74 years) and a mean follow-up of 17.41 months (13–24 months). Using Pettrone's criterias, mean interobserver agreement was 90.0% (89.4–92.6%) with inadequate reduction in 20 cases (32.5%). Mean LEFS following inadequate reduction was 47.5 (1–79) and following satisfactory reduction was 55.9 (9–80) p=0.03. Conclusion:. Pettrone's criteria has high interobserver agreement for the quality of surgical fracture fixation of the ankle which correlates with functional outcome


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 8 - 8
1 Jan 2014
Lomax A Singh A Madeley N Kumar C
Full Access

Introduction:. In this cohort study, we present comprehensive injury specific and surgical outcome data from one of the largest reported series of distal tibial pilon fractures, treated in our tertiary referral centre. Methods:. A series of 76 pilon fractures were retrospectively reviewed from case notes, plain radiographs and computed tomography (CT) imaging. Patient demographics, injury and fracture patterns, methods and timing of fixation and clinical and radiological outcomes were assessed over a mean follow up period of 8.6 months (range 2–30). Results:. Definitive fixation was most commonly performed through an open technique with plate fixation. CT imaging was used to plan the most direct approach to access the fracture fragments. The majority of cases were classified as AO/OTA 43.C3. When definitive open fixation for closed fracture was performed within 48 hours, the rate of deep infection or wound complication was 0%. When performed on day 3–5, the deep infection rate was 0% but the superficial wound complication rate was 23.5%. From day six onwards, the deep infection rate was 4% and the superficial wound complication rate was 8%. The rate of wound complications after double plate fixation of the tibia using two separate incisions was 23.1%, compared to 11.7% after single incision and plating. The rate of non-union was 9.7%. Symptomatic post-traumatic arthritis requiring orthopaedic management occurred in 9.9%. Further surgery was required in 27.8% of all patients. Conclusion:. Outcomes from our unit compare favourably with those from large trauma centres worldwide. Our study supports the use of early definitive fixation, within 48 hours, to achieve low rates of wound complications. We support an “unsafe window” for definitive fixation of three to five days post injury due to the high rate of wound complications. The likelihood of developing post-traumatic arthritis and of requiring further surgery is high


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 35 - 35
1 Sep 2012
Choi C Hakim Z Lattouf G Shoaib A
Full Access

The treatment of very distal tibial fractures and pilon fractures is difficult. There is a wide variation in the severity of injury and the options for surgical management. Plates and external fixation each have their advantages. This retrospective study looks at complications and technical tips for anterolateral plating. 35 consecutive distal tibial platings were evaluated. The AO classification for each fracture was determined and any patient factors affecting outcome. Outcome variables included time to radiological union, infection rate, wound breakdown rate, and joint movement after treatment. There were 32 anterolateral platings and 3 medial platings. The union rate was 95%. There were two deep infections which required surgical treatment. There were two wound breakdowns, one of which required plastic surgical intervention. Two patients had prominent metalwork, requiring removal. Other complications included deep peroneal nerve palsy, stiffness, and vascular compromise. The complication rates were lower for surgeons operating more frequently on these fractures. Two patients subsequently required bone transport and one required an amputation. The complication rate found was similar to that reported in the literature. The few complications were however very significant for the patient and also for the surgeon as they required bone transport. Complications other than infection occurred in the few cases performed by surgeons low on their learning curve. We present technical tips for surgery. The presence of callus only after mobilisation indicates that union is slow. Anterolateral plating is a viable option for distal tibial fractures, especially 43B fractures. There is a learning curve associated with their use. Complication rates are low overall, but significant consequences can accompany complications. As an alternative to external fixation, distal locking plates are not a pain free option for the surgeon, as well as for the patient


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims

In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years.

Methods

A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 176 - 182
1 Feb 2018
Petrie MJ Blakey CM Chadwick C Davies HG Blundell CM Davies MB

Aims

Fractures of the navicular can occur in isolation but, owing to the intimate anatomical and biomechanical relationships, are often associated with other injuries to the neighbouring bones and joints in the foot. As a result, they can lead to long-term morbidity and poor function. Our aim in this study was to identify patterns of injury in a new classification system of traumatic fractures of the navicular, with consideration being given to the commonly associated injuries to the midfoot.

Patients and Methods

We undertook a retrospective review of 285 consecutive patients presenting over an eight- year period with a fracture of the navicular. Five common patterns of injury were identified and classified according to the radiological features. Type 1 fractures are dorsal avulsion injuries related to the capsule of the talonavicular joint. Type 2 fractures are isolated avulsion injuries to the tuberosity of the navicular. Type 3 fractures are a variant of tarsometatarsal fracture/dislocations creating instability of the medial ray. Type 4 fractures involve the body of the navicular with no associated injury to the lateral column and type 5 fractures occur in conjunction with disruption of the midtarsal joint with crushing of the medial or lateral, or both, columns of the foot.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 636 - 640
1 May 2014
Korim MT Payne R Bhatia M

Most of the literature on surgical site infections following the surgical treatment of fractures of the ankle is based on small series of patients, focusing on diabetics or the elderly. None have described post-operative functional scores in those patients who develop an infection. We performed an age- and gender-matched case–control study to identify patient- and surgery-related risk factors for surgical site infection following open reduction and internal fixation of a fracture of the ankle. Logistic regression analysis was used to identify significant risk factors for infection and to calculate odds ratios (OR). Function was assessed using the Olerud and Molander Ankle Score. The incidence of infection was 4% (29/717) and 1.1% (8/717) were deep infections. The median ankle score was significantly lower in the infection group compared with the control group (60 vs 90, Mann–Whitney test p < 0.0001). Multivariate regression analysis showed that diabetes (OR = 15, p = 0.031), nursing home residence (OR = 12, p = 0.018) and Weber C fractures (OR = 4, p = 0.048) were significant risk factors for infection.

A low incidence of infection following open reduction and internal fixation of fractures of the ankle was observed. Both superficial and deep infections result in lower functional scores.

Cite this article: Bone Joint J 2014;96-B:636–40.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 772 - 777
1 Jun 2007
von Knoch F Reckord U von Knoch M Sommer C

We investigated the clinical and radiological outcome after unilateral fracture of the lateral process of the talus in 23 snowboarders with a mean follow-up of 3.5 years (12 to 76 months). In this consecutive cohort study both operative and non-operative cases were considered.

The mean American Orthopaedic Foot and Ankle Society hindfoot score was 94 (82 to 100). The non-operative group of seven with a minimally-displaced fracture scored higher (98 points) than the operative group of 16 with displaced or unstable fractures (93 points). In 88% of operative cases, significant concomitant hindfoot injuries were found at operation. All but eight (35%) patients (six operative and two non-operative) regained their pre-injury level of sporting activity. Subtalar osteoarthritis was present in nine (45%) of the 20 patients available for radiological review, including one late-diagnosed non-operative case and eight operative cases with associated injuries or fracture comminution.

The outcome after fracture of the lateral process of the talus in snowboarders is favourable provided an early diagnosis is made and adequate treatment, which is related to the degree of displacement and associated injuries, is undertaken.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1055 - 1059
1 Aug 2007
Schock HJ Pinzur M Manion L Stover M

Supination-external rotation (SER) fractures of the ankle may present with a medial ligamentous injury that is not apparent on the initial radiographs. A cadaver gravity-stress view has been described, but the manual-stress view is considered to be the examination of choice for the diagnosis of medial injuries. We prospectively compared the efficacy of these two examinations.

We undertook both examinations in 29 patients with SER fractures. Of these, 16 (55%) were stress-positive, i.e. and had widening of the medial clear space of > 4 mm with a mean medial clear space of 6.09 mm (4.4 to 8.1) on gravity-stress and 5.81 mm (4.0 to 8.2) on manual-stress examination, and 13 patients (45%) were stress-negative with a mean medial clear space of 3.91 mm (3.3 to 5.1) and 3.61 mm (2.6 to 4.5) on examination of gravity- and manual-stress respectively. The mean absolute visual analgoue scale score for discomfort in the examination of gravity stress was 3.45 (1 to 6) and in the manual-stress procedure 6.14 (3 to 10).

We have shown that examination of gravity-stress is as reliable and perceived as more comfortable than that of manual stress. We recommend using it as the initial diagnostic screening examination for the detection of occult medial ligamentous injuries in SER fractures of the ankle.