Introduction. Robotic-assisted hip arthroplasty helps acetabular preparation and implantation with the assistance of a robotic arm. A computed tomography (CT)-based navigation system is also helpful for acetabular preparation and implantation, however, there is no report to compare these methods. The purpose of this study is to compare the acetabular cup position between the assistance of the robotic arm and the CT-based navigation system in total hip arthroplasty for patients with osteoarthritis secondary to developmental dysplasia of the hip. Methods. We studied 31 hips of 28 patients who underwent the robotic-assisted hip arthroplasty (MAKO group) between August 2018 and March 2019 and 119 hips of 112 patients who received THA under CT-based navigation (CT-navi group) between September 2015 and November 2018. The preoperative diagnosis of all patients was osteoarthritis secondary to developmental dysplasia of the hip. They received the same cementless cup (Trident, Stryker). Robotic-assisted hip arthroplasty were performed by four surgeons while THA under CT-based navigation were performed by single senior surgeon. Target angle was 40 degree of radiological cup inclination (RI) and 15 degree of radiological cup anteversion (RA) in all patients. Propensity score matching was used to match the patients by gender, age, weight, height, BMI, and surgical approach in the two groups and 30 patients in each group were included in this study. Postoperative cup position was assessed using postoperative anterior-posterior pelvic radiograph by the Lewinnek's methods. The differences between target and postoperative cup position were investigated. Results. The acetabular cup position of all cases in both Mako and CT-navi group within Lewinnek's safe zone (RI: 40±10 degree; RA: 15±10 degree) in group were within this zone. Three was no significant difference of RI between Mako and CT-navi group (40.0 ± 2.1 degree vs 39.7± 3.6 degree). RA was 15.0 ± 1.2 degree and 17.0 ± 1.9 degree in MAKO group and in CT-navi group, respectively, with significant difference (p<0.001). The differences of RA between target and postoperative angle were smaller in MAKO group than CT-navi group (0.60± 1.05 degree vs 2.34± 1.40 degree, p<0.001). The difference or RI in MAKO group was smaller than in CT-navi, however, there was no significance between them (1.67± 1.27 degree vs 2.39± 2.68 degree, p=0.197). Conclusions. Both the assistance of the robotic arm and the CT-based navigation system were helpful to achieve the acetabular cup implantation, however, MAKO system achieved more accurate acetabular cup implantation than CT-based navigation system in total hip arthroplasty for the patients with OA secondary to DDH. Longer follow-up is necessary to investigate the clinical outcome


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 138 - 138
1 Apr 2019
Harold R Delagrammaticas D Stover M Manning DW
Full Access

Background. Supine positioning during direct anterior approach total hip arthroplasty (DAA THA) facilitates use of fluoroscopy, which has been shown to improve acetabular component positioning on plane radiograph. This study aims to compare 2- dimensional intraoperative radiographic measurements of acetabular component position with RadLink to postoperative 3- dimensional SterEOS measurements. Methods. Intraoperative fluoroscopy and RadLink (El Segundo, CA) were used to measure acetabular cup position intraoperatively in 48 patients undergoing DAA THA. Cup position was measured on 6-week postoperative standing EOS images using 3D SterEOS software and compared to RadLink findings using Student's t-test. Safe-zone outliers were identified. We evaluated for measurement difference of > +/− 5 degrees. Results. RadLink acetabular cup abduction measurement (mean 43.0°) was not significantly different than 3D SterEOS in the anatomic plane (mean 42.6°, p = 0.50) or in the functional plane (mean 42.7°, p = 0.61) (Fig. 1–2). RadLink acetabular cup anteversion measurement (mean 17.9°) was significantly different than 3D SterEOS in both the anatomic plane (mean 20.6°, p = 0.022) and the functional plane (mean 21.2°, p = 0.002) (Fig. 3–4). RadLink identified two cups outside of the safe-zone. However, SterEOS identified 12 (anatomic plane) and 10 (functional plane) outside of the safe-zone (Fig. 5–7). In the functional plane, 58% of anteversion and 92% of abduction RadLink measurements were within +/− 5° of 3D SterEOS. Conclusion. Intraoperative fluoroscopic RadLink acetabular anteversion measurements are significantly different than 3D SterEOS measurements, while abduction measurements are similar. Significantly more acetabular cups are placed outside of the safe- zone when evaluated with 3D SterEOS versus RadLink


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 178 - 178
1 Mar 2013
Funayama A Okubo M Shimizu H Kawasakiya S Fujie A Toyama Y
Full Access

Introduction

The goal of total hip arthroplasty (THA) should be to reconstruct the acetabulum by positioning the hip center as close as possible to the anatomical hip center. However, the true position of the anatomic hip center can be difficult to determine during surgery on an individual basis. In 2005, we designed, produced an acetabular reaming guide, and clinically used to enable cup placement in the ideal anatomical position. This study was examined the accuracy the reaming guide for THA in prospective study.

Methods

This guide was applied consecutive 230 patients in primary THA. During planning, the distance from the acetabular edge to the reaming center and from the center to the perpendicular of the inter-teardrop line was measured on an anteroposterior (AP) X-ray. The reaming guide was adjusted depend on the reaming center by based planning. Acetabular reaming was performed with the process reamer.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 105 - 105
10 Feb 2023
Xu J Veltman W Chai Y Walter W
Full Access

Navigation in total hip arthroplasty has been shown to improve acetabular positioning and can decrease the incidence of mal-positioned acetabular components. The aim of this study was to assess two surgical guidance systems by comparing intra-operative measurements of acetabular component inclination and anteversion with a post-operative CT scan. We prospectively collected intra-operative navigation data from 102 hips receiving conventional THA or hip resurfacing arthroplasty through either a direct anterior or posterior approach. Two guidance systems were used simultaneously: an inertial navigation system (INS) and optical navigation system (ONS). Acetabular component anteversion and inclination was measured on a post-operative CT. The average age of the patients was 64 years (range: 24-92) and average BMI was 27 kg/m. 2. (range 19-38). 52% had hip surgery through an anterior approach. 98% of the INS measurements and 88% of the ONS measurements were within 10° of the CT measurements. The mean (and standard deviation) of the absolute difference between the post-operative CT and the intra-operative measurements for inclination and anteversion were 3.0° (2.8) and 4.5° (3.2) respectively for the ONS, along with 2.1° (2.3) and 2.4° (2.1) respectively for the INS. There was significantly lower mean absolute difference to CT for the INS when compared to ONS in both anteversion (p<0.001) and inclination (p=0.02). Both types of navigation produced reliable and reproducible acetabular cup positioning. It is important that patient-specific planning and navigation are used together to ensure that surgeons are targeting the optimal acetabular cup position. This assistance with cup positioning can provide benefits over free-hand techniques, especially in patients with an altered acetabular structure or extensive acetabular bone loss. In conclusion, both ONS and INS allowed for adequate acetabular positioning as measured on postoperative CT, and thus provide reliable intraoperative feedback for optimal acetabular component placement


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 29 - 29
1 Feb 2020
Abe I Shirai C
Full Access

Background. Accurate acetabular cup positioning is considered to be essential to prevent postoperative dislocation and improve the long-term outcome of total hip arthroplasty (THA). Recently various devices such as navigation systems and patient-specific guides have been used to ensure the accuracy of acetabular cup positioning. Objectives. The present study evaluated the usefulness of CT-based three-dimensional THA preoperative planning for acetabular cup positioning. Methods. This study included 120 hips aged mean 68.3 years, who underwent primary THA using CT-based THA preoperative planning software ZedHip® (LEXI, Tokyo Japan) and postoperative CT imaging (Fig.1). The surgical approach adopted the modified Watson-Jones approach in the lateral decubitus position and Trident HA acetabular cups were used for all cases. Preoperatively the optimum cup size and position in the acetabular were decided using the ZedHip® software, taking into consideration femoral anteversion and to achieve the maximum range of motion in dynamic motion simulation. Radiographic inclination (RI) was selected in the range between 40°∼45° and radiographic anteversion (RA) in the range between 5°∼25°. Three-dimensional planning images of the cup positioning were obtained from the ZedHip® software, and the distances between the edge of the implant and anatomical landmarks such as the edge of the anterior or superior acetabular wall were measured on the three-dimensional images and recorded (Fig.2). Intraoperatively, the RI and RA were confirmed by reference to these distances and the acetabular cup was inserted. Relative positional information of the implant was extracted from postoperative CT imaging using the ZedHip® software and used to reproduce the position of the implant on preoperative CT imaging with the software image matching function. The difference between the preoperative planning and the actual implant position was measured to assess the accuracy of acetabular cup positioning using the ZedHip® software. Results. Actual cup size corresponded with that of preoperative planning in 95% of cases (114 hips). Postoperative mean RI was 42.3° ± 4.2° (95% confidence interval (CI), 41.5° ∼ 43.0°) and mean RA was 16.1° ± 5.9° (95%CI, 15.0° ∼ 17.1°). Deviation from the target RI was 4.2° ± 3.7° (95%CI, 3.5° ∼ 4.9°) and deviation from the target RA was 4.0° ± 3.6° (95%CI, 3.4° ∼ 4.7°). Overall 116 hips (96.7%) were within the RI safe zone (30° ∼ 50°) and 108 hips (90.0%) were within the RA safe zone (5° ∼ 25°), and 105 hips (87.5%) were within both the RI and RA safe zones (Fig.3). Mean cup shift from preoperative planning was 0.0mm ± 3.0mm to the cranial side in the cranio-caudal direction, 2.1mm ± 3.0mm to the anterior side in the antero-posterior direction, and 1.7mm ± 2.1mm to the lateral side in the medio-lateral direction. Conclusion. The accuracy of acetabular cup positioning using our method of CT-based three-dimensional THA preoperative planning was slightly inferior to reported values for CT-based navigation, but obviously superior to those without navigation and similar to those with portable navigation. CT-based three-dimensional THA preoperative planning is effective for acetabular cup positioning, and has better cost performance than expensive CT-based navigation. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 34 - 34
10 Feb 2023
Farey J Chai Y Xu J Sadeghpour A Marsden-Jones D Baker N Vigdorchik J Walter W
Full Access

Imageless computer navigation systems have the potential to improve acetabular cup position in total hip arthroplasty (THA), thereby reducing the risk of revision surgery. This study aimed to evaluate the accuracy of three alternate registration planes in the supine surgical position generated using imageless navigation for patients undergoing THA via the direct anterior approach (DAA). Fifty-one participants who underwent a primary THA for osteoarthritis were assessed in the supine position using both optical and inertial sensor imageless navigation systems. Three registration planes were recorded: the anterior pelvic plane (APP) method, the anterior superior iliac spines (ASIS) functional method, and the Table Tilt (TT) functional method. Post-operative acetabular cup position was assessed using CT scans and converted to radiographic inclination and anteversion. Two repeated measures analysis of variance (ANOVA) and Bland-Altman plots were used to assess errors and agreement of the final cup position. For inclination, the mean absolute error was lower using the TT functional method (2.4°±1.7°) than the ASIS functional method (2.8°±1.7°, ρ = .17), and the ASIS anatomic method (3.7°±2.1, ρ < .001). For anteversion, the mean absolute error was significantly lower for the TT functional method (2.4°±1.8°) than the ASIS functional method (3.9°±3.2°, ρ = .005), and the ASIS anatomic method (9.1°±6.2°, ρ < .001). All measurements were within ± 10° for the TT method, but not the ASIS functional or APP methods. A functional registration plane is preferable to an anatomic reference plane to measure intra-operative acetabular cup inclination and anteversion accurately. Accuracy may be further improved by registering patient location using their position on the operating table rather than anatomic landmarks, particularly if a tighter target window of ± 5° is desired


Abstract. Optimal acetabular component position in Total Hip Arthroplasty is vital for avoiding complications such as dislocation and impingement, Transverse acetabular ligament (TAL) have been shown to be a reliable landmark to guide optimum acetabular cup position. Reports of iliopsoas impingement caused by acetabular components exist. The Psoas fossa (PF) is not a well-regarded landmark for Component positioning. Our aim was to assess the relationship of the TAL and PF in relation to Acetabular Component positioning. A total of 22 cadavers were implanted on 4 occasions with the an uncemented acetabular component. Measurements were taken between the inner edge of TAL and the base of the acetabular component and the distance between the lower end of the PF and the most medial end of TAL. The distance between the edge of the acetabular component and TAL was a mean of 1.6cm (range 1.4–18cm). The distance between the medial end of TAL and the lowest part of PF was a mean of 1.cm (range 1,3–1.8cm) It was evident that the edge of PF was not aligned with TAL. Optimal acetabular component position is vital to the longevity and outcome following THA. TAL provides a landmark to guide acetabular component position. However we feel the PF is a better landmark to allow appropriate positioning of the acetabular component inside edge of the acetabulum inside the bone without exposure of the component rim and thus preventing iliopsoas impingement at the psoas notch and resultant groin pain


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 44 - 44
1 Feb 2020
Mays R Benson J Muir J White P Meftah M
Full Access

Proper positioning of the acetabular cup deters dislocation after total hip arthroplasty (THA) and is therefore a key focus for orthopedic surgeons. The concept of a safe zone for acetabular component placement was first characterized by Lewinnek et al. and furthered by Callanan et al. The safe zone concept remains widely utilized and accepted in contemporary THA practice; however, components positioned in this safe zone still dislocate. This study sought to characterize current mass trends in cup position identified across a large study sample of THA procedures completed by multiple surgeons. This retrospective, observational study reviewed acetabular cup position in 1,236 patients who underwent THA using computer-assisted navigation (CAS) between July 2015 and November 2017. Outcomes included acetabular cup position (inclination and anteversion) measurements derived from the surgical navigation device and surgical approach. The overall mean cup position of all recorded cases was 21.8° (±7.7°, 95% CI = 6.7°, 36.9°) of anteversion and 40.9° (±6.5°, 95% CI = 28.1°, 53.7°) of inclination (Table 1). For both anteversion and inclination, 65.5% (809/1236) of acetabular cup components were within the Lewinnek safe zone and 58.4% (722/1236) were within the Callanan safe zone. Acetabular cups were placed a mean of 6.8° of anteversion (posterior/lateral approach: 7.0°, anterior approach: 5.6°) higher than the Lewinnek and Callanan safe zones whereas inclination was positioned 0.9° higher than the reported Lewinnek safe zone and 3.4° higher than the Callanan safe zone (Figure 1,2). Our data shows that while the majority of acetabular cups were placed within the traditional safe zones, the mean anteversion orientation is considerably higher than those suggested by the Lewinnek and Callanan safe zones. The implications of this observation warrant further investigation. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 104 - 104
1 Jun 2012
Dorr L Pagnano M Trousdale R Thompson M Jamieson M Conditt M
Full Access

Introduction. Recent gains in knowledge reveal that the ideal acetabular cup position is in a narrower range than previously appreciated and that position is likely different based on femoral component anteversion. For that reason more accurate acetabular cup positioning techniques will be important for contemporary THA. It is well known that malalignment of the acetabular component in THA may result in dislocation, reduced range of motion or accelerated wear. Up to 8% of THA patients have cups malaligned in version by more than ±10° outside of the Lewinnek safe zone. This type of malalignment may result in dislocation of the femoral head and instability of the joint within the first year, requiring reoperation. Reported incidences of reoperation are 1-9% depending on surgical skills and technique. In addition, cup malalignment is becoming increasingly important as adoption of hard on hard bearings increases as the success of large head hard on hard bearings seems to be more sensitive to cup positioning. This study reports the accuracy of a haptic robotic system to ream the acetabulum and impact an acetabular cup compared to manual instrumentation. Methods. Six fresh frozen cadaveric acetabula were CT scanned and three-dimensional templating of the center of rotation, anteversion and inclination of the cup was determined pre-operatively. Half of the specimens were prepared with manual instrumentation while half were prepared with robotic guidance. Haptic and visual feedback were provided through robotics and an associated navigation system to guide reaming and impaction of the cup. The robot constrained the orientation and position of the instruments thus constraining the inclination, anteversion and center of rotation of the reamer, trial and the final cup. Post-operative CT's were used to determine the achieved cup placement and compared to the pre-operative plans. Results. In all cases, robotic guidance resulted in placement of the acetabular cup within ±3° of anteversion, ±3° of relative to the pre-op plan. The average absolute inclination error was 1.5±1.2° and the average absolute anteversion error 1.3±1.4°. Cup placement with robotic assistance was significantly more accurate and precise than with manual instrumentation. With manual instrumentation the errors were, on average, 4.2 times higher in inclination and 4.8 times higher in anteversion compared to robotic instrumentation. Conclusion. This haptic robotic system substantially improved the accuracy of acetabular reaming and placement of the final cup compared to traditional manual techniques. With greater knowledge of ideal acetabular cup position, highly accurate techniques may allow surgeons to decrease the risk of dislocation, promote durability and improve the ability to restore appropriate leg length and offset. Haptic robotics has proven to be safe and effective in both knee and hip surgery and provides the potential to redefine the “instrument set” used for orthopedic procedures


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 97 - 97
1 Feb 2017
DelSole E Vigdorchik J Schwarzkopf R Buckland A
Full Access

Background. Spinal deformity has a known deleterious effect upon the outcomes of total hip arthroplasty and acetabular component positioning. This study sought to evaluate the relationship between severity of spinal deformity parameters and acetabular cup position, rate of dislocation, and rate of revision among patients with total hip arthroplasties and concomitant spinal deformity. Methods. A prospectively collected database of patients with spinal deformity was reviewed and patients with total hip arthroplasty were identified. The full body standing stereoradiographic images (EOS) were reviewed for each patient. From these images, spinal deformity parameters and acetabular cup anteversion and inclination were measured. A chart review was performed on all patients to determine dislocation and revision arthroplasty events. Statistical analysis was performed to determine correlation of deformity with acetabular cup position. Subgroup analysis was performed for patients with spinal fusion, dislocation events, and revision THA. Results. One-hundred and seven spinal deformity patients were identified, with 139 hips for analysis. The rate of THA dislocation in this cohort was 8.0%, with a revision rate of 5.8% for instability. Patients who sustained dislocations had significantly higher spinopelvic tilt, T1-pelvic angle, and mismatch of lumbar lordosis and pelvic incidence. Among all patients, only 68.8% met the radiographic “safe zone” for anteversion in the standing position (Figure 1). A comparison of radiographic cup position on supine x-ray with standing EOS imaging demonstrated an increase in anteversion of 6.2 degrees. Standing decreased rate of safe zone anteversion of the cup by 20%. Conclusions. In this cohort, patients with THA and concomitant spinal deformity have a particularly high rate of dislocation. This dislocation risk may be driven by the degree of spinal deformity and by spinopelvic compensation, which is suggested by our findings. Arthroplasty surgeons should be aware of the elevated dislocation rate and consider a surgical strategy for maintaining hip stability in this population


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 43 - 43
1 Sep 2014
Ashour R Maritz M Goga I
Full Access

Purpose of the study. We reviewed one hundred and twenty patients who had primary total hip replacement using Corail/Pinnacle Metal on metal bearing surfaces between 2006 and 2009. We were interested in the metal ion levels of the whole cohort, the incidence of unexplained pain, pseudo tumour lesions (ALVAL) and early loosening and failure. We were particularly interested in the relationship of the acetabular cup position in relation to the pelvis and lumbar spine. Material and methods. We reviewed 120 charts and 104 patients in total. All patients had metal ion assays (cobalt and chromium). All patients had standardised radiographic evaluation using a special technique to assess acetabular cup position and the relationship to the pelvis and lumbar spine. Results. Ten patients had mild hip pain. This was not considered to be pathological pain related to the MOM articulation. None of the patients had any generalised symptoms of metal allergy as reported in the literature. We detected one patient with soft tissue fluid collections suggestive of an ALVAL lesion on ultrasound. The average cup inclination was 48 degrees with a range from 34 to 53 degrees. Conclusion. Our experience at 5 years with the Corail/Pinnacle Metal on Metal articulation has been acceptable. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 86 - 86
1 Jan 2016
Kamara E Robinson J Hepinstall M Rodriguez J
Full Access

Introduction. Total hip arthroplasty is considered to be one of the most successful orthopaedic interventions. Acetabular component positioning has been shown to affect dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. The safe zones of acetabular component positioning have previously been described by Lewinnek et al. as 5 to 25 degrees of cup version and 30 to 50 degrees of inclination. Callanan et al. later modified the inclination to 30 to 45 degrees. Our aim was to assess whether THA via robotic assisted posterior approach (PA) improves acetabular component positioning compared to fluoroscopic guided anterior approach THA (AA). Methods. Subjects. This study is a matched-pair case-control study using prospectively collected data from THAs done between January 2012 and December 2013. Patients who underwent primary THA using the PA or AA by the senior surgeons (MH and JAR) were included in the study. Ninety-six patients (of 176; 55%) underwent AA and 80 (of 176; 45%) underwent PA THAs. The matching process was performed by an observer blinded to the radiographic outcomes (EK). Patients were matched for sex and BMI +− 8 units. Seventy-nine patients who had AAs were manually matched to 79 patients who had PAs. Surgical Techniques. For the AA THAs, the patient is supine and the approach is performed through a modified smith Peterson approach. Acetabular cup positioning is assessed intraoperatively with fluoroscopy. For the PA THAs, the patient in the lateral position using the posterior approach. Acetabular cup positioning was guided by the MAKO robotic hip system using preoperative CT scans of the involved hip. Radiographic Measurements. The radiographic measurements were done manually using a standardized technique by two observers blinded to the type of arthroplasty performed. Spearman's rank correlation coefficient was used to test user dependent variability. Means were used for final calculations. Statistical Analysis. The average cup inclination and anteversion angles were calculated. Calculation of the number of hips that were in the safe zones of Lewinnek (inclination, 30°–50°; anteversion, 5°–25°) and Callanan (inclination, 30°–45°; anteversion, 5°–25°) regarding inclination, anteversion, and a combination of both were done for both groups. Independent t-tests were performed to compare both groups for sex, BMI, and inclination and anteversion angles. Fisher's exact test was used to compare both groups regarding the number of hips in the safe zones of Lewinnek and Callanan. Relative risk and absolute risk reduction were calculated. Results. There was no significant difference in BMI between the two groups. Intraobserver agreement was found to be .92 and 0.82 for inclination and anteversion, respectively. Compared to fluoroscopic guided THAs, THAs performed with robot assistance were found to be more often in the safe zone of Lewinnek (90% vs. 75%, p=0.02, RR 0.40 [0.19–0.85] p=0.01). This pattern was observed in the zone of Callanan and approached statistical significance (80% vs. 68%, p=0.11, RR 0.64 [0.37–1.10] p=0.11). Conclusion. Compared to fluoroscopic assisted THA, robot assisted THAs are more likely to be within the safe zone of Callanan and Lewinnek


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 105 - 105
1 Dec 2013
Zietz C Kluess D Fabry C Baum F Mittelmeier W Bader R
Full Access

Current implant designs and materials provide a high grade of quality and safety, but aseptic implant loosening is still the main reason for total hip revision. Highly cross-linked polyethylene (HX-PE) is used successfully in total hip replacements (THR) since several years. The good wear properties lead to a reduction of wear debris and may contribute to a longer survival time of the THRs. Furthermore, thin HX-PE liner allows the use of larger femoral heads associated with a decreased risk of dislocation and an improved range of motion. However, the cross-linking process is associated with a loss of mechanical properties of the polyethylene material which compromise the use of thin HX-PE liner in terms of high stress situations. The aim of the present study was the experimental wear analysis of HX-PE liner under steep acetabular cup position. Furthermore, a finite element analysis (FEA) was performed in order to calculate the stress within the HX-PE material in case of steep cup position under physiological loading. Experimental wear testing was performed for 5 Mio load cycles, using highly cross-linked polyethylene (HX-PE) acetabular liner combined with 44 mm ceramic femoral heads at a standard position of the acetabular cup (30° inclination) according to ISO 14242 as well as at 60° cup inclination. The wall thickness of the HX-PE liner was 3.8 mm. A hip wear simulator, according to ISO 14242 (EndoLab GmbH, Rosenheim, Germany), was used and wear was determined gravimetrically. Moreover, finite element models of the THR system at standard and steep cup position was created by Abaqus/CAE (Dessault Systemes Providence, USA). Using the finite element software Abaqus (Dessault Systemes Providence, USA) the total hip implants were physiologically loaded with maximum force of the gait cycle (3.0 kN). Thereby, the stresses within the HX-PE material were analysed. The average gravimetrical wear rates of the HX-PE liners at standard implant position (30°) and 60° cup inclination showed small wear amounts of 3.15 ± 0.32 mg and 1.92 ± 1.00 mg per million cycles, respectively. The FEA revealed a clear increase of stresses at the HX-PE liner with respect to steep cup position (von Mises stress of 8.78 MPa) compared to ISO standard implant position (von Mises stress of 5.70 MPa). The wear simulator tests could not demonstrate significant differences of gravimetrical wear amount of HX-PE liners under steep hip cup position compared to standard implant position. The small contact surface between the femoral head and the SX-PE liner during the wear testing may lead to the low wear rate of the misaligned acetabluar cup. Moreover, the FEA showed that the effect of a misaligned acetabular cup on the stresses within the polyethylene liner can be critical. Although an increase of wear could not be detected a steeper acetabular cup position using thin HX-PE liners should be avoided due to higher stresses preventing implant failure in clinical application


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 96 - 96
1 May 2019
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in (THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intraoperative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intraoperative fluoroscopy time


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 93 - 93
1 Feb 2020
Cipparone N Robinson M Chen J Muir J Shah R
Full Access

Acetabular cup positioning remains a real challenge and component malpositioning after total hip arthroplasty (THA) can lead to increased rates of dislocation and wear. It is a common cause for revision THA. A novel 3D imageless mini-optical navigation system was used during THA to provide accurate, intraoperative, real-time, and non-fluoroscopic data including component positioning to the surgeon. This retrospective comparative single surgeon and single approach study examined acetabular component positioning between traditional mini-posterolateral THA and mini-posterolateral THA using the 3D mini-optical navigation system. A retrospective chart review was conducted of 157 consecutive (78 3D mini-optical navigation and 79 traditional non-navigation methods) THAs performed by the senior author using a mini-posterolateral approach at an ambulatory surgery center and hospital setting. Two independent reviewers analyzed postoperative radiographs in a standardized fashion to measure acetabular component positioning. Demographic, clinical, surgical, and radiographic data were analyzed. These groups were found to have no statistical difference in age, gender, and BMI (Table I). There was no difference between groups in acetabular components in the Lewinnek safe zone, 31.2% vs 26.6% (p = 0.53). Cup anteversion within the safe zone did not differ, 35.1% vs 40.5% (p = 0.48); while cup inclination within the safe zone differed, with more in the navigation group, 77.9% vs 51.9% (p < 0.01). Change in leg length was significantly different with the navigation group's leg length at 1.9 ± 6.3, less than the traditional at 5.4 ± 7.0 (p < 0.01). There was no difference in mean change in offset between groups (4.5 ± 5.9 vs 6.2 ± 7.9, p = 0.12); navigation, traditional) (Table II). The 3D mini-optical navigation group did have significantly longer operative time (98.4 ± 17.5 vs 89.3 ± 15.5 p < 0.01). Use of the novel 3D Mini-optical Navigation System significantly improved cup inclination compared to traditional methods while increasing operative time. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 55 - 55
1 Jun 2018
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer-based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intra-operative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intra-operative fluoroscopy time


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 111 - 111
1 Aug 2017
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even for experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intra-operative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intra-operative fluoroscopy time


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 87 - 87
1 Nov 2016
Penenberg B
Full Access

Despite our best efforts, orthopaedic surgeons do not always achieve desired results in acetabular cup positioning in total hip arthroplasty (THA). Although ideal abduction and anteversion angles vary depending on surgeon preference, patient factors and anatomy, studies have shown that improperly positioned cups lead to increased failure rates in THA. While there have been many technological advancements in THA, including using CT-guided and fluoroscopic techniques, the cost for the hospital and time required to use this technology sometimes force hospitals not to use them. New advancements in digital radiography and image analysis software allow contemporaneous assessment of cup position in real-time during the surgical procedure. Intra-operative, or “trial radiographs” with the patient in lateral decubitus position can be digitally manipulated to match pre-operative radiographs obtained with patients in the supine position to enable calculation of the abduction and anteversion angle in these patients. In our single surgeon experience, digital radiography takes approximately 4–6 seconds in order to obtain an AP pelvic radiograph. The use of the software to measure the cup position adds only 1–2 minutes to the operative time and minimises interference with workflow. The adjustments that can be made intra-operatively with this technology allow the surgeon to learn what factors in his surgical approach and technique are useful in achieving the desired component position. This allows the surgeon to have precise control over the cup position during the operation rather than experience disappointment and frustration while viewing the post-operative film. This cost-effective and efficient tool allows the surgeons to achieve the best results for their patients in real time without having to leave the operating room


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 112 - 112
1 Jan 2016
Kitcharanant N Pongpirul K
Full Access

Purpose. To update recent findings about the relationship between obesity and post-operative outcome including acetabular cup positioning, complications, readmissions and revision rates, and also inpatient rehabilitation outcome following total hip arthroplasty. Methods. A literature review was done using standard keyword search. Articles were scrutinized by the investigators to ensure relevancy to the purpose of this review. Summary of the review. As the number of all obese(body mass index(BMI) >30) are rising, the development of hip osteoarthritis and the need for total hip arthroplasty(THA) increased. Recent studies found that high BMI was the most significant risk factor contributed to acetabular cup malpositioning following THA. Obesity was found to be a predicting factor for 30-day readmission due to complications include wound infections and thromboembolism after THA. A meta-analysis had shown increased rates of aseptic loosening, dislocation and infection in obese patients thus resulted in higher revision rates compared to nonobese patients but the increase was not found to be statistically significant. Obese patients can make functional improvements during inpatient rehabilitation but at slow progress and higher cost. Conclusion. Based on the current literature, obesity may have a negative impact on the outcome of THA. It appeared that as BMI increases, obesity was related with the risk of postoperative complications, and affected outcomes after total hip arthroplasty. Therefore, this needs to be informed to every patient prior to considering total hip arthroplasty


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 135 - 135
1 Mar 2017
Samagh S Penenberg B Woehnl A Brien W
Full Access

INTRODUCTION. Despite our best efforts, orthopaedic surgeons do not always achieve desired results in acetabular cup positioning in total hip arthroplasty. New advancements in digital radiography and image analysis software allow contemporaneous assessment of cup position in real-time during the surgical procedure. The purpose of this study was to describe and validate a technique in obtaining a true AP Pelvis radiograph in the lateral decubitus position to accurately assess cup position intra-operatively (Figure 1). METHODS. 350 consecutive patients undergoing THA through a soft-tissue sparing posterior approach were prospectively enrolled. Standard pre-operative supine radiographs were taken in the office to serve as a reference for intra-operative pelvic orientation and templating. Intra-operative AP Pelvis radiographs were obtained with the patient in the lateral decubitus position to appropriately match the pre-operative radiograph. Adjustments were made to correct for pelvic rotation by rotating the operating room table forward or backward. Radiographic beam angle adjustments allowed the surgeon to match pre-operative and intra-operative pelvic tilt (Figure 2). Two independent observers measured cup abduction angle. RESULTS. 95% of cups were placed within 30–50 degrees of abduction, with a mean angle of 38 degrees (STD +/− 5). 100% of cups measured post-operatively were placed within 3 degrees of their intra-operative measurement. Mean anteversion was 27.5 degrees (STD +/− 3.5). Intra-operative radiographs were repeated in 88% of cases in order to match to the pre-operative radiographs. The cup was repositioned in 28% of cases based on intra-operative measurements. Impingement during range of motion testing occurred in 3% of cases despite acceptable measurements, necessitating cup reposition. The intercross correlation coefficient between the two observers was 0.92. There was one dislocation reported in the 2-year follow-up. Changes in the pelvic inlet and outlet orientation changed the abduction angle measurement in a predictable way. We developed a formula and 3D model to predict the abudction angle based on the pelvic tilt, where a more outlet view would increase the abduction angle measurement (Figure 3). DISCUSSION AND CONCLUSION. Advancements in digital radiography allow for real-time cup position assessment, creating the opportunity for the surgeon to make the appropriate changes and confirm precise placement during the procedure. For figures/tables, please contact authors directly.