Advertisement for orthosearch.org.uk
Results 1 - 20 of 294
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 5 - 5
1 Feb 2020
Jenny J Guillotin C Boeri C
Full Access

Introduction. Chronic ruptures of the quadriceps tendon after total knee arthroplasty (TKA) are rare but are a devastating complication. The objective of this study was to validate the use of fresh frozen total fresh quadriceps tendon allografts for quadriceps tendon reconstruction. The hypothesis of this work was that the graft was functional in more than 67% of cases, a higher percentage than the results of conventional treatments. Material – methods. We designed a continuous monocentric retrospective study of all patients operated on between 2009 and 2017 for a chronic rupture of the quadriceps tendon after TKA by quadriceps allograft reconstruction. The usual demographic and perioperative data and the rehabilitation protocols followed were collected. Initial and final radiographs were analyzed to measure patellar height variation. The main criterion was the possibility of achieving an active extension of the knee with a quadriceps contraction force greater than or equal to 3/5 or the possibility of lifting the heel off the ground in a sitting position. Results. 29 patients with 33 allografts were included; 3 iterative allografts were performed on ruptures of the initial transplant and 1 patient was grafted on both sides in one step. There were 21 women and 8 men with a mean age of 73 years, and a mean body mass index of 33 kg/m. 2. Ruptures occurred in 22 cases after chronic periprosthetic infection. Walking was allowed immediately in 29 cases, but free mobilization was delayed in 29 cases. Complications affected 22 cases, but the majority of complications were not related to allograft use (including infectious failures and periprosthetic fractures). After a mean follow-up of 52 months, 28 allografts were still in place, and 22 allografts were considered functional. The active quadriceps extension force was rated on average at 3.5/5. The average pre/post-operative patellar height differential was +2 mm. Discussion. This continuous series of 33 allografts is in line with recent publications on the subject. It confirms their negative impact on the functional outcome of the TKA. The complication rate is high but the specific complication rate is not prohibitive. Two thirds of transplants are functional in the long term. Early rehabilitation procedures can be used in these difficult patients with encouraging results. The management of chronic ruptures of the quadriceps tendon after TKA by quadriceps allograft must be part of the current therapeutic options


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 74 - 74
1 Dec 2022
Changoor A Suderman R Wood B Grynpas M Hurtig M Kuzyk P
Full Access

Large cartilage lesions in younger patients can be treated by fresh osteochondral allograft transplantation, a surgical technique that relies on stable initial fixation and a minimum chondrocyte viability of 70% in the donor tissue to be successful. The Missouri Osteochondral Allograft Preservation System (MOPS) may extend the time when stored osteochondral tissues remain viable. This study aimed to provide an independent evaluation of MOPS storage by evaluating chondrocyte viability, chondrocyte metabolism, and the cartilage extracellular matrix using an ovine model. Femoral condyles from twelve female Arcott sheep (6 years, 70 ± 15 kg) were assigned to storage times of 0 (control), 14, 28, or 56 days. Sheep were assigned to standard of care [SOC, Lactated Ringer's solution, cefazolin (1 g/L), bacitracin (50,000 U/L), 4°C storage] or MOPS [proprietary media, 22-25°C storage]. Samples underwent weekly media changes. Chondrocyte viability was assessed using Calcein AM/Ethidium Homodimer and reported as percent live cells and viable cell density (VCD). Metabolism was evaluated with the Alamar blue assay and reported as Relative Fluorescent Units (RFU)/mg. Electromechanical properties were measured with the Arthro-BST, a device used to non-destructively compress cartilage and calculate a quantitative parameter (QP) that is inversely proportional to stiffness. Proteoglycan content was quantified using the dimethylmethylene blue assay of digested cartilage and distribution visualized by Safranin-O/Fast Green staining of histological sections. A two-way ANOVA and Tukey's post hoc were performed. Compared to controls, MOPS samples had fewer live cells (p=0.0002) and lower VCD (p=0.0004) after 56 days of storage, while SOC samples had fewer live cells (p=0.0004, 28 days; p=0.0002, 56 days) and lower VCD (p=0.0002, 28 days; p=0.0001, 56 days) after both 28 and 56 days (Table 1). At 14 days, the percentage of viable cells in SOC samples were statistically the same as controls but VCD was lower (p=0.0197). Cell metabolism in MOPS samples remained the same over the study duration but SOC had lower RFU/mg after 28 (p=0.0005) and 56 (p=0.0001) days in storage compared to controls. These data show that MOPS maintained viability up to 28 days yet metabolism was sustained for 56 days, suggesting that the conditions provided by MOPS storage allowed fewer cells to achieve the same metabolic levels as fresh cartilage. Electromechanical QP measurements revealed no differences between storage methods at any individual time point. QP data could not be used to interpret changes over time because a mix of medial and lateral condyles were used and they have intrinsically different properties. Proteoglycan content in MOPS samples remained the same over time but SOC was significantly lower after 56 days (p=0.0086) compared to controls. Safranin-O/Fast Green showed proteoglycan diminished gradually beginning at the articular surface and progressing towards bone in SOC samples, while MOPS maintained proteoglycan over the study duration (Figure 1). MOPS exhibited superior viability, metabolic activity and proteoglycan retention compared to SOC, but did not maintain viability for 56 days. Elucidating the effects of prolonged MOPS storage on cartilage properties supports efforts to increase the supply of fresh osteochondral allografts for clinical use. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 87 - 87
22 Nov 2024
Glehr M Smolle M Murtezai H Amerstorfer F Hörlesberger N Leitner L Klim S Hauer G Leithner A
Full Access

Abstract. Background. The aim of the present experimental study was to analyse vancomycin elution kinetics of nine bone fillers used in orthopaedic and trauma surgery over 42 consecutive days. Methods. Two allograft bone chips (carriers 1 and 2), a calcium-sulfate matrix (carrier 3), a hydroxyapatite/calcium-sulphate composite (carrier 4), four bone cements (carriers 5-8) and a pure tricalcium phosphate matrix (carrier 9), either already contained vancomycin, or were mixed with it following manufacturer's recommendations. Over 42 days, half of elution medium was substituted by the same amount of PBS at 9 distinct time points. Vancomycin concentration in obtained samples were measured with a kinetic microparticle immunoassay, and masses consecutively calculated. To enhance comparability between carriers analysed, vancomycin mass released related to overall mass within each probe was determined. Notably, elution kinetics of carriers 1 to 4 have been published previously. Results. All carriers initially released high vancomycin masses, followed by constant reduction later into the experiment. Mean initial vancomycin masses released after 4 hours were highest for carriers 1 (337.7 ± 76.2 mg), 9 (68.4 ± 4.9 mg), and 2 (49.0 ± 54.6 mg). From prefinal (35 days) to last measurement (42 days) carriers 2 (8.6 ± 4.8 mg), 1 (2.4 ± 1.0 mg), and 5 (0.1 ± 0.1 mg) had released highest vancomycin masses. Notably, all five bone cements tested only released a small percental amount of their total mass up to the last measurement (42 days; 2.1% – 9.3%), whilst allografts and resorbable synthetic bone fillers discarded high percental values (22.5% – 79.2%). Conclusions. Elution kinetics differ between 9 antibiotic-loaded bone fillers, with high vancomycin masses released by allografts and resorbable bone fillers over time. Transferred to clinical practice, these may be favoured over bone cements in case prolonged and high antibiotic release is warranted rather than mechanical stability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 65 - 65
1 Dec 2022
Rosario R Coleman R Arruda E Grant J
Full Access

The goal of this study was to identify the effect of mismatches in the subchondral bone surface at the native:graft interface on cartilage tissue deformation in human patellar osteochondral allografts (OCA). Hypothesis: large mismatches in the subchondral bone surface will result in higher stresses in the overlying and surrounding cartilage, potentially increasing the risk of graft failure. Nano-CT scans of ten 16mm diameter cadaveric patellar OCA transplants were used to develop simplified and 3D finite element (FE) models to quantify the effect of mismatches in the subchondral bone surface. The simplified model consisted of a cylindrical plug with a 16 mm diameter (graft) and a washer with a 16 mm inner diameter and 36 mm outer diameter (surrounding native cartilage). The thickness of the graft cartilage was varied from 0.33x the thickness of native cartilage (proud graft subchondral bone) to 3x the thickness of native cartilage (sunken graft subchondral bone; Fig. 1). The thickness of the native cartilage was set to 2 mm. The surface of the cartilage in the graft was matched to the surrounding native cartilage. A 1 MPa pressure was applied to the fixed patellar cartilage surface. Scans were segmented using Dragonfly and meshed using HyperMesh. FE simulations were conducted in Abaqus 2019. The simplified model demonstrated that a high stress region occurred in the cartilage at the sharp bony edge between the graft and native subchondral bone, localized to the region with thinner cartilage. A 20% increase in applied pressure occurs up to 50μm away from the graft edge (primarily in the graft cartilage) for grafts with proud subchondral bone but varies little based on the graft cartilage thickness. For grafts with sunken subchondral bone, the size of the high stress region decreases as the difference between graft cartilage and native cartilage thickness decreases (Fig. 2-4), with a 200 μm high stress region occurring when graft cartilage was 3x thicker than native cartilage (i.e., greater graft cartilage thickness produces larger areas of stress in the surrounding native cartilage). The 3D models reproduced the key features demonstrated in the simplified model. Larger differences between native and graft cartilage thickness cause larger high stress regions. Differences between the 3D and simplified models are caused by heterogeneous cartilage surface curvature and thickness. Simplified and 3D FE analysis confirmed our hypothesis that greater cartilage thickness mismatches resulted in higher cartilage stresses for sunken subchondral bone. Unexpectedly, cartilage stresses were independent of the cartilage thickness mismatch for proud subchondral bone. These FE findings did not account for tissue remodeling, patient variability in tissue mechanical properties, or complex tissue loading. In vivo experiments with full-thickness strain measurements should be conducted to confirm these findings. Mismatches in the subchondral bone can therefore produce stress increases large enough to cause local chondrocyte death near the subchondral surface. These stress increases can be reduced by (a) reducing the difference in thickness between graft and native cartilage or (b) using a graft with cartilage that is thinner than the native cartilage. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 76 - 76
1 Jan 2016
Cho YJ Hur D Chun YS Rhyu KH
Full Access

Purpose. Cementless cup with structural allograft is one of option for acetabular revision in the cases which has severe bone loss. This study was performed to verify that the structural allograft with cementless cup could be one of good options for revision of acetabular cup with severe bone defect and to verify that the allograft resorption affect the stability of cementless acetabular cup. Materials and Methods. We reviewed 25 cases of 25 patients who underwent acetabular cup rvision using cementless porous coated hemispherical cup with structural allograft from May 1992 to July 2011 July 2011. There were nine males and sixteen females with an average age of 50.0 years. The average follow-up period was 76.7(28∼212) months. The clinical evaluation was performed using Harris Hip Score(HHS) and UCLA activity score. Radiologically, the degree of resorption of grafted bone, incorporation of allograft bone with normal bone, osteolysis and cup loosening were evaluated. Results. Clinically, the average Harris hip score was improved from 54 preoperatively to 93.4 at the last follow-up. The average UCLA activity score was also improved from 4.3 preoperatively to 6.4 at the last follow-up. Radiologically, the incorporation of allograft was accomplished in 11.4 months and the resorption of grafted bone was noted in 3 cases(12%), but the allograft resorption had not progressed to moderate degree even in long term follow-up. There was no cup loosening and average survivor rate was 100% in 6 years. There was no infection, allograft nonunion, osteolysis. Conclusion. Cementless cup with structural allograft in acetabular cup reconstruction can provide excellent mi-term results in both clinical and radiological aspects. Structural allograft can provide strong mechanical support for the bone ingrowth of cementless cup. The clinical result of this study auggest that cementless cup with structural allograft can be a good option for acetabular cup revision with severe bone defect. Resorption of structural allograft rarely occurred, and the resorption of structural allograft does not affect stablility of cup even in long term follow-up


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 79 - 79
1 Apr 2018
Lee W Han C Yang I Park K
Full Access

Introduction. Reinforcement ring with allograft bone is commonly used for acetabular reconstruction of bone defects because it can achieve stable initial fixation of the prosthesis. It is not clear whether the allograft bone can function as a viable host bone and provide long-standing structural support. The purpose of this study was to assess to long-term survival of the reinforcement rings and allograft bone incorporation after acetabular revisions. Methods. We retrospectively reviewed 39 hips (37 patients) who underwent reconstruction of the acetabulum with a Ganz reinforcement ring and allograft bone in revision total hip arthroplasty. There were 18 females and 19 males with a mean age of 55.9 years (35–74 years). The minimum postoperative follow-up period was 10 years (10∼17 years). We assessed the acetabular bone defect using the Paprosky's classification. We determined the rates of loosening of the acetabular reconstructions, time to aseptic loosening, integration of the allograft bone, resorption of the allograft bone, and survival rate. Aseptic loosening of the acetabular component was defined as a change in the cup migration of more than 5 mm or a change in the inclination angle of more than 5° or breakage of the acetabular component at the time of the follow-up. Graft integration was defined as trabecular remodelling crossing the graft-host interface. Resorption of the allograft bone was classified as minor (<1/3), moderate (1/3–1/2) or severe (>1/2). Kaplan-Meier survivorship analysis was performed for aseptic loosening of the acetabular component. The results. The acetabular bone defects were classified as follows: 8 type II hips (4 type IIB, 4 type IIC), and 31 type III hips (17 type IIIA, 14 type IIIB). Fourteen (35.9%) of 39 hips was defined as aseptic loosening of an acetabular component. Loosening was more frequent in type IIIB (57.1%) than in type IIIA hips (29.4%). Mean time to aseptic loosening of the acetabular reconstructions was 6.3 years in type IIIA and from 5 years in type IIIB defects, respectively. Allograft bone incorporation was satisfactory in 66.7% of hips. There was minor bone resorption in 14.3% and moderate bone resorption in 10.2%. In 9 hips (23.1%), severe resorption of the allograft bone was observed and early component loosening was observed in these cases. The survival rate of acetabular component at 10 years of follow-up was 63.6% (95% confidence interval, 49–77%) with aseptic loosening as endpoints. Conclusions. The long-term survival rate of acetabular revision using the reinforcement ring and allograft bone in the reconstruction of severe acetabular bone defects was unsatisfactorily low due to loosening of acetabular components. Because of unfavorable graft incorporation into a host bone, an alternative component and structural support may be employed in the reconstruction of severe acetabular bone defects


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 36 - 36
1 Jan 2016
Hgiwara S Kishida S Nakamura J Omae T Miyamoto S
Full Access

Background. Revision hip arthroplasty for excessive bone loss because of osteolysis or infection is difficult theme. Bone grafting is essential technique for bone loss and need of allograft is increasing. Recently, many hospital bone banks are established in Japan. The aim of this study is investigate efficacy and safety of allograft in our hospital bone bank. Material and method. We evaluated management, result and complication of allografts retrieved from living donors in our institute. Result. All donors meet the criteria of Japanese Orthopaedic Association (JOA) guideline and gave fully informed written consent. We obtained 75 femoral head grafts that were retrieved during primary total hip arthroplasty under sterile operating theatre conditions. No donor had hepatitis B and C, human immunodeficiency (HIV), Human T-cell leukemia (HTLV-1) and Syphilis. After heat treatment, allograft was swabbed for cultures and stored in freezer at −80□. All cultures ware negative and proved before implantation. We used allograft in 27 revision hip arthroplasty. Six cases were femoral side and 21cases were acetabular side. At the minimum of 3 months follow-up, 1 fracture of acetablar and 1 superficial infection occurred. No allergic reaction happened. Conclusion. Our bone bank thoroughly managed based on JOA guideline was effective and safe. Careful follow-up is needed for long-term implant fixation and osteoinduction


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 427 - 431
1 Mar 2015
Wu C Hsieh P Fan Jiang J Shih H Chen C Hu C

Fresh-frozen allograft bone is frequently used in orthopaedic surgery. We investigated the incidence of allograft-related infection and analysed the outcomes of recipients of bacterial culture-positive allografts from our single-institute bone bank during bone transplantation. The fresh-frozen allografts were harvested in a strict sterile environment during total joint arthroplasty surgery and immediately stored in a freezer at -78º to -68º C after packing. Between January 2007 and December 2012, 2024 patients received 2083 allografts with a minimum of 12 months of follow-up. The overall allograft-associated infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts taken before implantation revealed 21 (1.0%) positive findings. The 21 recipients were given various antibiotics at the individual orthopaedic surgeon’s discretion. At the latest follow-up, none of these 21 recipients displayed clinical signs of infection following treatment. Based on these findings, we conclude that an incidental positive culture finding for allografts does not correlate with subsequent surgical site infection. Additional prolonged post-operative antibiotic therapy may not be necessary for recipients of fresh-frozen bone allograft with positive culture findings. Cite this article: Bone Joint J 2015;97-B:427–31


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure. From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure. The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01). Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 9 - 9
1 Apr 2018
Kweon S
Full Access

Purpose. To evaluate the radiographic long-term result of femoral revision hip arthroplasty using impacted cancellous allograft combined with cemented, collarless, polished and tapered stem. Materials and methods. Among 28 patients with impacted cancellous allograft with a cemented stem, 28 hips from 26 consecutive patients were analyzed retrospectively. The average patient age was 59 years. The follow-up period ranged 9 years 6 months to 14 years 5 months (mean, 12, 5 years). Radiographic parameters analyzed in this study included subsidence of the stem in the cement, subsidence of the cement mantle in the femur, bone remodeling of the femur, radiolucent line, and osteolysis. Results. Radiographic analysis showed very stable stem initially. 27 stems showed minimal subsidence (less than 5 mm) and 1 stem showed moderate subsidence (about 10 mm) in the cement. But there was no mechanical failure and subsidence at the composit-femur interface. Evidence of cortical and trabecular remodeling were observed in all cases. No radiolucent line or osteolysis were found in the follow-up period. There were 4 proximal femoral cracks and 1 distal femoral splitting during operation. Conclusion. The result of cemented stem revision with the use of impacted cancellous allograft was good long-terand femoral bone stock deficiency may be reconstructed successfully


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 174 - 174
1 Sep 2012
Rogers B Kuchinad R Garbedian S Backstein D Safir O Gross A
Full Access

Introduction. A deficient abductor mechanism leads to significant morbidity and few studies have been published describing methods for reconstruction or repair. This study reports the reconstruction of hip abductor deficiency using human allograft. Methods. All patients were identified as having deficient abductor mechanisms following total hip arthroplasty through radiographic assessment, MRI, clinical examination and intra-operative exploration. All patients underwent hip abductor reconstruction using a variety of human allografts including proximal humeral, tensor fascia lata, quadriceps and patellar tendon. The type of allograft reconstruction used was customized to each patient, all being attached to proximal femur, allograft bone adjacent to host bone, with cerclage wires. If a mid-substance muscle rupture was identified an allograft tendon to host tendon reconstruction was performed. Results. Allograft reconstruction was performed in 15 patients over 18 months. One patient had an abductor deficiency after a primary total hip. All patients had an abductor lurch gait and positive Trendelenburg test preoperatively. Manual muscle strength testing showed significant weakness with a mean MRC grade of 3+/5. Peri-trochanteric pain was cited as a significant complaint in > 80 % of patients. Proximal humeral allografts, with rotator cuff, were used in 8 patients, 5 had tensor fascia lata and the remainder had patella with attached tendon allograft. The majority of patients had a reduction in pain and 8/15 (53%) increased their abductor strength by almost a full grade. A reduced lurch was observed in 10 (66%) patients and one patient re-dislocated after a failed revision for instability. Conclusion. To our knowledge, this is the largest reported series of allograft reconstruction for a deficient abductor mechanism following hip arthroplasty. A viable solution is demonstrated, with promising early results for a difficult problem, utilizing a straightforward technique with low morbidity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 25 - 25
1 Oct 2022
Casali M Rani N Cucurnia I Filanti M Coco V Reale D Zarantonello P Musiani C Zaffagnini M Romagnoli M
Full Access

Aim. Aim of this monocentric, prospective study was to evaluate the safety, efficacy, clinical and radiographical results at 24-month follow-up (N = 6 patients) undergoing hip revision surgery with severe acetabular bone defects (Paprosky 2C-3A-3B) using a combination of a novel phase-pure betatricalciumphosphate - collagen 3D matrix with allograft bone chips. Method. Prospective follow-up of 6 consecutive patients, who underwent revision surgery of the acetabular component in presence of massive bone defects between April 2018 and July 2019. Indications for revision included mechanical loosening in 4 cases and history of hip infection in 2 cases. Acetabular deficiencies were evaluated radiographically and CT and classified according to the Paprosky classification. Initial diagnosis of the patients included osteoarthritis (N = 4), a traumatic fracture and a congenital hip dislocation. 5 patients underwent first revision surgery, 1 patient underwent a second revision surgery. Results. All patients were followed-up radiographically with a mean of 25,8 months. No complications were observed direct postoperatively. HHS improved significantly from 23.9 preoperatively to 81.5 at the last follow-up. 5 patients achieved a defined good result, and one patient achieved a fair result. No periprosthetic joint infection, no dislocations, no deep vein thrombosis, no vessel damage, and no complaint about limbs length discrepancy could be observed. Postoperative dysmetria was found to be + 0.2cm (0cm/+1.0cm) compared to the preoperative dysmetria of − 2.4 cm (+0.3cm/−5.7cm). Conclusions. Although used in severe acetabular bone defects, the novel phase-pure betatricalciumphosphate - collagen 3D matrixshowed complete resorption and replacement by newly formed bone, leading to a full implant integration at 24 months follow-up and thus represents a promising method with excellent bone regeneration capacities for complex cases, where synthetic bone grafting material is used in addition to autografts


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 124 - 124
1 May 2012
Ganeshalingam R Oliver R Musgrove T Yu Y
Full Access

The biological properties of morselised bone allograft treated with either a supercritical fluid process or low-dose (15 kGy) gamma irradiation were compared using radiological, histological and immunohistological techniques. The aims were to investigate any differences in the biological properties of supercritical fluid treated allograft and low-dose gamma irradiated allograft in-vivo. Rabbit allograft were cleaned of all soft tissue, cartilage and processed into ‘corticancellous crunch’ using a Noviomagus Bone Mill. Pooled samples were either gamma irradiated (15 kGy) or treated by NovaSterilis using super critical carbon dioxide. A well-reported tibial defect model in ten rabbits was used to examine the in vivo response of the different treatments at two and four weeks following surgery (n=5 per time point). Radiographic (x-ray, CT and micro CT), histology and immunohistochemistry was used to assess the in vivo response. Radiographic results revealed an initial response to the gamma-irradiated samples compared to SCF. Histology confirmed this reaction to be inflammatory in nature at two weeks that continued at four weeks for the gamma irradiated samples. In contrast, the SCF treated sample demonstrated new bone formation while the inflammatory reaction was muted compared to the gamma irradiated samples. Four week x-rays and histology confirmed new bone formation in both groups while the lack of significant inflammatory response in the SCF group was noted. Allograft sterilisation techniques do not result in the same initial response when evaluated in vivo. Removal of lipids and cellular debris following SCF treatment may influence the in vivo response. While both techniques can provide a sterile product, the in vivo response requires further investigation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 9 - 9
1 Nov 2019
Siddiqi RA Byrne P Mukherjee A Hafiz N
Full Access

The management of patients with massive irreparable rotator cuff tears (RCT) has traditionally proved challenging. This prospective study was undertaken with the aim to assess the overall functional outcome following the use of human dermal allograft in the reconstruction of massive irreparable RCT. 15 patients were included in the study, having a median age of 63 years. All patients underwent open reconstruction of massive irreparable RCT. None of the selected patients had evidence of significant gleno-humeral arthritis. All patients were evaluated pre- and post- operatively by the treating surgeon, and followed up for 12 months. The same physiotherapy protocol was prescribed for all patients. Initial and follow-up assessments were done at regular intervals using the Oxford and quick-DASH scoring systems. A very high patient satisfaction rate, with substantial improvement in pain and function was noted. There was substantial improvement in Oxford shoulder score from a mean of 23.3 to 8.7 (p<0.01), and a similar improvement in mean quick-DASH score from 50.3 to 23.0 (p<0.01). Of the 15 patients, 11 had an improvement of >10 in Oxford score, with these reporting a score of <10 after 12 months. None of the patients had any significant complications because of the surgery, and none had a deterioration in Oxford score from their pre-operative status. We found that Human dermal allograft is a very effective tool in the repair of massive irreparable RCT, with excellent follow-up results after one year


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 8 - 8
1 Jun 2012
Baldini A Manfredini L Mariani PC Barbanti B
Full Access

Extensor mechanism disruption in total knee arthroplasty (TKA) occurs infrequently but often requires surgical intervention. We compared two cohorts undergoing extensor mechanism allograft reconstruction, one group had an extensor mechanism rupture, and the other had a recurrent ankylosed knee. Thirteen consecutive patients with extensor mechanism disruption or ankylosis after TKA were treated. Two different types of extensor mechanism allografts were used: quadriceps tendon-patella-patella tendon-tibial tubercle, and Achilles tendon allograft(Fig1). Demographic factors, diagnosis at extensor failure, Knee Society clinical rating scores, radiographs, and patient satisfaction were recorded. The average time from extensor mechanism disruption to surgery was 6.6 months (range, 1-24 months). At a mean followup of 24 months (range, 6-46 months), all patients were community ambulators. None of the patients showed a postoperative extensor lag. Average postoperative maximum flexion was 97° (90-115°) for the ruptured group and 80° (75-90) for the ankylosed grup. All patients thought their functional status had improved, and 87% were satisfied with the results of the allograft reconstruction (Fig 2, 3, 4, 5). One patient had allograft failure due to recurrent infection after re-revision for sepsis. The total extensor mechanism allograft and Achilles tendon allograft both were successful in the treatment of the failed extensor mechanism and showed promising results for the treatment of the ankylosed knee


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 60 - 60
1 May 2014
Callaghan J
Full Access

Allograft materials have been the mainstay in addressing bone deficiencies in knee and hip replacement and revision surgery for decades because of the associated donor site morbidity of autografts. Bone graft substitutes have been developed to address allograft issues including potential contamination, disease transmission, and availability. Although non-autogenous products have no osteogenic potential, they do have a variable degree of osteoinductive and osteoconductive properties. Unfortunately, there are limited reports regarding use of bone graft substitutes for use in total hip and knee arthroplasty. Bone graft substitutes have most frequently been used as an “extender”, in combination with morsellised allograft, to fill cavitary defects. Incorporation of this bone graft substitute and morsellised allograft combination appears to occur incompletely. Stable implant fixation appears to be a prerequisite for incorporation of bone graft substitutes, as these cannot be relied upon for structural support. Although bone graft substitutes appear to perform satisfactorily as “fillers” for contained cavitary bone defects, ultraporous metal augments have become the preferred method of providing structural support for some defects. In view of their substantial cost, high quality clinical, radiographic and retrieval data regarding performance of bone graft substitutes is needed


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 37 - 37
1 Nov 2016
Gupta S Kafchinski L Gundle K Saidi K Griffin A Ferguson P Wunder J
Full Access

Biological reconstruction techniques after diaphyseal tumour resection have increased in popularity in recent years. High complication and failure rates have been reported with intercalary allografts, with recent studies questioning their role in limb-salvage surgery. We developed a technique in which large segment allografts are augmented with intramedullary cement and fixed using compression plating. The goal of this study was to evaluate the survivorship, complications and functional outcomes of these intercalary reconstructions. Forty-two patients who had reconstruction with an intercalary allograft following tumour resection between 1989 and 2010 were identified from our prospectively collected database. Allograft survival, local recurrence-free, disease-free and overall survival were assessed using the Kaplan-Meier method. Patient function was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The 23 women and 19 men had a mean age of 33 years (14–77). The most common diagnoses were osteosarcoma (n=16) and chondrosarcoma (n=9). There were 9 humerus, 18 femur and 15 tibia reconstructions. At a mean follow-up of 95 months (5–288), 31 patients were alive without disease, 10 were dead of disease and 1 was deceased of other causes. There were 4 local recurrences and 11 patients developed metastatic disease. 5-year local recurrence free survival was 92%, 5-year disease-free survival was 70% and overall survival was 75%. Fourteen of 42 patients (33%) experienced complications: 5 wound healing complications, 4 infections, 2 non-unions, 2 fractures and 1 nerve palsy. Four allografts (9.5%) were revised for complications and 2 (5%) for local recurrence. Mean allograft survival was 85 months (4–288). Mean time to union was 8.2 (3–36) months for the proximal osteotomy site and 8.1 (3–23) months for the distal osteotomy site. The mean score for MSTS 87 was 29.4 (+/− 4.4), MSTS 93 was 83.7 (+/−14.8) and TESS was 81.6 (+/−16.9). An intercalary allograft augmented with intramedullary cement and compression plate fixation provides a reliable and durable method of reconstruction after tumour resection. Complication rates are comparable to the literature and are associated with high levels of patient function and satisfaction


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 6 - 6
1 Jul 2016
Ajoy S Mahesh M RangaSwamy B
Full Access

Management of bone defects is a common surgical challenge encountered following any high energy trauma. Femur fractures with bone loss account for 22% of all the fractures with bone loss/defect, and 5% to 10% of distal femur fractures are open injuries. It was estimated in 2008, that, more than 4.5 million open fractures occur annually in India. In this retrospective study, patients who received bone allograft from our tissue bank between May 2012 and September 2015 were analysed. Of the 553 allografts issued, at that point in time, 26 were used in patients who underwent reconstruction for distal Femur fractures primarily. Fractures with defect or bone loss from 12 cc (1cm) to 144 cc (12cm) were treated with either Internal or External fixation and bone allograft. Morcellised cancellous, or a cortical strut, were used to fill or reconstruct the defect or void. The radiological outcome in terms of fracture union was assessed and Knee society score was used to assess the functional outcome. Complications such as non- union, infection, stiffness and need of revision or additional procedures were also assessed. Osseous consolidation was achieved in all the 26 patients with a Median time of 24 weeks (16 to 60). The Median Functional Knee Society Score was 80, indicating satisfactory functional outcome. Infection was noted in one patient, but it was not attributed to the allograft. Additional minor procedures like bone marrow infiltration, corticotomy for bone lengthening were required in 10 patients. Our studycomprises the largest group of patients treated primarily with Allograft to reconstruct or fill the void of bone loss encountered with distal Femur fracture. Reconstruction of massive bone defects, in patients of distal Femur fractures, with bone allograft, shows encouraging results. The surgeon can achieve the goal of restoring form and function of these difficult injuries in a single stage and the technique will provide the freedom to reconstruct the bony defect up to 150 cc (12 cm length) and recreate the anatomy to near normal. This allows for early mobilisation of patients and restoration of their daily routine at the earliest


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 16 - 16
1 Dec 2015
Hu C
Full Access

Fresh-frozen allograft bone is frequently used in orthopaedic surgery. We investigated the incidence of allograft-related infection and analysed the outcomes of recipients of bacterial culture-positive allografts from our single-institute bone bank during bone transplantation. The fresh-frozen allografts were harvested in a strict sterile environment during total joint arthroplasty surgery and immediately stored in a freezer at −78° to −68° C after packing. Between January 2007 and December 2012, 2024 patients received 2083 allografts with a minimum of 12 months of follow-up. The overall allograft-associated infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts taken before implantation revealed 21 (1.0%) positive findings. The 21 recipients were given various antibiotics at the individual orthopaedic surgeon's discretion. At the latest follow-up, none of these 21 recipients displayed clinical signs of infection following treatment. Based on these findings, we conclude that an incidental positive culture finding for allografts does not correlate with subsequent surgical site infection. Additional prolonged post-operative antibiotic therapy may not be necessary for recipients of fresh-frozen bone allograft with positive culture findings. Chang Gung Medical Foundation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 12 - 12
1 Nov 2016
Park S Salat P Banks K Willett T Grynpas M
Full Access

Structural bone allografts are a viable option in reconstructing massive bone defects in patients following musculoskeletal (MSK) tumour resection and revision hip/knee replacements. To decrease infection risk, bone allografts are often sterilised with gamma-irradiation, which consequently degrades the bone collagen connectivity and makes the bone brittle. Clinically, irradiated bone allografts fracture at rates twice that of fresh non-irradiated allografts. Our lab has developed a method that protects the bone collagen connectivity through ribose pre-treatment while still undergoing gamma-irradiation. Biomechanical testing of bone pretreated with our method provided 60–70% protection of toughness and 100% protection of strength otherwise lost with conventional irradiation. This study aimed to determine if the ribose-treated bone allografts are biocompatible with host bone. The New Zealand White rabbit (NZWr) radius segmental defect model was used, in which 15-mm critically-sized defects were created. Bone allografts were first harvested from the radial diaphysis of donor female NZWr, and treated to create 3 graft types: C=untreated controls, I=conventionally-irradiated (33 kGy), R=our ribose pretreated + irradiation method. Recipient female NZWr (n=24) were then evenly randomised into the 3 graft groups. Allografts were surgically fixed with a 0.8-mm Kirschner wire. Post-operative X-rays were taken at 2, 6, and 12 weeks, with bony healing assessed by a blinded MSK radiologist using an established radiographic scoring system. The reconstructed radii were retrieved at 12 weeks and analysed using bone histomorphometry and microCT. Kruskal-Wallis and Mann-Whitney tests were utilised to compare groups, with statistical significance when p<0.05. Radiographic analysis revealed no differences in periosteal reaction and degree of osteotomy site union between the groups at any time point. Less cortical remodeling was observed in R and I grafts compared to untreated controls at 6 weeks (p=0.004), but was no longer evident by 12 weeks. Radiographic union was achieved in all groups by 12 weeks. Histologic and microCT analysis further confirmed union at the graft-host bone interface, with the presence of mineralising callus and osteoid. Histomorphometry also showed the bridging external callus originated from host bone periosteum and a distinct cement line between allograft and host bone was present at the union site. Previous studies have shown that the presence of non-enzymatic glycation end products in bone can impair fracture healing. However, these studies investigated bony healing in the setting of diabetic states. Our findings showed that under normal conditions, ribose pretreated grafts healed at rates similar to controls via mechanisms also seen in retrieved human allografts clinically in use. These findings that grafts pretreated with our method are biocompatible with host bone in the rabbit help to further advance this technology for clinical trials