Introduction. Shoulder
To compare Radiostereometric Analysis (RSA) and subjective outcomes of Total Knee Arthroplasty (TKA) and Total Ankle Arthroplasty (TAA). Twenty-five patients were recruited to receive TKA (Zimmer, NexGen LPS Trabecular Metal Monoblock) and 20 patients were recruited to receive TAA (DePuy, Mobility). The tibial component of the TKA and the tibial component of the TAA were followed for two years with RSA with exams postoperatively at six, 12 and 24 months. At two years, inducible displacement RSA at the knee and ankle was also performed. RSA outcomes measured were translations in the anterior-posterior, medial-lateral and distal-proximal directions of both implants. SF-36 outcome questionnaires were completed preoperatively and at each RSA follow-up with the outcome being the mental component score (MCS) and physical component score (PCS). Analysis of variance statistical testing was used to compare RSA outcomes and subjective outcomes.Purpose
Method
Commercial C-arm fluoroscopes are routinely used to analyze human skeletal joints during motions such as deep knee bends, or chair rises. Such diagnostics are used to characterize pre and post operative
Conventional fluoroscopes are routinely used to analyze human skeletal joints during motions such as deep knee bends. Such diagnostics are used to characterize pre and post operative
Revision options for a failed Total ankle arthroplasty (TAA) have historically been limited to complex hindfoot fusions, bespoke ankle arthroplasty revision or amputation. The patient outcomes of these procedures has been felt to be poor. The introduction of the INBONE-II and INVISION ankle arthroplasty revision systems has created a range of revision arthroplasty options, with the possibility of improved patient outcomes. We aim to report on the early results of 20 sequential revision TAA. All patients undergoing revision TAA with INBONE-II or INVISION had prospective collection of pre-operative and post-operative MOx-FQ and EQ-5D scores. Between September 2013 and June 2019 23 patients underwent revision TAA with mean time from implantation of 35 months (6 to 74). Those with greater than 1 year follow-up had scores included. Other outcomes included radiographic assessment for loosening and revision. 13 patients had INBONE-II and 10 INVISION. None required revision at the time of review. Pre-operative MOx-FQ averaged 40.6 (13.4 pain, 21 walking, 6.2 social). Post-operative MOx-FQ averaged 17.4 (6.2 pain, 8.1 walking, 3.1 social). Average EQ-5D improved from 8 to 6.6 and average EQ-VAS from 60 to 80. On radiograph review one patient had radiolucent lines around their INBONE-II stem evident at 1 year. This had not progressed by 4 years total follow-up. Another patient had uncoupling of part of the stem of her INBONE-II but had not required revision. This was attributed to surgeon error. Revision TAA using the INBONE-II and INVISION systems shows promising early results relating to loosening and revision and good maintained improvement in MOx-FQ and EQ-5D scores. This provides further evidence that patients with a failed TAA can safely have revision rather than having to commit to complex ankle/hindfoot fusion. This provides surgeons with flexibility particularly in those patients with other hindfoot arthritis or arthrodesis.
Purpose. Introduce an Integrated Approach for Orthopedic-Sports Medicine Practice and Patient Care Management that. Is built around effective and efficient surgical techniques, and patient care management processes. Integrates Operations and Service Excellence best practices with patient care management processes. Integrates orthopedic care delivery between outpatient clinic, pre-surgery, surgery, inpatient, (acute care) and post acute care settings. Delivers exceptional clinical, patient satisfaction and financial outcomes as validated by independent national healthcare benchmarking organization. Helps position Ortho-Sports medicine services for strategic growth. Is replicable to develop Ortho-Sports Medicine Centers of Excellence. Presentation illustrates the ‘Ten Elements’ approach to implement the Ortho-Sports Medicine Centers of Excellence and demonstrate the effectiveness of the approach with an outcomes study from over 1000 total knee arthroplasty (TKA) procedures. During the presentation, the speakers would share the key clinical, patient satisfaction, and financial outcomes achieved by the implementation of the best practices defined in our ‘Ten Elements’ approach. All performance data elements are collected, validated and analyzed by an independent third party, national healthcare benchmarking company. During the presentation Dr. Bramlett would elaborate on the surgical protocol, and the key differentiating steps in procedure technique from traditional approach that significantly enhances procedure effectiveness, efficiency and lowers the patient complication rate as demonstrated by benchmarking data. Speakers would further present the key elements of Total Knee
In this RCT the primary aim was to assess whether a short (125mm) Exeter V40 stem offered an equivalent hip specific function compared to the standard (150mm) stem when used for cemented total hip arthroplasty (THA). Secondary aims were to evaluate health-related quality of life (HRQoL), patient satisfaction, stem height and alignment, radiographic loosening, and complications between the two stems. A prospective multicentre double-blind randomised control trial was conducted. During a 15-month period, 220 patients undergoing THA were randomised to either a standard (n=110) or short (n=110) stem Exeter. There were no significant (p≥0.065) differences in preoperative variables between the groups. Functional outcomes and radiographic assessment were undertaken at 1- and 2-years. There were no differences (p=0.428) in hip specific function according to the Oxford hip score at 1-year (primary endpoint) or at 2-years (p=0.767) between the groups. The short stem group had greater varus angulation (0.9 degrees, p=0.003) when compared to the standard group and were more likely (odds ratio 2.42, p=0.002) to have varus stem alignment beyond one standard deviation from the mean. There were no significant (p≥0.083) differences in the Forgotten joint scores, EuroQol-5-Dimension, EuroQol-VAS, Short form 12, patient satisfaction, complications, stem height or radiolucent zones at 1 or 2-years between the groups. The Exeter short stem offers equivalent hip specific function, HRQoL, patient satisfaction, and limb length when compared to the standard stem at 2-years post-operation. However, the short stem was associated with a greater rate of varus malalignment which may influence future implant survival.
Introduction: The level of femoral neck resection is important during THR. Intraoperative landmarks include the greater trochanteric tip, lesser trochanter and femoral head height. However, intraoperative identification can be difficult. It is possible to use callipers from the apex of the femoral head in the long axis of the femur but this produces geometrical error resulting in under resection. We describe a simple method that resects the posterior femoral head to allow uniplanar measurement with a ruler. Inclusion Criteria: Uncemented THR performed by the senior authors (MSB &
LV). Methods: Neck resection level was calculated from templated preoperative AP radiographs as the distance from the femoral head apex. After head dislocation via a posterior approach, the head is resected with an oscillating saw parallel to posterior neck in the coronal plane. A ruler is placed on the cut surface with a clip attached at the templated resection level and the level marked. Standard operative technique to insert prosthesis ensuring stability and leg length equalisation. Pre and postoperative AP radiography were compared to calculate accuracy. Results: 22 Uncemented THR’s, M:F = 10:12, Mean age = 54.5yrs (range 43–83yrs), Range of variation in resection level = −3 to +8mm, Mean (95%CI) of variation in resection level = +3.61mm (±0.26mm). Assuming 20% radiographic magnification = +2.95mm (±0.20mm). Discussion: Our results are comparable to other methods described in the literature and illustrate that this simple technique can accurately translate the templated neck resection level using standard
High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our centre showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: One: Use of highly porous shells in all cases. Two: Use of largest femoral head possible. Three: Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule. Four: Use of ceramic head with titanium sleeve in all cases. Five: Partial resection of pseudotumor adjacent to sciatic and femoral nerves. The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients We specifically looked at (1) complications including reoperations, (2) radiologic outcomes, and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p < 0 .05. Major complications occurred in 4 (8.3%) of 48 patients who had modified surgical technique, compared to 12 (38%) of 32 revisions prior to modification (p < 0 .05). Two hips of 48 (4.17%) endured dislocations in Group 1, compared to 9 of 32 (28%) in Group 2 (p < 0 .05). Four patients of 48 had repeat revision in Group 1: 2 for recurrence of pseudotumor, 1 for dislocation, and 1 for infection, compared to 6 patients who had 7 repeat revisions of 32 patients in Group 2: 3 for acetabular loosening, 3 for dislocation, and 1 for recurrence of pseudotumor (p=0.1). None of 48 revisions in Group 1 had acetabular loosening, compared to 4 of 32 in Group 2 (p=0.02). Two patients had nerve injury in Group 2, compared to none in Group 1 (p=0.16). The mean WOMAC pain score was 87.1 of 100 and the function score was 88.4 of 100 in Group 1, compared to a mean WOMAC pain score of 78 of 100 (p=0.6) and a function score of 83 of 100 in Group 2 (p=0.8). Modification of the surgical techniques described in the introduction has resulted in a significant decrease in complications in revision of large head MOM total hips. We continue to use this protocol and recommend it for these difficult cases.
Decreasing tissue damage and recovery time, while improving quality of life have been the focus of many approaches to total hip arthroplasty (THA). In this study, we compared two approaches, a tissue-sparing superior capsulotomy percutaneously assisted approach (SP) and the traditional posterior approach (TR), to address the question of whether the novel technique reduces tissue damage. The secondary aim of this study focused on the measurement technologies utilized to quantify the damage resulting from either SP or TR. Image J, BioQuant, and cellSens were the image analysis programs employed. Statistical validation and comparisons of results between all platforms were performed. Both hips of freshly frozen cadaveric specimens (n = 8) were surgically prepared for THA with random procedure performed on left or right hip. All selected specimens had no prior implantation of devices to ensure all observed muscle damage occurred from the surgical technique. Surgeons resected tissue and performed necessary procedural steps up to device implantation. No devices were implanted during the study, as the aim was to quantify the damage caused by the incision and resection. After completion of the surgery, an independent surgeon (IS), who was blinded as to which method was performed on the specimen, excised the muscles and inspected areas of interest Assessment of the tissue damage was executed using a midsubstance cross-sectional area technique, validated by prior studies. High-resolution images of demarcated muscles were used for quantitative analysis. Three blinded independent reviewers quantified damaged tissue. The results were used to detect if statistically significant differences were present between the two methods. Furthermore, an independent reviewer using SPSS statistical software also assessed inter-program and inter-rater reliability.Introduction
Methods
To assess the effectiveness of role of frozen section in revision arthroplasty. 21 patients with infected hip arthroplasties were operated in the form of one or two-staged revision hip arthroplasties. A frozen section was obtained intra-operatively and >5 PMN's/ HPF was considered as a positive indicator of infection. Fig 1 llustrating frozen section image. If the frozen section was reported negative (≤5 PMN's/HPF), the revision prosthesis was implanted after a thorough debridement and a wash. If the frozen section was reported as positive, after the debridement a non-articulating antibiotic loaded cement spacer was implanted for 8 weeks, supplemented with 3 weeks of intravenous antibiotics and 3 weeks of oral antibiotics. This was followed by an antibiotic free interval of 2 weeks. The patient was taken up for a revision surgery once the frozen section study was negative (≤5 PMN's/HPF). The patients were followed up for minimum of 1 year to a maximum of 2 years after the revision for any evidence of infection (assessed clinically and serologically, radiologically).Aim
Method
High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our center showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: 1. Use of highly porous shells in all cases 2. Use of largest femoral head possible 3. Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule 4. Use of ceramic head with titanium sleeve in all cases 5. Partial resection of pseudotumor adjacent to sciatic and femoral nerves. The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients We specifically looked at (1) complications including reoperations; (2) radiologic outcomes; and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p<0.05.Background
Questions/purposes
In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs. This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs. Method Comparison was made between four different implant designs: medial pivot (MP), two different types of cruciate retaining (CR1 and CR 2) and deep dish (DD). A cohort of 30 Medial Pivot (MP) knees were compared with matched patients from each of the other designs, 10 in each group. Patients were matched for age, body mass index and time to follow up. Clinical examination was carried out by an orthopaedic surgeon blinded to implant type, and sagittal stability was tested using a KT1000 knee arthrometer, applying 67N of force at 30˚ and 90˚.Introduction
Aim
With growing attention being paid to quality and cost effectiveness in healthcare, outcome evaluations are becoming increasingly important. This determination can be especially difficult in reverse shoulder arthroplasty (RSA) given the complex pathology and extensive disabilities in this patient population. Several different scoring systems have been developed and validated for use in various shoulder pathologies. The purpose of this study was to assess the use three outcome scores in a population of patients undergoing RSA. We aim to demonstrate the validity of three outcome scores in patients undergoing RSA, and to determine if one score or a combination of scores is superior to others. Using a database of patients treated with RSA, we assessed preoperative and postoperative Constant Scores, American Shoulder and Elbow Surgeons (ASES) scores, and subjective shoulder values (SSV) in 148 shoulders. The outcomes at each scoring period were described and the scores were compared to one another as well as to active range of motion using linear regression modeling.Purpose
Methods
Patient demographics were similar between both groups. There was no significant difference in intra-operative blood loss between both groups. The early post-operative blood loss and total blood loss were significantly less in the tranexamic acid group. This effect of tranexamic acid was more significant in females who showed a dose-related relationship between tranexamic acid dose and blood loss. Fewer patients in the tranexamic acid group required blood transfusion. There was no increased incidence of DVT in the tranexamic acid group. The use of a single pre-operative 1g bolus of tranexamic acid administered before surgery is a safe, cost-effective method of reducing post-operative blood loss following total hip arthroplasty. The effect is more significant in females at this dose.
The optimal goal for cup positioning in hip arthroplasty in individual patients is affected by many factors including surgical exposure, femoral anteversion, and pelvic tilt. Some navigation systems ignore pelvic tilt and are based strictly on the anterior pelvic plane while others incorporate pelvic tilt, as measured in the supine position on the operating table. Neither approach incorporates knowledge of preoperative spino-pelvic flexibility or predictions of the change in spino-pelvic attitude or flexibility following surgery. While prior studies have shown little change in pelvic tilt postoperatively, one recent study based on gait analysis, suggested that changes in pelvic tilt are not predictable. The current study aims to assess changes in pelvic tilt following surgery. 24 patients, 12 male and 12 female, underwent THA using CT-based navigation. Each patient had supine and standing AP pelvis radiographs both pre-operatively and at a minimum of 1 year post-operatively. Pelvic tilt on each radiograph was measured using a noncommercial two-dimensional/three-dimensional matching application. (HipMatch; Institut for Surgical Technology and Biomechanics, Bern, Switzerland). This software application uses a fully auto- mated registration procedure that can match the three- dimensional model of the preoperative CT with the projected pelvis on a postoperative radiograph. This method has been validated and for measurement of cup position for example showed a mean accuracy of 1.7° +/− 1.7° (rang-4.6° to 5.5°) in the coronal plane and 0.9° +/− 2.8° (rang-5.2° to 5.7°) in the sagittal plane compared with postoperative CT measurements. The software showed a good consistency with an intraclass correlation coefficient (ICC) for inclination of 0.96 (95% confidence interval [CI]: 0.93 to 0.98) and for anteversion of 0.95 (95% CI: 0.91 to 0.98). A good reproducibility and reliability for both inclination and anteversion was found with an ICC ranging from 0.95 to 0.99. No systematic errors in accuracy were detected with the Bland- Altman analysis. Using the HipMatch 2D/3D application, changes in pelvic tilt before and after surgery were assess in both the supine and standing positions.Introduction
Methods
Clinical outocome of revision total elbow arthroplasty(TEA) in rheumatoid arthritis(RA) patients were evaluated. Clinical outocome of revision TEA that underwent between 2005 and 2013 were evaluated. Causes of revision, implanted revised prosthesis, a clinical score (the Japanese Orthopaedic Association (JOA) elbow assessment score), the arc of motion and complications were investigated. Totally, 6 patients underwent revision TEA. The patients were females with a mean age of 60.4 years (range, 32 to 72).Purpose
Methods
Total shoulder arthroplasty is a well-tested procedure that offers pain relief and restores the joint function. However, failure rate is still high, and glenoid loosening is pointed as the main reason in orthopedic registers. In order to understand the principles of failure, the principal strain distributions after implantation with Comprehensive® Total Shoulder System of Biomet® were experimental and numerically studied to predict bone behavior. Fourth generation composite left humerus and scapula from Sawbones® were used. These were implanted with Comprehensive® Total Shoulder System (Biomet®) with a modular Hybrid® glenoid base and Regenerex® glenoid and placed in situ by an experienced surgeon. The structures were placed in order to simulate 90º abduction, including principal muscular actions. Muscle forces used were as follows: Deltoideus 300N, Infraspinatus 120N, Supraspinatus 90N, Subscapularis 225N. All bone structures were modeled considering cortical and the trabecular bone of the scapula. The components of prosthesis were placed in the same positions than those in the in vitro models. Geometries were meshed with tetrahedral linear elements, with material properties as follows: Elastic modulus of cortical bone equal to 16 GPa, elastic modulus of trabecular bone equal to 0.155 GPa, polyethylene equal to 1GPa and titanium equal to 110 GPa. The assumed Poisson's ratio was 0.3 in all except for polyethylene where we assumed a value of 0.4. The prosthesis was considered as glued to the adjacent bone. The finite element model was composed of 336 024 elements. At the glenoid cavity, the major influence of the strain distributions was observed at the posterior-superior region, in both cortical and trabecular bone structures. The system presents critical region around holes of fixation in glenoid component. At the trabecular bone, the maximum principal strains at the posterior-superior region ranged from 2250 µε to 3000 µε. While at the cortical bone, the maximum principal strains were 300 µε to 400 µε. The results observed evidence some critical regions of concern and the effect of implant in the bone strains mainly at the posterior-superior region of the glenoid cavity is pronounced. This indicates that this region is more affected by the implant if bone remodeling is a concern and it is due to the strain-shielding effect, which has been connected with loosening of the glenoid component.
Tranexamic Acid (TA) has been shown to reduce transfusion rates in Total Knee Replacement (TKR) without complication. In our unit it was added to our routine enhanced recovery protocol. No other changes were made to the protocol at this time and as such we sought to examine the effects of TA on wound complication and transfusion rate. All patients undergoing primary TKR over a 12 month period were identified. Notes and online records were reviewed to collate demographics, length of stay, use of TA, thromboprophylaxis, blood transfusion, wound complications and haemoglobin levels. All patients received a Columbus navigated TKR with a tourniquet. Only patients who received 14 days of Dalteparin for thromboprophylaxis were included. 124 patients were included, 72 receiving TA and 52 not. Mean age was 70. Four patients required a blood transfusion all of whom did not receive TA (p = 0.029). Mean change in Hb was 22 without TA and 21 with (p = 0.859). Mean length of stay was 6.83 days without Tranexamic Acid and 5.15 with (p < 0.001). 15% of patients (n=11) of the TA group had a wound complication, with 40% of patients (n=21) in the non TA group (p = 0.003). There was one ultrasound confirmed DVT (non TA group). No patients were diagnosed with pulmonary embolus. In our unit we have demonstrated a significantly lower transfusion rate, wound complication rate and length of stay, without any significant increase in thromboembolic disease with the use of TA in TKR.