Fractures of the distal humeral
Isolated talonavicular arthrodesis is a common procedure particularly for posttraumatic arthritis and rheumatoid arthritis. Two surgical approaches are commonly used: the medial and the dorsal approach. It is recognized that access to the lateral aspect of the talonavicular joint can be limited when using the medial approach and it is our experience that using the dorsal approach addresses this issue. We performed an anatomical study using cadaver specimens, to compare the amount of
Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final movement and strength were compared with those of the contralateral side. The final American Shoulder and Elbow Society score and the Disabilities of Arm, Shoulder and Hand and Short-Form 36 questionnaires were compared with those provided by the patient on the day of the injury. Radiographs and CT scans with three-dimensional reconstruction were obtained in all patients. The pattern of the fracture and the displacement of individual fragments were analysed and correlated with the final outcome. There were two cases of nonunion and six of avascular necrosis. The majority of the fractures (84 patients; 90%) followed one of the following four patterns: posteromedial (varus) impaction in 50 patients (54%), lateral (valgus) impaction in 13 (14%), isolated greater tuberosity in 15 (16%), and anteromedial impaction fracture in six (6%). Head orientation, impaction of the surgical neck and displacement of the tuberosity correlated strongly with the outcome. In fractures with posteromedial impaction, a poor outcome was noted as the
A total of 20 patients with a depressed fracture
of the lateral tibial plateau (Schatzker II or III) who would undergo open
reduction and internal fixation were randomised to have the metaphyseal
void in the bone filled with either porous titanium granules or
autograft bone. Radiographs were undertaken within one week, after
six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint
surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower
(p <
0.001) and the operating time less (p <
0.002) when titanium
granules were used. The indication is that it is therefore beneficial to use porous
titanium granules than autograft bone to fill the void created by
reducing a depressed fracture of the lateral tibial plateau. There
is no donor site morbidity, the operating time is shorter and the
risk of recurrent depression of the
Surgical release of the elbow was performed in 27 patients with post-traumatic stiffness at a mean of 14.5 months after the initial injury. The outcome was related to whether there had been heterotopic ossification, which had occurred in 18 elbows and to whether, if there had been a fracture, it had involved the
Coronal plane fractures of the posterior femoral
condyle, also known as Hoffa fractures, are rare. Lateral fractures are
three times more common than medial fractures, although the reason
for this is not clear. The exact mechanism of injury is likely to
be a vertical shear force on the posterior femoral condyle with
varying degrees of knee flexion. These fractures are commonly associated
with high-energy trauma and are a diagnostic and surgical challenge. Hoffa
fractures are often associated with inter- or supracondylar distal
femoral fractures and CT scans are useful in delineating the coronal
shear component, which can easily be missed. There are few recommendations
in the literature regarding the surgical approach and methods of
fixation that may be used for this injury. Non-operative treatment
has been associated with poor outcomes. The goals of treatment are
anatomical reduction of the
This study compared the quality of reduction
and complication rate when using a standard ilioinguinal approach and
the new pararectus approach when treating acetabular fractures surgically.
All acetabular fractures that underwent fixation using either approach
between February 2005 and September 2014 were retrospectively reviewed
and the demographics of the patients, the surgical details and complications
were recorded. . A total of 100 patients (69 men, 31 women; mean age 57 years,
18 to 93) who were consecutively treated were included for analysis.
The quality of reduction was assessed using standardised measurement
of the gaps and steps in the
A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders’ type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the
Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest. A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).Aims
Methods
The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.Aims
Methods
Introduction:. Bicondylar tibial plateau fractures are serious periarticular injuries. We investigated outcomes in injuries managed with Ilizarov external fixators. Methods:. We retrospectively reviewed bicondylar tibial plateau fractures treated with Ilizarov fixators in a major trauma centre from 2008–2012. Radiological parameters were measured from standardised weight-bearing radiographs. A subset (n=34) had patient-related outcome measures. Results:. Of 80 injuries, all fractures united. Two developed septic arthritis and one osteomyelitis. 76.3% were graded a good-excellent outcome (Rasmussen radiological score). 30.3% had evidence of osteoarthritis (Kellgren Lawrence>1). Neither parameter correlated significantly with lower functional scores. Referrals from neighbouring hospitals had longer times to surgery, which associated with increased condylar widening (p=0.0214) and posterior tibial slope (p=0.0332). Risk of developing osteoarthritis correlated with lower joint line congruency angle (JLCA) (p=0.0017) and increased articular step-off (p=0.0008) on initial radiographs. 3 patients have progressed to total knee arthroplasty. Discussion and Conclusion:. This is the largest study of bicondylar tibial plateau fractures treated by Ilizarov fixation. Rates of septic arthritis and osteomyelitis compare with previously reported rates, with no cases of non-union. Over 76% achieved good-excellent radiological outcome, compared with 63–96% in studies of internal fixation. Achieving normal JLCA and smooth
Background. The usefulness of arthroscopic reduction for the intra-articular fracture of the distal radius has been reported, although it is technically difficult. Hypothesis. Our hypothesis is that the reduction using the external fixator is useful as equivalent to the arthroscopic reduction for the intra-articular fracture of the distal radius fracture in the fixation with the volar locking plate. Materials & Methods. The surgery was performed in both methods randomly for 40 patients; average age 64(24 to 92) years, 11 male, 29 female. Image evaluations were performed at 24 weeks after surgery. Ulnar variance, Radial inclination, Volar tilt in the X-ray image, and gap and step in the computed tomogram were evaluated. Clinical evaluation was performed at 6, 12, 24 weeks after surgery. Objective evaluations were ranges of motion and grip strength. Subjective evaluations were disabilities of the arm, shoulder, and hand (DASH). Results. The results of image and objective evaluation had no significant difference between the two groups. DASH in arthroscopic group was significantly inferior at 24 weeks because of minor complications. Discussion & Conclusion. The external fixator and the arthroscopy are equally valuable in reduction of
Magnetic resonance imaging (MRI) validation of a novel method of assessing Distal Radial Fracture (DRF) reduction using the hypothesised constant relationship between the dorsal radial cortex (DC) and the superior pole of the lunate (SL). MRI scans of 28 normal wrists were examined. Scans included the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius
Intro. Distal radial fractures are a commonly encountered fracture & anatomical reduction is the standard. Dorsal angulation is the traditional method of assessment but is inaccurate in rotated lateral xrays. Previously a relationship has been demonstrated between the dorsal cortex (DC) of the radius & the superior pole of the lunate (SL) & its sensitivity for assessing dorsal angulation & translation. Hypothesis. A constant anatomical relationship maintained between the DC and the SL when rotated up to 30 degrees from standard lateral?. Methods. MRI scans of 28 wrists including the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius
The aim of this study was to document both the short and long term outcome of isolated displaced olecranon fractures treated with primary non-operative intervention. We identified from our prospective trauma database all patients who were managed non-operatively for a displaced olecranon fracture over a 13-year period. Inclusion criteria included all isolated fractures of the olecranon with >2 mm displacement of the
Introduction. While clinically successful for decades, CR TKA is persistently compromised by inconsistent PCL function. Problems of mid-flexion instability, incomplete knee flexion, erratic kinematic behavior and posterior instability, not seen with PS devices, raise concerns about the consistency of the technique, and the devices used. Most TKA systems offer at least 2 different geometries of tibial inserts to address this clinical problem. We hypothesize these problems are a result of compromise of PCL anatomy. To avoid compromise to the PCL 3 steps are required: 1) The slope of tibial resection must be less than 5°; 2) the depth of tibial resection must be based off the insertion footprint of the PCL, not the deficiencies of the tibial
Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.Aims
Methods
Introduction. A tibial insert with choices in size, thickness, and posterior slope is proposed to improve ligament balancing in total knee arthroplasty. However, increasing posterior slope, or the angle between the distal and proximal insert surfaces, will redistribute ultra-high molecular weight polyethylene (UHMWPE) thickness in the sagittal plane, potentially affecting wear. This study used in-vitro testing to compare wear for a standard cruciate-retaining tibial insert (STD) and a corresponding 6° sloped insert (SLP), both manufactured from direct-compression molded (DCM) UHMWPE. Our hypothesis was slope variation would have no significant effect on wear. Methods. Two of each insert (STD and SLP) were tested on an Instron-Stanmore knee simulator with a force-control regime. The gait cycle and other settings followed ISO 14243-1 and -2, except for reference positions. The STD insert was tilted 6° more than the SLP insert to level the
Heterotopic ossification (HO) of the hip after injury to the central nervous system can lead to joint ankylosis. Surgery is usually delayed to avoid recurrence, even if the functional status is affected. We report a consecutive series of patients with HO of the hip after injury to the central nervous system who required surgery in a single, specialised tertiary referral unit. As was usual practice, they all underwent CT to determine the location of the HO and to evaluate the density of the femoral head and
Type-I fractures of the lateral tibial plateau were simulated by osteotomy in 18 pairs of unembalmed cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws plus an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and