The risk to patients and healthcare workers of resuming elective orthopaedic surgery following the peak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been difficult to quantify. This has prompted governing bodies to adopt a cautious approach that may be impractical and financially unsustainable. The lack of evidence has made it impossible for surgeons to give patients an informed perspective of the consequences of elective surgery in the presence of SARS-CoV-2. This study aims to determine, for the UK population, the probability of a patient being admitted with an undetected SARS-CoV-2 infection and their resulting risk of death; taking into consideration the current disease prevalence, reverse transcription-polymerase chain reaction (RT-PCR) testing, and preassessment pathway. The probability of SARS-CoV-2 infection with a false negative test was calculated using a lower-end RT-PCR sensitivity of 71%, specificity of 95%, and the UK disease prevalence of 0.24% reported in May 2020. Subsequently, a case fatality rate of 20.5% was applied as a worst-case scenario.Aims
Methods
Discoid meniscus (DM) is a congenital variant of the knee joint that involves morphological and structural deformation, with potential meniscal instability. The prevalence of the Discoid Lateral Meniscus (DLM) is higher among the Asians than among other races, and both knees are often involved. Meniscal pathology is widely prevalent in the adult population, secondary to acute trauma and chronic degeneration. The true prevalence in children remains unknown, as pathologies such as discoid menisci often go undiagnosed, or are only found incidentally. A torn or unstable discoid meniscus can present with symptoms of knee pain, a snapping or clicking sensation and/or a decrease in functional activity, although it is not known if a specific presentation is indicative of a torn DM. While simple radiographs may provide indirect signs of DLM, magnetic resonance imaging (MRI) and arthroscopy is essential for diagnosis and treatment planning.
A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for
Guidelines for the use of preoperative blood tests for elective surgery were established. However, there is less evidence and no guidelines regarding using these tests when a young, healthy patient undergoes minor orthopaedic trauma surgery. Bloodwork is often ordered routinely, regardless of medical history or the nature of the injury. We hypothesized that unnecessary blood work is requested for younger pre-operative patients, and their results will not change peri-operative management. This practice is not a judicious use of healthcare resources. This study aimed to evaluate the frequency, type, cost, and impact on clinical decisions if standard preoperative bloodwork was completed in healthy patients requiring surgical management of a minor fracture or dislocation. After the approval of our institutional ethics board, a retrospective chart review was conducted. Inclusion criteria were patients aged 18-60 years, who had an isolated minor orthopaedic trauma requiring outpatient surgery, who were American Society of Anesthesiologists (ASA) class 1. ASA class 1 is defined as “a normal healthy patient, without any clinically important comorbidity and without a clinically significant past/present medical history.” Data records from January 1, 2016, to December 31, 2018, were extracted from a provincial database (the Analytics Data Integration, Measurement and Reporting) for five hospitals. Data including demographics, surgical treatment, type and number of blood tests ordered, and ordering physician were collected. Any abnormal test results were checked to see whether they led to a change in patient management or related to a postoperative adverse event. Independent samples t-tests and Chi-square tests were used to compare the characteristics of patients who had preoperative bloodwork versus those who did not. The cost of preoperative blood work was estimated. During these two years, 627 patients met inclusion criteria, and 27% (n=168) of these patients had bloodwork completed pre-operatively, while only 34% (n=57) of these had one or more abnormal laboratory parameters. These abnormalities were minor and did not alter clinical management or result in repeated bloodwork peri-operatively. Patients who had bloodwork were significantly older (40.2 years) compared with patients without preoperative blood work (37.8 years; p=0.03), but there was no difference in sex between those who had bloodwork (53.4% male) and those who did not (51.4% male; p=0.63). The most common blood test ordered was a complete blood count, and the most commonly abnormal result was a mildly elevated white blood cell count (19%; n= 29). The most common patients to receive bloodwork were those with ankle (34%) and distal radius (34%) fractures. The bloodwork was primarily ordered by clinical associates (26%; n=46) and emergency department physicians (22%; n=38). Without considering lab personnel, consumables, and analysis time, the cost of this bloodwork was approximately $7685, an average of $45 per patient. Pre-operative bloodwork in young, healthy,
Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both
Introduction. Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (Exogen. TM. ) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using Exogen. TM. therapy for delayed fracture union in a district general hospital. Materials & Methods. This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed Exogen. TM. therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established
Introduction. In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated. Methods. All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge. Results. Overall, 100 children underwent surgery or interventional radiological procedures under GA between 20 March and 8 May 2020. There were 35 trauma cases, 20 urgent elective orthopaedic cases, two spinal emergency cases, 25 admissions for interventional radiology procedures, and 18 tumour cases. 78% of trauma cases were performed within 24 hours of referral. In the 97% who responded at two weeks following discharge, there were no cases of symptomatic COVID-19 in any patient or member of their households. Conclusion. Despite the extensive restructuring of services and the widespread concerns over the surgical and anaesthetic management of paediatric patients during this period, we treated 100
Aims. Metal-on-metal total hip replacements (MoM THRs) are frequently revised. However, there is a paucity of data on clinical outcomes following revision surgery in this cohort. We report on outcomes from the largest consecutive series of revisions from MoM THRs and consider pre-revision factors which were prognostic for functional outcome. Materials and Methods. A single-centre consecutive series of revisions from MoM THRs performed during 2006–2015 was identified through a prospectively maintained, purpose-built joint registry. The cohort was subsequently divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score (OHS)). Secondary outcomes were complication data, pre- and post-revision serum metal ions and modified Oxford classification of pre-revision magnetic resonance imaging (MRI). In addition, the study data along with demographic data was interrogated for prognostic factors informing on post-revision functional outcome. Results. 180 revisions in 163 patients were identified at a median follow-up of 5.48 (2–11.7) years. There were 152 (84.4%) in the symptomatic subgroup and 28 (15.6%) in the asymptomatic group. Overall median OHS improved from 29 to 37 with revision (P<0.001). Symptomatic patients experienced greater functional benefit (DOHS 6.5 vs. 1.4, p=0.012) compared to
This study addresses a crucial gap in the knowledge of normative spinal growth in children. The objective of this study is to provide detailed and accurate 3D reference values for global and segmental spinal dimensions in healthy children under the age of 11. Radiographic spine examinations of healthy children conducted to rule out scoliosis were reviewed in four scoliosis referral centers in North America. All consecutive children aged three to eleven years old with EOS biplanar good quality x-rays, but without diagnosed growth-affecting pathologies, were included. Postero-Anterior and Lateral calibrated x-rays were used for spine 3D reconstruction and computation of vertebral body height and spine length. Median and interquartile range were calculated from cross-sectional data. Smooth centiles growth curves for 3D True Spinal Length (3DTSL) between T1 and S1, as well as for mid-vertebral heights of T5, T12 and L3, where fit and calibrated from data using the Lambda-Mu-Sigma method (GAMLSS package for R). This method automatically selects the best performing distribution from a familly of choices. Tables of centiles were then predicted from the computed models for selected ages. A total of 638 full spine examinations from
Little is known about the relationship between head-neck corrosion and its effect on the periprosthetic tissues and distant organs of patients hosting well-functioning devices. The purpose of this study was to investigate in postmortem retrieved specimens the degree and type of taper damage, and the corresponding histologic responses in periprosthetic tissues and distant organs. Fifty postmortem THRs (34 primaries, 16 revisions) retrieved after 0.5 to 26 years were analyzed. Forty-three implants had a CoCrMo stem and seven had a Ti6Al4V stem. All heads were CoCrMo and articulated against polyethylene cups (19 XLPE, 31 UHMWPE). H&E sections of joint pseudocapsules, liver, spleen, kidneys and lymph nodes were graded 1–4 for the intensity of various inflammatory cell infiltrates and tissue characteristics. Corrosion damage of the taper surfaces was assessed using visual scoring and quantitated with an optical coordinate measuring machine. SEM analysis was used to determine the acting corrosion mode. Polyethylene wear was assessed optically. The majority of tapers had minimal to mild damage characterized by local plastic deformation of machining line peaks. Imprinting of the stem topography onto the head taper surface was observed in 18 cases. Column damage on the head taper surface occurred in three cases. All taper surfaces scored moderate or severe exhibited local damage features of fretting and/or pitting corrosion. Moderate or severe corrosion of the head and/or trunnion was present in nine hips. In one
Purpose. There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31
All patients with a MOM THR implanted at our unit were recalled for clinical examination, Oxford hip score, radiographs, MARS MRI and cobalt/chromium ion levels. Patients were sub-classified, determining further follow up: a regular screening programme or referral to a revision arthroplasty surgeon. We identified 299 MOM THR's. 59 patients reported a recent deterioration in symptoms. 67 had an abnormal x-ray. 232 hips underwent MARS MRI: 66 showed mild MOM disease, 31 moderate MOM disease, 17 severe MOM disease. 117 had a substantial fluid collection around the hip. Serum cobalt/chromium ions were raised in 135 patients. 46 had one or both above 7 ppb. 148 THR's were referred to a revision surgeon. 21 have been revised and 14 are awaiting revision. In total 64 hips have been revised. 13 were histologically proven ALVAL, 19 had clinical findings of ALVAL (not histologically confirmed), and 1 non-specific reaction to metal wear. 53
Aims. To describe the incidence of adverse clinical outcomes related to COVID-19 infection following corticosteroid injections (CSI) during the COVID-19 pandemic. To describe the incidence of positive SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) testing, positive SARS-COV2 IgG antibody testing or positive imaging findings following CSI at our institution during the COVID-19 pandemic. Methods. A retrospective observational study was undertaken of consecutive patients who had CSI in our local hospitals between 1 February and 30June 2020. Electronic patient medical records (EPR) and radiology information system (RIS) database were reviewed. SARS-CoV-2 RT-PCR testing, SARS-COV2 IgG antibody testing, radiological investigations, patient management, and clinical outcomes were recorded. Lung findings were categorized according to the British Society of Thoracic Imaging (BSTI) guidelines. Reference was made to the incidence of lab-confirmed COVID-19 cases in our region. Results. Overall, 1,656 lab-confirmed COVID-19 cases were identified in our upper tier local authority (UTLA), a rate of 306.6 per 100,000, as of 30June 2020. A total of 504 CSI injections were performed on 443 patients between 1 February and 30June 2020. A total of 11 RT-PCR tests were performed on nine patients (2% of those who had CSI), all of which were negative for SARS-CoV-2 RNA, and five patients (1.1%) received an SARS-CoV-2 IgG antibody test, of which 2 (0.5%) were positive consistent with prior COVID-19 infection, however both
Introduction. Pseudotumors have been reported following metal-on-metal total hip arthroplasty (THA); however, the natural history and longitudinal imaging findings of pseudotumors have yet to be fully analyzed. Our hypothesis was that pseudotumor size might change over time following metal-on-metal THA. This hypothesis was studied longitudinally using magnetic resonance imaging (MRI). Materials and Methods. Screening for pseudotumors was performed using MRI after large-diameter metal-on-metal THA. Initial MRI was conducted at a mean of 36 months postoperatively. Follow-up MRI was performed at a mean of 20 months after the detection of 24 pseudotumors in 20
INTRODUCTION. Lumbar total disc replacement (TDR) is an alternative treatment to avoid fusion related adverse events, specifically adjacent segment disease. New generation of elastomeric non-articulating devices have been developed to more effectively replicate the shock absorption and flexural stiffness of native disc. This study reports 5 years clinical and radiographic outcomes, range of motion and position of the center of rotation after a viscoelastic TDR. Material and methods. This prospective observational cohort study included 61 consecutive patients with monosegmental TDR. We selected patients with intermediate functional activity according to Baecke score. Hybrid constructs had been excluded. Only cases with complete clinical and radiological follow-up at 3, 6, 12, 24 and 60 months were included. Mean age at the time of surgery was 42.8 +7.7 years-old (27–60) and mean BMI was 24.2 kg/m² +3.4 (18–33). TDR level was L5-S1 in 39 cases and L4-L5 in 22 cases. The clinical evaluation was based on Visual Analog Scale (VAS) for pain, Oswestry Disability Index (ODI) score, Short Form-36 (SF36) including physical component summary (PCS) and mental component summary (MCS) and General Health Questionnaire GHQ28. The radiological outcomes were range of motion and position of the center of rotation at the index and the adjacent levels and the adjacent disc height changes. Results. There was a significant improvement in VAS (3.3±2.5 versus 6.6±1.7, p<0.001), in ODI (20±17.9 versus 51.2±14.6, p<0.001), GHQ28 (52.6±15.5 versus 64.2±15.6, p<0.001), SF 36 PCS (58.8±4.8 versus 32.4±3.4, p<0.001) and SF 36 MCS(60.7±6 versus 42.3±3.4, p<0.001). Additional surgeries were performed in 5 cases. 3 additional procedures were initially planified in the surgical program: one adjacent L3-L5 ligamentoplasty above a L5S1 TDR and two L5S1 TDR cases had additional laminectomies. Fusion at the index level was secondary performed in 2 L4L5 TDR cases but the secondary posterior fusion did not bring improvement. In the 56 remaining patients none experienced facet joint pain. One patient with sacroiliac pain needed local injections. Radiological outcomes were studied on 56 cases (exclusion of 5 cases with additional surgeries). The mean location centers of the index level and adjacent discs were comparable to those previously published in
Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2005 and 2014, 21 patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all-polyethylene cup was used. Pre-operative diagnosis was aseptic loosening (15 cemented and 6 uncemented). The femoral component was revised in 10 patients. Post-operative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete post-operative sciatic palsy. After a mean follow up of 47 months (13 to 128) none of the patients required re-revision of the acetabular component. One
Aim. Propionibacterium acnes (PA) is an important cause of shoulder prosthetic joint infections (SPJIs) for which the optimal treatment has not yet been determined. Rifampicin and Levofloxacin both showed not benefit in recent experimental models of PA-SPJIs. We describe herein the experience of five different medical French centers in order to assess factors associated with patient's outcome with special emphasize on antibiotic regimens. Method. A multicentric retrospective study was performed, on consecutive patients with PA – related SPJIs diagnosed on the basis of at least 2 or more positive cultures of either per-operative or joint aspiration and clinical history compatible with a PJI according to the current guidelines. All patients had surgical management, followed by systemic antibiotic therapy. Remission was defined as an
Introduction. Mechanically assisted crevice corrosion (MACC) in metal-on-polyethylene (MOP) total hip arthroplasty (THA) is of concern, but its prevalence, etiology and natural history are incompletely understood. Methods. From January 2003 to December 2012, 1356 consecutive THA surgeries using a titanium stem, cobalt chromium alloy femoral head, highly crosslinked polyethylene and a tantalum or titanium acetabular shell were performed. Patients were followed at 1 year, and 5 year intervals for surveillance, but also seen earlier if they had symptoms. Any patient with osteolysis or unexplained pain underwent exam, radiographs, CBC, ESR and CRP, as well as serum cobalt (Co) and chromium (Cr) level. MARS MRI was performed if the Co level was > 1 ppb. Results. Symptomatic MACC was present in 39/1356 patients (2.9%). Yearly MACC prevalence ranged from 0 % (0/139, 2005) to 9.9 % (16/162, 2009). 22/39 (56%) patients have undergone revision surgery, and 17/39 (44%) have opted for ongoing surveillance. Of the surveillance patients, serial serum metal ion levels appear to increase over time. Time of symptoms is correlated with tissue necrosis at time of revision. Conclusions. The prevalence of MACC in MOP hips is higher in this cross-sectional study than previously reported. The highest prevalence was found in 2009 with this vendor. Based on how common this finding is in symptomatic patients from 2009, we may consider asking
Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3B) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2006 and 2014, sixteen patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all polyethylene cup was used. Preoperative diagnosis was aseptic loosening (10 cemented and 6 non-cemented). The femoral component was revised in 9 patients. Postoperative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete postoperative sciatic palsy. After a mean follow up of 40 months (24 to 104) none of the patients required re-revision. One
The prevalence of pseudotumours in patients with large-head metal-on-metal (MOM) THA has been the subject of implant recalls and warnings from various regulatory agencies. To date, there is no consensus on whether ultrasound or MRI is superior for the detection and following the progression of pseudotumours. Ultrasound is relatively cheap but can be operator dependent. MARS MRI has the advantage of excellent visibility of the soft tissue. However, MRI comes at a marked increase cost and takes about twice as long to perform. At our institution, we prospectively compared ultrasound to MRI for pseudotumour detection in an asymptomatic cohort of patients with MOM THAs. We enrolled 40 patients with large-head MOM THAs in the study. The mean age was 54 years (range, 34–76 years). The mean time from surgery was 54 months (range, 40–81 months). There were 28 men and 12 women. All patients underwent ultrasound and MRI using slice encoding for metal artifact correction. The gold standard was defined as follows: if both ultrasound and MRI agreed, this was interpreted as concordant and the result was considered accurate. Ultrasound and MRI agreed in 37 of 40 patients (93%). The prevalence of pseudotumours was 31% (12 of 39) in our cohort. Twenty-three of 39 patients (59%) had completely normal tests and four (10%) had simple fluid collections. Ultrasound had a sensitivity of 100% and specificity of 96% while MRI had a sensitivity of 92% and specificity of 100%. Conclusions: A negative ultrasound rules out pseudotumour in