Advertisement for orthosearch.org.uk
Results 1 - 20 of 55
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1060 - 1066
1 Sep 2022
Jin X Gallego Luxan B Hanly M Pratt NL Harris I de Steiger R Graves SE Jorm L

Aims. The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA). Methods. This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC. Results. The mean 90-day revision rate for infection was 0.1% (0.1% to 0.2%) for TKA and 0.3% (0.1% to 0.5%) for THA. The mean 90-day PJI rates defined by T84.5 were 1.3% (1.1% to 1.7%) for TKA and 1.1% (0.8% to 1.3%) for THA. The mean 90-day PJI rates using the extended definition were 1.9% (1.5% to 2.2%) and 1.5% (1.3% to 1.7%) following TKA and THA, respectively. Conclusion. When reporting the revision arthroplasty for infection, the AOANJRR substantially underestimates the rate of PJI at 90 days. Using combinations of infection codes and PJI-related surgical procedure codes in linked hospital administrative databases could be an alternative way to monitor PJI rates. Cite this article: Bone Joint J 2022;104-B(9):1060–1066


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims. Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA. Methods. A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified. Results. The AOANJRR reported two revisions: one due to infection, and the second due to femoral component loosening. No revisions for dislocation were reported. One patient died with the prosthesis in situ. Kaplan-Meier survival rate was 99.1% (95% confidence interval 98.3 to 100) at 14 months (number at risk 104). Conclusion. In our cohort of patients undergoing primary THA with one or more factor associated with adverse SPM, DM bearings conferred stability at two years’ follow-up. Cite this article: Bone Joint J 2022;104-B(7):820–825


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 9 - 9
10 May 2024
Owen D
Full Access

Background. Increasing evidence suggests a link between the bearing surface used in total hip arthroplasty (THA) and the occurrence of infection. It is postulated that polyethylene has immunomodulatory effects and may influence bacterial function and survival, thereby impacting the development of periprosthetic joint infection (PJI). This study aimed to investigate the association between polyethylene type and revision surgery for PJI in THA using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). We hypothesized that the use of XLPE would demonstrate a statistically significant reduction in revision rates due to PJI compared to N-XLPE. Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) spanning September 1, 1999, to December 31, 2021, were used to compare the infection revision rates between THA using N-XLPE and XLPE. We calculated the Cumulative Percentage Revision rate (CPR) and Hazard Ratio (HR) while controlling for factors like age, sex, body mass index (BMI), American Society of Anesthesiologists’ (ASA) grade, and head size. Results. From the total 361,083 primary THAs, 26,827 used N-XLPE and 334,256 used XLPE. Excluding data from the first 6 months post-surgery, 220 revisions occurred in the N-XLPE group and 1,055 in the XLPE group for PJI. The HR for infection revision was significantly higher in N-XLPE compared to XLPE, at 1.64 (95% CI, 1.41–1.90, p<0.001). Conclusions. This analysis provides evidence of an association between N-XLPE and revision for infection in THA. We suspect that polyethylene wear particles contribute to the susceptibility of THA to PJI, resulting in a significantly higher risk of revision for infection in N-XLPE hips compared to those with XLPE. Level of Evidence. Therapeutic Level III


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims. The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Methods. Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined. Results. The AOANJRR identified 153 primary DFAs performed for native knee fractures in 151 patients during the study period, with 63.3% of these (n = 97) performed within the last five years. The median follow-up was 2.1 years (interquartile range 0.8 to 4.4). The patient population was 84.8% female (n = 128), with a mean age of 76.1 years (SD 11.9). The cumulative percent revision rate at three years was 10%. The most common reason for revision was loosening, followed by infection. Patient survival at one year was 87.5%, decreasing to 72.8% at three years postoperatively. Conclusion. The use of DFA to treat native knee fractures is increasing, with 63.3% of cases performed within the last five years. While long-term data are not available, the results of this study suggest that DFA may be a reasonable option for elderly patients with native knee fractures where fixation is not feasible, or for whom prolonged non-weightbearing may be detrimental. Cite this article: Bone Joint J 2022;104-B(7):894–901


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims. Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders. Patients and Methods. Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA. Results. Overall, THA was used in 23.7% of patients. THA was more frequently used over time, in younger patients, in healthier patients, in cases performed on weekdays (adjusted odds ratio (OR) 1.27; 95% confidence interval (CI) 1.14 to 1.41), in private hospitals (adjusted OR 4.34; 95% CI 3.94 to 4.79) and by surgeons whose hip arthroplasty practice has a relatively higher proportion of elective patients (adjusted OR 1.65; 95% CI 1.49 to 1.83). Conclusion. Practice variation exists in the proportion of FNF patients treated with THA due to variables other than patient factors. This may reflect variation in resources available and surgeon preference, and uncertainty regarding the relative indication


Bone & Joint Open
Vol. 3, Issue 5 | Pages 367 - 374
5 May 2022
Sinagra ZP Davis JS Lorimer M de Steiger RN Graves SE Yates P Manning L

Aims. National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its accuracy. We then applied these data to refine estimates of the total national burden of PJI. Methods. A total of 561 Australian cases of confirmed PJI were captured by a large, prospective observational study, and matched to data available for the same patients through the AOANJRR. Results. In all, 501 (89.3%) cases of PJI recruited to the prospective observational study were successfully matched with the AOANJRR database. Of these, 376 (75.0%) were captured by the registry, while 125 (25.0%) did not have a revision or reoperation for PJI recorded. In a multivariate logistic regression analysis, early (within 30 days of implantation) PJIs were less likely to be reported (adjusted odds ratio (OR) 0.56; 95% confidence interval (CI) 0.34 to 0.93; p = 0.020), while two-stage revision procedures were more likely to be reported as a PJI to the registry (OR 5.3 (95% CI 2.37 to 14.0); p ≤ 0.001) than debridement and implant retention or other surgical procedures. Based on this data, the true estimate of the incidence of PJI in Australia is up to 3,900 cases per year. Conclusion. In Australia, infection was not recorded as the indication for revision or reoperation in one-quarter of those with confirmed PJI. This is better than in other registries, but suggests that registry-captured estimates of the total national burden of PJI are underestimated by at least one-third. Inconsistent PJI reporting is multifactorial but could be improved by developing a nested PJI registry embedded within the national arthroplasty registry. Cite this article: Bone Jt Open 2022;3(5):367–373


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 56 - 56
10 Feb 2023
Vaotuua D O'Connor P Belford M Lewis P Hatton A McAuliffe M
Full Access

Deep infection is a devastating complication of total knee arthroplasty (TKA). This study aimed to determine if there was a relationship between surgeon volume and the incidence of revision for infection after primary TKA. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1 September 1999 to 31 December 2020 for primary TKA for osteoarthritis that were revised for infection. Surgeon volume was defined by the number of primary TKA procedures performed by the surgeon in the year the primary TKA was performed and grouped as <25, 25-49, 50-74, 75-99, >100 primary TKA procedures per year. Kaplan Meir estimates for cumulative percent revision (CPR) and Cox Proportional Hazard Ratios were performed to compare rates of revision for infection by surgeon volume, with sub-analyses for patella and polyethylene use, age <65 years and male gender. 5295 of 602,919 primary TKA for osteoarthritis were revised for infection. High volume surgeons (>100 TKA/year) had a significantly lower rate of revision for infection with a CPR at 1 and 17 years of 0.4% (95% CI 0.3, 0.4) and 1.5% (95% CI 1.2, 2.0), respectively, compared with 0.6% (95% CI 0.5, 0.7) and 2.1% (95% CI 1.8, 2.3), respectively, for low volume surgeons (<25 TKR/year). Differences between the high-volume group and the remaining groups remained when sub-analysis for age, gender, ASA, BMI, patella resurfacing and the use of cross-linked polyethylene (XLPE). High volume surgeons have lower rates of revision for infection in primary TKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 57 - 57
7 Aug 2023
Gill J Brimm D McMeniman P McMeniman T Myers P
Full Access

Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3). Results. The 14-year cumulative percentage revision (CPR) was 18.5% (95% CI 12.7, 26.4) for group 1, 19.7% (95% CI 18.8, 20.6) for group 2, and 19.2% (95% CI 18.5, 19.8) for group 3. There was no statistically significant difference in the (CPR) for the entire period when group 1 was compared to groups 2 or 3. Progression of arthritis was the indication for revision in similar proportions for the three groups (Group 1: 32.3%, Group 2: 35.7% and Group 3: 33.5%). Following per-operative arthroscopy 21.6% (77/356) of knees underwent a change of surgical plan from UKA to TKA. Conclusion. Per-operative arthroscopy may improve medium-term medial unicompartmental knee survivorship but does not improve long-term survivorship nor reduce revision due to progression of arthritis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 24 - 24
10 Feb 2023
Truong A Wall C Stoney J Graves S Lorimer M de Steiger R
Full Access

Obesity is a known risk factor for hip osteoarthritis. The aim of this study was to compare the incidence of obesity in Australians undergoing hip replacements (HR) for osteoarthritis to the general population. A cohort study was conducted comparing data from the Australian Bureau of Statistics and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 2017-18. Body mass index (BMI) data for patients undergoing primary total hip replacement and resurfacing for osteoarthritis were obtained from the AOANJRR. The distribution of HR patients by BMI category was compared to the general population, in age and sex sub-groups. During the study period, 32,495 primary HR were performed for osteoarthritis in Australia. Compared to the general population, there was a higher incidence of Class I, II, and III obesity in patients undergoing HR in both sexes aged 35 to 74 years old. Class III obese females and males undergoing HR were on average 6 to 7 years younger than their normal weight counterparts. Class III obese females and males aged 55-64 years old were 2.9 and 1.7 times more likely to undergo HR, respectively (p<0.001). There is a strong association between increased BMI and relative risk of undergoing HR. Similar findings have been noted in the United States of America, Canada, United Kingdom, Sweden and Spain. A New Zealand Registry study and recent meta-analysis have also found a concerning trend of Class III obese patients undergoing HR at a younger age. Obese Australians are at increased risk of undergoing HR at a younger age. A national approach to address the prevalence of obesity is needed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 107 - 107
10 Feb 2023
Xu J Sivakumar B Nandapalan H Moopanar T Harries D Page R Symes M
Full Access

Proximal humerus fractures (PHF) are common, accounting for approximately 5% of all fractures. Approximately 30% require surgical intervention which can range from open reduction with internal fixation (ORIF) to shoulder arthroplasty (including hemiarthroplasty, total shoulder arthroplasty, (TSA) or reverse total shoulder arthroplasty (RTSA)). The aim of this study was to assess trends in operative interventions for PHF in an Australian population. Data was retrospectively collected for patients diagnosed with a PHF and requiring surgical intervention between January 2001 and December 2020. Data for patients undergoing ORIF were extracted from the Medicare database, while data for patients receiving arthroplasty for PHF were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Across the study period, ORIF was the most common surgical procedure for management of PHFs. However, since 2019, RTSA has surpassed ORIF as the most common surgical procedure to treat PHFs, accounting for 51% of operations. While the number of RTSA procedures for PHF has increased, ORIF and shoulder hemiarthroplasty has significantly reduced since 2007 (p < 0.001). TSA has remained uncommon across the follow-up period, accounting for less than 1% of all operations. Patients younger than 65 years were more likely to receive ORIF, while those aged 65 years or greater were more likely to receive hemiarthroplasty or RTSA. While the number of ORIF procedures has increased during the period of interest, it has diminished as a proportion of overall procedure volume. RTSA is becoming increasingly popular, with decreasing utilization of hemiarthroplasty, and TSA for fracture remaining uncommon. These trends provide information that can be used to guide resource allocation and health provision in the future. A comparison to similar data from other nations would be useful


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 69 - 69
23 Feb 2023
Morgan S Wall C de Steiger R Graves S Page R Lorimer M
Full Access

The aim of this study was to examine the incidence of obesity in patients undergoing primary total shoulder replacement (TSR) (stemmed and reverse) for osteoarthritis (OA) in Australia compared to the incidence of obesity in the general population. A 2017–18 cohort of 2,621 patients from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) who underwent TSR, were compared with matched controls from the Australian Bureau of Statistics (ABS) National Health Survey from the same period. The two groups were analysed according to BMI category, sex and age. According to the 2017–18 National Health Survey, 35.6% of Australian adults are overweight and 31.3% are obese. Of the primary TSR cases performed, 34.2% were overweight and 28.6% were obese. The relative risk of requiring TSR for OA increased with increasing BMI category. Class-3 obese females, aged 55–64, were 8.9 times more likely to require TSR compared to normal weight counterparts. Males in the same age and BMI category were 2.5 times more likely. Class-3 obese patients underwent TSR 4 years (female) and 7 years (male) sooner than their normal weight counterparts. Our findings suggest that the obese population is at risk for early and more frequent TSR for OA. Previous studies demonstrate that obese patients undergoing TSR also exhibit increased risks of longer operative times, higher superficial infection rates, higher periprosthetic fracture rates, significantly reduced post-operative forward flexion range and greater revision rates. Obesity significantly increases the risk of requiring TSR. To our knowledge this is the first study to publish data pertaining to age and BMI stratification of TSR Societal efforts are vital to diminish the prevalence and burden of obesity related TSR. There may well be reversible pathophysiology in the obese population to address prior to surgery (adipokines, leptin, NMDA receptor upregulation). Surgery occurs due to recalcitrant or increased pain despite non-op Mx


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems. There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001). There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size. High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 64 - 64
10 Feb 2023
Lourens E Kurmis A Harries D de Steiger RN
Full Access

Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). While computer-navigation technologies in total knee arthroplasty show survivorship advantages and are widely used, comparable applications within THA show far lower utilisation. Using national registry data, this study compared patient reported outcome measures (PROMs) in patients who underwent THA with and without computer navigation. Data from Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) PROMs program included all primary THA procedures performed for OA up to 31 December 2020. Procedures using the Intellijoint HIP® navigation system were identified and compared to procedures using other computer navigation systems or conventional instrumentation only. Changes in PROM scores between pre-operative and 6-month post-operative time points were analysed using multiple regression model, adjusting for pre-operative score, patient age, gender, ASA score, BMI, surgical approach, and hospital type. There were 65 primary THA procedures that used the Intellijoint HIP® system, 90 procedures used other types of computer navigation, and the remaining 5,284 primary THA procedures used conventional instrumentation. The estimated mean changes in the EuroQol visual analogue scale (EQ VAS) score and Oxford Hip score did not differ significantly when Intellijoint® was compared to conventional instruments (estimated differences of 2.4, 95% CI [-1.7, 6.5], p = 0.245, and −0.5, 95% CI [-2.5, 1.4], p = 0.592, respectively). The proportion of patients who were satisfied with their procedure was also similar when Intellijoint® was compared to conventional instruments (rate ratio 1.06, 95% CI [0.97, 1.16], p = 0.227). The preliminary data demonstrate no significant difference in PROMs when comparing the Intellijoint HIP® THA navigation system with both other navigation systems and conventional instrumentation for primary THAs performed for OA. Level of evidence: III (National registry analysis)


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 83 - 83
1 Feb 2020
Shimmin A Pierrepont J Bare J McMahon S
Full Access

Introduction & aims. Apparently well-orientated total hip replacements (THR) can still fail due to functional component malalignment. Previously defined “safe zones” are not appropriate for all patients as they do not consider an individual's spinopelvic mobility. The Optimized Positioning System, OPS. TM. (Corin, UK), comprises preoperative planning based on a patient-specific dynamic analysis, and patient-specific instrumentation for delivery of the target component alignment. The aim of this study was to determine the early revision rate from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) for THRs implanted using OPS. TM. . Method. Between January 4. th. 2016 and December 20. st. 2017, a consecutive series of 841 OPS. TM. cementless total hip replacements were implanted using a Trinity acetabular cup (Corin, UK) with either a TriFit TS stem (98%) or a non-collared MetaFix stem (2%). 502 (59%) procedures were performed through a posterior approach, and 355 (41%) using the direct superior approach. Mean age was 64 (range; 27 to 92) and 51% were female. At a mean follow-up of 15 months (range; 3 to 27), the complete list of 857 patients was sent to the AOANJRR for analysis. Results. There were 5 revisions: . a periprosthetic femoral fracture at 1-month post-op in a 70F. a ceramic head fracture at 12-months post-op in a 59M. a femoral stem loosening at 7-months post-op in a 58M. a femoral stem loosening at 16-months post-op in a 64M. an anterior dislocation in a 53M, that was revised 9 days after the primary procedure. CT analysis, prior to revision surgery, revealed acetabular cup orientation of 46°/31° (inclination/anteversion) and femoral stem anteversion of 38°. Conclusions. These preliminary findings suggest the OPS. TM. dynamic planning and delivery system provides good early results, with a low rate of revision for dislocation. Limitations of the study will be discussed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 236 - 236
1 Sep 2012
Roche J Joss B DeSteiger R Miller L Nivbrant B Wood D
Full Access

There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a randomised controlled trial comparing fixed and mobile bearing of the same UKR prosthesis. Forty patients were randomized to receive identical femoral components and either a fixed or mobile bearing tibial component. At 6.5 years follow-up 37% of the mobile bearing design had been revised and 14% for the fixed bearing design. The main reasons for revision were pain and loosening. These results were compared with data from The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) that show a cumulative percent revision of 24.2% for the mobile bearing Preservation UKR at 6.5 years. All locally explanted mobile bearings were examined microscopically, and 83% demonstrated significant backside wear. Constraint on the undersurface of the bearing coupled with a congruent upper surface may have contributed to the excessive revision rate. This is the first randomised controlled trial examining mobile and fixed variations of the same UKR prosthesis and shows this design of UKR with the mobile bearing has an unacceptably high revision rate and patients with this knee design should be closely monitored


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 18 - 18
1 May 2018
Mammoliti L Van Bavel D De Steiger R Rainbird S
Full Access

Introduction/Aims. The Exeter Stem can be used with metal femoral head that are made of either cobalt chrome, or stainless steel. The aim of this study was to compare the rates of revision of these two metal femoral head types when used with this femoral component. Method. Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) Data from September 1999 until December 2015 for all primary THRs using an Exeter or an Exeter v40 stem with the diagnosis of osteoarthritis were analysed. Only bearing couples that used a metal head with polyethylene were included. The cumulative percent revision (CPR) calculated using Kaplan-Meier estimates were compared for the two metal head types. CPR were further analysed by age, polyethylene type and head size. Reasons for revision and types of revision were assessed. Results. There were 51666 THR that used Exeter or Exeter v40 stems of which 12554 had femoral heads made of cobalt chrome and 39112 had heads made of stainless steel. There was no difference in the rate of revision overall when head types were compared. There was also no difference in CPR between the two head types with age. Hips that used cobalt chrome heads had a higher CPR than stainless steel heads when these were used against non-crosslinked polyethylene. When heads with a diameter of 32mm or greater were compared, those made of cobalt chrome had a higher rate of revision than stainless steel HR 1.38 (1.15, 1.66) P<0.001). Conclusion. There was no difference comparing cobalt chrome or stainless-steel heads, except where non-crosslinked polyethylene was used, or where the heads size was 32mm or greater. In these comparisons, heads made from cobalt chrome had a higher rate of revision


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 3 - 3
1 Dec 2016
Dunbar M
Full Access

Over the past 15 years metal on metal hip resurfacing (MOMHR) has seen a spectacular resurgence in utilization followed by near abandonment of the procedure. A select group of surgeons still offer the procedure to a select group of patients suggesting that there are benefits of MOMHR over total hip arthroplasty (THA). This is problematic for the following reasons:. 1). MOMHR does not lead to increased survivorship. The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and the England and Wales National Joint Registry, from countries with high rates of utilization of MOMHR, both report significantly worse survivorship with MOMHR compared to all types of conventional THA. Risk factors for revision of resurfacing were older patients, females, smaller femoral head size, patients with developmental dysplasia, and certain implant designs. 2). MOMHR is associated with the generation of metal ions that can have devastating effects in some patients. Cobalt and chromium ions generated from MOMHR can result in adverse local tissues reactions around the hip, sometimes with catastrophic consequences, as well as neurological deficits, skin rashes, and cardiomyopathy. It is unclear as to which patients are at risk for the generation of high ion levels and less clear with respect to the host response to these ions. The discriminative and predictive values of ion testing are still being determined. MOMHR subsequently require careful follow-up with limited tools to assess risk and pending problems. 3). MOMHR is not less invasive. In order to deliver the femoral head for safe preparation and to access the acetabulum with the femoral head and neck in situ, significant dissection and retraction are required. The exposure issue is compounded as the procedure is most often performed in younger, larger males. Difficulty with exposure has been associated with an insult to the femoral head's blood supply that may lead to fracture and/or neck narrowing. 4). Preservation of the femoral canal with MOMHR does not improve outcomes of revision. The perceived advantage of preserved femoral head and neck implies that a conversion of a MOMHR to total hip should convey survivorship similar to primary THA. However, this is not the case as confirmed by data from the AOANJRR demonstrating worse survivorship of revised resurfacings when compared to a primary total hip arthroplasty. 5). MOMHR does not result in superior functional outcomes. Advocates for MOMHR often claim that the large femoral head and intact femoral neck in resurfacing results in a better functional outcome and therefore, a better quality of life and satisfaction when compared to a conventional THA. This, however, was not the case when gait speed, postural balance evaluations and functional tests were used in a randomised study of 48 patients, which failed to show an advantage of MOMHR over THA. In conclusion, it is relatively straightforward to oppose and argue against the use of hip resurfacings as they have worse outcomes in all National Joint Registries, produce metal ions with significant clinical consequences, are more invasive, are difficult to revise with subsequent inferior outcomes when compared to a conventional primary THA, and do not provide better function. These adverse features come with a premium price when compared to a conventional THA


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT