Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 3 - 3
1 Jul 2012
Bonner T Eardley W Newell N Masouros S Gibb I Matthews J Clasper J
Full Access

Circumferential pelvic binders have been developed to allow rapid closure of the pelvic ring in unstable fracture patterns. Despite evidence to support the use of pelvic binders, there is a paucity of clinical data regarding the effect of binder position on symphyseal diastasis reduction. All patients presenting to the UK's military hospital in Afghanistan who survived and underwent pelvic radiography were reviewed. Cases were identified by retrospective assessment of all digital plain pelvic radiographs performed between January 2008 and July 2010. All radiographs and CT images were assessed to identify the presence of any pelvic fracture. Patients were grouped into three categories according to the vertical level of the buckle: superior to the trochanters (high), inferior to the trochanters (low) and at the level of the trochanters (troch). Diastasis reduction was measured in patients with Anterior-Posterior Compression (APC) grades II and III, or Combined Mechanical Injuries(CMI). Comparison of diastasis reduction between the high and troch groups was assessed by an independent samples Student's t-test. We identified 172 radiographs where the metallic springs in the buckle of a SAM Pelvic Sling. ™. were clearly visible. The binders were positioned at the trochanteric level in 50% of radiographs. A high position was the commonest site of inaccurate placement (37%). In the patients with fractures and an open diastasis, the mean pelvic diastasis gap was 2.75 times greater in the high group compared to the trochanteric level (mean difference 22 mm) (p < 0.01). Application of pelvic binders superior to the greater trochanters is commonplace and associated with inadequate fracture reduction, which is likely to delay cardiovascular recovery in these significantly injured casualties


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 52 - 52
1 Oct 2022
Müller N Trampuz A Gonzalez-Moreno M
Full Access

Aim. The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth. Method. Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis (MRSE). Vancomycin was tested at the minimum-inhibitory-concentration for each strain (1 µg/ml for MRSA; 2 μg/ml for MRSE). To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry. Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h. Results. All BAG formulations showed antibiofilm activity against MRSA and MRSE in a time-dependent manner, where longer incubation times revealed higher antibiofilm activity. BAG-powder and BAG-putty-B were the most effective formulations suppressing biofilm, followed by BAG-granules, BAG-scaffold and finally BAG-putty-A. The addition of vancomycin had no substantial impact on biofilm suppression. An increase in pH and osmotic pressure over time could be observed for all BAG formulations. BAG-powder reached the highest pH value of 12.5, whereas BAG-putty-A resulted in the lowest pH of 9. Both BAG-putty formulations displayed the greatest increase on osmotic pressure. Conclusions. BAG-S53P4 has demonstrated efficient biofilm suppression against MRSA and MRSE, especially in powder-containing formulations. Our data indicates no additional antibiofilm improvement with addition of vancomycin. Moreover, high pH appears to have a larger antimicrobial impact than high osmolarity. Acknowledgements. This work was supported by PRO-IMPLANT Foundation (Berlin, Germany). The tested materials were provided by Bonalive Biomaterials Ltd (Turku, Finland)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 4 - 4
1 May 2012
A.M. C C. D W. DM J.J. M
Full Access

Introduction. A common injury pattern in current military experience is traumatic lower limb amputation from improvised explosive devices. This injury can co-exist with pelvic girdle fractures. Methods. We reviewed 67 consecutive patients with traumatic lower limb amputations treated in Camp Bastion Hospital, Afghanistan. Results. 16 (24%) had an associated pelvic fracture (10 APC/vertical shear and 6 acetabular or pubic rami fractures). Traumatic single amputees (n=28) had a 14% incidence of associated pelvic fracture with traumatic double amputees (n=39) increasing this association to 31%. However, if the double amputations were above knee, the incidence of associated open book fractures was 26% (6/23) with 39% (9/23) sustaining some form of bony pelvic injury. The majority of patients (95%) had a pelvic X-ray as part of the primary survey. Of these 51% (n=34) had a Sam sling. (r). in situ but only fifteen were deemed appropriately applied. Conclusions. Given the high risk of pelvic fractures in patients with traumatic bilateral lower limb amputations, particularly those involving opening of the pelvic ring, it is imperative that the earliest and proper application of a pelvic binder be initiated