Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 56 - 56
1 Dec 2020
TOKTAŞ AG AKYÜREKLİ S OKUMUŞ Y GÜL M KÖSE N DOĞAN A
Full Access

Musculoskeletal disorders is one of most important health problems human population is facing includes. Approximately 310 thousand of hip protheses have been used in 45 years and older patients in total according to the recent studies have been done. [1, 2]. Many factors, including poor osseointegration or relaxation of the implant due to stress, limit the life of the load-bearing implants [3]. To overcome these difficulties and to protect metal implants inside the body, the surfaces of the implants were coated with silver ion doped hydroxyapatite/bioglass. In this study, silver doped hydroxyapatite ceramic powder and 6P57 bioglass were synthesized. Two different coating suspensions, 100% bioglass and 70% Ag-HAp / 30% bioglass, were prepared in methyl alcohol with a solid content of 1% by weight. Two layers were coated on the external fixator nails by using electrospray method with the bioglass and Ag-Hap/Bioglass suspensions respectively. The coated implants were cut with an equal surface area and kept in human blood plasma for different time. The scanning electron microscopy (SEM, Zeiss Supra 50VP and Zeiss Evo 50EP) and stereo microscope (Zeiss Axiocam Stemi 2000-C) were used to characterize microstructure and thickness of coated surface. Energy dispersive X-ray Spectroscopy was used characterized of chemical composition of coating. Changing of pH value of plasma was measured by pH meter (Hanna HI83414). In addition, the ICP method was used to determine the elements contained in the plasma fluid after dissolution. As a result of this study, physical and chemical changes occurring on the coating surface in different time periods are presented in detail


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 118 - 118
1 Dec 2020
Vallejos R Contreras J Aiyangar A Palza H Vivanco JF
Full Access

Bioactive glasses, such as 45S5 Bioglass (BG), have been shown to promote bone ingrowth both in vitro and in vivo. The goal of this study was to analyze the effect of a high dose of BG (20%) in Direct Ink Writing (DIW)-produced controlled-geometry PCL-BG composite scaffolds in both their mechanical and biological performance. Porous cubes of 5 × 5 × 5 mm, 50% porosity and pore size and strut diameter of 400 µm were fabricated in a 3D-Bioplotter (EnvisionTec) to investigate their biological performance (n = 3). Additionally, cylindrical specimens (10 mm diameter; 15 mm height) with same internal structure were fabricated for mechanical testing (n = 6). The cylindrical specimens were tested by compression in a universal testing machine (ZwickRoell) with a 10 kN load cell. The tests were performed at 1.00 mm/min with extensometers in both sides. For biological characterization, scaffolds were sterilized in 70% ethanol overnight and pre-incubated with DMEM for 1 hour at room temperature. 1×10. 5. human gingival mesenchymal stem cells (hGMSCs) in 50 µl DMEM were seeded on the scaffolds using agarose molds to improve cell adhesion, and cultured in standard cell-culture conditions for 3, 7 and 14 days. To measure cell proliferation, the reagent CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS, Promega) was added to the cell-seeded scaffolds at each time point, using non-seeded scaffolds as blank controls. The OD (490 nm) was measured in a BioTek 800 TS plate reader. Both the apparent elastic modulus and yield stress were significantly lower in the scaffolds with 20% BG than their PCL control counterparts (p < 0.0001 for elastic modulus and p < 0.005 for yield stress, t-test). Cell proliferation in the scaffolds by MTS was variable, with the 20% BG scaffolds showing a significantly higher signal after seven days in culture (p < 0.05 by t-test), but a significantly lower signal after 14 days in culture (p < 0.05 by t-test). In conclusion, scaffolds with 20% BG showed a lower mechanical performance than their PCL counterparts in terms of both their apparent elastic modulus and yield stress. Additionally, scaffolds with 20% BG showed variable cell proliferation rates in terms of their metabolic activity over a two-week period. The decrease in proliferation rate after week 2 after an initial increase at the end of week 1 could be due to cytotoxic effects of the BG at this high dose (20%) after long term exposure. These results suggest that a dosage of 20% BG may not necessarily improve the mechanical and biological performance of scaffolds, so future experiments are required in order to characterize the optimum BG dosage in PCL scaffolds for tissue engineering applications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 15 - 15
1 Aug 2012
Allen F Blunn G McCarthy I O'Donnell M Stevens M Goodship A
Full Access

Synthetic bone grafts are used in several major dental and orthopaedic procedures. Strontium, in the form of strontium ranelate, has been shown to reduce fracture risk when used to treat osteoporosis. The aim of the study was to compare bone repair in femoral condyle defects filled with either a 10% strontium substituted bioactive glass (StronBoneTM) or a TCP-CaSO4 graft. We hypothesise that strontium substituted bioactive glass increases the rate of bone ingrowth into a bone defect when compared to a TCP-CaSO4 ceramic graft. A critical size defect was created in the medial femoral condyle of 24 sheep; half were treated with a Sr-bioactive glass (StronBoneTM), and in the other animals defects were filled TCP-CaSO4. Two time points of 90 and 180 days were selected. The samples were examined with regard to: bone mineral density (BMD) from peripheral quantitative CT (pQCT), mechanical properties through indentation testing, and bony ingrowth and graft resorption through histomorphometry. The radiological density of Sr-bioactive glass in the defect is significantly higher than that of the TCP-CaSO4-filled defect at 90 and 180 days, (p=0.035 and p=0.000). At 90 days, the stiffness of the defect containing Sr-bioactive glass and is higher than that of the TCP-CaSO4 filled defect, (p=0.023). At 6 months there is no significant difference between the two materials. Histomorphometry showed no significant difference in bone ingrowth at any time point, however significantly more of the graft is retained for the StronBoneTM treatment group than the TCP-CaSO4 group at both 0 days (p=0.004) and 180 days (p=0.000). The amount of soft tissue within the defect was significantly less in the StronBoneTM group than for the TCP-CaSO4 group at 90 days (p=0.006) and 180 days (p=0.000). The data shows the mechanical stability of the defect site is regained at a faster rate with the strontium substituted bioglass than the TCP-CaSO4 alternative. Histomorphmetry shows this is not due to increased bone ingrowth but may be due to the incorporation of stiff graft particles into the trabeculae. Sr-bioactive glass produces a stronger repair of a femoral condyle defect at 3 months compared with TCP-CaSO4


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed.

In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups.

After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate.

Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes.

Cite this article: Bone Joint J 2014; 96-B:845–50.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 1 - 1
1 Dec 2020
Gögele CL Kerling V Lenhart A Wiltzsch S Schäfer-Eckart K Minnich B Weiger TM Schulze-Tanzil G
Full Access

Cartilage injuries often represent irreversible tissue damage because cartilage has only a low ability to regenerate. Thus, cartilage loss results in permanent damage, which can become the starting point for osteoarthritis. In the past, bioactive glass scaffolds have been developed for bone replacement and some of these variants have also been colonized with chondrocytes. However, the hydroxylapaptite phase that is usually formed in bioglass scaffolds is not very suitable for cartilage formation (chondrogenesis). This interdisciplinary project was undertaken to develop a novel slowly degrading bioactive glass scaffold tailored for cartilage repair by resembling the native extracellular cartilage matrix (ECM) in structure and surface properties. When colonized with articular chondrocytes, the composition and topology of the scaffolds should support cell adherence, proliferation and ECM synthesis as a prerequisite for chondrogenesis in the scaffold. To study cell growth in the scaffold, the scaffolds were colonized with human mesenchymal stromal cells (hMSCs) and primary porcine articular chondrocytes (pACs) (27,777.8 cells per mm. 3. ) for 7 – 35 d in a rotatory device. Cell survival in the scaffold was determined by vitality assay. Scanning electron microscopy (SEM) visualized cell ultramorphology and direct interaction of hMSCs and pACs with the bioglass surface. Cell proliferation was detected by CyQuant assay. Subsequently, the production of sulphated glycosaminoglycans (sGAGs) typical for chondrogenic differentiation was depicted by Alcian blue staining and quantified by dimethylmethylene blue assay assay. Quantitative real-time polymerase chain reaction (QPCR) revealed gene expression of cartilage-specific aggrecan, Sox9, collagen type II and dedifferentiation-associated collagen type I. To demonstrate the ECM-protein synthesis of the cells, the production of collagen type II and type I was determined by immunolabelling. The bioactive glass scaffold remained stable over the whole observation time and allowed the survival of hMSCs and pACs for 35 days in culture. The SEM analyses revealed an intimate cell-biomaterial interaction for both cell types showing cell spreading, formation of numerous filopodia and ECM deposition. Both cell types revealed initial proliferation, decreasing after 14 days and becoming elevated again after 21 days. hMSCs formed cell clusters, whereas pACs showed an even distribution. Both cell types filled more and more the pores of the scaffold. The relative gene expression of cartilage-specific markers could be proven for hMSCs and pACs. Cell associated sGAGs deposition could be demonstrated by Alcian blue staining and sGAGs were elevated in the beginning and end of the culturing period. While the production of collagen type II could be observed with both cell types, the synthesis of aggrecan could not be detected in scaffolds seeded with hMSCs. hMSCs and pACs adhered, spread and survived on the novel bioactive glass scaffolds and exhibited a chondrocytic phenotype


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 114 - 114
1 Nov 2021
Başal Ö Ozmen O Deliormanli AM
Full Access

Introduction and Objective. Bone is a tissue which continually regenerates and also having the ability to heal after injuries however, healing of large defects requires intensive surgical treatment. Bioactive glasses are unique materials that can be utilized in both bone and skin regeneration and repair. They are degradable in physiological fluids and have osteoconductive, osteoinductive and osteostimulative properties. Osteoinductive growth factors such as Bone Morphogenetic Proteins (BMP), Vascular Endothelial Growth Factor (VEGF), Epidermal Growth Factor (EGF), Transforming Growth Factor (TGF) are well known to stimulate new bone formation and regeneration. Unfortunately, the synthesis of these factors is not cost- effective and, the broad application of growth factors is limited by their poor stability in the scaffolds. Instead, it is wise to incorporate osteoinductive nanomaterials such as graphene nanoplatelets into the structures of synthetic scaffolds. In this study, borate-based 13-93B3 bioactive glass scaffolds were prepared by polymer foam replication method and they were coated with graphene-containing poly (ε-caprolactone) layer to support the bone repair and regeneration. Materials and Methods. Effects of graphene concentration (1, 3, 5, 10 wt%) on the healing of rat segmental femur defects were investigated in vivo using male Sprague–Dawley rats. Fabricated porous bioactive glass scaffolds were coated by graphene- containing polycaprolactone solution using dip coating method. The prepared 0, 1, 3, 5 and 10 wt% graphene nanoparticle-containing PCL-coated composite scaffolds were designated as BG, 1G-P-BG, 3G-P-BG, 5G-P-BG and 10G-P-BG, for each group (n: 4) respectively. Histopathological and immunohistochemical (bone morphogenetic protein, BMP-2; smooth muscle actin, SMA and alkaline phosphatase, ALP) examinations were made after 4 and 8 weeks of implantation. Results. Results showed that after 8-weeks of implantation both cartilage and bone formation were observed in all animal groups. After 4 and 8 weeks of implantation the both osteoblast and osteoclast numbers were significantly higher in the group 4 compared to the control group. Bone formation was significant starting from 1 wt% graphene-coated bioactive glass implanted group and highest amount of bone formation was obtained in group containing 10 wt% graphene (p<0.001). Newly formed vessels expressed this marker and increased vascularization was observed in 8- weeks period compared to the 4-weeks period. In addition, an increase in new vessel formation were observed in graphene-coated scaffold implanted groups compared to the control group. While cartilage tissue was observed in control group, bone formation percentages were significant in graphene-coated scaffold implanted groups. Highest amount of bone formation occurred in group 4 (10 % wt G-C). Conclusions. Additionally, the presence of graphene nanoplatelets enhanced the BMP-2, SMA and ALP levels compared to the bare bioactive glass scaffolds. It was concluded that pristine graphene-coated bioactive glass scaffolds improve osteointegration and bone formation in rat femur defect when compared to bare bioglass scaffolds


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 118 - 124
1 Jan 1999
Brewster NT Gillespie WJ Howie CR Madabhushi SPG Usmani AS Fairbairn DR

In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using morsellised allograft bone from the femoral head which have shown that its mechanical properties improve with increasing normal load and with increasing shear strains (strain hardening). The mechanical strength also increases with increasing compaction energy, and with the addition of bioglass particles to make good the deficiency in small and very small fragments. Donor femoral heads may be milled while frozen without affecting the profile of the particle size. Osteoporotic femoral heads provide a similar grading of sizes, although fewer particles are obtained from each specimen. Our findings have implications for current practice and for the future development of materials and techniques