Scaphoid fractures accounts for approximately 15% of all fractures of hand and wrist. Proximal pole fractures represent 10–20% of scaphoid fractures. Non –operative treatment shows high incidence of non-union and avascular necrosis. Surgical intervention with bone graft is associated with better outcome. The aim of this study was to evaluate the radiological and functional outcome of management of proximal pole scaphoid non-union with internal fixation and bone grafting. We included 35 patients with proximal pole scaphoid non-union (2008–2015). All patients underwent antegrade headless
Prospective Randomised Control trial of 300 patients over a period of 3 years, 1 year post op follow up. Local ethic approval was attained for the study. Inclusion criteria: Age > 60, Consented to Participate in the study, Unstable Inter trochanteric fracture a) Sub trochanteric b) Medial Comminution c) Reverse Obliquity D)Severe Osteoporosis. Patients selected were randomized to Intra medullary Nail vs Hips screw. Variety of markers have been assessed: Pre OP: - Mechanism of injury, Mobility status, Pre OP ASA, Pre Op haemoglobin, living Conditions. Intra OP:- I.I Time, Time taken, Surgeon experience, Intra OP complications. Post OP:- Haemoglobin, mobility, radiographic analysis-Fracture stability and Tip Apex Distance, Thrombo embolic Complications. Follow up: - 6 weeks, 3,6,12 month follow up. There is considerable debate in literature regarding superiority of
In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23)) We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.
–A: postoperative length –A’: POD 1year –B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter) –B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter) –
Limb length(shortening) was adjusted considering difference of magnification = {A × (B’/B)}− A’Introduction
Materials and Methods
INTRODUCTION. Reverse shoulder arthroplasty (RSA) provides an effective alternative to anatomic shoulder replacements for individuals with cuff tear arthropathy, but certain osteoarthritic glenoid deformities make it challenging to achieve sufficient long term fixation. To compensate for bone loss, increase available bone stock, and lateralize the glenohumeral joint center of rotation, bony increased offset RSA (BIO-RSA) uses a cancellous autograft for baseplate augmentation that is harvested prior to humeral head resection. The motivations for this computational study are twofold: finite element (FE) studies of BIO-RSA are absent from the literature, and guidance in the literature on screw orientations that achieve optimal fixation varies. This study computationally evaluates how screw configuration affects BIO-RSA graft micromotion relative to the implant baseplate and glenoid. METHODS. A senior shoulder specialist (GSA) selected a scapula with a Walch Type B2 deformity from patient CT scans. DICOM images were converted to a 3D model, which underwent simulated BIO-RSA with three screw configurations: 2 divergent superior & inferior locking screws with 2 convergent anterior & posterior
Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at
Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the headless
Introduction. Aseptic glenoid loosening is a common failure mode of reverse shoulder arthroplasty (rTSA). Achieving initial glenoid fixation can be a challenge for the orthopedic surgeon since rTSA is commonly used in elderly osteoporotic patients and is increasingly used in scapula with significant boney defects. Multiple rTSA baseplate designs are available in the marketplace, these prostheses offer between 2 and 6 screw options, with each screw hole accepting a locking and/or
Longstanding un-united scaphoid fractures or scapholunate insufficiency can progress to degenerative wrist osteoarthritis (termed scaphoid non-union advanced collapse (SNAC) or scapho-lunate advanced collapse (SLAC) respectively). Scaphoid excision and partial wrist fusion is a well-established procedure for the surgical treatment of this condition. In this study we present a novel technique and mid-term results, where fusion is reserved for the luno-capitate and triquetro-hamate joints, commonly referred to as bicolumnar fusion. The purpose of this study was to report functional and radiological outcomes in a series of patients who underwent this surgical technique. This was a prospective study of 23 consecutive patients (25 wrists) who underwent a bicolumnar carpal fusion from January 2014 to January 2017 due to a stage 2 or 3 SNAC/SLAC wrist, with a minimum follow-up of one year. In all cases two retrograde cannulated headless
Introduction. Achieving prosthesis fixation in patients with glenoid defects can be challenging, particularly when the bony defects are large. To that end, this study quantifies the impact of 2 different sizes of large anterior glenoid defects on reverse shoulder glenoid fixation in a composite scapula model using the recently approved ASTM F 2028–14 reverse shoulder glenoid loosening test method. Methods. This rTSA glenoid loosening test was conducted according to ASTM F 2028–14; we quantified glenoid fixation of a 38mm reverse shoulder (Equinoxe, Exactech, Inc) in composite/dual density scapulae (Pacific Research, Inc) before and after cyclic testing of 750N for 10k cycles. Anterior defects of 8.5mm (31% of glenoid width and 21% of glenoid height; n=7) and 12.5mm (46% of glenoid width and 30% of glenoid height; n=7) were milled into the composite scapula along the S/I glenoid axis with the aid of a custom jig. The baseplate fixation in scapula with anterior glenoid defects was compared to that of scapula without an anterior glenoid defect (n = 7). For the non-defect scapula, initial fixation of the glenoid baseplates were achieved using 4, 4.5×30mm diameter poly-axial locking
Aim. Distal interphalangeal joint (DIPJ) arthrodesis is a well-accepted treatment of disease in the DIPJ of the hand. The ideal technique should be technically simple, quick, cheap, have minimal complications and yield a rapid return to function. Recent large published series report major complications of 11.1% and minor complications of 26% for this procedure. The study objective is to determine patient satisfaction and complication rates of DIPJ fusion using the Autofix screw (Small Bone Innovations, France), a smaller diameter headless
Introduction. Degenerative, inflammatory, and posttraumatic arthritis of the ankle are the primary indications for total ankle arthroplasty. Ankle arthrodesis has long been the “gold standard” for the surgical treatment. Total Ankle Arthroplasty. implant survivorship has been reported to range from 70% to 98% at three to six years. The combination of younger age and hindfoot arthrodesis or osteoarthritis may lead to a relative increase in failure rates after TAA. Intraoperative complication include malaligment, fracture and tendon Postoperative complications include syndesmotic nonunion, wound problems, infections and component instability and lysis. After TAA few difficulties mainly due to poor Talar and Tibial bone stock. It is difficult to stabilize the fusion and usually there is shortening after removal of the implant. Also there is a need for massive bone graft-allograft or autograft. In cases when there is significant bone loss there is a need for stable reconstruction and stabilization of the hindfoot. Bone grafting with structural bone graft may collapse and it has to be stabilized with screws or nail. Methods. We developed technique which included distraction of the fusion area and inserting a Titanium cylindrical spinal cage filled with bone graft. Than guide wire was inserted in through the cage under fluoroscopy and a
Trans-articular coronal shear fractures of the distal humerus pose a significant challenge to the surgeon in obtaining an anatomical reduction and rigid fixation and thereby return of good function. A variety of approaches have been described which include the extended lateral and anterolateral approaches and arthroscopically-assisted fixation for non-comminuted fractures. Fixation methods include open or percutaneous cannulated screws and headless
Shape memory staples have several uses in both hand and foot and ankle surgery. There is relatively little data available regarding the biomechanical properties of staples, in terms of both the compression achieved and potential decay of mechanical advantage with time. An understanding of these properties is therefore important for the surgeon. Two blocks of synthetic polyurethane mimicking properties of cancellous bone were fixed in jigs to both the actuator and 6 degree-of-freedom load cell of an MTS servohydraulic testing machine. With the displacement between the blocks held constant the peak value and subsequent decay in compressive force applied by both the smooth and barbed version of the nitinol OSStaple (Biomedical Enterprises), Easyclip (LMT), Herbert Bone Screws (Martin) and the Headless
Introduction. Little guidance exists regarding the minimum screw length and number necessary to achieve fixation with reverse shoulder arthroplasty (rTSA). The goal of this study is to quantify the pre- and post-cyclic baseplate displacements associated with two baseplate designs of different sizes using multiple screw lengths and numbers in a low density polyurethane bone substitute model. Methods. The test was conducted according to ASTM F 2028–17. The baseplate displacements of standard and small reverse shoulder constructs (Equinoxe, Exactech, Inc.) were quantified in a 15pcf polyurethane block (Pacific Research, Inc.) before and after cyclic testing with an applied load of 750N for 10,000 cycles. Baseplates were constructed using 2 or 4 screws with 3 different poly-axial locking
Introduction. Arthrodesis of the 1st metatarso-phalangeal joint (MTPJ) is a common procedure in forefoot surgery for hallux rigidus and severe hallux valgus. Debate persists on two issues - the best preparation method for the articular surfaces, and the optimal technique for operative stabilisation of the joint. Methods. We performed 1. st. MTPJ arthrodesis in 100 patients randomized into two equal groups. In the first group, the articular surfaces were prepared using cup-and-cone reamers, whilst in the second group, ‘flat cut’ osteotomies were performed with an oscillating saw. In all other respects, their treatment was identical. Fixation was secured using a plantar double
Lateralization of the reverse arthroplasty may be desirable to more effectively tension the remaining rotator cuff, decrease scapular notching, improve the cosmetic appearance of the shoulder, and improve stability as well as the arc of motion prior to impingement. There are two primary options to lateralise a reverse shoulder arthroplasty: bone graft with a long post (BIO-RSA) vs. using metal. The two metal options generally include a thicker glenosphere or a thicker glenoid baseplate. Potential benefits of a BIO-RSA include lateralization of the glenoid center of rotation but without placing the center of rotation lateral to the prosthetic-bone interface. By maintaining the position of the center of rotation, the shear forces at the prosthesis-bone interface are lessened and are converted to compressive forces which will minimise glenoid failure. Edwards et al. performed a prospective study on a bony increased offset reverse arthroplasty. Among the 18 shoulders in the BIO-RSA group, the incidence of notching was 78% compared to controls 70%. The graft completely incorporated in 12 (67%), partially incorporated in 4 (22%), and failed to incorporate in 2 (11%). Frankle et al. reported on the minimum 5-year follow-up of reverse arthroplasty with a central
Introduction and Aims:. The surgical treatment of fractures of the scaphoid with delayed presentation or with established non-union pose a formidable challenge with reported failure rates between 15% and 45%. The aim of this study is to report the results of percutaneous versus open fixation with bone grafting of these fractures. Method:. 34 Consecutive patients who underwent surgery between 2009 and 2013 for delayed presentation and established non-union of scaphoid fractures have been reviewed retrospectively. There were 27 males and 7 females with a mean age of 31 years (15 to 66). The mean delay from time of injury to operation was 12 weeks (4 weeks to 11 months) in the percutaneous fixation group and 19 months (5 months to 6 years) in the open fixation group. 19 Patients were treated with percutaneous screw fixation alone and 15 patients underwent open reduction and internal fixation supplemented with autogenous corticocancellous iliac bone graft. The classification of Slade and Dodds (2009) was used as a guide for surgical treatment and the Mini-Acutrak headless
Thoracic Outlet Syndrome (TOS) is a complex of symptoms representing neurovascular compression in the supraclavicular area and shoulder girdle. Arterial thoracic outlet syndrome represents only 1% of all TOS's. We present two cases of arterial TOS's following internal fixation of clavicular fractures. Two cases of clavicular fractures managed with internal fixation and subsequently diagnosed with symptomatic, position dependent arterial occlusion are presented. The first case of a 16-year-old male treated with an intramedullary
Purpose. Although multiple surgical options exist for chronic static scapholunate dissociation, no single procedure has been found to be superior clinically or kinematically. We hypothesize that the reduction and association of the scaphoid and lunate (RASL procedure) is a safe and effective procedure that improves function and alleviates pain in the injured wrist. The purpose of this study is to report long-term follow-up of patients undergoing the RASL procedure over a 20-year period. Method. Between December 1991 and September 2008, the senior author performed 36 RASL procedures for chronic static scapholunate dissociation. This reconstruction involves reduction of the rotational deformity and diastasis between the scaphoid and lunate through a dorsal approach to the wrist. Maintenance of reduction is accomplished with a cannulated, headless, smooth-shafted
The quality of bone in the skeleton depends on the amount of bone, geometry, microarchitecture and material properties, and the molecular and cellular regulation of bone turnover and repair. This study aimed to identify material and structural factors that alter in fragility hip fracture patients treated with antiresorption therapies (FxAr) compared to fragility hip fracture patients not on treatment (Fx). Bone from the intertrochanteric site, femoral head (FH: FxAr = 5, Fx = 8),