Progressive degenerative changes in the medial
compartment of the knee following lateral unicompartmental arthroplasty
(UKA) remains a leading indication for revision surgery. The purpose
of this study is to evaluate changes in the
Introduction:. The number of medial unicompartmental knee arthroplasties (UKA) performed over the last decade has increased by 30%, as studies have demonstrated improved knee kinematics, range of motion, and decreased perioperative morbidity versus total knee arthroplasty. However, concerns remain regarding the future risk of revision due to lateral compartment degeneration. In patients with a varus mechanical alignment and tibiofemoral subluxation secondary to medial compartment osteoarthritis, the femoral and tibial articular surfaces of the lateral compartment subsequently become incongruous, potentially increasing the focal contact stresses seen with loading. The purpose of this study is to evaluate whether the tibiofemoral
Aims. The aim of this study was to evaluate cartilaginous patellotrochlear
Introduction. Chronic uneven distribution of forces over the articular cartilage, which are present in OA, has been shown to be a risk factor for the development of OA. Certain regions of the articular cartilage will be exposed to increased chronic peak loads, whereas other regions encounter a corresponding relative reduction of transmitted forces. This has a well known influence on cartilage viability and is a precursor of degenerative progression.
Objectives. The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo. Methods. Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius. Results. The experimental SR is comparable with the calculated SR (mean difference 10%, . sd. 8%; relative values). The experimental incongruence study observed almost no differences (2%, . sd. 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, . sd. 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, . sd. 55%). Conclusion. The present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended. Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of
Conventional pre-operative planning for total hip arthroplasty mostly relies on the patient radiologic anatomy for the positioning and choice of implants. This kind of planning essentially remains a static approach since dynamic aspects such as the joint kinematics are not taken into account. Hence, clinicians are not able to fully consider the evolving behavior of the prosthetic joint that may lead to implant failures. In fact, kinematics plays an important role since some movement may create conflicts within the prosthetic joint and even provoke dislocations. The goal of our study was to assess the relationship between acetabular implant positioning variations and resultant impingements and loss of joint congruence during daily activities. In order to obtain accurate hip joint kinematics for simulation, we performed an in-vivo study using optical motion capture and magnetic resonance imaging (MRI). Motion capture and MRI was carried out on 4 healthy volunteers (mean age, 28 years). Motion from the subjects was acquired during routine (stand-to-sit, lie down) and specific activities (lace the shoes while seated, pick an object on the floor while seated or standing) known to be prone to implant dislocation and impingement. The hip joint kinematics was computed from the recorded markers trajectories using a validated optimized fitting algorithm (accuracy: translational error ≍ 0.5 mm, rotational error < 3°) which accounted for skin motion artifactsand patient-specific anatomical constraints (e.g. bone geometry reconstructed from MRI, hip joint center) (Fig. 1). 3D models of prosthetic hip joints (pelvis, proximal femur, cup, stem, head) were developed based on variations of acetabular cup's inclination (40°, 45°, 60°) and anteversion (0°, 15°, 30°) parameters, resulting in a total of 9 different implant configurations. Femoral anteversion remained fixed and determined as “neutral” with the stem being parallel to the posterior cortex of the femoral neck. Motion capture data of daily tasks were applied to all implant configurations. While visualizing the prosthetic models in motion, a collision detection algorithm was used to locate abnormal contacts between both bony and prosthetic components (Fig. 2). Moreover, femoral head translations (subluxation) were computed to evaluate the joint congruence.Introduction
Methods
The aim of this study was to determine and compare the congruency of the articular surface contact area of the patellofemoral joint (PFJ) during both active and passive movement of the knee with the use of an MRI mapping technique in both the stable and unstable PFJ. A prospective case-control MRI imaging study of patients with a history of PFJ instability and a control group of volunteers without knee symptoms was performed. The PFJs were imaged with the use of an MRI scan during both passive and active movement from 0° through to 40° of flexion. The congruency through measurement of the contact surface area was mapped in 5-mm intervals on axial slices. In all, 40 patients were studied. The case group included 31 patients with symptomatic patellofemoral instability and the control group of nine asymptomatic volunteers. The ages were well matched between the case and control groups. The mean age was 25 years (16 to 42; Aims
Patients and Methods
Aims. Treatment of Weber B ankle fractures that are stable on weightbearing radiographs but unstable on concomitant stress tests (classified SER4a) is controversial. Recent studies indicate that these fractures should be treated nonoperatively, but no studies have compared alternative nonoperative options. This study aims to evaluate patient-reported outcomes and the safety of fracture treatment using functional orthosis versus cast immobilization. Methods. A total of 110 patients with Weber B/SER4a ankle fractures will be randomized (1:1 ratio) to receive six weeks of functional orthosis treatment or cast immobilization with a two-year follow-up. The primary outcome is patient-reported ankle function and symptoms measured by the Manchester-Oxford Foot and Ankle Questionnaire (MOxFQ); secondary outcomes include Olerud-Molander Ankle Score, radiological evaluation of ankle
Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line
Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. Methods. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels. Results. A total of 140 knees (130 patients) were identified for analysis. At mean 4.1 years (2.0 to 8.5) follow-up, good to excellent Kujala scores were reported. The presence of mild to moderate preoperative patellofemoral joint osteoarthritis had no impact on these scores (KL grade 0 vs 1 to 3, p = 0.203; grade 0 to 1 vs 2 to 3, p = 0.674). Comparable scores were reported by patients with osteoarthritis (Altman score of ≥ 2) evident on either the medial or lateral patellofemoral joint facet (medial, p = 0.600 and lateral, p = 0.950). Patients with abnormal patellar
Despite the current trend favoring surgical treatment of displaced intra-articular calcaneal fractures (DIACFs), studies have not been able to demonstrate superior functional outcomes when compared to non-operative treatment. These fractures are notoriously difficult to reduce. Studies investigating surgical fixation often lack information about the quality of reduction even though it may play an important role in the success of this procedure. We wanted to establish if, amongst surgically treated DIACF, an anatomic reduction led to improved functional outcomes at 12 months. From July 2011 to December 2020, at a level I trauma center, 84 patients with an isolated DIACF scheduled for surgical fixation with plate and screws using a lateral extensile approach were enrolled in this prospective cohort study and followed over a 12-month period. Post-operative computed tomography (CT) imaging of bilateral feet was obtained to assess surgical reduction using a combination of pre-determined parameters: Böhler's angle, calcaneal height,
Despite the current trend favoring surgical treatment of displaced intra-articular calcaneal fractures (DIACFs), studies have not been able to demonstrate superior functional outcomes when compared to non-operative treatment. These fractures are notoriously difficult to reduce. Studies investigating surgical fixation often lack information about the quality of reduction even though it may play an important role in the success of this procedure. We wanted to establish if, amongst surgically treated DIACF, an anatomic reduction led to improved functional outcomes at 12 months. From July 2011 to December 2020, at a level I trauma center, 84 patients with an isolated DIACF scheduled for surgical fixation with plate and screws using a lateral extensile approach were enrolled in this prospective cohort study and followed over a 12-month period. Post-operative computed tomography (CT) imaging of bilateral feet was obtained to assess surgical reduction using a combination of pre-determined parameters: Böhler's angle, calcaneal height,
Menisci are crucial structures for knee homeostasis: they provide increase of
Seventy-four mobile bearing total knee arthroplasties (LCS) without patellar resurfacing were analysed in 54 patients who were followed for a minimum of one year. We examined the
Introduction. Up to 15 % of patients report anterior knee pain (AKP) after a total knee arthroplasty (TKA). The correlation of radiographic patellar measurements and post-operative AKP remains controversial. The purpose of this study was to determine whether any radiographic measurements can predict anterior knee pain after TKA. Methods. We performed a retrospective analysis of data on 343 patients who underwent a primary unilateral TKA between 2009–2012 at a single institution. Post-operative radiographs were evaluated with standing anteroposterior, lateral, and merchant views. Radiographic assessment was performed to assess posterior offset, Insall Salvati ratio, Blackburne, PP angle, Patella thickness,
Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor bone quality, surgical approach and cementless implants. The association between femoral component size and alignment and the risk of early PFF is not well described. We evaluated radiographic parameters of femoral component sizing and alignment as risk factors for early PFF. From 16,065 primary cementless THA, we identified 66 cases (0.41%) of early PFF (<90 days from index THA) at a single institution between 2016–2020. The stem was unstable and revised in all cases. We matched 60 cases of early PFFs (2:1) to 120 controls based on femoral component model, offset, surgical approach, age, BMI, and sex. Mean age was 67 years; 60% were female. Radiographic assessment of preoperative bone morphology and postoperative femoral component parameters including stem alignment, metaphyseal fill, and medial
Introduction: Total knee replacement has become a common procedure with good clinical results. Today many different designs of the femoral component of bicondylar endoprostheses are offered by industry. The femoral components show similar designs however different angles and length of the cross sections are specific. Because of these design differences the preoperative planning and sparing bone resection are difficult at the revision surgery. The aim of this experimental study was to compare the design of femoral components at their cross section contours to find
In replacing the human knee, we attempt to reproduce the stability of the normal knee so that the knee will feel as close to normal as possible to the patient. To answer the question, “Which features matter?” we must first examine the stability of the normal knee. Compliance and stiffness: Stability is measured as “force-displacement” behavior. That is, a force is applied to the knee and the relative motion is measured. Engineers refer to the curves generated by this type of experiment as “stiffness”. Because stiffness is not a term that orthopaedists like to hear when referring to a knee, the inverse term “compliance” often is used. Ligament stress-strain: The force-displacement test for ligaments is called a “stress-strain” curve and shows three regions of force-displacement response. Early in loading a small force causes considerable displacement. This is called the “toe region” of the curve. After a certain amount of displacement, the ligament enters the “elastic region” of the curve and becomes markedly more stiff. Finally, if enough force is applied, the ligament begins to fail at its “yield point”. Ligaments “live” in the toe region of the stress-strain curve. This can be seen clinically when, in response to varus-valgus and anteroposterior stress, the tibia moves relative to the femur until it is stopped by tension in the ligament. This is the ligament moving from the toe region into the elastic region. Compliance of the knee: In a number of studies done in the 1970s, the compliance of the knee was found to be least to both varus-valgus and anteroposterior loads in full extension. In flexion, compliance increases particularly to varus-valgus stress. This implies that the ligamentous structures about the knee are most tight in extension and become more lax in flexion. When external load is applied to the knee, either in the form of muscle contraction or bearing weight, the compliance of the knee decreases (i.e., it becomes more stiff and more stable). Loading will decrease the tension in the ligaments, yet the knee is less compliant. The only way this can happen is by the geometry of the surfaces imparting the stability. The conclusion from these studies is that the human knee, when moving in the usual plane of motion, is stabilised by the geometry of the surfaces, or the congruency of the femur and tibia. Ligaments are recruited to limit motion when forces outside the plane of motion (“out-of-plane” loads) are applied to the knee. These loads move the knee ligaments from the toe region into the elastic region of their stress-strain curve. Two kinds of total knee prosthesis design: Most total knees are designed to have little or no
This study looks at the long-term outcome and morbidity following non-operative management of both-columns fractures (BCF) with secondary