Objectives. All-suture anchors are increasingly used in rotator
Re-rupture rates after rotator
Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator
Tendons mainly consist of collagen in order to withstand high tensile forces. Compared to other, high turnover tissues, cellularity and vascularity in tendons are low. Thus, the natural healing process of tendons takes long and can be problematic. In case of injury to the enthesis, the special transition from tendon over cartilage to bone is replaced by a fibrous scar tissue, which remains an unsolved problem in rotator
Objectives. Platelet-rich fibrin matrix (PRFM) has been proved to enhance tenocyte proliferation but has mixed results when used during rotator
The purpose of the this survey study was twofold: 1) to examine different aspects of satisfaction with post-operative care in injured workers who have undergone rotator cuff surgery and 2) to examine the relationship between receiving a newly implemented summary report and the overall satisfaction with surgery and recovery. The clinical communication summary report was given to injured workers following their review assessment to share with the family doctor or other health care providers. The form indicated a need for further assessments or investigations and return to work recommendations. The study involved using a satisfaction survey that examined different aspects of follow-up visit and workers’ opinion about their understanding of the nature of surgery, their progress, clinical management, and usefulness of the newly implemented summery report. Eighty patients completed the questionnaire (mean age: 54 (8), 62(78%) males, of whom 26 (34%) had a rotator cuff decompression and 31 (40%) had a rotator
Though retear rates following rotator
The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder abduction brace (SAB) after shoulder surgery, revealing that the brace adversely affected gait kinematics with an increase in the risk of falls. The main purpose of the study was to investigate the influence of SAB on gait parameters in patients undergoing shoulder surgery. Patients undergoing elective shoulder surgery (arthroscopic rotator
Background. High re-rupture rates following repairs of rotator cuff tears (RCTs) have resulted in the increased use of repair grafts to act as temporary scaffolds to support tendon healing. It has been estimated that thousands of extracellular matrix repair grafts are used annually to augment surgical repair of rotator cuff tears. The only mechanical assessment of the suitability of these grafts for rotator
Summary Statement. Tendon-bone interface becomes matured with the perforating fiber and the cells striding over the bone area. We suggest that both “perforating fiber” and “cell stride” could play a crucial role in regeneration after rotator
Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator
This study aims to investigate the mechanical properties of a rotator
Glutamate regulates the expression of apoptosis-related genes and triggers the apoptosis of fibroblasts in rotator cuff tendons. Subacromial bursitis is always accompanied by symptomatic rotator cuff tear (RCT). However, no study has been reported on the presence of glutamate in subacromial bursa and on its involvement of shoulder pain in patients who had RCT. The purposes of this study were to determine whether the glutamate expression in subacromial bursa is associated with the presence of RCT and with the severity of shoulder pain accompanying RCT. Subacromial bursal tissues were harvested from patients who underwent arthroscopic rotator
Obesity is associated with poor outcomes and increased risk of failure after rotator
The treatment of massive chronic tears is problematic. The re-tear rate following surgery for extensive cuff tears remains high, and there is little consensus regarding optimum treatment. To investigate the outcome of a cohort of patients who had open repair of an extensive cuff tear using the Leeds Kuff patch as an augment. A retrospective cohort study of consecutive patients with a massive cuff tear who had surgery in our regional elective orthopaedic centre over a two year period from January 2015 to Dec 2016. All patients followed identical rehabilitation protocols, supervised by physiotherapists with an interest in the shoulder. Outcomes assessment was undertaken at a minimum of 12 months by a registrar or physiotherapist who was not part of the treating team. Pre-op data collection included; range of motion, pain score, Oxford shoulder score (OSS), assessment of muscle atrophy on MRI. Data collection was completed in 15 patients. The mean age was 62 yrs (56 – 75). The mean pre-op OSS was 22, improving to a mean of 43. The range of motion and pain score improved. There were no intra-operative complications. One patient required a second surgery for evacuation of a haematoma at 10 days post op. One patient had an obvious re-tear at 4 months. Open rotator
Surgical repair of rotator cuff tears have high failure rates (20–70%), often due to a lack of biological healing. Augmenting repairs with extracellular matrix-based scaffolds is a common option for surgeons, although to date, no commercially available product has proven to be effective. In this study, a novel collagen scaffold was assessed for its efficacy in augmenting rotator
Introduction. Rotator cuff healing after an arthroscopic repair is discussible because of the high incidence of failures. Among biologic augmentations currently used, platelet-rich plasma (PRP) is one of the most applied, supposed to enhance and accelerate the healing process in different musculoskeletal disorders. However, the evidence supporting its successful administration is still lacking, especially in the field of the rotator
Treatment of massive rotator cuff tears can be challenging. Previous studies with irreparable rotator cuff tears showed good clinical results of tendon healing with the arthroscopic insertion of a protective biodegradable spacer balloon filled with saline solution between the repaired tendon and the acromion [1,2], but so far no scientific evidence has showed how the device alters pressures over the repaired tendon. This biomechanical study investigated the effects of a spacer inserted in the subacromial space on pressures over the
Summary Statement. This study describes the design and preliminary in vitro testing of a novel patch for the repair of rotator cuff tendon tears. The laminated design incorporates woven and electrospun components. The woven element provides the patch with excellent mechanical strength and the electrospun layer improves cell attachment and promotes cell orientation and diferentiation. Introduction. Aligned nanofibrous electrospun scaffolds have been previously proposed as ideal scaffolds for tendon repair, replicating the anisotropy of tendon and providing a biomimetic design to encourage tissue regeneration (Hakimi et al., 2012). However, such scaffolds are still limited in terms of mechanical properties. This paper presents the design of a novel patch for rotator
It is not often that the patient, surgeon and hospital management are happy about the same service. However, day-case surgery is an exception, as it has well recognised cost-effectiveness. The new day-surgical shoulder arthroscopy service was audited from its commencement in August 2008 until April 2010. The objectives were to see if patients were going home the same day. All data was gathered retrospectively via the hospital's online database and the patients' notes were collected. An Excel database was created. From August 2008 to April 2010, a total of 41 arthroscopies were performed on 41 patients. Consultant K.A. was the operator in each case. In all cases, an interscalene nerve block was attempted by a consultant anaesthetist. All patients received endotracheal intubation and they were placed in a ‘beach-chair’ position. 49% of patients were male and 51% female. Age range was from 17-70 and the average age was 51 years. 66% underwent a sub-acromial decompression and the remainder had a