Summary Statement.
Autologous bone graft has been used in the treatment of complex bone defects for more than a century. Morbidity associated with the harvest of this bone graft has led orthopaedic surgeons to seek alternative therapies in the treatment of long bone non-unions. The aim of this study was to determine whether the use of demineralised bone matrix as a bone healing adjunct improves clinical outcomes in adult patients with long bone non-union. A systematic search was carried out of the peer-reviewed English language literature to identify all relevant studies. The search strategy returned a total of 47 studies. Five of these studies were relevant to the research question. The studies were critically assessed and where appropriate combined in a meta-analysis. 4 non-comparative studies and one comparative study were reviewed. An overall estimate of the rate of union for the five studies was 86% (95%CI: 71–94%). The one comparative study demonstrated the relative risk (RR) of healing was not significantly better than in patients treated with autologous bone graft; RR=1.03 (95%CI 0.96–1.12). There are limited data to support the use of demineralised bone matrix in the treatment of long bone non-union.
Background: A common problem achieving lumbar spinal fusion is developing a pseudarthrosis. The current gold standard in achieving fusion is the use of autograft from pelvis or posterior elements of the spine. However the potential limitations of insufficient quantity and donor site morbidity have led to the use of bone graft alternatives such as DBM which contains osteoinductive BMPs. Aims &
Methods: A prospective randomized control trial comparing the effectiveness of
Research in to tendon-bone healing techniques focus on increasing bone growth at the interface such as cell or growth factor (e.g. BMP-2) augmentation.
Re-attachment of tendon to bone is challenging with surgical repair failing in up to 90% of cases. Poor biological healing is common and characterised by the formation of weak scar tissue. Previous work has demonstrated that decellularised allogenic demineralised bone matrix (DBM) regenerates a physiologic enthesis. Xenografts offer a more cost-effective option but concerns over their immunogenicity have been raised. We hypothesised that augmentation of a healing tendon-bone interface with DBM incorporated with autologous mesenchymal stem cells (MSCs) would result in improved function, and restoration of the native enthesis, with no difference between xenogenic and allogenic scaffolds. Using an ovine model of tendon-bone retraction the patellar tendon was detached and a complete distal tendon defect measuring 1 cm was created. Suture anchors were used to reattach the shortened tendon and xenogenic DBM + MSCs (n=5) and allogenic DBM + MSCs (n=5) were used to bridge the defect. Functional recovery was assessed every 3 weeks and DBM incorporation into the tendon and its effect on enthesis regeneration was measured using histomorphometry.Background
Methods
Demineralized bone matrix (DBM) is a natural, collagen-based, well-established osteoinductive biomaterial. Nevertheless, there are conflicting reports on the efficacy of this product. The purpose of this study was to evaluate whether DBM collagen structure is affected by particle size and can influence DBM osteoinductivity. Sheep cortical bone was ground and particles were divided in three fractions with different sizes, defined as large (L, 1–2 mm), medium (M, 0.5–1 mm), and small (S, < 0.5 mm). After demineralization, the three DBM samples were characterized by DTA analysis, XRD, ICP-OES, and FTIR. Data clearly showed a particle size-dependent alteration in collagen structure, with DBM-M being altered but not as much as DBM-S. The
The purpose of this study was to understand the effects of terminal sterilisation and residual calcium on human demineralised bone matrix (DBM) in ectopic bone formation in nude rat. The intramuscular implantation of human DBM prepared by the Queensland Bone Bank (QBB) from four donors into eight male athymic rats was used to assess osteoinductivity. The DBM contained different levels of residual calcium and treated with or without gamma-irradiation at 11kGy. At 6 weeks post-implantation, calcium deposition was assessed by manual palpitation and radiological imaging. Tissue morphology and cellular interactions was analysed using various histological staining methods whilst protein expression of anabolic and catabolic biomarkers were examined through immunohistochemistry. All results were then analysed in qualitative, semi-quantitative and quantitative manners and tested for statistical significance. Bone formation was observed in all specimens at the gross level. This was confirmed by histology which revealed bony capsules surrounded by soft tissue in the muscle pockets and differences in tissue components. On a cellular level, variations in osteoclast expression were found between the two groups as well as amongst individual donors through statistical analysis which resulted in an imbalance of the expression of anabolic and catabolic markers. Furthermore, a positive relationship between residual calcium and new bone formation in gamma irradiated DBM samples was found. To date, no studies have compared the effect of calcium in gamma irradiated DBM. Our results suggest that gamma irradiation even at low doses and residual calcium may affect new bone formation. Taken together, this study stresses the importance of selecting ideal conditions for graft processing and the need to identify an optimal level of irradiation and remaining calcium levels that confers a balance between osteoinductivity and sterility.
There is published evidence of the efficacy of DBM in animal spine models, but at present there is scanty evaluation of its use in the human spine in routine clinical practice. The purpose of our pilot study has been to observe the radiological evidence of fusion rates in lumbar spine transverse process fusions, using DBM.
This findings of this study have led us to design a randomised prospective study which will compare using stringent experimental design the use of DBM with using the more traditional autologous graft.
Current bone grafts include allograft and autografts, both of which have limitations. Tissue engineering biotechnology has shown considerable promise in improving grafts. A competent graft material should ideally have osteoconductive and osteoinductive properties and comprise of bone forming cells and osteoinductive growth factors. In this study, we have evaluated the in vitro formation of bone and have used human demineralised bone matrix [DBM] and human insoluble collagenous matric [ICM] as scaffolds for mesenchymal stem cells [MSCs] and osteogenic protein [OP-1]. The objective was to determine whether combined addition of OP-1 and MSCs resulted in a superior bone graft substitute by improving the inherent osteoinductive property. DBM and ICM were prepared and combined with rhOP [1.4 mg/0.25 mg of bone] and MSCs [1 x 105/ ml]. Statistically significant differences in MSC proliferation were seen between materials with and without OP-1 [P<
0.05}, n=8] in DBM on day 1, and both DBM and ICM on day 7 and 14. Enhanced osteogenic differentiation was observed in the presence of OP-1 when compared to DBM alone and on DBM and ICM with OP-1. In conclusion MSCs and OP-1 can be seeded together on DBM and ICM and Von Kossa staining and X-ray analysis confirmed in vitro de novo bone formation, with DBM + MSCs + OP-1 being more successful in this regard.
Aims.
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article:
A literature review of bone graft substitutes for spinal fusion was undertaken from peer reviewed journals to form a basis for guidelines on their clinical use. A PubMed search of peer reviewed journals between Jan 1960 and Dec 2009 for clinical trials of bone graft substitutes in spinal fusion was performed. Emphasis was placed on RCTs. Small and duplicated RCTs were excluded. If no RCTs were available the next best clinical evidence was assessed. Data were extracted for fusion rates and complications. Of 929 potential spinal fusion studies, 7 RCTs met the inclusion criteria for BMP-2, 3 for BMP-7, 2 for Tricalcium Phosphate and 1 for Tricalcium Phosphate/Hydroxyapatite (TCP/HA). No clinical RCTs were found for
Introduction.
Aim. To compare a variety of commercially available bone graft substitutes (BGS) in terms of promoting adherence, proliferation and differentiation of osteoprogenitor cells. Materials and methods. A fixed number of porcine mononuclear cells obtained from cancellous bone of the proximal femur was mixed with a standard volume of BGS and then cultured for one week in media followed by two weeks in osteogenic media. BGS included commercially available β-Tricalcium Phosphate (□-TCP), highly porous β-TCP, Hydroxyapatite/Tricalcium phosphate composite, calcium sulphate (CS), Hydroxyapatite (HA),
We have used human Embryonic Stem cells (hESC) and human Mesenchymal Stem Cells (hMSC) in rat models of bone repair in order to assess the efficacy of these cells for treatments of trauma and skeletal diseases. Graft survival is considered to be of key importance to efficacy of these treatments. Therefore the aim of this study was to develop a technique for identifying implanted cells in histological preparations without the need for genetic engineering of the implanted cells. Methods: In our experiments hES and hMSC were pre-differentiated during cell culture towards the osteoblast lineage, and then implanted in a
The success of anterior cruciate ligament reconstruction (ACLR)
depends on osseointegration at the graft-tunnel interface and intra-articular
ligamentization. Our aim was to conduct a systematic review of clinical
and preclinical studies that evaluated biological augmentation of
graft healing in ACLR. In all, 1879 studies were identified across three databases.
Following assessment against strict criteria, 112 studies were included
(20 clinical studies; 92 animal studies). Aims
Materials and Methods
A common situation presenting to the orthopaedic
surgeon today is a worn acetabular liner with substantial acetabular
and pelvic osteolysis. The surgeon has many options for dealing
with osteolytic defects. These include allograft, calcium based
substitutes, demineralised bone matrix, or combinations of these
options with or without addition of platelet rich plasma. To date
there are no clinical studies to determine the efficacy of using
bone-stimulating materials in osteolytic defects at the time of
revision surgery and there are surprisingly few studies demonstrating
the clinical efficacy of these treatment options. Even when radiographs
appear to demonstrate incorporation of graft material CT studies
have shown that incorporation is incomplete. The surgeon, in choosing
a graft material for a surgical procedure must take into account
the efficacy, safety, cost and convenience of that material. Cite this article:
We performed a systematic review of the literature to determine the safety and efficacy of bone morphogenetic protein (BMP) compared with bone graft when used specifically for revision spinal fusion surgery secondary to pseudarthrosis. The MEDLINE, EMBASE and Cochrane Library databases were searched using defined search terms. The primary outcome measure was spinal fusion, assessed as success or failure in accordance with radiograph, MRI or CT scan review at 24-month follow-up. The secondary outcome measure was time to fusion.Objectives
Methods