Advertisement for orthosearch.org.uk
Results 1 - 20 of 59
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 86 - 86
23 Jun 2023
Marin-Peña O
Full Access

Young patients undergoing THA or hip used. HOS and iHOT33 have demonstrated to be useful in hip preservation surgery but never used in THA. The aim of the study was to evaluate long-term clinical outcomes with HOS and iHOT33 in hip arthroscopy and THA. We conducted a retrospective study with prospective data collection of 118 consecutive young patients (<65 y.o.) between 2008 to 2012 who underwent hip arthroscopy or THA. The mean follow-up was 12.05 years. All surgeries were done by the same senior surgeon. PROMs used were iHOT-33 and HOS preoperatively, at one year and 10 years. SPSS Statistics Grad Pack 28.0 software was used for statistical analysis. Arthroscopy Group (57 patients): Mean age 35.36 years. 55.93% were male. iHOT33 mean differential improvement was 24.43 at 1 year, 70,17% exceed MCID and 49,1% SCB. HOS mean differential improvement was 16.26 at one year. 54,38 % patients exceed MCID and 49,36% SCB. At 10 years, iHOT33 mean differential improvement was 14,36 and 12.56 for HOS. Regarding complications, 3 patients underwent THA (5.26%) and 10 (17.54%) continued with groin pain. THA Group (61 patients): Mean age 52,54 years. 55.73% were male. Cementless THA was used in all patients with ceramic on ceramic used in 77%. iHOT33 mean differential improvement was 41,57 at 1 year. 95,08% patients exceed MCID and 85,25% SCB. HOS mean differential improvement was 16.57 points at one year. 85,25% patients exceed MCID and 81,97% SCB. At 10 years, iHOT33 mean differential improvement was 20,15 and 14.12 for HOS. Regarding complications, 1 patient underwent DAIR for infection (1.64%) and 1 dislocation with close reduction (1.64%). iHOT33 or HOS scores should be considered to be used in young active patients after hip preserving surgery or THA, with more predictable results at long-term in THA group


Bone & Joint Research
Vol. 10, Issue 9 | Pages 558 - 570
1 Sep 2021
Li C Peng Z Zhou Y Su Y Bu P Meng X Li B Xu Y

Aims. Developmental dysplasia of the hip (DDH) is a complex musculoskeletal disease that occurs mostly in children. This study aimed to investigate the molecular changes in the hip joint capsule of patients with DDH. Methods. High-throughput sequencing was used to identify genes that were differentially expressed in hip joint capsules between healthy controls and DDH patients. Biological assays including cell cycle, viability, apoptosis, immunofluorescence, reverse transcription polymerase chain reaction (RT-PCR), and western blotting were performed to determine the roles of the differentially expressed genes in DDH pathology. Results. More than 1,000 genes were differentially expressed in hip joint capsules between healthy controls and DDH. Both gene ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analyses revealed that extracellular matrix (ECM) modifications, muscle system processes, and cell proliferation were markedly influenced by the differentially expressed genes. Expression of Collagen Type I Alpha 1 Chain (COL1A1), COL3A1, matrix metalloproteinase-1 (MMP1), MMP3, MMP9, and MMP13 was downregulated in DDH, with the loss of collagen fibres in the joint capsule. Expression of transforming growth factor beta 1 (TGF-β1) was downregulated, while that of TGF-β2, Mothers against decapentaplegic homolog 3 (SMAD3), and WNT11 were upregulated in DDH, and alpha smooth muscle actin (αSMA), a key myofibroblast marker, showed marginal increase. In vitro studies showed that fibroblast proliferation was suppressed in DDH, which was associated with cell cycle arrest in G0/G1 and G2/M phases. Cell cycle regulators including Cyclin B1 (CCNB1), Cyclin E2 (CCNE2), Cyclin A2 (CCNA2), Cyclin-dependent kinase 1 (CDK1), E2F1, cell division cycle 6 (CDC6), and CDC7 were downregulated in DDH. Conclusion. DDH is associated with the loss of collagen fibres and fibroblasts, which may cause loose joint capsule formation. However, the degree of differentiation of fibroblasts to myofibroblasts needs further study. Cite this article: Bone Joint Res 2021;10(9):558–570


Bone & Joint Open
Vol. 2, Issue 11 | Pages 1004 - 1016
26 Nov 2021
Wight CM Whyne CM Bogoch ER Zdero R Chapman RM van Citters DW Walsh WR Schemitsch E

Aims. This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads. Methods. In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth. Results. Overall, 36 mm heads had lower corrosion onset load (p = 0.009) and change in open circuit potential (OCP) during simulated gait with (p = 0.006) and without joint movement (p = 0.004). Discontinuing gait’s joint movement decreased corrosion currents (p = 0.042); however, wear testing showed no significant effect of joint movement on taper damage. In addition, 36 mm heads had greater corrosion area (p = 0.050), but no significant difference was found for maximum linear wear depth (p = 0.155). Conclusion. Larger heads are more susceptible to taper corrosion; however, not due to frictional torque as hypothesized. An alternative hypothesis of taper flexural rigidity differential is proposed. Further studies are necessary to investigate the clinical significance and underlying mechanism of this finding. Cite this article: Bone Jt Open 2021;2(11):1004–1016


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 41 - 41
7 Jun 2023
Jeyapalan R Baker P Jameson S Rangarajan S Kubelka I
Full Access

Elevated synovial leukocyte count is a minor criterion derived from the musculoskeletal infection society (MSIS) widely used in clinical practice for diagnosis of prosthetic joint infection. There is evidence to suggest analysis within 1 hour, preferentially within 30 minutes, of aspiration reduces the risk of ex vivo cell lysis occurring during prolonged transport. Multiple site working is more common practice and the availability of a lab on site to perform these tests is not always possible. We aimed to assess whether we could safely perform synovial leukocyte counts within our cold site in the diagnosis of prosthetic joint infection. We reviewed all orthopaedic synovial fluid aspirates within the lower limb arthroplasty unit from April 2021 – April 2022 performed at South Tees NHS Foundation Trust. We assessed time from aspirate to the lab using electronic data resources. This information was compared with the labs ability to perform a synovial leukocyte count to determine the impact of delays on testing. 110 patients (34.5% hips and 63.6% knees) were identified between two sites. Time from aspirate to lab ranged from 0 mins to 26 hrs 34 mins. Mean time to processing was 3hrs 10 mins. 50% of all samples had a synovial leukocyte count performed. 67% of patients had a cell differential performed. There was no difference in the ability to perform a synovial leukocyte count between samples process in < 2hours vs > 6 hours. We conclude that it is safe practice to perform joint aspirates for the work up of periprosthetic joint infections in sites where no laboratory is immediately available as the delay to processing synovial fluid does not alter the ability to perform a synovial leukocyte count. This study will provide evidence to enable the work up of periprosthetic joint infections in cold centres and therefore reduce the delay in diagnosis and proceeding management


Bone & Joint Open
Vol. 3, Issue 4 | Pages 291 - 301
4 Apr 2022
Holleyman RJ Lyman S Bankes MJK Board TN Conroy JL McBryde CW Andrade AJ Malviya A Khanduja V

Aims. This study uses prospective registry data to compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum. Methods. Data on adult patients who underwent arthroscopic labral debridement or repair between 1 January 2012 and 31 July 2019 were extracted from the UK Non-Arthroplasty Hip Registry. Patients who underwent microfracture, osteophyte excision, or a concurrent extra-articular procedure were excluded. The EuroQol five-dimension (EQ-5D) and International Hip Outcome Tool 12 (iHOT-12) questionnaires were collected preoperatively and at six and 12 months post-operatively. Due to concerns over differential questionnaire non-response between the two groups, a combination of random sampling, propensity score matching, and pooled multivariable linear regression models were employed to compare iHOT-12 improvement. Results. A total of 2,025 labral debridements (55%) and 1,659 labral repairs (45%) were identified. Both groups saw significant (p < 0.001) EQ-5D and iHOT-12 gain compared to preoperative scores at 12 months (iHOT-12 improvement: labral repair = +28.7 (95% confidence interval (CI) 26.4 to 30.9), labral debridement = +24.7 (95% CI 22.5 to 27.0)), however there was no significant difference between procedures after multivariable modelling. Overall, 66% of cases achieved the minimum clinically important difference (MCID) and 48% achieved substantial clinical benefit at 12 months. Conclusion. Both labral procedures were successful in significantly improving early functional outcome following hip arthroscopy, regardless of age or sex. Labral repair was associated with superior outcomes in univariable analysis, however there was no significant superiority demonstrated in the multivariable model. Level of evidence: III. Cite this article: Bone Jt Open 2022;3(4):291–301


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 6 - 6
1 Jun 2016
Ebreo D Felgate H Martinez-Estrada F Donell S Nolan J Clark I
Full Access

Introduction. The biological pathways responsible for adverse reactions to metal debris (ARMD) are unknown. Necrotic and inflammatory changes in response to Co-Cr nanoparticles in periprosthetic tissues may involve both a cytotoxic response and a type IV delayed hypersensitivity response. Our aim was to establish whether differences in biological cascade activation exists in tissues of patients with end-stage OA compared to those with aseptic loosening of a metal on polyethylene (MoP) THR and those with ARMD from metal-on-metal (MoM) THR. Patients & Methods. A microarray experiment (Illumina HT12-v4) was performed to identify the range of differential gene expression between 24 patients across 3 phenotypes: Primary OA (n=8), revision for aseptic loosening of MoP THR (n=8) and ARMD associated with MoM THR (n=8). Results were validated using Taqman Low Density Array (TLDA) selecting the top 36 genes in terms of fold-change (FC)>2 and a significant difference (p<0.05) on ANOVA. Pathways of cellular interaction were explored using Ingenuity IPA software. Results. There is a similar pattern of gene expression between MoP and MoM phenotypes versus primary OA across 33,777 genes. One hundred and thirty significantly differentially expressed genes across 3 phenotypes were identified. Fifteen pathways were associated with differentially expressed genes between MoP and MoM phenotypes. TLDA demonstrated qualitative mirroring of the expression pattern observed in the microarray and consistency in the direction of change for individual genes. Discussion. There were no signature pathways in which multiple genes are differentially expressed such that inferences between the contributions of innate macrophage and adaptive T-cell responses can be made. TIMP3 & MMP12 were consistently identified in 15 pathways that were associated with differential gene expression between MoP and MoM phenotypes. Conclusion. Analyses of the expression of individual genes such as PRG4 (lubricin) have demonstrated patterns that may provide avenues for further research into biomarkers for periprosthetic osteolysis and ARMD


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2020
Wyles CC Maradit-Kremers H Rouzrokh P Barman P Larson DR Polley EC Lewallen DG Berry DJ Pagnano MW Taunton MJ Trousdale RT Sierra RJ
Full Access

Introduction. Instability remains a common complication following total hip arthroplasty (THA) and continues to account for the highest percentage of revisions in numerous registries. Many risk factors have been described, yet a patient-specific risk assessment tool remains elusive. The purpose of this study was to apply a machine learning algorithm to develop a patient-specific risk score capable of dynamic adjustment based on operative decisions. Methods. 22,086 THA performed between 1998–2018 were evaluated. 632 THA sustained a postoperative dislocation (2.9%). Patients were robustly characterized based on non-modifiable factors: demographics, THA indication, spinal disease, spine surgery, neurologic disease, connective tissue disease; and modifiable operative decisions: surgical approach, femoral head size, acetabular liner (standard/elevated/constrained/dual-mobility). Models were built with a binary outcome (event/no event) at 1-year and 5-year postoperatively. Inverse Probability Censoring Weighting accounted for censoring bias. An ensemble algorithm was created that included Generalized Linear Model, Generalized Additive Model, Lasso Penalized Regression, Kernel-Based Support Vector Machines, Random Forest and Optimized Gradient Boosting Machine. Convex combination of weights minimized the negative binomial log-likelihood loss function. Ten-fold cross-validation accounted for the rarity of dislocation events. Results. The 1-year model achieved an area under the curve (AUC)=0.63, sensitivity=70%, specificity=50%, positive predictive value (PPV)=3% and negative predictive value (NPV)=99%. The 5-year model achieved an AUC=0.62, sensitivity=69%, specificity=51%, PPV=7% and NPV=97%. All cohort-level accuracy metrics performed better than chance. The two most influential predictors in the model were surgical approach and acetabular liner. Conclusions. This machine learning algorithm demonstrates high sensitivity and NPV, suggesting screening tool utility. The model is strengthened by a multivariable dataset portending differential dislocation risk. Two modifiable variables (approach and acetabular liner) were the most influential in dislocation risk. Calculator utilization in “app” form could enable individualized risk prognostication. Furthermore, algorithm development through machine learning facilitates perpetual model performance enhancement with future data input


Bone & Joint Open
Vol. 5, Issue 6 | Pages 479 - 488
6 Jun 2024
Paksoy A Meller S Schwotzer F Moroder P Trampuz A Imiolczyk J Perka C Hackl M Plachel F Akgün D

Aims

Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients.

Methods

This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 27 - 27
1 Jun 2017
Della Valle C Tetreault M Estrera K Kayupov E Brander C
Full Access

Patients with a painful or failed total joint arthroplasties should be evaluated for periprosthetic joint infection (PJI). The purpose of this study was to determine if patients referred to a tertiary care centre had been evaluated for PJI according to the American Academy of Orthopaedic Surgeons (AAOS) clinical practice guidelines. 113 Patients with painful hip (43) or knee (70) arthroplasties were referred to a single provider by orthopaedic surgeons outside our practice between 2012 and 2014. We retrospectively evaluated the workup by referring physicians, including measurement of serum erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), performance of a joint aspiration if these values were abnormal, and obtainment of synovial fluid white blood cell (WBC) count, differential, and cultures. Sixty-two of the 113 patients (55%) did not have a workup that followed AAOS guidelines. Serum ESR and CRP were ordered for 64 of the 113 patients (57%). Of 25 patients with elevated inflammatory markers warranting aspiration, 15 (60%) had an aspiration attempted, with synovial fluid WBC, differential, and cultures obtained in 9 of 12 (75%) aspirations that yielded fluid. Of the 62 patients with an incomplete infection workup, 11 (18%) had a bone scan, 6 (10%) a CT scan, and 3 (5%) an MRI. Twelve of the 113 patients (11%) were ultimately diagnosed with PJI, with 5 undiagnosed prior to referral. The AAOS guidelines to evaluate for PJI are frequently not being followed. Improving awareness of these guidelines may avoid unnecessary and costly evaluations and delay in the diagnosis of PJI


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 656 - 661
1 Jul 2024
Bolbocean C Hattab Z O'Neill S Costa ML

Aims

Cemented hemiarthroplasty is an effective form of treatment for most patients with an intracapsular fracture of the hip. However, it remains unclear whether there are subgroups of patients who may benefit from the alternative operation of a modern uncemented hemiarthroplasty – the aim of this study was to investigate this issue. Knowledge about the heterogeneity of treatment effects is important for surgeons in order to target operations towards specific subgroups who would benefit the most.

Methods

We used causal forest analysis to compare subgroup- and individual-level treatment effects between cemented and modern uncemented hemiarthroplasty in patients aged > 60 years with an intracapsular fracture of the hip, using data from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized clinical trial. EuroQol five-dimension index scores were used to measure health-related quality of life at one, four, and 12 months postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1045 - 1051
1 Oct 2023
Turgeon TR Righolt CH Burnell CD Gascoyne TC Hedden DR Bohm ER

Aims

The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components.

Methods

Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)).


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims

The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA).

Methods

A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 758 - 765
12 Oct 2023
Wagener N Löchel J Hipfl C Perka C Hardt S Leopold VJ

Aims

Psychological status may be an important predictor of outcome after periacetabular osteotomy (PAO). The aim of this study was to investigate the influence of psychological distress on postoperative health-related quality of life, joint function, self-assessed pain, and sports ability in patients undergoing PAO.

Methods

In all, 202 consecutive patients who underwent PAO for developmental dysplasia of the hip (DDH) at our institution from 2015 to 2017 were included and followed up at 63 months (SD 10) postoperatively. Of these, 101 with complete data sets entered final analysis. Patients were assessed by questionnaire. Psychological status was measured by Brief Symptom Inventory (BSI-18), health-related quality of life was raised with 36-Item Short Form Survey (SF-36), hip functionality was measured by the short version 0f the International Hip Outcome Tool (iHOT-12), Subjective Hip Value (SHV), and Hip Disability and Outcome Score (HOS). Surgery satisfaction and pain were assessed. Dependent variables (endpoints) were postoperative quality of life (SF-36, HOS quality of life (QoL)), joint function (iHOT-12, SHV, HOS), patient satisfaction, and pain. Psychological distress was assessed by the Global Severity Index (GSI), somatization (BSI Soma), depression (BSI Depr), and anxiety (BSI Anx). Influence of psychological status was assessed by means of univariate and multiple multivariate regression analysis.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 15 - 15
1 Oct 2019
Plate JF Ryan SP Black C Howell CB Jiranek WA Bolognesi MP Seyler TM
Full Access

Introduction. Alternative payment models for total hip arthroplasty (THA) were initiated by the Center for Medicare and Medicaid Services (CMS) to decrease overall healthcare cost by optimizing healthcare delivery. The associated shift of financial risk to participating institutions has been criticized to introduce patient selection in order to avoid potentially high cost of care. This study aimed to evaluate the impact of the Comprehensive Care for Joint Replacement (CJR) model on patient selection, care delivery and hospital costs at a single care center. Methods. This is a retrospective review of THA patient from July 2015-December 2017 was performed. Patient were stratified by insurance type (Medicare and commercial insurance) and whether care was provided before or after implementation of the CJR bundle. Patient age, gender, and BMI, as well as Elixhauser comorbidities and ASA scores were analyzed. Delivery of care variables including surgery duration, discharge disposition, length of stay, and direct hospital costs were compared before and after CJR implementation. Results. 751 THA patients (273 Medicare and 478 Commercial Insurance) were evaluated before (29%) and after (71%) CJR bundle implementation. There was no difference in patient demographics (age, gender, or BMI); however, commercially insured patients had less Elxihauser comorbidies pre-bundle (p=0.033). After CJR implementation length of stay (p=0.010) for Medicare patients was reduced with a trend toward discharge to home (p=0.019). However, surgical time and OR service time as well as direct hospital costs were similar before and after the CJR bundle initiation. Conclusions. There was no differential patient selection after CJR bundle implementation, and value-based metrics (surgical time, OR service time) were not affected. Patients were discharged sooner and more often to home. However, overall direct hospital expenses remained unchanged revealing that any cost savings were for insurance providers, not participating hospitals. For any tables or figures, please contact the authors directly


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims. The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Materials and Methods. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). Results. Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. Conclusion. Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426–434


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1025 - 1031
1 Sep 2022
Thummala AR Xi Y Middleton E Kohli A Chhabra A Wells J

Aims

Pelvic tilt is believed to affect the symptomology of osteoarthritis (OA) of the hip by alterations in joint movement, dysplasia of the hip by modification of acetabular cover, and femoroacetabular impingement by influencing the impingement-free range of motion. While the apparent role of pelvic tilt in hip pathology has been reported, the exact effects of many forms of treatment on pelvic tilt are unknown. The primary aim of this study was to investigate the effects of surgery on pelvic tilt in these three groups of patients.

Methods

The demographic, radiological, and outcome data for all patients operated on by the senior author between October 2016 and January 2020 were identified from a prospective registry, and all those who underwent surgery with a primary diagnosis of OA, dysplasia, or femoroacetabular impingement were considered for inclusion. Pelvic tilt was assessed on anteroposterior (AP) standing radiographs using the pre- and postoperative pubic symphysis to sacroiliac joint (PS-SI) distance, and the outcomes were assessed with the Hip Outcome Score (HOS), International Hip Outcome Tool (iHOT-12), and Harris Hip Score (HHS).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1201 - 1209
1 Sep 2011
Peng K Hsu W Shih H Hsieh C Huang T Hsu RW Chang P

In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requiring revision for polyethylene wear) and C (n = 15, requiring revision due to aseptic loosening) to verify the involvement of the identified targets in aseptic loosening. When compared with Groups A and B, Group C patients exhibited significant up-regulation of transthyretin and superoxide dismutase 3, but down-regulation of glutathione peroxidase 2 in their hip synovial fluids. Also, higher levels of superoxide dismutase 2 and peroxiredoxin 2, but not superoxide dismutase 1, catalase and glutathione perioxidase 1, were consistently detected in the hip capsules of Group C patients. We propose that dysregulated reactive oxygen species-related enzymes may play an important role in the pathogenesis and progression of aseptic loosening after THR


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 69 - 69
1 Oct 2018
Muratoglu OK Chaudhary M Varadarajan KM
Full Access

Introduction. Ceramic heads are used in hip revision surgery to mitigate corrosion concerns. Manufacturers recommend using a pristine titanium sleeve in conjunction with a well-fixed metal stem to prevent early failure of the ceramic head. However, the influence of impact force, head size, and sleeve offset on pull-off strength and seating displacement of a revision head assembly is not fully understood. Therefore, the purpose of this study was to investigate the pull-off strength and displacement of commercially available revision ceramic heads and titanium taper sleeve offsets (BIOLOX OPTION, CeramTec GmbH, Plochingen, Germany) while covering a range of clinically relevant impaction forces. Methods. Two head sizes (28 mm, n = 12 and 36 mm, n = 12) and two taper adapter sleeve offsets (small, n = 12 and extra-large, n = 12) were tested in this study. A dynamic impaction rig was constructed to seat the head, sleeve, and stem assembly (Fig. 1). Consistent impaction forces were achieved by dropping a hammer fixed to a lever arm from a pre-determined height onto a standard impactor instrumented with a piezoelectric force sensor (PCB Piezotronics Inc.). Axially applied forces of 2 kN and 6 kN were used to cover a range of typical impaction forces. Three non-contact differential variable reluctance transducers (LORD Sensing Systems) were used to track the displacement of the head relative to the stem. Subsequently, samples were transferred to a servo hydraulic testing machine, and a pull-off test was carried out per ISO 7206–10 to measure the disassembly force. Results. For all head and sleeve combinations assembled at 6 kN, pull-off forces and assembly displacements were over two times the values measured at 2 kN. As expected, an increased assembly force resulted in increased pull-offs and displacements. Head size did not play a significant role on measured outcomes. Regarding sleeve offsets, at assembly of 6 kN mean pull-off forces for extra-large sleeves were reduced by approximately 25% relative to small sleeves (Fig 2). However, at a 2 kN assembly, sleeve offsets did not appear to influence pull-off forces. Discussion. This study assessed the effect of impact assembly force, head size, and sleeve offset on pull-off strength and seating displacement of revision ceramic heads. The data suggests assembly force and sleeve offset may influence the pull-off strength and seating displacement of modular heads used in revision hip arthroplasty. Mean pull-off forces for revision heads were comparable in magnitude and trend to previous studies assessing the linear relationship between assembly force and pull-off force in primary heads (Krull et al., 2017, Rehmer et al., 2012). Lower pull-off forces were observed for extra-large sleeves when compared to small sleeves, indicating, decreased contact at the sleeve and stem interface for extra-large offsets may play a role in reducing pull-off forces. Acknowledgment:. The authors would like to thank CeramTec GmbH (Plochingen, Germany) for providing the head, sleeve, and stem implants. For any figures or tables, please contact authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 140 - 144
1 Feb 2008
Nagoya S Kaya M Sasaki M Tateda K Yamashita T

We evaluated triple-phase bone scintigraphy in the differential diagnosis of peri-prosthetic infection in 46 patients with a total hip replacement or bipolar hemiarthroplasty who were due for revision surgery. There were 18 men and 28 women, with a mean age at operation of 64.6 years (28 to 81). We defined peri-prosthetic infection as an increased uptake of radioisotope in all the phases of triple-phase bone scintigraphy and validated these results against the histological and/or microbiology results in every case. The positive and negative predictive values for the presence of infection were 83% and 93%, respectively. The diagnostic sensitivity was 88% and the specificity was 90%. This study indicates that triple-phase bone scintigraphy is a useful tool in the detection of peri-prosthetic infection and offers a cost-effective method of screening


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 4 - 4
1 Oct 2018
May C Bixby S Kim YJ Millis MB Heyworth B
Full Access

Introduction. Ascertaining the etiology of hip pain in young patients can be challenging. Osteoid osteoma about the hip has only been described in case reports and small case series in this sub-population. This study assessed the clinical course, radiologic findings, and treatment approaches in a large series of pediatric osteoid osteoma cases about the hip. Potential diagnostic and treatment pitfalls were identified. Methods. A single-center tertiary care departmental database was queried for all cases of osteoid osteoma seen between Jan 1, 2003 and December 31, 2015. Medical records were reviewed to identify those with lesions identified within or around the hip joint. Clinical, demographic, and radiologic data were analyzed. Results. Fifty children and adolescents (56% female, mean age 12.4 years, range 3–19 years) were identified with osteoid osteoma about the hip. The femoral neck was the most common lesion location (38%), and pain in the hip was the most common presenting chief complaint (60%). Night pain (90%) and symptom relief with NSAIDs (88%) were extremely common, though not universally reported. Sclerosis and/or cortical thickening was visible in 58% of radiographs, though a lucent nidus was visible in only 42%. Thirty patients (60%) underwent MRI, 27 of which were available for review, with focal peri-lesional edema as a universal finding. Amongst intracapsular lesions (n=17, 63%), common findings included medial retinacular thickening (33%), synovitis (45%) and effusion (76%). In the 43 patients (48%) who underwent CT, a diagnostic lucent nidus was a universal finding. Initial alternative diagnoses were recorded in 46% of cases, including, in order of decreasing frequency, femoro-acetabular impingement, minor trauma, hip synovitis, ‘growing pain’, stress fracture, and infection. Abnormal hip range of motion, positive impingement signs, and global synovitis on MRI scan were found to be associated with alternative diagnosis. On multivariate regression analysis, only abnormal hip ROM was independently predictive of alternative diagnosis. Delay in diagnosis of >6 months was seen in 43% of patients. Three patients underwent preceding operative procedures for other hip diagnoses, but had persistent hip pain until the osteoid osteoma was treated. Forty-one patients (82%) ultimately underwent radiofrequency ablation (RFA), and 1 open osteoid osteoma resection was performed. Of those who underwent RFA, 93% achieved complete symptom resolution, with 2 of 3 patients without symptom resolution undergoing revision RFA procedure, 1 of which led to symptom resolution. Complications of treatment included 1 case of deep infection along an RFA track, requiring operative debridement, 1 case of transient weakness and paresthesias in the involved extremity, and 1 case of fracture at the RFA site, requiring ORIF. Conclusions. Alternative andelayed diagnoses are common in osteoid osteoma about the hip, with femoro-acetabular impingement representing the most common alternative initial diagnosis in our series. While varying presenting complaints and nonspecific MRI findings may contribute to diagnostic uncertainty, night pain was present in the vast majority of cases and CT scans provided definitive diagnosis in all patients who received them. As increasing numbers of young, active patients are being evaluated for various causes of hip pain, such as femoro-acetabular impingement, osteoid osteoma should not be overlooked in the differential diagnosis of pain about the hip