Periprosthetic femoral fractures are increasingly seen in recent years, adding considerable burden to the National Health Service. These require complex revision or fixation and prolonged post-operative care, with significant morbidity with associated costs. The purpose of this study was to assess whether the size of femoral cement mantle is associated with periprosthetic femoral fractures (PPF). This retrospective study was carried out on a cohort of 49 patients (Fracture Group - FG) who previously had a revision procedure following a proximal PPF between 2010 and 2021. Inclusion criteria – all primary cemented total hip replacements (THR). Exclusion criteria – complex primary THR, any implant malposition that required early revision surgery or any pre-fracture stem loosening. The antero-posterior (AP) radiographs from this cohort of patients were assessed and compared to an age, sex, time since THR-matched control group of 49 patients without PPF (Control Group - CG).
Aims. Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. Methods. A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method). Results. Mean impingement-free flexion of patients with mixed-type FAI (110° (SD 8°)) and patients with pincer-type FAI (112° (SD 8°)) was significantly (p < 0.001) lower compared to the control group (125° (SD 13°)). The frequency of extra-articular subspine impingement was significantly (p < 0.001) increased in patients with pincer-type FAI (57%) compared to cam-type FAI (22%) in 125° flexion. Bony impingement in maximal flexion was located anterior-inferior at femoral four and five o’clock position in patients with cam-type FAI (63% (10 of 16 hips) and 37% (6 of 10 hips)), and did not involve the cam deformity. The cam deformity did not cause impingement in maximal flexion. Conclusion. Femoral impingement in maximal flexion was located anterior-inferior
The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort. We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time. 160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four. This technique allows instant
Background. Thigh pain following a well-fixed total hip arthroplasty (THA) remains problematic and a source of patient dissatisfaction. The purpose of this study is to evaluate if the development of
The risk factors for abnormal spinopelvic mobility (SPM), defined as an anterior rotation of the spinopelvic tilt (∆SPT) ≥ 20° in a flexed-seated position, have been described. The implication of pelvic incidence (PI) is unclear, and the concept of lumbar lordosis (LL) based on anatomical limits may be erroneous. The distribution of LL, including a unusual shape in patients with a high lordosis, a low pelvic incidence, and an anteverted pelvis seems more relevant. The clinical data of 311 consecutive patients who underwent total hip arthroplasty was retrospectively analyzed. We analyzed the different types of lumbar shapes that can present in patients to identify their potential associations with abnormal pelvic mobility, and we analyzed the potential risk factors associated with a ∆SPT ≥ 20° in the overall population.Aims
Methods
The Nottingham Hip Fracture Score (NHFS) is validated to predict mortality after fragility neck of femur fractures (NOF). Risk stratification supports informed consent, peri-operative optimisation and case prioritisation. With the inclusion of fragility distal femur fractures (DFF) in the BPT, increasing attention is being placed on the outcome of these injuries. Developing on the lessons learnt over the past decades in NOF management is key. This study assesses the validity of the NHFS in predicting mortality after fragility DFFs. A multi-centre study of 3 high volume fragility fracture units was performed via a retrospective analysis of prospectively collected databases. Patients aged 60 years-of-age who presented with AO 33.A/B/C native DFF, or V.3.A/B periprosthetic DFF over an 86-month period between September 2014 and December 2021 and underwent surgical treatment were eligible for inclusion. Open and/or polytrauma (ISS >15) were excluded. All operations were performed or supervised by Consultant Orthopaedic Surgeons and were reviewed peri-operatively by a 7-day MDT. Patients with a NHFS of gt;=5 were stratified into a high-risk of 30-day mortality cohort, with all others being œlow-risk. 285 patients were eligible for inclusion with 92 considered to be low-risk of 30-day mortality, these tended to be younger female patients admitted from their own homes. 30-day mortality was 0% in the low-risk cohort and 6.2% (12/193) in the high-risk group. 1-year mortality was 8.7% (8/92) and 35.7% (69/193) in the low and high-risk groups respectively. Area Under the Curve (AUC) analyses of Receiver Operator Characteristic (ROC) curves demonstrated the greatest ability to predict mortality at 30-days for the high-risk cohort (0.714). The NHFS demonstrates a good ability to predict 30-day mortality in those patients with a NHFS =5 after a surgically managed fragility DFF. With comparable mortality outcomes to those documented from fragility NOF.
Introduction. Limb Length discrepancy after total hip replacement has been reported to happen in 1–27% of cases with differences up to 70mm. Occasionally revision THR has been used to achieve limb length equalisation, especially when patients are symptomatic with hip/back pain, neurologic symptoms or instability. However, in presence of a well-functioning, pain free hip without hip symptoms, revision THR for shortening can lead to problems with decrease in offset or stability. An option in these cases would be a
We have managed 27 patients (16 women and 11 men) with a mean age of 68.4 years (50 to 84), with failed total hip replacement and severe proximal femoral bone loss by revision using a
In 2005, we demonstrated that the polished triple-tapered
C-stem at two years had migrated
Aims. Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with
Aims. The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the
Aims. To evaluate how abnormal proximal femoral anatomy affects different femoral version measurements in young patients with hip pain. Methods. First, femoral version was measured in 50 hips of symptomatic consecutively selected patients with hip pain (mean age 20 years (SD 6), 60% (n = 25) females) on preoperative CT scans using different measurement methods: Lee et al, Reikerås et al, Tomczak et al, and Murphy et al. Neck-shaft angle (NSA) and α angle were measured on coronal and radial CT images. Second, CT scans from three patients with femoral retroversion, normal femoral version, and anteversion were used to create 3D femur models, which were manipulated to generate models with different NSAs and different cam lesions, resulting in eight models per patient. Femoral version measurements were repeated on manipulated femora. Results. Comparing the different measurement methods for femoral version resulted in a maximum mean difference of 18° (95% CI 16 to 20) between the most proximal (Lee et al) and most
Aims. Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods. Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results. Median
Early micromotion of hip implants measured with radiostereometric analysis (RSA) is a predictor for late aseptic loosening. Computed Tomography Radiostereometric Analysis (CT-RSA) can be used to determine implant micro-movements using low-dose CT scans. CT-RSA enables a non-invasive measurement of implants. We evaluated the precision of CT-RSA in measuring early stem migration. Standard marker-based RSA was used as reference. We hypothesised that CT-RSA can be used as an alternative to RSA in assessing implant micromotions. We included 31 patients undergoing Total Hip Arthroplasty (THA).
Aims. Developmental dysplasia of the hip (DDH) describes a pathological relationship between the femoral head and acetabulum. Periacetabular osteotomy (PAO) may be used to treat this condition. The aim of this study was to evaluate the results of PAO in adolescents and adults with persistent DDH. Methods. Patients were divided into four groups: A, adolescents who had not undergone surgery for DDH in childhood (25 hips); B, adolescents who had undergone surgery for DDH in childhood (20 hips); C, adults with DDH who had not undergone previous surgery (80 hips); and D, a control group of patients with healthy hips (70 hips). The radiological evaluation of digital anteroposterior views of hips included the Wiberg angle (centre-edge angle (CEA)), femoral head cover (FHC), medialization,
Revision total hip arthroplasty (rTHA) in the presence of femoral defects can be technically challenging. Reconstruction with long stems is widely accepted as the standard. However long stems can be difficult to insert and can compromise
The aim of the study was to evaluate radiological and clinical outcomes of surgical treatment of developmental dysplasia of the hip (DDH) with Periacetabular Osteotomy (PAO) and to determine the values of radiological parameters allowing us to obtain an optimal clinical result. Radiological evaluation included a standardized AP digital radiograph of the hip joints. Centre edge angle (CEA), medialization,
Previous studies have highlighted differences in the risk of periprosthetic fracture between tapered slip (TS) and composite beam (CB) stems. This biomechanical study explored periprosthetic fractures around these stems and the effect of adding a 16-gauge calcar or diaphyseal wire to TS stems on their resistance to torque. A power analysis determined a sample size of 7 specimens per group, assuming a standard deviation of 14.8 Nm in peak torque, to provide 90% power to detect a difference of at least 30 Nm between groups. Twenty-one TS stems (eight alone, six with calcar wiring, seven with diaphyseal wiring placed 2 cm
Aims. The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods. The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results. There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion. The N-HA-coated stem showed a significantly larger contact area, indicating a
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region,