Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 138 - 140
1 Jan 2012
Jung S Park H Chung J

In distal fibular resection without reconstruction, the stabilising effect of the lateral malleolus is lost. Thus, the ankle may collapse into valgus and may be unstable in varus. Here, we describe a child who underwent successful staged surgical correction of a severe neglected valgus deformity after excision of the distal fibula for a Ewing’s sarcoma


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 15 - 15
1 Nov 2014
Prior C Wellar D Widnall J Wood E
Full Access

Introduction:. Fibular malreduction is a common and important cause of pain after surgical fixation following a syndesmosis injury, but it is unclear which components of malreduction correspond to clinical outcome. Plain radiographs have been shown to be unreliable at measuring malreduction when compared to CT scans. A number of published methods for measuring fibular position rely on finding the axis of the fibula. Elgafy demonstrated that fibular morphology varies greatly, and some studies have demonstrated difficulty finding the fibular axis. Methods:. We developed a new method of measuring the distal fibular position on CT images. We used CT studies in 16 normal subjects. Two assessors independently measured the ankle syndesmosis using the Davidovitch method, and our new protocol for fibular AP position, diastasis and fibular length. Results:. We demonstrated that after statistical analysis (Pearson Product Moment Correlation) our method showed improved inter-observer reliability (r = 0.99 and 0.95 vs 0.59 and 0.78 respectively) for diastasis and AP translation, and improved intra-observer reliability (r = 0.99 and 0.99 vs 0.91 and 0.97 respectively). We found inter and intra observer reliability of 0.80 and 0.91 respectively for fibular length, but were unable to find a novel, accurate method for measuring fibular rotation. Conclusions:. Our method is a new, simple, accurate and reproducible system for measuring the ankle syndesmosis. We believe that this method could be used to assess fibular reduction after obtaining CT images of the uninjured side for comparison


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 19 - 19
1 Nov 2014
Yousaf S Lee C Khan A Hossain N Edmondson M
Full Access

Introduction:. Early stabilization has the potential to expedite early return to function and reduce hospital stay thus reducing cost to health care. A clinical audit was performed to test the hypothesis that early surgical stabilization lowers the rate of soft tissue complications and is not influenced by choice of distal fibular implants used for stabilization of ankle fractures. Methods:. All surgically treated adult patients with isolated unstable ankle fracture were included from April 2012 to April 2013 at a MTC in UK. Patients with poly-trauma were excluded. All patients underwent a standard surgical protocol: aim for early definitive surgical fixation (ORIF) within 24 hours however if significantly swollen than temporary stabilization with an external fixation followed by a staged definitive fixation. Results:. In total 172 consecutive unstable ankle fractures were included in one-year study period. Definitive fixation (ORIF) was achieved in 91% patients with only 9% patients required temporary stabilization with external fixation. Fibular locking plates were used in 59(38%) patients compared to conventional one-third tubular plates in 91(60%) patients. In ORIF group 42% (73) patients were operated within 24 hours of admission whilst 58% (83) under went early fixation after 24–72 hours. At one year follow up complications were recorded in 18(11%) patients including metal irritation requiring removal of implant in 6(4%) patients. Wound complications and deep infection leading to a further surgical procedure in 8(5%) patients. There was no statistical difference between complication rates (p=0.016) in early versus delayed fixation groups. Fibular locking plates were associated with higher soft tissue complications (13%) as compared with conventional plates (2%) (p=0.004). Conclusion:. Our study showed that the timing of the surgery has less influence on the complications of the ankle fracture fixation. However choice of implants requires careful consideration and we suggest caution against use of current fibular locking plates


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1689 - 1696
1 Dec 2020
Halai MM Pinsker E Mann MA Daniels TR

Aims

Preoperative talar valgus deformity ≥ 15° is considered a contraindication for total ankle arthroplasty (TAA). We compared operative procedures and clinical outcomes of TAA in patients with talar valgus deformity ≥ 15° and < 15°.

Methods

A matched cohort of patients similar for demographics and components used but differing in preoperative coronal-plane tibiotalar valgus deformity ≥ 15° (valgus, n = 50; 52% male, mean age 65.8 years (SD 10.3), mean body mass index (BMI) 29.4 (SD 5.2)) or < 15° (control, n = 50; 58% male, mean age 65.6 years (SD 9.8), mean BMI 28.7 (SD 4.2)), underwent TAA by one surgeon. Preoperative and postoperative radiographs, Ankle Osteoarthritis Scale (AOS) pain and disability and 36-item Short Form Health Survey (SF-36) version 2 scores were collected prospectively. Ancillary procedures, secondary procedures, and complications were recorded.