Advertisement for orthosearch.org.uk
Results 1 - 20 of 701
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. Methods. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves. Results. In the base case analysis, surgical fixation with K-wire was more expensive (£29.65 (95% confidence interval (CI) -94.85 to 154.15)) and generated lower QALYs (0.007 (95% CI -0.03 to 0.016)) than moulded casting, but this difference was not statistically significant. The probability of K-wire being cost-effective at a £20,000 per QALY cost-effectiveness threshold was 24%. The cost-effectiveness results remained robust in the sensitivity analyses. Conclusion. The findings suggest that surgical fixation with K-wire is unlikely to be a cost-effective alternative to a moulded cast in adults, following manipulation of a fracture of the distal radius in a theatre setting. Cite this article: Bone Joint J 2022;104-B(11):1225–1233


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims. The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius. Methods. We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score. Results. Long-term outcomes were available for 89 patients (72%). The mean age was 57 years (SD 15) and 68 were female (76%). The median time from injury to corrective osteotomy was nine months (interquartile range (IQR) 6 to 13). At a mean follow-up of six years (1 to 11) the median PRWE score was 22 (IQR 7 to 40), the median QuickDASH score was 11.4 (IQR 2.3 to 31.8), and the median EQ-5D-5L score was 0.84 (IQR 0.69 to 1). The NPS was 69. Multivariate regression analysis showed that the presence of an associated ulnar styloid fracture was the only significant independent factor associated with a worse PRWE score when adjusting for confounding variables (p = 0.004). Conclusion. We found that corrective osteotomy for malunion of the distal radius can result in good functional outcomes and high levels of patient satisfaction. However, the presence of an ulnar styloid fracture may adversely affect function. Level of Evidence: III (cohort study). Cite this article: Bone Joint J 2020;102-B(11):1542–1548


Bone & Joint Open
Vol. 5, Issue 10 | Pages 920 - 928
21 Oct 2024
Bell KR Oliver WM White TO Molyneux SG Graham C Clement ND Duckworth AD

Aims. The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength, range of motion, radiological parameters, healthcare resource use, and cost-effectiveness between the groups. Methods. A prospectively registered (ISRCTN95922938) randomized parallel group trial will be conducted. Elderly patients meeting the inclusion criteria with a dorsally displaced distal radius facture will be randomized (1:1 ratio) to either conservative management (cast without further manipulation) or surgery. Patients will be assessed at six, 12, 26 weeks, and 52 weeks post intervention. The primary outcome measure and endpoint will be the Patient-Rated Wrist Evaluation (PRWE) at 52 weeks. In addition, the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH), EuroQol five-dimension questionnaire, pain score (visual analogue scale 1 to 10), complications, grip strength (dynamometer), range of motion (goniometer), and radiological assessments will be undertaken. A cost-utility analysis will be performed to assess the cost-effectiveness of surgery. We aim to recruit 89 subjects per arm (total sample size 178). Discussion. The results of this study will help guide treatment of dorsally displaced distal radial fractures in the elderly and assess whether surgery offers functional benefit to patients. This is an important finding, as the number of elderly distal radial fractures is estimated to increase in the future due to the ageing population. Evidence-based management strategies are therefore required to ensure the best outcome for the patient and to optimize the use of increasingly scarce healthcare resources. Cite this article: Bone Jt Open 2024;5(10):920–928


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


Aims. Torus fractures of the distal radius are the most common fractures in children. The NICE non-complex fracture guidelines recently concluded that bandaging was probably the optimal treatment for these injuries. However, across the UK current treatment varies widely due to a lack of evidence underpinning the guidelines. The Forearm Fracture Recovery in Children Evaluation (FORCE) trial evaluates the effect of a soft bandage and immediate discharge compared with rigid immobilization. Methods. FORCE is a multicentre, parallel group randomized controlled equivalence trial. The primary outcome is the Wong-Baker FACES pain score at three days after randomization and the primary analysis of this outcome will use a multivariate linear regression model to compare the two groups. Secondary outcomes are measured at one and seven days, and three and six-weeks post-randomization and include the Patient Reported Outcome Measurement Information System (PROMIS) upper extremity limb score, EuroQoL EQ-5D-Y, analgesia use, school absence, complications, and healthcare resource use. The planned statistical and health economic analyses for this trial are described here. The FORCE trial protocol has been published separately. Conclusion. This paper provides details of the planned analyses for this trial, and will reduce the risks of outcome reporting bias and data driven results. Cite this article: Bone Joint Open 2020;1-6:205–213


Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1550 - 1556
1 Dec 2019
Mc Colgan R Dalton DM Cassar-Gheiti AJ Fox CM O’Sullivan ME

Aims. The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Patients and Methods. Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were included. Results. In 2008 Kirschner-wire (K-wire) fixation accounted for 59% of operations for fractures of the distal radius, and plate fixation for 21%. In 2017, the rate of K-wire fixation had fallen to 30%, and the proportion of patients who underwent plate fixation had risen to 62%. Conclusion. There is an increasing trend towards open reduction and internal fixation for fractures of the distal radius in Ireland. This has been accompanied by a decrease in popularity for K-wire fixation. DRAFFT did not appear to influence trends in the management of fractures of the distal radius in Ireland. Cite this article: Bone Joint J 2019;101-B:1550–1556


Bone & Joint Research
Vol. 10, Issue 12 | Pages 820 - 829
15 Dec 2021
Schmidutz F Schopf C Yan SG Ahrend M Ihle C Sprecher C

Aims. The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). Methods. A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability. Results. The CBT could accurately be determined on XRs and highly correlated to those determined on CT scans (r = 0.87 to 0.93). The CBTavg index of the XRs significantly correlated with the BMD measured by DXA (r = 0.78) and HR-pQCT (r = 0.63), as did the CBTg index with the DXA (r = 0.55) and HR-pQCT (r = 0.64) (all p < 0.001). A high correlation of the BMD and CBT was observed between paired specimens (r = 0.79 to 0.96). The intra- and inter-rater reliability was excellent (ICC 0.79 to 0.92). Conclusion. The cortical index (CBTavg) at the distal radius shows a close correlation to the local BMD. It thus can serve as an initial screening tool to estimate the local bone quality if quantitative BMD measurements are unavailable, and enhance decision-making in acute settings on fracture management or further osteoporosis screening. Cite this article: Bone Joint Res 2021;10(12):820–829


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 2 - 2
1 Sep 2014
van der Kaag M Ikram A
Full Access

Aims of study. To assess and compare the functional, radiological and cosmetic results as well as patient satisfaction in patients treated with the IMN Device Vs Volar Locking Plate. Method. All patients who presented to our institution with extra articular distal radius fractures and met the inclusion criteria were invited to take part in the study. The patients were randomly allocated to two groups, those who underwent intramedullary (IMN) distal radius fixation using the Sanoma Wrx Distal radius nail and those who underwent fixation using a volar locking plate. The patients were then followed up at 2 weeks, 6 weeks, 3 months, 6 months and 1 year. The radiological parameters, ie radial height, inclination and tilt were compared as well as the functional outcomes by means of DASH score. The range of motion of the wrist was compared as well as the scar size. Complications were reviewed. Results. We present our early results. Currently we have included 9 patients in the IMN group and 7 patients in the volar plate group with follow-ups longer than 3 months. Results show smaller scars (2.5 vs 6.7cm), comparable flexion and extension (40 vs 40 and 45 vs 40), slight improvements in pronation and supination (80 vs 75 and 85 vs 80) in the IMN compared to the volar plate. Radial and ulnar deviation is comparable. The radiological parameters showed slight improvements in the radial height (2.5 vs 2.2 mm), inclination (3.6 vs 3.2 degrees) and tilt 13,7 vs 12 degrees) with the IMN. Dash scores will be compared at 6 months. Conclusion. Intra medullary nailing of the distal radius seems to compare to volar plating in terms of radiological parameters and rotational stability but has the added benefit of early range of motion, minimal invasive technique, less post op pain and less complications such as tendon irritation. NO DISCLOSURES


Bone & Joint Open
Vol. 3, Issue 7 | Pages 515 - 528
1 Jul 2022
van der Heijden L Bindt S Scorianz M Ng C Gibbons MCLH van de Sande MAJ Campanacci DA

Aims. Giant cell tumour of bone (GCTB) treatment changed since the introduction of denosumab from purely surgical towards a multidisciplinary approach, with recent concerns of higher recurrence rates after denosumab. We evaluated oncological, surgical, and functional outcomes for distal radius GCTB, with a critically appraised systematic literature review. Methods. We included 76 patients with distal radius GCTB in three sarcoma centres (1990 to 2019). Median follow-up was 8.8 years (2 to 23). Seven patients underwent curettage, 38 curettage with adjuvants, and 31 resection; 20 had denosumab. Results. Recurrence rate was 71% (5/7) after curettage, 32% (12/38) after curettage with adjuvants, and 6% (2/31) after resection. Median time to recurrence was 17 months (4 to 77). Recurrences were treated with curettage with adjuvants (11), resection (six), or curettage (two). Overall, 84% (38/45) was cured after one to thee intralesional procedures. Seven patients had 12 months neoadjuvant denosumab (5 to 15) and sixmonths adjuvant denosumab; two recurred (29%). Twelve patients had six months neoadjuvant denosumab (4 to 10); five recurred (42%). Two had pulmonary metastases (2.6%), both stable after denosumab. Complication rate was 18% (14/76, with 11 requiring surgery). At follow-up, median MusculoSkeletal Tumour Society score was 28 (18 to 30), median Short Form-36 Health Survey was 86 (41 to 95), and median Disability of Arm, Shoulder, and Hand was 7.8 (0 to 58). Conclusion. Distal radius GCTB treatment might deviate from general GCTB treatment because of complexity of wrist anatomy and function. Novel insights on surgical treatment are presented in this multicentre study and systematic review. Intralesional surgery resulted in high recurrence-rate for distal radius GCTB, also with additional denosumab. The large majority of patients however, were cured after repeated curettage. Cite this article: Bone Jt Open 2022;3(7):515–528


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 16 - 16
1 Jul 2012
Granville-Chapman J Hacker A Keightley A Sarkhel T Monk J Gupta R
Full Access

Extensor tendon ruptures have been reported in up to 8.8% of patients after volar plating and long screws have been implicated. The dihedral dorsal surface of the distal radius hinders accurate screw length determination using standard radiographic views (lateral; pronation and supination). A ‘dorsal tangential’ view has recently been described, but has not been validated. To validate this view, we mounted a plate-instrumented sawbone onto a jig. Radiographs at different angles were reviewed independently by 11 individuals. Skyline views clearly demonstrated all screw tips, whereas only 69% of screw tips were identifiable on standard views. With screws 2mm proud of the dorsal surface, skyline views detected 67% of long screws (sensitivity). The best of the standard views achieved only 11% sensitivity. At 4mm long, skyline sensitivity was 85%, compared with 25% for standard views. At 6mm long, 100% of long screws were detected on skylines, but only 50% of 8mm long screws were detected by standard views. Inter and intra-observer variability was 0.97 (p=0.005). For dorsal screw length determination of the distal radius, the skyline view is superior to standard views. It is simple to perform and its introduction should reduce the incidence of volar plate-related extensor tendon rupture


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 49 - 49
7 Nov 2023
Francis J Battle J Hardman J Anakwe R
Full Access

Fractures of the distal radius are common, and form a considerable proportion of the trauma workload. We conducted a study to examine the patterns of injury and treatment for adult patients presenting with distal radius fractures to a major trauma centre serving an urban population. We undertook a retrospective cohort study to identify all patients treated at our major trauma centre for a distal radius fracture between 1 June 2018 and 1 May 2021. We reviewed the medical records and imaging for each patient to examine patterns of injury and treatment. We undertook a binomial logistic regression to produce a predictive model for operative fixation or inpatient admission. Overall, 571 fractures of the distal radius were treated at our centre during the study period. A total of 146 (26%) patients required an inpatient admission, and 385 surgical procedures for fractures of the distal radius were recorded between June 2018 and May 2021. The most common mechanism of injury was a fall from a height of one metre or less. Of the total fractures, 59% (n = 337) were treated nonoperatively, and of those patients treated with surgery, locked anterior-plate fixation was the preferred technique (79%; n = 180). The epidemiology of distal radius fractures treated at our major trauma centre replicated the classical bimodal distribution described in the literature. Patient age, open fractures, and fracture classification were factors correlated with the decision to treat the fracture operatively. While most fractures were


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 51 - 51
1 Jul 2020
Tohme P Hupin M Nault M Stanciu C Beausejour M Blondin-Gravel R Désautels É Jourdain N
Full Access

Premature growth arrests are an infrequent, yet a significant complication of physeal fractures of the distal radius in children and adolescents. Through early diagnosis, it is possible to prevent clinical repercussions of the anatomical and biomechanical alterations of the wrist. Their true incidence has not been well established, and there exists no consensual systematic monitoring plan for minimising its impacts. The main objective was to evaluate the prevalence of growth arrests after a physeal distal radius fracture. The secondary objective was to identify risk factors in order to better guide clinicians for a systematic follow-up. All patients seen between 2014–2016 in a tertiary orthopaedic clinic were retrospectively reviewed. Inclusion criteria were (one) a physeal fracture of the distal radius (two) adequate clinical/radiological follow-up. Descriptive, Chi-square and binary logistic regression analyses were carried out using SPSS software. One hundred ninety patients (mean age: 12 ± 2.8 years) fulfilled the inclusion criteria. Forty percent (n=76) of the fractures were treated by closed reduction. Premature growth arrest was seen in 6.8% (n=13) and diagnosed at a mean of 10 months post trauma. The logistic regression showed that the initial translation percentage (>30%) (p 25) (p increase the risk of growth arrest. After adjusting for concomitant ipsilateral ulnar injuries, a positive association between physeal complications and fracture manipulation was detected (76.9%, p=0.03). A non-significant trend between premature growth arrest and associated ulnar injury was observed (p=0.054). No association was identified for trauma velocity, fracture type, gender and age, and growth complications. A prevalence of 6.8% of growth arrest was found after a physeal fracture of the distal radius. Fractures presenting with an initial coronal translation > 30% and/or angulation > 25 from normal, as well as those treated by manipulation, have been shown to be at risk for a premature growth arrest of the distal radius. This study highlights the importance of a systematic follow-up after a physeal fracture of the distal radius especially for patients with a more displaced fracture who had a closed reduction performed. An optimal follow-up period should be over 10 months to optimize the detection of growth arrest and treat it promptly, thereby minimizing negative clinical consequences


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 623 - 630
1 Jun 2024
Perry DC Dritsaki M Achten J Appelbe D Knight R Widnall J Roland D Messahel S Costa ML Mason J

Aims. The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius. Methods. A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of ‘willingness-to-pay’ thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment. Results. The offer of a soft bandage significantly reduced cost per patient (saving £12.55 (95% confidence interval (CI) -£5.30 to £19.80)) while QALYs were similar (QALY difference between groups: 0.0013 (95% CI -0.0004 to 0.003)). The high probability (95%) that offering a bandage is a cost-effective option was consistent when examining the data in a range of sensitivity analyses. Conclusion. In addition to the known clinical equivalence, this study found that the offer of a bandage reduced cost compared with rigid immobilization among children with a torus fracture of the distal radius. While the cost saving was small for each patient, the high frequency of these injuries indicates a significant saving across the healthcare system. Cite this article: Bone Joint J 2024;106-B(6):623–630


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims. We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius. Patients and Methods. The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius. Results. Radiological parameters were found to correlate poorly with the patient reported outcomes (r = 0.00 to 0.47) and physical measures of function (r = 0.01 to 0.51) at all intervals. Conclusion. This study raises concerns about the use of radiological parameters to determine management, and to act as a surrogates for successful treatment, in patients with a fracture of the distal radius. Restoration of ‘normal’ radiographic parameters may not be necessary to achieve a satisfactory functional outcome for the patient. Cite this article: Bone Joint J 2017;99-B:376–82


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1656 - 1658
1 Dec 2006
Hatano H Morita T Kobayashi H Otsuka H

Despite extensive experience with prosthetic replacement for the reconstruction of limbs following juxta-articular resection of tumours, there are few reports of prosthetic replacement of the distal radius. We present two cases of massive bone defects of the distal radius in which alumina ceramic prosthetic replacements were used. We evaluated the patients more than ten years after the procedure. Both patients had degenerative changes to the wrist. This, however, was not associated with pain or decreased function, and both had returned to their previous occupation after surgery. When a patient has a massive defect of the distal radius, reconstruction using a ceramic prosthesis is a reasonable alternative to using autograft. This method of treatment results in little pain, a moderate range of movement and satisfactory function


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 113 - 113
1 Jul 2020
Badre A Perrin M Albakri K Suh N Lalone E
Full Access

Distal radius fractures are the most common upper extremity fracture. The incidence is significantly higher in elderly females with osteoporotic bone. When surgery is indicated, volar locking plates (VLPs) allow for rigid fixation particularly in comminuted fractures with poor bone quality. Although numerous studies have shown the importance of plate placement to avoid soft tissue complications associated with volar plate fixation, there has been little evidence on the anatomic fit of current VLPs. Moreover, the effect of gender differences in distal radius morphology on anatomic fitting of VLPs has not been studied. The aim of this study was to evaluate the gender difference in distal radius morphology and the accuracy of the fit of a current VLP to CT-based distal radius models. Segmented CT models of ten female (mean age, 89 ± 5 years), and ten male (mean age, 86 ± 4 years) cadaveric wrists were obtained. Micro-CT models of the DePuy-Synthes 4-hole extra-articular (EA) and 8-hole volar column (VC) distal radius VLPs were created. A 3D visualization software was used to simulate appropriate plate placement on to the distal radius models by a fellowship-trained hand surgeon. Volar cortical angles (VCA) of the medial, middle and lateral portion of the distal radius were measured and compared between genders. The accuracy of the fit of the two VLP designs were quantified using the percentage of the watershed line (WSL) overlapped by the plate (WSL overlap), the distance between the WSL and the most distal aspect of the posterior plate (prominence distance) and the percentage of contact between the plate and bone. There were statistically significant gender differences in medial, middle and lateral VCAs (p=.003 medial, p=.0001 middle, p=.002 lateral). VCA ranged from 28° to 36° in females and from 38° to 45° in males. The WSL overlap did not show statistically significant gender differences (male: 5.9%, female: 13.6%, p=.174). However, the difference in prominence distance between different genders approached statistical significance (male: 3.5mm, female: 2.6mm, p=.087). Contact mapping between the plate and bone did not demonstrate a perfect contact in any of our specimens. Thus, contact measurements were categorized into 0.1mm, 0.2mm, and 0.3mm threshold contacts. There were no statistically significant gender differences in any of the threshold categories (0.1mm: p=.84, 0.2mm: p=.97, 0.3mm: p=.99). Our results confirm that there are gender differences in distal radius morphology. Current plate designs incorporate a VCA of 25° which does not match the native VCA of the distal radius in males or females. Although the difference in prominence distance approached statistical significance, there were no statistically significant gender differences in the WSL overlap or the contact threshold values. This lack of statistical significance may be related to the small sample size. This study proposes novel methods of assessing the anatomic fit of current VLPs in a 3D CT-based model that may be used in future studies with a larger sample size. Moreover, this study demonstrated the importance of considering gender differences in distal radius morphology in the design of future generations of implants


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1271 - 1275
1 Oct 2008
Downing ND Karantana A

The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 963 - 969
1 Jul 2014
Mellstrand-Navarro C Pettersson HJ Tornqvist H Ponzer S

The aim of this study was to investigate the epidemiology of fractures of the distal radius in the Swedish population and to review the methods used to treat them between 2005 and 2010. The study population consisted of every patient in Sweden who was diagnosed with a fracture of the wrist between 1 January 2005 and 31 December 2010. There were 177 893 fractures of the distal radius. The incidence rate in the total population was 32 per 10 000 person-years. The mean age of the patients was 44 years (0 to 104). The proportion of fractures treated operatively increased from 16% in 2005 to 20% in 2010. The incidence rate for plate fixation in the adult population increased 3.61 fold. The incidence rate for external fixation decreased by 67%. The change was greatest in the 50 years to 74 years age group. In Sweden, there is an increasing tendency to operate on fractures of the distal radius. The previously reported increase in the use of plating is confirmed: it has increased more than threefold over a five-year period. Cite this article: Bone Joint J 2014;96-B:963–9


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study. With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies