The
To examine whether Natural Language Processing (NLP) using a state-of-the-art clinically based Large Language Model (LLM) could predict patient selection for Total Hip Arthroplasty (THA), across a range of routinely available clinical text sources. Data pre-processing and analyses were conducted according to the Ai to Revolutionise the patient Care pathway in Hip and Knee arthroplasty (ARCHERY) project protocol (. https://www.researchprotocols.org/2022/5/e37092/. ). Three types of deidentified Scottish regional clinical free text data were assessed: Referral letters, radiology reports and clinic letters. NLP algorithms were based on the GatorTron model, a Bidirectional Encoder Representations from Transformers (BERT) based LLM trained on 82 billion words of de-identified clinical text. Three specific inference tasks were performed: assessment of the base GatorTron model, assessment after model-fine tuning, and external validation. There were 3911, 1621 and 1503 patient text documents included from the sources of referral letters, radiology reports and clinic letters respectively. All letter sources displayed significant class imbalance, with only 15.8%, 24.9%, and 5.9% of patients linked to the respective text source
Introduction. Recent literature has sought to quantify pre-operative work associated with total joint arthroplasty. These studies have utilized surveys or self-reported time logs to estimate the Pre-op Optimization Work (POW) completed by the surgical team. The purpose of this study was to objectively quantify POW associated with total hip arthroplasty (THA) using electronic medical record (EMR) activity audit logs. Methods. Retrospective analysis of EMR activity for 4 arthroplasty surgeons and their clinical staff was collected for 100 consecutive THA cases (25 per surgeon). Clinical informatics data was generated using EMR activity audit logs for pre-THA activity. Every action and mouse-click within a patient's chart was recorded for each team member. The time between mouse-clicks was calculated and summed for each user. Times exceeding five minutes without activity were assumed to reflect inactivity and excluded. Descriptive statistics were used to estimate the POW associated with THA preparation. Results. The mean number of days for pre-THA time period was70.7 (SD43.9; range: 8–175days). During this period, the mean time spent in each patient's chart was 75.5 minutes (SD50.75) minutes. Surgeon's POW in the medical record accounted for 7.3(SD6.7) of these minutes. Much of the work was conducted by nurses (47.0 minutes, SD43.4), physician extenders (10.8 minutes, SD 13.1), and qualified office staff/technicians (10.4 minutes, SD14.9). The majority of work captured in the EMR activity log was associated with medication review, patient optimization,
This study compares the re-revision rate and mortality following septic and aseptic revision hip arthroplasty (rTHA) in registry data, and compares the outcomes to previously reported data. This is an observational cohort study using data from the German Arthroplasty Registry (EPRD). A total of 17,842 rTHAs were included, and the rates and cumulative incidence of hip re-revision and mortality following septic and aseptic rTHA were analyzed with seven-year follow-up. The Kaplan-Meier estimates were used to determine the re-revision rate and cumulative probability of mortality following rTHA.Aims
Methods
Introduction. Total hip arthroplasty (THA) candidates have received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid administration
Delirium is associated with adverse outcomes following hip fracture, but the prevalence and significance of delirium for the prognosis and ongoing rehabilitation needs of patients admitted from home is less well studied. Here, we analyzed relationships between delirium in patients admitted from home with 1) mortality; 2) total length of hospital stay; 3) need for post-acute inpatient rehabilitation; and 4) hospital readmission within 180 days. This observational study used routine clinical data in a consecutive sample of hip fracture patients aged ≥ 50 years admitted to a single large trauma centre during the COVID-19 pandemic between 1 March 2020 and 30 November 2021. Delirium was prospectively assessed as part of routine care by the 4 A’s Test (4AT), with most assessments performed in the emergency department. Associations were determined using logistic regression adjusted for age, sex, Scottish Index of Multiple Deprivation quintile, COVID-19 infection within 30 days, and American Society of Anesthesiologists grade.Aims
Methods
The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate. This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database.Aims
Methods
The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection. We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022.Aims
Methods
The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture. This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.Aims
Methods
This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality. This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality.Aims
Methods
In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).Aims
Methods
Introduction. Deaths due to overdose involving opioids have nearly quadrupled in USA in the last 20 years. Several published studies have shown that preoperative opioid use independently predicts perioperative complications in total joint arthroplasty. Our objectives were to (1) assess preoperative opioid consumption in patients undergoing total hip arthroplasty (THA) and (2) to determine how preoperative opioid use affects patient oriented outcomes (POO's) and hip scores before and after THA. Methods. 54 primary THA by a single surgeon were reviewed. A new patient questionnaire was administered to document preoperative opioid consumption (type, dosage and length of use); preoperatively and postoperatively POO's measurements [visual analog scale (VAS), QWB-7, SF-36, and WOMAC] and hip scores were recorded. Patients were stratified into two groups: (1) Opioid Users and (2) Non-Opioid Users. Oral morphine equivalents (OME) were calculated for opioid using patients using standard methodology. Results. 22.2% of the patients were using opioids prior to THA. Among these, 16.6% had tried more than 1 drug. Dosage was self-reported in 33.3% and length of usage only in 8.3%. Mean OME was 13.3mg (range: 6mg–32mg) among users. After adjusting for covariates (gender), opioid users reported worse significant outcomes before surgery for the SF-36 general health (69 vs 80.7; p=0.02), SF-36 role emotional (75.7 vs 99.1; p=0.002), and SF-36 mental health (64 vs 79.7; p=0.005). After surgery even though significant improvements were seen in both groups, opioid users reported significantly worse WOMAC pain scores (1.4 vs 0.3; p=0.03) than non-opioid users. Conclusions. Almost a quarter of the patients in our community undergoing THA, use opioid medications prior to surgery. Opioid users came to surgery with more pain and less function and had worse outcomes.
There have been considerable recent advances in the understanding and management of femoroacetabular impingement and associated labral and chondral pathology. We have developed a classification system for acetabular chondral lesions. In our system, we use the six acetabular zones previously described by Ilizaliturri et al. The cartilage is then graded on a scale of 0 to 4 as follows: grade 0, normal articular cartilage lesions; grade 1, softening or wave sign; grade 2, cleavage lesion; grade 3, delamination; and grade 4, exposed bone. The site of the lesion is further classed as A, B or C based on whether the lesion is less than one-third of the distance from the acetabular rim to the cotyloid fossa, one-third to two-thirds of the same distance and greater than two-thirds of the distance, respectively. In order to validate the classification system, six surgeons graded ten video recordings of hip arthroscopy. Our findings showed a high intra-observer reliability of the classification system with an intraclass correlation coefficient of 0.81 and a high interobserver reliability with an intraclass correlation coefficient of 0.88. We have developed a simple reproducible classification system for lesions of the acetabular cartilage, which it is hoped will allow standardised
Summary. Narcotic administration within the inpatient setting is highly variable any may benefit from the implementation of standardized multi-modal pain management protocols. Introduction. Total joint arthroplasty (TJA) candidates have historically received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid prescribing
The Patient-Reported Outcomes Measurement Information System (PROMIS) has demonstrated faster administration, lower burden of data capture and reduced floor and ceiling effects compared to traditional Patient Reported Outcomes Measurements (PROMs). We investigated the suitability of PROMIS Mobility score in assessing physical function in the sequelae of childhood hip disease. In all, 266 adolscents (aged ≥ 12 years) and adults were identified with a prior diagnosis of childhood hip disease (either Perthes’ disease (n = 232 (87.2%)) or Slipped Capital Femoral Epiphysis (n = 34 (12.8%)) with a mean age of 27.73 years (SD 12.24). Participants completed the PROMIS Mobility Computer Adaptive Test, the Non-Arthritic Hip Score (NAHS), EuroQol five-dimension five-level questionnaire, and the Numeric Pain Rating Scale. We investigated the correlation between the PROMIS Mobility and other tools to assess use in this population and any clustering of outcome scores.Aims
Methods
The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs).Aims
Methods
This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.Aims
Methods
Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
The prevalence of combined abnormalities of femoral torsion (FT) and tibial torsion (TT) is unknown in patients with femoroacetabular impingement (FAI) and hip dysplasia. This study aimed to determine the prevalence of combined abnormalities of FT and TT, and which subgroups are associated with combined abnormalities of FT and TT. We retrospectively evaluated symptomatic patients with FAI or hip dysplasia with CT scans performed between September 2011 and September 2016. A total of 261 hips (174 patients) had a measurement of FT and TT. Their mean age was 31 years (SD 9), and 63% were female (165 hips). Patients were compared to an asymptomatic control group (48 hips, 27 patients) who had CT scans including femur and tibia available for analysis, which had been acquired for nonorthopaedic reasons. Comparisons were conducted using analysis of variance with Bonferroni correction.Aims
Methods
A proximal femur fracture (PFF) is a common orthopaedic presentation, with an incidence of over 25,000 cases reported in the Australian and New Zealand Hip Fracture Registry (ANZHFR) in 2018. Hip fractures are known to have high mortality. The purpose of this study was to determine the utility of the Clinical Frailty Scale (CFS) in predicting 30-day and one-year mortality after a PFF in older patients. A retrospective review of all fragility hip fractures who met the inclusion/exclusion criteria of the ANZHFR between 2017 and 2018 was undertaken at a single large volume tertiary hospital. There were 509 patients included in the study with one-year follow-up obtained in 502 cases. The CFS was applied retrospectively to patients according to their documented pre-morbid function and patients were stratified into five groups according to their frailty score. The groups were compared using Aims
Methods