Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 38 - 38
1 May 2017
Ertem F Havıtçıoğlu Ç Erduran M Havıtçıoğlu H
Full Access

Background. The advantages of treatment by open reduction and internal fixation for intertrochanteric fractures of the proximal femur have been well known for several decades. Failure of fixation can result in revision surgery, prolonged inpatient stay and has major socio-economic consequences. There are many new devices on the market to help deal with this problem. Expandable hip screw (EHS) is one such device, which is an expanding bolt that may offer superior fixation in osteoporotic bone compared to the standard dynamic hip screw (DHS) type device. Methods. Static axial compression tests with elastic deformation of the specimens were performed with a crosshead speed of 10 mm/min to determine stiffness of testing was performed with 3 cycles from 0 N to 250 N, 3 cycles from 0 N to 500 N, 3 cycles from 0 N to 750 N and 3 cycles from 0 N to 1000 N with a holding time of 10 s per test cycle. Displacement control was apply the pullout strength with a velocity of 1mm/sec. The ability to resist rotation about the axis of a lag screw is of critical importance particularly when the fracture line is perpendicular, or nearly perpendicular, to the femoral neck. Implants were subjected to a rotation of 1 degree/sec and peak torque values were recorded. Results. The mean axial cyclic loading DHS showed higher stiffness value than EHS. The mean stiffness achieved at pullout test in the EHS and DHS groups were 587.8N/mm and, 334.1N/mm respectively (p<0.05). The peak torque for the EHS device was significantly greater than the torque for the DHS with torque values of 4.56 Nm/degree and 2.97 Nm/degree, respectively (p<0.05). Conclusions. The EHS device demonstrated superior resistance to pullout and torsion greater loads compared to the DHS in an unstable fracture model. However, axial cyclic loading demonstrate lower strength, by optimising the size of device will perform. Level of Evidence. Level 5


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 79 - 79
1 Apr 2018
van Duren B Wescott R Sugand K Carrington R Hart A
Full Access

Background. Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software. Methods. The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students. Results. The median absolute inaccuracy of FluoroSim with 270 measurements was 3.35mm (IQR = [1.15mm, 6.53mm]). The absolute inaccuracy showed a graded increase the further away the tip of the guide-wire was from the centre of calibration; MGAD ≤10mm, median absolute inaccuracy = 1.53mm; MGAD 10mm<x≤20mm, median absolute inaccuracy = 4.97mm; MGAD >20mm, median absolute inaccuracy = 7.23mm. Comparison between all three groups reached significance (p < 0.001). In a simulation scenario with medical students, FluoroSim had a significantly greater median absolute inaccuracy of 4.79mm compared to the testing scenario (p < 0.001). Conclusion. FluoroSim is a safe and inexpensive digital imaging adjunct to workshop bones simulation. To our knowledge this technology has not been explored in the context of DHS simulation, and has the potential to be extended to other orthopaedic procedures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 80 - 80
1 Apr 2018
Sugand K van Duren B Wescott R Carrington R Hart A
Full Access

Background. Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. Methods. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt. Results. A significant construct effect was seen for TAD and COR between novice and other users (p < 0.05). The intermediate and experienced users were not significantly different for these metrics. For all other metrics, experienced users had the highest score, contrary to expectation. Conclusion. FluoroSim was able to separate novice users from other cohorts for the two clinically significant outcome metrics. We can therefore partially reject the null hypothesis as construct validity was present for TAD and COR. We have demonstrated that FluoroSim has the potential to be a useful adjunct when learning the psychomotor skills needed for the DHS procedure away from theatre


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 81 - 81
1 Apr 2018
Sugand K Wescott R van Duren B Carrington R Hart A
Full Access

Background. Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim. Methods. Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR). Results. No significant difference was present for any metric between the groups at baseline; randomisation had produced heterogeneous groups minimising selection bias. Intragroup training effect (comparison of initial and last attempt) was significant for all metrics in the training group (p < 0.05) but for no metrics in the control group. The intergroup training effect (comparison of training group attempt ten to control group attempt ten) was present for procedural time, number of radiographs and number of guide-wire retries (p < 0.05). Significance was not reached for TAD and COR. Conclusion. FluoroSim shows skill acquisition with repeat exposure, so the null hypothesis can be rejected. This study has demonstrated the merits of FluoroSim as a training adjunct for psychomotor skill development in a DHS setting


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 45 - 45
1 Aug 2013
Chambers M Diffin C Campton L Roberts J Kelly M
Full Access

A tip-apex distance (TAD) greater than 25 mm is a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated with a dynamic hip screw (DHS). We aim to show you a simple and reliable way to check this. By calculating the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and lateral views the TAD is found. X-rays often have magnification errors and therefore measuring tools in digital x-ray systems will be inaccurate. The original method of calculating the TAD uses the known diameter of the screw to avoid magnification errors. We found that due to the no-cylindrical shape of the screw shaft there is potential of an inaccurate measurement. By using the distance across the highest points of the thread a more accurate TAD can be calculated. The distance across the highest points of the threads in all three of the most commonly used DHSs in the UK is 13 mm. If the measured distance from the tip of the screw to the apex of the femoral head in both the anteroposterior and lateral views is less than the measured distance across of the treaded diameter of the screw then the surgeon knows the TAD is less than 26 mm. This method can be used intraoperatively to check the TAD by looking at the fluoroscopy images in these two views


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 74 - 74
1 May 2012
Abbas G Thakar C McMaster J
Full Access

Introduction. The use of the dynamic hip screw is common practice for the fixation of intertrochanteric fractures of the femur. The success of this procedure requires accurate guide wire placement. This can prove difficult at times and can result in repeated attempts leading to longer operating time, multiple tracks and more importantly greater radiation exposure to both patient and operating staff. We hypothesised that rather than using the standard anterior-posterior projected image (Figure 1) of a proximal femur, rotating the intensifier image (Figure 2) so that the guide wire appears to pass vertically makes it easier to visualise the projected direction of the guide wire. Methods. Fifty Specialist Registrars, thirty participating in the London hip meeting 2009, ten from Oxford and ten from Northern deanery orthopaedic rotations were involved in the study. They were presented with standard AP and rotated images of the femoral neck on paper using 135 degree template to replicate the DHS guide. The participants were asked to mark the entry point on the intertrochanteric area of femur on the image where they would have placed the guide wire. They did this on both standard AP and rotated images aiming for the centre of the head of the femur. Fig. 1 Standard AP image Fig. 2 Rotated image. Results. Thirty-seven Specialist Registrars (74%) were able to accurately mark their entry point on rotated images on their first attempt as compared to eighteen trainees (36%) managing to place it correctly first time on the standard image. Thirteen trainees (26%) were able to mark their entry point correctly on both standard AP and rotated images with equal accuracy. Conclusion. Coren et al. 1 argue that human vision can more easily judge horizontal and vertical lines rather than oblique lines. Thus, rather than use the standard anterior-posterior projected image of the hip, we should routinely rotate the intensifier image so that the guide wire appears to be passing in a vertical direction. By rotating the image (Figure 2) in this way it becomes significantly easier to visualise the projected direction of the guide wire and in doing so ensure its accurate final placement thereby minimising possible complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2021
Kumar G Debuka E
Full Access

Increasing incidence of osteoporosis, obesity and an aging population have led to an increase in low energy hip fractures in the elderly. Perceived lower blood loss and lower surgical time, media coverage of minimal invasive surgery and patient expectations unsurprisingly have led to a trend towards intramedullary devices for fixation of extracapsular hip fractures. This is contrary to the Cochrane review of random controlled trials of intramedullary vs extramedullary implants which continues recommends the use of a sliding hip screw (SHS) over other devices. Furthermore, despite published literature of minimally invasive surgery (MIS) of SHS citing benefits such as reduced soft tissue trauma, smaller scar, faster recovery, reduced blood loss, reduced analgesia needs; the uptake of these approaches has been poor. We describe a novel technique one which remains minimally invasive, that not only has a simple learning curve but easily reproducible results. All patients who underwent MIS SHS fixation of extracapsular fractures were included in this study. Technique is shown in Figure 1. We collated data on all intertrochanteric hip fractures that were treated by a single surgeon series during period Jan 2014 to July 2015. Data was collected from electronic patient records and radiographs from Picture Archiving and Communication System (PACS). Surgical time, fluoroscopy time, blood loss, surgical incision length, post-operative transfusion, Tip Apex Distance (TAD) were analyzed. There were 10 patients in this study. All fractures were Orthopaedic Trauma Association (OTA) type A1 or A2. Median surgical time was 36 minutes (25–54). Mean fluoroscopy time was similar to standard incision sliding hip screw fixation. Blood loss estimation with MIS SHS can be undertaken safely and expeditiously for extracapsular hip fractures.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 89 - 89
17 Apr 2023
Alzahrani S Aljuaid M Bazaid Z Shurbaji S
Full Access

A Morel-Lavallee lesion (MLL) is a benign cystic lesion that occurs due to injury to the soft-tissue envelope's perforating vascular and lymphatic systems, resulting in a distinctive hemolymphatic fluid accumulation between the tissue layers. The MLL has the potential to make a significant impact on the treatment of orthopaedic injuries.

A 79-year-old male patient community ambulatory with assisting aid (cane) known case of Diabetes mellitus, hypertension, bronchial asthma and ischemic heart disease. He was brought to the Emergency, complaining of right hip discomfort and burning sensation for the last 5 days with no history of recent trauma at all. Patient had history of right trochanteric femur fracture 3 years ago, treated with DHS in a privet service. Clinical and Radiological assessment showed that the patient mostly has acute MLL due to lag screw cut out. We offered the patient the surgical intervention, but he refused despite explaining the risks of complications if not treated and preferred to receive the conservative treatment. Compression therapy management explained to him including biker's shorts (instructed to be worn full-time a day) and regular follow up in clinic. Symptom's improvement was reported by the patient in the subsequent visits.

In the polytrauma patient, a delayed diagnosis of these lesions is conceivable due to the presence of more visible injuries. It's located over the greater trochanter more commonly, but sometimes in other areas such as the lower lumbar region, the thigh, or the calf. Incorrect or delayed diagnosis and care can have unfavorable outcomes such as infection, pseudocyst development, and cosmetologically deformity. Magnetic resonance imaging (MRI) and ultrasound will aid in MLL diagnosis. However, the effectiveness of MLL therapy remains debatable.

We strongly believe that the MLL caused due to tangential shear forces applied to the soft tissue leads to accumulation of the blood and/or lymph between the subcutaneous and overlying fascia and it often misdiagnosed due to other distracting injuries. Nontheless, in our case we reported MLL occur due to internal pressure on the fascia caused by cut out of DHS lag screw.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 92 - 92
17 Apr 2023
Raina D Mrkonjic F Tägil M Lidgren L
Full Access

A number of techniques have been developed to improve the immediate mechanical anchorage of implants for enhancing implant longevity. This issue becomes even more relevant in patients with osteoporosis who have fragile bone. We have previously shown that a dynamic hip screw (DHS) can be augmented with a calcium sulphate/hydroxyapatite (CaS/HA) based injectable biomaterial to increase the immediate mechanical anchorage of the DHS system to saw bones with a 400% increase in peak extraction force compared to un-augmented DHS. The results were also at par with bone cement (PMMA). The aim of this study was to investigate the effect of CaS/HA augmentation on the integration of a different fracture fixation device (gamma nail lag-screw) with osteoporotic saw bones. Osteoporotic saw bones (bone volume fraction = 15%) were instrumented with a gamma nail without augmentation (n=8) or augmented (n=8) with a CaS/HA biomaterial (Cerament BVF, Bonesupport AB, Sweden) using a newly developed augmentation method described earlier. The lag-screws from both groups were then pulled out at a displacement rate of 0.5 mm/s until failure. Peak extraction force was recorded for each specimen along with photographs of the screws post-extraction. A non-parametric t-test was used to compare the two groups. CaS/HA augmentation of the lag-screw led to a 650% increase in the peak extraction force compared with the controls (p<0.01). Photographs of the augmented samples shows failure of the saw-bones further away from the implant-bone interface indicating a protective effect of the CaS/HA material. We present a novel method to enhance the immediate mechanical anchorage of a lag-screw to osteoporotic bone and it is also envisaged that CaS/HA augmentation combined with systemic bisphosphonate treatment can lead to new bone formation and aid in the reduction of implant failures and re-operations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 152 - 152
1 Nov 2021
Selim A Seoudi N Algeady I Barakat AS
Full Access

Introduction and Objective. Hip fractures represent one of the most challenging injuries in orthopaedic practice due to the associated morbidity, mortality and the financial burden they impose on the health care systems. By many still considered as the gold standard in the management of intertrochanteric fractures, the Dynamic Hip Screw utilizes controlled collapse during weight bearing to stabilize the fracture. Despite being a highly successful device, mechanical failure rate is not uncommon. The most accepted intraoperative indicator for lag screw failure is the tip apex distance (TAD), yet lateral femoral wall thickness (LWT) is another evolving parameter for detecting the potential for lateral wall fracture with subsequent medialization and implant failure. The aim of this study is to determine the mean and cut off levels for LWT that warrant lateral wall fracture and the implications of that on implant failure, revision rates and implant choice. Materials and Methods. This prospective cohort study included 42 patients with a mean age of 70.43y with intertrochanteric hip fractures treated with DHS fixation by the same consultant surgeon from April 2019 to December 2019. The study sample was calculated based on a confidence level of 90% and margin of error of 5%. Fracture types included in the study are 31A1 and 31A2 based on the AO/OTA classification system. LWT was assessed in all patients preoperatively using Surgimap (Nemaris, NY, USA) software. Patients were divided into two groups according to the post-operative integrity of the lateral femoral wall, where group (A) sustained a lateral femoral wall fracture intraoperatively or within 12 months after the index procedure, while in group (B) the lateral femoral wall remained intact. All patients were regularly followed up radiologically and clinically per the Harris Hip Score (HHS) for a period of 12 months. Results. At 12 months five patients (12%) suffered a postoperative lateral wall fracture, while in 37 patients (88%) the lateral femoral wall remained intact. The mean preoperative LWT of patients with a postoperative lateral wall fracture was 18.04 mm (SD ± 1.58) compared to 26.22mm (SD ± 5.93) in the group without a lateral wall fracture. All patients with post-operative lateral femoral wall fracture belong to 31A2 group, while 78.4% of the patients that did not develop post-operative lateral femoral wall fracture belong to 31A1 group. Eighty percent of patients in group (A) experienced shortening, collapse, shaft medialization and varus deformity. The mean Harris hip score of group (A) was 39.60 at 3 months and 65.67 at 6 months postoperatively, while that of group (B) was 80.75 and 90.65 at 3 and 6 months respectively, denoting a statistically significant difference (P<0.001). Treatment failure meriting a revision surgery was 40 % in group (A) and 8% in group (B) denoting a statistically significant difference (p<0.001). The cut-off point of LWT below which there is a high chance of post-operative lateral wall fracture when fixed with DHS is 19.6mm. This was shown on the receiver operating curve (ROC) by plotting the sensitivity against the 100 % specificity with a set 95% confidence interval 0.721 – 0.954. When lateral wall thickness was at 19.6 mm, the sensitivity was 100% and specificity was 81.8%. The area under the curve (AUC) was 0.838, which was statistically significant (P = 0.015). Conclusions. Preoperative measurement of LWT in elderly patients with intertrochanteric hip fractures is decisive. The cut off point for postoperative lateral wall fracture according to our study is 19.6 mm; hence, intramedullary fixation has to be considered in this situation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 46 - 46
1 May 2017
Page P Lee C Rogers B
Full Access

Background. Fractures of the femoral neck occurring outside the capsule of the hip joint are assumed to have an intact blood supply and hence their conventional management is by fixation rather than arthroplasty. The dynamic hip screw and its variants have been used over many years to fix such fractures but have inherent vulnerabilities; they require an intact lateral femoral cortex, confer a relatively long moment arm to the redistribution of body weight and may cause a stress riser due to the plate with which they are fixed to the femur. Intramedullary devices for fixation of proximal femoral fractures have a shorter moment arm, can be distally locked with reduced perforation of the femoral cortex and are believed to be inherently more stable. For these reasons, a number of surgeons believe them to be superior to the DHS for all extracapsular fractures and their use is now widespread. In this study, we present the usage trends of both devices in extracapsular fractures over the last five years and set these results in the context of patient demographics. Methods. Our departmental electronic patient management system was used to identify all patients undergoing surgery coded as either DHS or its variants or intramedullary fixation of hip fracture. The patients’ age, sex and American Society of Anaesthesiologists grading were recorded. Comparison between groups was made using appropriate tests in SPSS. Results. Our unit has seen a steady move towards the use of intramedullary fixation of extracapsular fractures over five years, from 28.2% to 45.2% of operations, without a change in demographics of the population or a change in surgical outcomes at the most basic level. Conclusion. The move towards intramedullary fixation without evidence of improved outcomes, given the significantly higher cost, requires urgent research. Level of Evidence. IV


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 77 - 77
1 Apr 2017
Rashid M Aziz S Heydar S Fleming S Datta A
Full Access

Background. Radiation exposure remains a significant occupational hazard for Orthopaedic surgeons. There are no references values for trauma procedures performed with Image Intensifier (II). We aimed to determine and compare reference values for patient radiation exposure for common trauma operations, and to analyse the effect of surgeon grade on II usage. Methods. Data collected prospectively from 849 cases between 01/05/2013 and 01/10/2014 were analysed. Statistical analysis was performed to calculate reference values for dose area product (DAP), screening time (ST), and number of II images taken for common trauma procedures where n>9 (n=808). Results. Dynamic hip screw (DHS) fixation required significantly less radiation than proximal femoral nail (PFN) for intertrochanteric hip fractures for median DAP (668mG/cm2 vs 1040mG/cm2, p<0.001), ST (00:36 vs 00:48, p<0.001), and number of II images (65 vs 110, p<0.001). Radiation exposure was statistically significantly less when Consultant Orthopaedic surgeons were first surgeon compared to Staff grade doctors and Orthopaedic trainees for DAP (90.55mGy/cm2 vs 175.5mGy/cm2 vs 366.5mGy/cm2), screening time (00:26 vs 00:32 vs 00:36), and number of II images (49 vs 59 vs 66). Conclusions. We reported reference values for common trauma operations that are essential to enable monitoring of patient radiation exposure. PFN required greater radiation exposure than DHS for intertrochanteric hip fracture. Increased surgical experience lead to lower radiation exposure in trauma operations, which could be developed to assess trauma competence within surgical training. Level of evidence. III


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 21 - 21
1 May 2017
Sargazi N Adamson E Cheung G
Full Access

Background Hip fractures are one of the leading causes of hospital admissions. Surgical treatment is often associated with significant blood loss, requiring post-operative erythrocyte transfusion. Aim To assess post-operative erythrocyte transfusion rates for hip fractures and evaluate the effect of tranexamic acid (TXA). Method. All patients undergoing surgical repair of a hip fracture at RLBUHT between 1st April 2013 – 30th April 2014 were selected. Data regarding transfusion status and peri-operative TXA use was collected from electronic databases and case notes. Results. 450 patients were admitted with a hip fracture, of whom 441 underwent surgery. Modalities of hip fixation included total hip replacement (THR, n=39), hemiarthroplasty (n=145), dynamic hip screw (DHS, n=116), cannulated hip screw (CHS, n=17) and long (n=71) and short (n=53) intramedullary hip screw (IMHS). 44.2% received a post-operative erythrocyte transfusion, with an average of 2.5 units per patient (range 1–9 units). With all study subjects included, the average transfusion rates for THR, hemiarthroplasty, DHS, CHS, long IMHS and short IMHS were 0.44 units, 0.78 units, 0.97 units, 0.47 units, 1.55 units and 1.19 units respectively. Data regarding intra-operative TXA administration was available for 318 (72.1%) patients, sixty-one of whom received TXA. 27.9% given TXA required a post-operative transfusion (range 0–6 units), compared to 35.4% of patient with no intra-operative TXA (range 0–11 units), p=0.142. Conclusion. 44.2% of patients required an erythrocyte transfusion, with an average of 2.5 units per patient of those transfused. This is higher than rates quoted by other studies including Shokoohi et al who had a transfusion rate of 32.6%. Adherence to local transfusion protocols must be reviewed. There is a tendency for TXA to reduce post-operative transfusion requirements, however in this study, this did not reach statistical significance (p=0.142). A larger, randomised controlled trial is required to assess the role TXA in hip fracture surgery


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 4 - 4
1 Jan 2017
Stoffel K Zderic I Sommer C Eberli U Müller D Oswald M Gueorguiev B
Full Access

Three Cannulated Screws (3CS), Dynamic Hip Screw (DHS) with antirotation screw (DHS–Screw) or with a Blade (DHS–Blade) are the gold standards for fixation of unstable femoral neck fractures. Compared to 3CS, both DHS systems require larger skin incision with more extensive soft tissue dissection while providing the benefit of superior stability. The newly designed Femoral Neck System (FNS) for dynamic fixation combines the advantages of angular stability with a less invasive surgical technique. The aim of this study is to evaluate the biomechanical performance of FNS in comparison to established methods for fixation of the femoral neck in a human cadaveric model. Twenty pairs of fresh–frozen human cadaveric femora were instrumented with either DHS–Screw, DHS–Blade, 3CS or FNS. A reduced unstable femoral neck fracture 70° Pauwels III, AO/OTA31–B2.3 was simulated with 30° distal and 15° posterior wedges. Cyclic axial loading was applied in 16° adduction, starting at 500N and with progressive peak force increase of 0.1N/cycle until construct failure. Relative interfragmentary movements were evaluated with motion tracking. Highest axial stiffness was observed for FNS (748.9 ± 66.8 N/mm), followed by DHS–Screw (688.8 ± 44.2 N/mm), DHS–Blade (629.1 ± 31.4 N/mm) and 3CS (584.1 ± 47.2 N/mm) with no statistical significances between the implant constructs. Cycles until 15 mm leg shortening were comparable for DHS–Screw (20542 ± 2488), DHS–Blade (19161 ± 1264) and FNS (17372 ± 947), and significantly higher than 3CS (7293 ± 850), p<0.001. Similarly, cycles until 15 mm femoral neck shortening were comparable between DHS–Screw (20846 ± 2446), DHS–Blade (18974 ± 1344) and FNS (18171 ± 818), and significantly higher than 3CS (8039 ± 838), p<0.001. From a biomechanical point of view, the Femoral Neck System is a valid alternative to treat unstable femoral neck fractures, representing the advantages of a minimal invasive angle–stable implant for dynamic fixation with comparable stability to the two DHS systems with blade or screw, and superior to Three Cannulated Screws


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 31 - 31
1 Jun 2012
Hussain S Cairns D Mann C Horey L Patil S Meek R
Full Access

The objective was to compare vastus lateralis muscle splitting verses muscle sparing surgical approach to proximal femur for fixation of intertrochanteric fracture. Of the 16 patients in this prospective randomised double blind study 8 were randomised to vastus lateralis muscle splitting and rest to muscle sparing group. Main outcome measurement was assessment of status of vastus lateralis muscle at 2 and 6 weeks using nerve conduction study. Preoperative demographics were identical for both the groups. There was no statistically significant difference between the groups with regards to velocity, latency, and amplitude. The postoperative haemoglobin drop, heamatocrit, position of the dynamic hip screw and mobility status were identical. Both clinical and neurophysiological outcome suggest that damage done to vastus lateralis either by splitting or elevating appears to be identical


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 23 - 23
1 Aug 2013
Mahmood F Davison M
Full Access

Digital radiographs are routinely used for preoperative planning, both in trauma and elective patients; particularly in preoperative templating for total hip replacement. Traditional wisdom holds that radiographs are oversized, though the degree to which this occurs is unclear. Although digital templating systems offer the use of calibration markers, this option is not always availed. We aimed to ascertain the typical magnification in departmental xrays of the hip, both to determine the typical degree of magnification as well as ascertain its consistency. All patients undergoing dynamic hip screw fixation (DHS) in our unit over the past 12 months were identified. Using the PACS system, subsequent xrays of the patient with the implant in situ were identified; both anteroposterior abdominal and pelvic films were used. The width of a standard DHS screw (12.5 mm) was compared with the width measured on the xrays to determine a magnification factor. 164 patients were identified, of these 39 had undergone DHS fixation with subsequent xrays. 3 films were focused on the abdomen but provided good coverage of the hip also. 2 xrays were excluded – both due to limited quality. The average magnification was 26.4% (range 15.5%–42%). There was limited consistency between images. Radiographs are a core investigation in the assessment of the orthopaedic patient. The advent of picture archiving and communications systems (PACS) has allowed the enterprising surgeon to pre-emptively plan their surgical technique and implant use. However, the utility of non-calibrated images in planning implant size is limited by variation in magnification. Surgeons should be cautious in using such images to guide their implant usage


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 27 - 27
1 Aug 2013
Hansom J McGraw I Periasamy K Gregori A
Full Access

Whilst the SIGN Guidelines state that the use of prophylactic antibiotics in surgery unequivocally reduces major morbidity, reduces hospital costs and is likely to decrease overall consumption of antibiotics they state the chosen antibiotics must reflect local, disease-specific information about the common pathogens and their antimicrobial susceptibility. Growing healthcare concern regarding the rates of Clostridium Difficile (C. Diff) within the hospital setting have led to rationalised and better streamlined prescribing practice within the NHS. In NHS Lanarkshire this led to revised guidelines for prophylactic antibiotic use in Orthopaedics in 2010. Routine use of 3. rd. generation Cephalosporin has been replaced by Flucloxacillin 1g and Gentamicin 1mg/kg. Anecdotally the surgeons within our department were concerned that they were recognising more post-operative renal impairment than before 2010. Our study took 902 consecutive cases treated surgically with either Total Hip Replacement, Total Knee Replacement, Dynamic Hip Screw for fracture and Hemiarthroplasty for fracture since the introduction of the new antibiotic policy. We compared this with a similar number of cases treated with the same operations pre-2010. We looked at the pre admission Urea & Electrolystes compared with immediate post-operative results and applied the definition of Acute Kidney Injury (AKI) as defined by the Acute Kidney Injury Network. A. A rapid time course (less than 48 hours) and B. Reduction of kidney function either as an absolute increase in serum creatinine of ≥26.4μmol/l (≥0.3 mg/dl) or a percentage increase in serum creatinine of ≥50%. Based on this definition we found an increased rate of AKI of 13.7% after the introduction of the use of Gentamicin from 9.8% before its routine use. We wish to highlight that the routine widespread use of Gentamicin may be increasing the rate of acute renal dysfunction seen in Orthopaedic patients undergoing major surgery


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 53 - 53
1 Aug 2013
Davison M
Full Access

It is widely accepted that a tip apex distance of greater than 25mm is associated with dynamic hip screw (DHS) failure and cut-out. The aim was to devise an accurate and easy method for calculation of DHS tip apex distance (TAD) from intraoperative imaging using the tools available on Kodac Picture Archiving and Communications System. This method was applied to all patients treated with a DHS for intertrochanteric hip fracture during a six month period. Any subsequent radiographs were assessed for evidence of failure within 18 months. The TAD was calculated using a modification of a previously described method using a similar imaging system (Johnston et al, Injury 2008) which has been shown to be accurate and reproducible. Scaling was based on the 12.5mm thread diameter of all Synthes (Switzerland) DHS screws. 60 patients underwent a DHS during the study. Nine patients were excluded who had an additional method of fixation or an intracapsular fracture. Four patients had insufficient xrays for analysis. Data was gathered for 47 patients and showed a mean TAD of 17mm (range 8.2–30.6mm). Three patients had a TAD greater than 25mm. 22 patients had a post-operative xray within 18 months. There were two cut-outs identified and both were from patients with a TAD of greater than 25mm (25.7 and 30.6mm). No incidences of implant failure or complications were identified for patients with acceptable TADs. 93.6% of screws were therefore inserted satisfactorily. Two out of the three patients with a TAD greater than 25mm had xray evidence of screw cut-out. This study supports previous evidence that a DHS lag screw should be positioned with a TAD within 25mm and a distance greater than this is associated with screw cut-out. TAD can be easily calculated using intraoperative xrays and scaled using the screw itself


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 89 - 89
1 May 2012
Chan K Koh H Zubairy A
Full Access

INTRODUCTION. Warfarin remains the treatment of choice for the majority of patients with venous thromboembolism, atrial fibrillation and valvular heart disease or valve replacement unless contraindicated. Poor management of patients on warfarin often leads to delay in surgery, life threatening bleeding during or after operation and unnecessary delay in discharge from hospitals in United Kingdom. METHODS. We carried out a prospective study on patients who were on warfarin and underwent elective and emergency orthopaedic procedures during period of study- August 2007 to April 2008. All patients included in the study were identified from admission notes during period of study. All data regarding indications for warfarin, pre and post procedures INR, elective or emergency orthopaedic procedures and complications were collected using a standard proforma. RESULTS. 18 patients, 12 male and 6 female were included into the study. Patients' age ranged from 47-87 with mean of 76. The indications for warfarin therapy were atrial fibrillation in 12 patients, deep vein thrombosis in 5 patients and left ventricular aneurysm in 1 patient. 18 procedures, 10 elective and 8 emergency orthopaedic procedures were carried out during period of study. Elective procedures - 7 primary joint arthroplasty, 1 revision hip arthroplasty, 1 removal of metalwork and 1 metatarsophalangeal joint fusion. Emergency procedures - 4 hip hemiarthroplasty, 2 dynamic hip screw fixation, 1 external fixator application and 1 open reduction and internal fixation of ankle. All elective admission patients were pre-assessed in clinic prior to admission and were advised to stop warfarin based on their INR level. Patients with INR 2-3 had their warfarin stopped 4 days prior to surgery while patients with INR 3-4.5 had their warfarin stopped 5 days prior to surgery. This group of patients had their INR check on admission and ranged from 1.1-1.5. This group of patients had no reversal therapy and no cancellations were made to their operation. 8 emergency admission patients had INR of 1.4-4.7 on admission with mean of 2.7. 5 patients had reversal therapy while 3 patients had no reversal therapy. Pharmacological methods used to reduce the INR were fresh frozen plasma in 1 patient and Vitamin K in 4 other patients. 2 patients that received reversal therapy had operation on day 1, 2 on day 3 and 1 on day 5. 1 patient that had no reversal therapy was operated on day 1, 1 on day 3 and 1 on day 5. Patient that received no reversal therapy and operated on day 5 of admission died post-operatively from medical complications. Mean delay for patient that had reversal therapy was 2.2 days compared to 3 days in patient with no reversal therapy. All patients in this study had prophylactic low molecular weight heparin while off warfarin. Patients were recommenced on their normal dose of warfarin the day after their operation. DISCUSSION & CONCLUSIONS. We conclude that patients on warfarin with INR 2-3 should have their warfarin stopped 4 days prior to surgery while patients with INR 3-4.5 should stop their warfarin 5 days prior to elective surgery. Trauma patients on warfarin requiring operation should have their INR reversed on admission to shorten delay in waiting time and improve outcomes


Bone & Joint 360
Vol. 11, Issue 3 | Pages 46 - 47
1 Jun 2022
Das A