When performing limb salvage operations for malignant bone tumours in skeletally immature patients, it is desirable to reconstruct the limb with a prosthesis that can be lengthened without surgery at appropriate intervals to keep pace with growth of the contra-lateral side. We have developed a prosthesis that can be lengthened non-invasively. The lengthening is achieved on the principle of electromagnetic induction. The purpose of this study was to look at our early experience with the use of the Non Invasive Distal Femoral Expandable
The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17–86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed.
The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17-86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed.
Curative resection of proximal humerus tumours is now possible in this era of limb salvage with endoprosthetic replacement considered as the preferred reconstructive option. However, it has also been linked with mechanical and non-mechanical failures such as stem fracture and aseptic loosening. One of the challenges is to ensure that implants will endure the mechanical strain under physiological loading conditions, especially crucial in long surviving patients. The objective is to investigate the effect of varying prosthesis length on the bone and implant stresses in a reconstructed humerus-prosthesis assembly after tumour resection using finite element (FE) modelling. Computed tomography (CT) scans of 10 humeri were processed in Mimics 17 to create three-dimensional (3D) cortical and cancellous solid bone models. Endoprostheses of different lengths manufactured by Stryker were modelled using Solidworks 2020. The FE models were divided into four groups namely group A consisting of the intact humerus and groups B, C and D composed of humerus-prosthesis assemblies with a body length of 40, 100 and 120 mm respectively and were meshed using linear 4-noded tetrahedral elements in 3matic 13. The models were then imported into Abaqus CAE 6.14. Isotropic linear elastic behaviour with an elastic modulus of 13400, 2000 and 208 000 MPa were assigned to the cortical bone, cancellous bone and prosthesis respectively and a Poisson's ratio of 0.3 was assumed for each material. To represent the lifting of heavy objects and twisting motion, a tensile load of 200 N for axial loading and a 5 Nm torsional load for torsional loading was applied separately to the elbow joint surface with the glenohumeral joint fixed and with all contact interfaces defined as fully bonded. A comparative analysis against literature was performed to validate the intact model. Statistical analysis of the peak von Mises stress values collected from predicted stress contour plots was performed using a one-way repeated measure of analysis of variance (with a Bonferroni post hoc test) using SPSS Statistics 26. The average change in stress of the resected models from the intact state were then determined.Introduction and Objective
Methods
Debate surrounds the optimum operative treatment of periprosthetic distal femoral fractures (PDFFs) at the level of well fixed femoral components; lateral locking plate fixation (LLP-ORIF) or distal femoral replacement (DFR). To determine which attributed the least peri-operative morbidity and mortality we performed a retrospective cohort study of 60 consecutive unilateral PDFFs of Su types II (40/60) and III (20/60) in patients ≥60 years; 33 underwent LLP-ORIF and 27 underwent DFR. The primary outcome measure was reoperation. Secondary outcomes included perioperative complications and functional mobility status. Kaplan Meier survival analysis was performed. Cox multivariable regression analysis identified risk factors for reoperation after LLP-ORIF. Mean length of follow-up was 3.8 years (range 1.0–10.4). One-year mortality was 13% (8/60). Reoperation rate was significantly higher following LLP-ORIF: 7/33 vs 0/27, p=0.008. For the endpoint reoperation, five-year survival was better following DFR: 100% compared to 70.8% (51.8 to 89.8 95%CI) (p=0.006). For the endpoint mechanical failure (including radiographic loosening) there was no difference at 5 years: ORIF 74.5% (56.3 to 92.7); DFR 78.2% (52.3 to 100), p=0.182). Reoperation following LLP-ORIF was independently associated with medial comminution: HR 10.7 (1.45 to 79.5, p=0.020). Anatomic reduction was protective against reoperation: HR 0.11(0.013 to 0.96, p=0.046). When inadequately fixed fractures were excluded differences in survival were no longer significant: reoperation (p=0.156); mechanical failure (p=0.453). Reoperation rates are higher following LLP-ORIF of low PDFFs compared to DFR. Where adequate reduction, proximal fixation and augmentation of medial comminution is used there is no difference in survival between LLP-ORIF and DFR.
Computer Tomography (CT) imaging has been limited to beam hardening artefacts until now. Literature has failed to describe sensitivity and specifity for loosening of endoprothesis in CTs, as metal artefacts have always influenced the diagnostic value of CTs. In recent years a new technology has been developed, the Dual Energy CT. Dual Energy CT scanners simultaneously scan with two tubes at different energy levels, most commonly 100kVp and 140kVp. Furthermore pictures gained from Dual Energy CTs are post-processed with monoenergetic reconstruction, which increases picture quality while further reducing metal artefacts. This promising technology has increased the diagnostic value preventing more radiation for the patients, for example in detection of kidney stones or to map lung perfusion. In the musculoskeletal imaging it has not been established yet and further clinical investigations are necessary. Thus the aim of this study is to describe sensitivity and sensibility for endoprothesis loosening of this novel technology. 53 prospective patients (31 total hip- and 22 total knee-arthoplasties) who were planned for revision surgery underwent preoperative Dual Energy CT examination. All scans were performed with a second-generation, dual-energy multi-detector CT scanner. And all pictures were post-processed with monoenergetic reconstruction. Radiologists were blinded for patient´s history. Senior consultants, who are specialized in arthroplasty of the hip and the knee, performed surgery. Intraoperative information was used as gold standard.Introduction
Material and Methods
Four patients had obvious infection confirmed by histology and/or microbiology prior to surgery. Endoprosthetic Reconstruction was performed as a 1 stage procedure in 13 and as a 2 stage in 4. Complications occurred in 5 patients. These included recurrence of infection in 1, persistent pain in 1, aseptic loosening in 1, periprosthetic fracture in 1 and a non ST myocardial infarction in 1. At the last follow-up, (mean 5years, range 1–18years) majority of patients achieved good range of motion and good mobility.
The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.Aims
Methods
The risk of haematogenic periprosthetic joint infection (PJI) after dental procedures is discussed controversially. To our knowledge, no study has evaluated infections according to the origin of infection based on the natural habitat of the bacteria. We investigated the frequency of positive monomicrobial cultures involving bacteria from oral cavity in patients with suspected PJI compared to bone and joint infections without joint prosthesis. In this retrospective study we included all patients with suspected PJI or bone and joint infection without endoprosthesis, hospitalized at our orthopaedic clinic from January 2009 through March 2014. Excluded were patients with superficial surgical site infections or missing data. Demographic, clinical and microbiological data were collected using a standardized case report form. Groups were compared regarding infections caused by oral bacteria. χ2 test or Fisher's exact test was employed for categorical variables and t-test for continuous variables.Aim
Method
Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis, for tumour, between 1997 and 2007. The mean age was 46 years, (7–87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3% and the mean TESS was 77.2%. Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7% and a mean TESS of 80.0%. Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.
Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %. Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%. Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.
Revision THA presents significant challenges for the surgeon when the proximal femur is deficient or mechanically unreliable. The aim of this study is to assess the clinical and functional results of the use of tumor enndoprosthesis to reconstruct the proximal femur when there is massive bone loss. A prospective study was conducted involving 10 cases. The follow up of the cases ranged from 12 months to 30 months with a mean period of an average of 23months. The indications for revision surgery were aseptic loosening in 9 cases and septic loosening in one case Harris hip score was used for pre and postoperative clinical evaluation of the patientsBackground
Patients and Methods
Endoprosthetic reconstruction is an established method of treatment for primary bone tumours in children. Traditionally these were implanted with cemented intramedullary fixation. Hydroxyapatite collars at the shoulder of the implant are now standard on all extremity endoprostheses, but older cases were implanted without collars. Uncemented intramedullary fixation with hydroxyapatite collars has also been used in an attempt to reduce the incidence of problems such as aseptic loosening. Currently there are various indications that dictate which method is used. To establish long term survivorship of cemented versus uncemented endoprosthesis in paediatric patients with primary bone tumours.Background
Aims
Complications included: Superficial infection (1), deep infection (1); Recurrence 2; Improper cementing (2); Neuropraxia [radial nerve] (8); Subluxation of prosthesis head (8); Post radiotherapy skin necrosis and contracture (1); 4 patients died.
Bipolar hip arthroplasty was introduced to alleviate the problems of hip pain, acetabular protrusion and femoral stem loosening associated with unipolar prosthesis. Earlier generation bipolar endoprosthesis used to cause varus fixation of outer head which led to the unacceptably high incidence of dislocation, component disassembly and fractures of the polyethylene bearing insert. Second generation endoprosthesis with a self centering mechanism were introduced to overcome these problems. This new design incorporates a polar offset by setting the center of rotation of the inner head proximal to the center of rotation of the outer head, which generates a valgus producing moment at the outer cup. There is a controversy whether this mechanism works in vivo, more so in indigenous prosthesis. A retrospective observational study was done on 37 subjects, which included 21 males and 16 females. The first radiograph was taken with the patient standing and bearing full weight over the endoprosthetic leg and abducting the contra lateral limb as much as possible. The second radiograph was taken with the patient standing neutral and bearing weight on both the legs. Abduction and adduction views were then taken in supine position. The radiographs were analyzed using the method similar to that of Drinker and Murray. The adductive motion from abduction to neutral position is within the range of inner bearing oscillation. Modified Harris Hip Score was used to evaluate the patients clinically. Results were analyzed using Wilcoxon Matched-Pairs Signed-Ranks Test, Students t-test and Karl Pearson correlation statistics. The mean outer head alignment changed from 42.46 degrees ±13.62 (range 10 to 72 degrees) to 31.93 degrees ± 10.59 (range 8 to 50 degrees) in moving from abduction to neutral position in weight bearing position. The analysis showed that 68.66% of the total motion occurred at the outer bearing in weight bearing position whereas 73.86% of the total motion occurred at the outer bearing in supine position. The difference between distribution of motion between supine and weight bearing position was not found to be statistically different using Wilcoxon Matched-Pairs Signed-Ranks Test (p = 0.3164) and unpaired students t test (p = 0.35). No correlation was found between weight of the patient and time of follow up with outer head alignment and differential distribution of motion. Self centering mechanism of bipolar endoprosthesis works in vivo under physiological loads and aligns the cup in neutral or valgus position till an average follow up of 10 months. Though the motion occurs at both the bearing surfaces outer bearing motion clearly predominated in both weight bearing as well as supine position.
With a new mechanical navigation system for the cup with a special cup probe and guiding system the best position is found intraoperatively according to ROM, impingement, luxation and tension of the muscles.
The higher resisting torque against dislocation and the large range of motion due to the enlarged effective head diameter substantiate the use of eccentric dual-mobility cups in case of total hip joint instability [1,2]. As a result of force-dependent self-centering mechanism, an increased movement of the intermediate-component can be expected whose effect on wear propagation is unknown so far. Currently available hip joint simulators are only able to vary the load by the absolute value and not by the direction of resulting force. Therefore, the uniaxial force transmission may lead to a unique and stable alignment of the intermediate-component during testing. The purpose of this numerical study was to evaluate relative movements of the intermediate-component during daily life activities with respect to wear propagation. The numerical analysis was based on a standard dual-mobility system consisting of a polished metallic cup, a UHMWPE intermediate-component (40 mm outer diameter) with an eccentric offset of 2 mm and a 28 mm ceramic femoral head [Fig. 1]. The relative motion of the intermediate-component was affected by the geometrically generated self-centering torque (TC) and the friction torque for inner (TFi) and outer (TFo) articulation around the centre of rotation Z1[Fig. 2]. In order to consider lubrication conditions the lambda ratio was estimated for different daily life activities [3], including the calculation of composite roughness and minimum film thickness for a ball-on-plate configuration. The friction torque was related to the product of load (Introduction:
Method: