Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 79 - 79
1 Dec 2022
Langohr GD Mahaffy M Athwal G Johnson JA
Full Access

Patients receiving reverse total shoulder arthroplasty (RTSA) often have osseous erosions because of glenohumeral arthritis, leading to increased surgical complexity. Glenoid implant fixation is a primary predictor of the success of RTSA and affects micromotion at the bone-implant interface. Augmented implants which incorporate specific geometry to address superior erosion are currently available, but the clinical outcomes of these implants are still considered short-term. The objective of this study was to investigate micromotion at the glenoid-baseplate interface for a standard, 3 mm and 6 mm lateralized baseplates, half-wedge, and full-wedge baseplates. It was hypothesized that the mechanism of load distribution from the baseplate to the glenoid will differ between implants, and these varying mechanisms will affect overall baseplate micromotion. Clinical CT scans of seven shoulders (mean age 69 years, 10°-19° glenoid inclinations) that were classified as having E2-type glenoid erosions were used to generate 3D scapula models using MIMICS image processing software (Materialise, Belgium) with a 0.75 mm mesh size. Each scapula was then repeatedly virtually reconstructed with the five implant types (standard,3mm,6mm lateralized, and half/full wedge; Fig.1) positioned in neutral version and inclination with full backside contact. The reconstructed scapulae were then imported into ABAQUS (SIMULIA, U.S.) finite element software and loads were applied simulating 15°,30°,45°,60°,75°, and 90° of abduction based on published instrumented in-vivo implant data. The micromotion normal and tangential to the bone surface, and effective load transfer area were recorded for each implant and abduction angle. A repeated measures ANOVA was used to perform statistical analysis. Maximum normal micromotion was found to be significantly less when using the standard baseplate (5±4 μm), as opposed to the full-wedge (16±7 μm, p=0.004), 3 mm lateralized (10±6 μm, p=0.017), and 6 mm lateralized (16±8 μm, p=0.007) baseplates (Fig.2). The half-wedge baseplate (11±7 μm) also produced significantly less micromotion than the full-wedge (p=0.003), and the 3 mm lateralized produced less micromotion than the full wedge (p=0.026) and 6 mm lateralized (p=0.003). Similarly, maximum tangential micromotion was found to be significantly less when using the standard baseplate (7±4 μm), as opposed to the half-wedge (12±5 μm, p=0.014), 3 mm lateralized (10±5 μm, p=0.003), and 6 mm lateralized (13±6 μm, p=0.003) baseplates (Fig.2). The full wedge (11±3 μm), half-wedge, and 3 mm lateralized baseplate also produced significantly less micromotion than the 6 mm lateralized (p=0.027, p=012, p=0.02, respectively). Both normal and tangential micromotion were highest at the 30° and 45° abduction angles (Fig.2). The effective load transfer area (ELTA) was lowest for the full wedge, followed by the half wedge, 6mm, 3mm, and standard baseplates (Fig.3) and increased with abduction angle. Glenoid baseplates with reduced lateralization and flat backside geometries resulted in the best outcomes with regards to normal and tangential micromotion. However, these types of implants are not always feasible due to the required amount of bone removal, and medialization of the bone-implant interface. Future work should study the acceptable levels of bone removal for patients with E-type glenoid erosion and the corresponding best implant selections for such cases. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 52 - 52
1 Jul 2020
Abdic S Knowles N Johnson J Walch G Athwal G
Full Access

Superiorly eroded glenoids in cuff tear arthropathy represent a surgical challenge for reconstruction. The bone loss orientation and severity may influence glenoid component fixation. This computed-tomography study quantifies both the degree of erosion and orientation in superiorly eroded Favard E2 glenoids. We hypothesized that the erosion in E2 glenoids does not occur purely superiorly, rather, it is oriented in a predictable posterosuperior orientation with a largely semicircular line of erosion. Three-dimensional reconstructions of 40 shoulders with E2 glenoids (28 female, 12 male patients) at a mean age of 74 years (range, 56–88 years) were created from computed-tomography images. Point coordinates were extracted from each construct to analyze the morphologic structure. The anatomical location of the supra- and infraglenoid tubercle guided the creation of a superoinferior axis, against which the orientation angle of the erosion was measured. The direction and, thus, orientation of erosion was calculated as a vector. By placing ten point coordinates along the line of erosion and creating a circle of best fit, the radius of the circle was placed orthogonally against a chord that resulted by connecting the two outermost points along the line of erosion. To quantify the extent of curvature of the line of erosion between the paleo- and neoglenoid, the length of the radius of the circle of best fit was calculated. Individual values were compared against the mean of circle radii. The area of bony erosion (neoglenoid), was calculated as a percentage of the total glenoid area (neoglenoid + paleoglenoid). The severity of the erosion was categorized as mild (0% to 33%), moderate (34% to 66%), and severe erosion (>66%). The mean orientation angle between the vector of bony erosion and the superoinferior axis of the glenoid was 47° ± 17° (range, 14° – 74°) located in the posterosuperior quadrant of the glenoid, resulting in the average erosion being directed between the 10 and 11 o'clock position (right shoulder). In 63% of E2 cases, the line of erosion separating the paleo- and neoglenoids was more curved than the average of all bony erosions in the cohort. The mean surface area of the neoglenoid was 636 ± 247 mm2(range, 233 – 1,333 mm2) and of the paleoglenoid 311 ± 165 mm2(range, 123 – 820 mm2), revealing that, on average, the neoglenoids consume 67% of the total glenoid surface. The extent of erosion of the total cohort was subdivided into one mild (2%), 14 moderate (35%) and 25 severe (62%) cases. Using a clock-face for orientation, the average orientation of type E2 glenoid defects was directed between the 10 and 11 o'clock position in a right shoulder, corresponding to the posterosuperior glenoid quadrant. Surgeons managing patients with E2 type glenoids should be aware that a superiorly described glenoid erosion is oriented in the posterosuperior quadrant on the glenoid clock-face when viewed intra-operatively. Additionally, the line of erosion in 63% of E2 glenoids is substantially curved, having a significant effect on bone removal techniques when using commercially available augments for defect reconstruction


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 37 - 37
1 Dec 2022
Fleet C de Casson FB Urvoy M Chaoui J Johnson JA Athwal G
Full Access

Knowledge of the premorbid glenoid shape and the morphological changes the bone undergoes in patients with glenohumeral arthritis can improve surgical outcomes in total and reverse shoulder arthroplasty. Several studies have previously used scapular statistical shape models (SSMs) to predict premorbid glenoid shape and evaluate glenoid erosion properties. However, current literature suggests no studies have used scapular SSMs to examine the changes in glenoid surface area in patients with glenohumeral arthritis. Therefore, the purpose of this study was to compare the glenoid articular surface area between pathologic glenoid cavities from patients with glenohumeral arthritis and their predicted premorbid shape using a scapular SSM. Furthermore, this study compared pathologic glenoid surface area with that from virtually eroded glenoid models created without influence from internal bone remodelling activity and osteophyte formation. It was hypothesized that the pathologic glenoid cavities would exhibit the greatest glenoid surface area despite the eroded nature of the glenoid and the medialization, which in a vault shape, should logically result in less surface area. Computer tomography (CT) scans from 20 patients exhibiting type A2 glenoid erosion according to the Walch classification [Walch et al., 1999] were obtained. A scapular SSM was used to predict the premorbid glenoid shape for each scapula. The scapula and humerus from each patient were automatically segmented and exported as 3D object files along with the scapular SSM from a pre-operative planning software. Each scapula and a copy of its corresponding SSM were aligned using the coracoid, lateral edge of the acromion, inferior glenoid tubercule, scapular notch, and the trigonum spinae. Points were then digitized on both the pathologic humeral and glenoid surfaces and were used in an iterative closest point (ICP) algorithm in MATLAB (MathWorks, Natick, MA, USA) to align the humerus with the glenoid surface. A Boolean subtraction was then performed between the scapular SSM and the humerus to create a virtual erosion in the scapular SSM that matched the erosion orientation of the pathologic glenoid. This led to the development of three distinct glenoid models for each patient: premorbid, pathologic, and virtually eroded (Fig. 1). The glenoid surface area from each model was then determined using 3-Matic (Materialise, Leuven, Belgium). Figure 1. (A) Premorbid glenoid model, (B) pathologic glenoid model, and (C) virtually eroded glenoid model. The average glenoid surface area for the pathologic scapular models was 70% greater compared to the premorbid glenoid models (P < 0 .001). Furthermore, the surface area of the virtual glenoid erosions was 6.4% lower on average compared to the premorbid glenoid surface area (P=0.361). The larger surface area values observed in the pathologic glenoid cavities suggests that sufficient bone remodelling exists at the periphery of the glenoid bone in patients exhibiting A2 type glenohumeral arthritis. This is further supported by the large difference in glenoid surface area between the pathologic and virtually eroded glenoid cavities as the virtually eroded models only considered humeral anatomy when creating the erosion. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 22 - 22
10 May 2024
Arumugam M
Full Access

INTRODUCTION. Tuberculosis (TB) is a public health challenge. However, musculoskeletal involvement represents 10–15% of all extrapulmonary cases. Upper extremity involvement is extremely rare. The slow progressive course of clinical symptoms and lack of radiological signs lead to difficulties in establishing early diagnosis. Hence, the patients who have tuberculosis of the wrist are usually misdiagnosed. We report 5 cases of tuberculosis of the wrist seen in our unit from the year 2012 to 2021. METHODS. Cases were retrospectively evaluated on demographics, nature of history, clinical presentation, culture finding, and histopathological findings from 2012 to 2021 at our unit. RESULTS. A total of 5 cases were evaluated retrospectively. Three patients were more than 60 years old and two were less than 30 years old. Four of the patients presented with wrist swelling 2 of them had wrist pain and only 1 patient had discharge from the wound. The duration of the symptoms ranges from 2 months to 3 years. Only one of the patients had a history of pulmonary TB contact whereas the others didn't. All patients underwent surgery. All of the patients had positive cultures for Mycobacterium tuberculosis complex and histopathological examination showed necrotizing granulomatous inflammation from specimens taken intraoperatively, which confirmed the diagnosis of tuberculosis of the wrist. DISCUSSIONS. Our cases show that the common presentation of tuberculosis of the wrist was comparable to other literature. Most of the patients presented with chronic wrist swelling with or without wrist pain. The diagnosis of the disease was delayed an average of 10 - 12 months from symptoms onset to diagnosis. S. Bayram et al reported a case where the diagnosis was made 45 months later. Due to its rarity, it often is misdiagnosed, resulting in delays in the proper treatment. CONCLUSION. The diagnosis of the TB wrist remains difficult because of insidious and non-specific. presentation. However, early diagnosis is essential to avoid delays in treatment and complications. Hence, chronic wrist pain, and swelling with or without unexplained bone erosion around the wrist area must be highly suspected of being osteoarticular tuberculosis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 29 - 29
1 Jun 2023
McCabe F Wade A Devane Y O'Brien C McMahon L Donnelly T Green C
Full Access

Introduction. Aneurysmal bone cysts commonly found in lower limbs are locally aggressive masses that can lead to bony erosion, instability and fractures. This has major implications in the lower limbs especially in paediatric patients, with potential growth disturbance and deformity. In this case series we describe radical aneurysmal bone cyst resection and lower limb reconstruction using cable transport and syndesmosis preservation. Materials & Methods. Case 1 - A 12-year-old boy presented with a two-week history of atraumatic right ankle pain. An X-ray demonstrated a distal tibia metaphyseal cyst confirmed on biopsy as an aneurysmal bone cyst. The cyst expanded on interval X-rays from 5.5cm to 8.5cm in 9 weeks. A wide-margin en-bloc resection was performed leaving a 13.8cm tibial defect. A cable transport hexapod frame and a proximal tibial osteotomy was performed, with syndesmosis screw fixation. The transport phase lasted 11 months. While in frame, the boy sustained a distal femur fracture from a fall. The femur and the docking site were plated at the same sitting and frame removed. At one-year post-frame removal he is pain-free, with full ankle dorsiflexion but plantarflexion limited to 25 degrees. He has begun graduated return to sport. Results. Case 2 - A 12-year-old girl was referred with a three-month history of lateral left ankle swelling. X-ray demonstrated an aneurysmal bone cyst in the distal fibula metaphysis. The cyst grew from 4.2 × 2.3cm to 5.2 × 3.32cm in 2 months. A distal fibula resection (6.2cm) with syndesmosis fixation and hexapod cable transport frame were undertaken. The frame was in situ for 13 weeks and during this time she required an additional osteotomy for premature consolidation and had one pin site infection. After 13 weeks a second syndesmosis screw was placed, frame removed, and a cast applied. 3 months later she had fibular plating, BMAC and autologous iliac crest bone graft for slow union. At 3 years post-operative she has no evidence of recurrence, is pain-free and has no functional limitation. Conclusions. We describe two cases of ankle syndesmosis preservation using cable transport for juxta-articular aneurysmal bone cysts. This allows wide resection to prevent recurrence while also preserving primary ankle stability and leg length in children. Both children had a minor complication, but both had an excellent final outcome. Cable bone transport and prophylactic syndesmosis stabilization allows treatment of challenging juxta-articular aneurysmal bone cysts about the ankle. These techniques are especially useful in large bone defects


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 59 - 59
1 Mar 2021
Beauchamp-Chalifour P Pelet S Belhumeur V Angers-Goulet M Belzile E
Full Access

Worldwide, it is expected that 6.3 million patients will sustain a hip fracture in 2050. Hemiarthroplasty is commonly practiced for displaced femoral neck fractures. The choice between unipolar (UH) or bipolar (BH) hemiarthroplasty is still controversial. The objective of this study was to assess the effect on hip function of BH compared to UH for a displaced femoral neck fracture in elderly patients. We conducted a systematic review and meta-analysis of randomized controlled trials comparing BH to UH. Data sources were Medline, Embase, Cochrane Library and Web of Science. All data was pooled in Review Manager (RevMan) version 5.3 software. Selection of the studies included, data abstraction, data synthesis, risk of biais and quality of evidence evaluation was done independently by two authors. Our primary outcome was postoperative hip function. Secondary outcomes were health-related quality of life (HRQoL), acetabular erosion and postoperative complications. 13 randomized controlled trials (n=2256) were eligible for the meta-analysis. There was no difference in hip function scores (standardized mean difference of 0.33 [−0.09–0.75, n=864, I. 2. = 87%,]). Patients with bipolar heads had higher Health-Related Quality of Life scores than patients with unipolar heads (mean difference in EQ-5D scores of 0.12 [0.04–0.19, n=550, I. 2. = 44%]). The use of BH decreased the incidence of acetabular erosion (relative risk of 0.37 [0.17–0.83, n=525, I. 2. = 0%]). There was no relative risk difference for mortality, dislocation, revision and infection. Due to the high heterogeneity between the studies included, it is still unclear whether patients undergoing BH have better hip function than patients undergoing UH. Although, health-related quality of life (HRQoL) may be improved. Future research could be conducted to determine whether a BH offers a better quality of life than UH to geriatric patients undergoing surgery. More precise assessment scores could be developed to better evaluate postoperative outcomes


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 139 - 139
1 Jul 2020
Sims L Aibinder W Faber KJ King GJ
Full Access

Essex-Lopresti injuries are often unrecognized acutely with resulting debilitating adverse effects. Persistent axial forearm instability may affect load transmission at both the elbow and wrist, resulting in significant pain. In the setting of both acute and chronic injuries metallic radial head arthroplasty has been advocated, however there is little information regarding their outcome. The purpose of this study was to assess the efficacy of a radial head arthroplasty to address both acute and chronic Essex-Lopresti type injuries. A retrospective review from 2006 to 2016 identified 11 Essex-Lopresti type injuries at a mean follow-up of 18 months. Five were diagnosed and treated acutely at a mean of 11 days (range, 8 to 19 days) from injury, while 6 were treated in a delayed fashion at a mean of 1.9 years (range, 2.7 months to 6.2 years) from injury with a mean 1.5 (range, 0 to 4) prior procedures. The cohort included 10 males with a mean age was 44.5 years (range, 28 to 71 years). A smooth stem, modular radial head arthroplasty was used in all cases. Outcomes included range of motion and radiographic findings such as ulnar variance, capitellar erosion, implant positioning and implant lucency using a modification of the method described by Gruen. Reoperations, including the need for ulnar shortening osteotomy, were also recorded. Three patients in each group (55%) reported persistent wrist pain. The mean ulnar variance improved from +5 mm (range, 1.8 to 7 mm) to +3.7 mm (range, 1 to 6.3 mm) at the time of final follow-up or prior to reoperation. Three (50%) patients in the chronic group underwent a staged ulnar shortening osteotomy (USO) to correct residual ulnar positive variance and to manage residual wrist pain. There were no reoperations in the acute group. Following USO, the ulnar variance in those three cases improved further to +3.5, +2.1, and −1.1 mm. No radial head prostheses required removal. Capitellar erosion was noted in five (45%) elbows, and was rated severe in one, moderate in two, and mild in two. Lucency about the radial head prosthesis stem was noted in eight (73%) cases, and rated as severe in 2 (18%), based on Gruen zones. Treatment of acute and chronic Essex-Lopresti lesions with radial head arthroplasty often results in persistent wrist pain. In the chronic setting, a planned USO was often necessary to restore axial forearm stability after radial head arthroplasty. Essex-Lopresti lesions represent a rare clinical entity that are difficult treat, particularly in the chronic setting. Early recognition and management with a smooth stem modular radial head arthroplasty may provide improved outcomes compared to chronic reconstruction


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 64 - 64
1 Aug 2020
Nooh A Marc-antoine R Turcotte R Alaseem A Goulding K
Full Access

The use of endoprosthesis implants is frequent for tumours involving the proximal third of the femur and not amenable to primary arthroplasty or internal fixation. In this population, these implants are preferentially cemented given poor bone quality associated with systemic diseases and treatments. Loosening is a common complication of these implants that have been linked to poor bone quality, type of implants and importantly cementing technique. Thus, these techniques vary between different surgeons and based mainly on previous experience. One of the most successful cementing techniques in the arthroplasty literature is the French paradox. This technique involves removing the cancellous bone of the proximal femoral metaphysis and selects the largest stem to tightly fit the created cavity delineated by cortical bone. Cementing the implant results in a very thin cement layer that fills the inconsistent gaps between the metal and the bone. To our knowledge, no previous report exists in the literature assessing loosening in proximal femur replacement using the French paradox cementing technique. In this study, we sought to examine (1) rates of loosening in proximal femur replacement, and (2) the oncological outcomes including tumour recurrence and implant related complications. A retrospective study of 42 patients underwent proximal femur replacement between 1990 and 2018 at our institution. Of these, 30 patients met our inclusion criteria. Two independent reviewers have evaluated the preoperative and the most recent postoperative radiographs using the International Society of Limb Salvage (ISOLS) radiographic scoring system and Gruen classification for femoral stem loosening. Additionally, the acetabulum was evaluated for erosion according to the criteria of Baker et al. The mean age of this cohort was 60.5 (19–80), with 60% being males. The primary origin was metastatic in 17 (56.7%) patients, bone sarcoma in 10 (33.3%) patients and soft tissue sarcoma in 3 (10%) patients. Pathological fractures were present in 11 (36.7%) patients. Seven (23.3%) patients had prior intramedullary nailing. Preoperative radiotherapy was used in 8 (26.7%) and postoperative radiotherapy in 17 (56.7%) patients. The mean clinical follow-up was 25.2±26.3 months and the mean radiographical follow-up was 24.8±26 months. The mean ISOLS score for both reviewers was found to be 89±6.5% and 86.5±6.1%, respectively. Additionally, the first reviewer found two patients to be possibly loos (6.7%) compared to one (3.3%) patient for the second reviewer. No components scored as probably or definitely loose and non-required revision for either loosening or metal failure. Furthermore, both reviewers showed no acetabular erosion in 25 (83.3%) and 24 (80%) patients, respectively. On the other hand, the overall rate of complications was 36.6% with 11 complications reported in 30 patients. Local recurrence occurred in five (16.6%) patients. Prosthetic Dislocation was the most frequent complications with eight dislocations in four patients. Despite complications, our results showed no radiographic evidence of stem loosening. Cementing proximal femur prosthesis with a tight canal fit and with a thin cement mantle appears to be a viable option at short and medium term


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 37 - 37
1 Jun 2018
Dorr L
Full Access

Dorr bone type is both a qualitative and quantitative classification. Qualitatively on x-rays the cortical thickness determines the ABC type. The cortical thickness is best judged on a lateral x-ray and the focus is on the posterior cortex. In Type A bone it is a thick convex structure (posterior fin of bone) that can force the tip of the tapered implant anteriorly – which then displaces the femoral head posteriorly into relative retroversion. Fractures in DAA hips have had increased fractures in Type A bone because of the metaphyseal-diaphyseal mismatch (metaphysis is bigger than diaphysis in relation to stem size). Quantitatively, Type B bone has osteoclastic erosion of the posterior fin which proceeds from proximal to distal and is characterised by flattening of the fin, and erosive cysts in it from osteoclasts. A tapered stem works well in this bone type, and the bone cells respond positively. Type C bone has loss of the entire posterior fin (stove pipe bone), and the osteoblast function at a low level with dominance of osteoclasts. Type C is also progressive and is worse when both the lateral and AP views show a stove pipe shape. If just the lateral x-ray has thin cortices, and the AP has a tapered thickness of the cortex a non-cemented stem will work, but there is a higher risk for fracture because of weak bone. At surgery Type C bone has “mushy” cancellous bone compared to the hard structure of type A. Tapered stems have high risk for loosening because the diaphysis is bigger than the metaphysis (opposite of Type A). Fully coated rod type stems fix well, but have a high incidence of stress shielding. Cemented fixation is done by surgeons for Type C bone to avoid fracture, and insure a comfortable hip. The large size stem often required to fit Type C bone causes an adverse-stem-bone ratio which can cause chronic thigh pain. I cement patients over age 70 with Type C bone which is most common in women over that age


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 61 - 61
1 Jan 2013
Rajagopalan S Barbeseclu M Moonot P Sangar A Aarvold A Taylor H
Full Access

Background. As hallux valgus (HV) worsens clinical and radiological signs of arthritis develop in metatarsophalangeal joint due to incongruity of joint surfaces. The purpose of this prospective study was to determine if intraoperative mapping of articular erosion of the first metatarsal head, base of the proximal phalanx, and tibial and fibular sesamoids can be correlated to clinical and/or radiographic parameters used during the preoperative assessment of the HV deformity. Materials and methods. We analysed 50 patients prospectively who underwent surgery between Jan 2009-Jan 2010. Patients with a known history of previous first metatarsophalangeal joint surgical intervention, trauma, or systemic arthritis were excluded from analysis. Preoperative demographics and AOFAS score were recorded. Intraoperative evaluation and quantification of the first metatarsal head, base of the proximal phalanx, and sesamoid articular cartilage erosion was performed. Cartilage wear was documented using International Cartilage Research Society grading. Results and Discussion. P. Bock et al have showed that the extent of cartilage lesions were clearly correlated with the degree of hallux valgus angle proving that a malaligned joint is more prone to cartilage degeneration. Kristen et al have described a correlation between a higher pre-operative hallux valgus angle and the post-operative Kitaoka et al score. The higher the preoperative hallux valgus angle, the lower the post-operative score. Our series showed the mean IMA is 15 degrees. The mean AOFAS score was 62. There was a significant positive correlation between hallux valgus angle and AOFAS score. We also found correlation between sesamoid wear and AOFAS score and HV angle. Conclusion. We conclude that preoperative clinical parameters (ie, age) and radiographic measurements (ie, HV, IMA) directly define the incidence and location of articular erosion and are helpful in the preoperative assessment of the HV deformity


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 36 - 36
1 Jul 2020
Lian WS Wang F Hsieh CK
Full Access

Aberrant infrapatellar fat metabolism is a notable feature provoking inflammation and fibrosis in the progression of osteoarthritis (OA). Irisin, a secretory subunit of fibronectin type III domain containing 5 (FNDC5) regulate adipose morphogenesis, energy expenditure, skeletal muscle, and bone metabolism. This study aims to characterize the biological roles of Irisin signaling in an infrapatellar fat formation and OA development. Injured articular specimens were harvested from 19 patients with end-stage knee OA and 11 patients with the femoral neck fracture. Knee joints in mice that overexpressed Irisin were subjected to intra-articular injection of collagenase to provoke OA. Expressions of Irisin, adipokines, and MMPs probed with RT-quantitative PCR. Infrapatellar adiposity, articular cartilage damage, and synovial integrity verified with histomorphometry and immunohistochemistry. Infrapatellar adipose and synovial tissues instead of articular cartilage exhibited Irisin immunostaining. Human OA specimens showed 40% decline in Irisin expression than the non-OA group. In vitro, the gain of Irisin function enabled synovial fibroblasts but not chondrocytes to display minor responses to the IL-1β provocation of MMP3 and MMP9 expression. Of note, Irisin signaling reduced adipogenic gene expression and adipocyte formation of mesenchymal progenitor cells. In collagenase-mediated OA knee pathogenesis, forced FNDC5 expression in articular compromised the collagenase-induced infrapatellar adipose hypertrophy, synovial hypercellularity, and membrane hyperplasia. These adipose-regulatory actions warded off the affected knees from cartilage destruction and gait aberrance. Likewise, intra-articular injection of Irisin recombinant protein mitigated the development of infrapatellar adiposity and synovitis slowing down the progression of cartilage erosion and walking profile irregularity. Affected joints and adipocytes responded to the Irisin recombinant protein treatment by reducing the expressions of cartilage-deleterious adipokines IL-6, leptin, and adiponectin through regulating PPAR&gamma, function. Irisin dysfunction is relevant to the existence of end-stage knee OA. Irisin signaling protects from excessive adipogenesis of mesenchymal precursor cells and diminished inflammation and cartilage catabolism actions aggravated by adipocytes and synovial cells. This study sheds emerging new light on the Irisin signaling stabilization of infrapatellar adipose homeostasis and the perspective of the therapeutic potential of Irisin recombinant protein for deescalating knee OA development


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 71 - 71
1 Jul 2020
Mahaffy M Athwal G Johnson J Knowles N Berkmortel C Abdic S Walch G
Full Access

This study examined the regional variations of cortical and cancellous bone density present in superiorly eroded glenoids. It is hypothesized that eroded regions will contain denser bone in response to localized stress. The shift in natural joint articulation may also cause bone resorption in areas opposite the erosion site. Clinical CT scans were obtained for 32 shoulders (10m/22f, mean age 72.9yrs, 56–88yrs) classified as having E2-type glenoid erosion. The glenoid was divided into four measurement regions - anterior, inferior, posterior, and superior - as well as five depth regions. Depth regions were segmented in two-millimeter increments from zero to 10 millimeters, beginning at the center of the glenoid surface. A repeated-measures multiple analysis of variance (RM-MANOVA) was performed using SPSS statistical software to look for differences and interactions between mean densities in each depth, quadrant, and between genders. A second RM-MANOVA was performed to examine effects of gender and quadrant on cortical to cancellous bone volume ratios. Significance was set at p < 0 .05. Quadrant and depth variables showed significant multivariate main effects (p 0.147 respectively). Quadrant, depth, and their interaction showed significant univariate main effects for cortical bone (p≤0.001) and cancellous bone (p < 0 .001). The lowest bone density was found to be in the inferior quadrant for cancellous bone (307±50 HU, p < 0 .001). The superior quadrant contained the highest mean density for cortical bone (895±97 HU), however it was only significantly different than in the posterior quadrant (865±97 HU, p=0.022). As for depth, it was found that cortical bone is most dense at the glenoid surface (zero to two millimeters, 892±91 HU) when compared to bone at two to eight millimeters in depth (p < 0 .02). Cancellous bone was also most dense at the surface (352±51 HU), but only compared to the eight to 10 millimeters depth (p=0.005). Cancellous bone density was found to decrease with increasing depth. For cortical-to-cancellous bone volume ratios, the inferior quadrant (0.37±0.28) had a significantly lower ratio than all other quadrants (p < 0 .001). The superoposterior region of the glenoid was found to have denser cancellous bone and a high ratio of cortical to cancellous bone, likely due to decreased formation of cancellous bone and increased formation of cortical bone, in response to localized stresses. The inferior quadrant was found to have the least dense cortical and cancellous bone, and the lowest volume of cortical bone relative to cancellous bone. Once again, this is likely due to reduction in microstrain responsible for bone adaptation via Wolff's law. The density values found in this study generally agree with the range of values found in previous studies of normal and arthritic glenoids. An important limitation of this study is the sizing of measurement regions. For a patient with a smaller glenoid, a depth measurement of two millimeters may represent a larger portion of the overall glenoid vault. Segments could be scaled for each patient based on a percentage of each individual's glenoid size


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 18 - 18
1 Jul 2020
Pattappa G Koch M Weber J Lang S Bohrer A Johnstone B Docheva D Zellner J Angele P Krueckel J Franke D
Full Access

Osteoarthritis (OA) is one of the most prevalent joint diseases involving progressive and degenerative changes to cartilage resulting from a variety of etiologies including post-traumatic incident or aging. OA lesions can be treated at its early stages through cell-based tissue engineering therapies using Mesenchymal Stem Cells (MSCs). In vivo models for evaluating these strategies, have described both chondral (impaction) and osteochondral (biopsy punch) defects. The aim of the investigation was to develop a compact and reproducible defect inducing post-traumatic degenerative changes mimicking early OA. Additionally, a pilot study to evaluate the efficacy of MSC-hydrogel treatment was also assessed. Surgery was performed on New Zealand white rabbits (male, 5–8 months old) with defects created on medial femoral condyle. For developing an appropriate defect, three approaches were used for evaluation: a biopsy punch (n = three at six and twelve weeks), an impaction device1 (n = three at six and twelve weeks) and a dental drill model (n = six at six and twelve weeks). At stated time points, condyles were harvested and decalcified in 10% EDTA, then embedded in Tissue-Tek and sectioned using a cryostat. Upon identification of region of interest, sections were stained with Safranin-O/Fast green and scored using OARSI scoring system by two blinded observers2. For the pilot study, autologous bone marrow was harvested from rabbits and used to isolate and expand MSCs. The Dental drill model was applied to both knee condyles, left untreated for six weeks at which stage, PKH26 fluorescently labelled MSCs were seeded into a hyaluronic acid hydrogel (TETEC). Repair tissue was removed from both condyles and MSC-hydrogel was injected into the left knee, whilst right knee was left empty. Rabbits were sacrificed at one (n = 1), six (n = 3) and twelve (n = 3) weeks post-treatment, processed as previously described and cartilage regeneration evaluated using Sellers score3. Impacted condyles exhibited no observed changes histologically (Mean OARSI score = 1 + 1), whereas biopsy punched and dental drilled defects demonstrated equal signs of cartilage erosion (OARSI score = 3 + 1) at assessed time points. However, biopsy punched condyles formed a diffusive defect, whereas dental drilled condyles showed a more defined, compact and reproducible defect. In the pilot study, PKH-labelled MSCs were observed at one and six weeks post-implantation within the defect space where hydrogel was injected. Tissue regeneration assessment indicated no difference between empty (Mean Sellers score = 14 + 2) and MSC treated defects (Sellers score = 16 + 5) at six weeks post-injection. At twelve weeks, MSC treated defects showed improved tissue regeneration with substantial subchondral bone restoration and good integration of regenerative cartilage with surrounding intact tissue (Sellers score = 10 + 1), whereas untreated defects showed no change in regeneration compared to six weeks (Sellers score = 16 + 2). Dental drill model was found to be the appropriate strategy for investigating early OA progression and treatment. Application of MSCs in defects showed good cartilage regeneration after twelve weeks application, indicating their promise in the treatment of early OA defects


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 117 - 117
1 May 2016
Park K Kim D Lee G Rim Y
Full Access

Introduction. Total hip arthroplasty (THA) is the most common surgery performed for complications of bipolar arthroplasty. The present study evaluated the functional results and complications associated with this surgery. Patients and Methods. Forty eight hips (48 patients) who had conversion of bipolar arthroplasty to THA between 1998 June and 2013 June, and who were followed-up for more than one year were evaluated. Twenty one hips had conversion surgery to THA using a Fitmore cup with metal-on-metal articulation (28 mm head). Six hips had surgery using the SecurFit cup and three hips, using the Lima LTO cup with ceramic-on-ceramic articulation (28 mm or 32 mm head). Eighteen hips had surgery using a large head metal-on-metal bearing: –MMC (seven hips), ACCIS (six hips) and Magnum (five hips). The average time of follow-up duration was 3.9 years (range, 1.0–11.3). There were 22 men and 26 women between the ages of 28 and 80 years (average, 68.9 years) at the time of conversion surgery. Conversion arthroplasty was performed for acetabular erosion without femoral stem loosening in 19 hips, acetabular cartilage erosion with femoral stem loosening in 13 hips, periprosthetic fracture in 12 hips, and recurrent dislocation in four hips. Results were evaluated using Harris hip score (HHS) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) score. The radiographs were analyzed for evidence of acetabular and femoral osteolysis or loosening. The complications were evaluated. Results. The time interval between hemiarthroplasty and conversion total hip prosthesis was 6.7 years on average (range, 5 months to 12 years). Pain was the leading sign in all patients. Average HHS improved from 42 preoperatively (range, 34–67) to 86 (range, 65 – 97) postoperatively. The average total WOMAC score improved from 47 (range, 32–67) to 22 (range, 9–44) postoperatively. All the patients operated for groin pain reported significant improvement in their symptoms. Radiological evaluation showed good bony ingrowth and stability of all the femoral components. None of the acetabular component showed migration, loosening, wear, or osteolysis at last follow-up. Complications occurred in five hips. One dislocation and one recurrent dislocation were encountered in isolated acetabular revision hips; whereas one single dislocation, one recurrent dislocation, and one trochanteric nonunion occurred in the hips with revision of both components. All dislocations were occurred in hips with a femoral head size of 28 mm. Dislocations were managed by closed reduction, and none of the patients required revision for dislocation. Conclusions. Conversion THA after symptomatic bipolar arthroplasty can offer reliable pain relief and functional improvement. The perioperative complications approximate those of revision THAs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 380 - 380
1 Dec 2013
Kretzer JP Pohl V Zeifang F Buelhoff M Sonntag R Reinders J
Full Access

Hemi shoulder arthroplasty is an attractive treatment for shoulder arthritis in particular if the natural glenoid is still intact. However, comparing the clinical results of hemi and total shoulder arthroplasty clearly shows lower survival for the hemi arthroplasty. One of the most common reasons for revision surgery is gleniod erosion, where the cartilage or bone is worn of. Aim of the current study was to analyse if the metallic articular surface of retrieved hemi shoulder arthroplasty is different from new implants. We hypothesized that the surface roughness will increased due the articulation and that metallic wear is detectable on the implants. Twelve retrieved and three brand new hemi shoulder arthroplasty were included. The surface roughness (Ra, Rz, Rmax, Rsk) was measured on different sites of the surface (center of the head and at the edge). The implants were further measured using a coordinate measuring machine to gain information on volumetric wear and geometrical alterations. Compared to new implants the surface roughness on the retrievals was significantly increased (Tab. 1), except for skewness. Although the roughness parameters within the retrieval group were generally higher at the center of the head compared to the edge, this difference was not significant. Apart from form deviations no volumetric wear was detectable on the heads (Fig. 1). The current results indicate that the metallic articular implant surface changes in vivo and that the material is hurt due to the articulation against the softer cartilage or bone. Although it can't be finally clarified by that study, to what extend the higher roughness is taking part in the process of the clinically observed erosion of the gleniod, it can be assumed that an increased roughness is disadvantageous. Possibly, the observed surface alterations won't occur clinically with harder materiel (e.g. ceramic), but this even needs to be validated


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 55 - 55
1 Mar 2013
Laubscher M Banderker E Wieselthaler N Hoffman E
Full Access

Purpose. The outcome of idiopathic chondrolysis in South Africa has been reported as a progressive downhill course resulting in a painful, stiff hip (Jones 1971, Sparks&Dall 1982). The cause of the disease remains unknown. Theories suggested are mechanical (decreased movement with loss of synovial nutrition; increased joint pressure) and an auto-immune response in genetically predisposed individuals. Our experience with continuous passive motion (CPM) and anti-inflammatory treatment has been disappointing. Method. In order to improve our understanding of the disease and our results, we prospectively studied 5 consecutive patients. All the patients had a subtotal capsulectomy (Roy&Crawford 1988) to relieve intra-articular pressure and correction of the flexion and abduction deformities. Post-operative treatment was with anti-inflammatories and CPM. Results. The patients were adolescent females between 10 and 12.5 years old. They presented with stiff, painful hips with flexion, abduction and external rotation deformities. They had normal auto-immune markers. Radiographs revealed osteopenia and joint space narrowing. CT confirmed osteopenia and joint space narrowing. Three patients had subchondral erosions (two on either side of the joint and one on the acetabular side only). MRI showed bone oedema and confirmed the erosions. Histology of the synovium showed non-specific chronic inflammation with lymphocyte and plasma cell infiltration suggesting an auto-immune cause. Histology of the cartilage showed a superficial layer of fibrous tissue, then a layer of degenerate chondrocytes, with normal chondrocytes in the deep layer. Post-operatively patients had improved range of motion. At mean follow up of 7.8 months the patients had a repeat MRI to assess cartilage regeneration. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 1 - 1
1 May 2019
Galatz L
Full Access

The treatment of proximal humerus fractures remains controversial. The literature is full of articles and commentary supporting one method over another. Options include open reduction and internal fixation, hemiarthroplasty, and reverse shoulder arthroplasty. Treatment options in an active 65-year-old are exceptionally controversial given the fact that people in this middle-aged group still wished to remain active and athletic in many circumstances. A hemiarthroplasty offers the advantage of a greater range of motion, however, this has a high incidence of tuberosity malunion or nonunion and this is a very common reason for revision of that hemiarthroplasty for fracture to a reverse shoulder replacement. One recent study showed a 73% incidence of tuberosity malunion or nonunion in shoulders that had a revised hemiarthroplasty to a reverse shoulder replacement. Progressive glenoid wear and erosion is also a risk after a hemiarthroplasty in the younger patient, especially someone who is young and active. In addition, studies show shorter operative time in hemiarthroplasty. The range of motion is highly dependent on proper tuberosity healing and this is often one of the most challenging aspects of the surgical procedure as well as the healing process. A reverse shoulder replacement in general has less range of motion compared to a hemiarthroplasty with anatomically healed tuberosities, however, the revision rate is lower compared to a hemiarthroplasty. (This is likely related to few were options for revision). The results after a reverse shoulder replacement may not be as dependent on tuberosity healing, however, importantly the tuberosities do need to be repaired and the results are significantly better if there is healing of the greater tuberosity, giving some infraspinatus and/or teres minor function to the shoulder. Complete lack of tuberosity healing forces the shoulder into obligate internal rotation with attempted elevation and this can be functionally disabling. Academic discussion is beginning surrounding the use of a reverse shoulder replacement in the setting of glenohumeral joint arthritis in a primary setting as it is believed that the glenosphere and baseplate may have greater longevity than a polyethylene glenoid. Along with this discussion, we will likely see greater application of the use of a reverse shoulder replacement in the setting of fracture for younger patients. In general, open reduction internal fixation should still remain the treatment of choice in the setting of a fracture that can be fixed. However, a strong argument can be made that if an arthroplasty is necessary, a reverse shoulder replacement is the implant of choice


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 78 - 78
1 Aug 2017
Lachiewicz P
Full Access

Uncemented metal-on-polyethylene total hip arthroplasties (THAs) have had a modular cobalt-chrome alloy head since their introduction in the early 1980's. Retrieval analysis studies and case reports in the early 1990's first reported corrosion between the femoral stem trunnion (usually titanium alloy) and cobalt-chrome alloy femoral head. However, then this condition seemed to disappear for about two decades? There are now numerous recent case series of this problem after metal-on-polyethylene THA, with a single taper or dual taper modular femoral component. Metal ion elevation, corrosion debris, and effusion are caused by mechanically assisted crevice corrosion (MACC). These patients present with diffuse hip pain, simulating trochanteric bursitis, iliopsoas tendinitis, or even deep infection. Trunnion corrosion, with adverse local tissue reaction, is a diagnosis of exclusion, after infection, loosening, or fracture. The initial lab tests recommended are: ESR, CRP, and serum cobalt and chromium ions. With a metal-on-polyethylene THA, a cobalt level > 1ppb is abnormal. Plain radiographs are usually negative, but may show calcar osteolysis or acetabular erosion or cyst. MARS MRI may be the best imaging study to confirm the diagnosis. Hip aspiration for culture and cell-count may be necessary. The operative treatment is empiric, with debridement, and head exchange with a ceramic head-titanium sleeve (or oxidised zirconium head) placed on the cleaned trunnion. The femoral component may have to be removed if there is “whole trunnion failure”. This usually relieves the symptoms, but the complication rate of this procedure may be high


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 75 - 75
1 Jun 2018
Lewallen D
Full Access

Even though primary total knee arthroplasty involves resurfacing the joint with metal and plastic it is much more of a soft tissue operation than it is a bony procedure. The idea that altering the planned bony resection by a few degrees on either the tibial or femoral side of the joint might somehow eliminate the multifactorial pain complaints and reduced patient satisfaction seen in some 20% or more of cases in reported clinical series is clearly overly optimistic. Axial alignment is important, but no more so than the level of distal femoral resection, tibial and femoral rotation, tibial resection level and downslope and femoral sagittal plane alignment. The real problem is that errors in component positioning are common, rarely made one at a time, and are made more common by greater procedural complexity. No matter the resection method (let alone the resection target!) errors are commonly linked and iterative. For example: femoral malrotation on an under-resected distal femur (in a knee with minimal arthritic wear to begin with) can contribute to corresponding tibial malrotation helped by a “floated” tibial trial on an all too often overly resected and downsloped tibial surface that has been recut to allow full extension with the under-resected femur (and now also results in AP laxity in flexion). Small changes in the alignment target will not fix this!. On the other hand: Kinematic alignment individualised to the patient's anatomy as a means of reducing soft tissue imbalance and minimizing ligamentous releases is actually a reasonable objective and a laudable goal on the surface. The problem with operationalizing this widely relates to what is currently required to try and reliably achieve this goal using currently available implants and technology. In the early 1980's the proponents of “anatomic” alignment with a residual 2- to 3-degree varus tibial resection and corresponding joint obliquity were Hungerford and Krackow. This concept was widely adopted but proved to be fraught with difficulty in the hands of community based surgeons in that era due to common excessive varus tibial resection errors and resulting premature implant failures. Recent reports on kinematic alignment involve a plethora of technology combinations including pre-operative CT (or MRI) for 3D reconstruction and planning, custom jig fabrication, and navigated bony preparation or individualised bony cuts off of patient specific jigs. The goal is to allow customised resections that “estimate” original cartilage thickness and bone erosion and seek to replicate the original however native anatomy and provide better precision for bone resection. Even when successful this is often followed by placement of a standard implant not too different from those in the 80's and 90's which may well have one femoral articular “J curve” for all patents, a single patellofemoral groove design and anatomic shape for all, and that makes use of a central keel on a nonanatomic tibial design with limited sizing increments, all implanted into a patient without an ACL and not infrequently PCL deficient as well. And all of this is done with the hope of restoring the normal original knee kinematics!. The frequent combination of several of the above factors clinically in a single knee may help explain some of the variability in results of kinematic alignment reported by some authors even after excluding certain pre-operative deformities (excess valgus or varus). For now mechanical alignment methods and instrumentation should remain the standard of care for routine TKA practice for most, and in complex primary cases for all


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2015
Crosby L
Full Access

Before reverse shoulder replacement was an option for rotator cuff tear arthropathy the treatment modalities were limited to injections and physical therapy for pain control, arthroscopic debridement with or without biceps tenodesis/tenotomy and hemiarthroplasty. Functional improvement was limited with these treatment options and success for pain control was moderate at best. The destructive nature of the rotator cuff deficient shoulder continued with medialization of the glenoid and erosion of the acromion seen even after replacement with hemiarthroplasty. The end result usually left the patient with a pseudo paralysis of the shoulder region functionally and uncontrolled pain that made later revision with a reverse implant difficult or impossible. Reverse arthroplasty was released for use in United States in 2004 for rotator cuff tear arthropathy. This initial procedure had a number of related complications that have been improved on over time with changes in implant design and better operative techniques. The long term results with reverse total shoulder arthroplasty have made this the procedure of choice for contained cuff tear arthropathy