Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 62 - 62
4 Apr 2023
Rashid M Islam R Marsden S Trompeter A Teoh K
Full Access

A number of classification systems exist for posterior malleolus fractures of the ankle. The reliability of these classification systems remains unclear. The primary aim of this study was to evaluate the reliability of three commonly utilised fracture classification systems of the posterior malleolus. 60 patients across 2 hospitals sustaining an unstable ankle fracture with a posterior malleolus fragment were identified. All patients underwent radiographs and computed tomography of their injured ankle. 9 surgeons including pre-ST3 level, ST3-8 level, and consultant level applied the Haraguchi, Rammelt, and Mason & Molloy classifications to these patients, at two timepoints, at least 4 weeks apart. The order was randomised between assessments. Inter-rater reliability was assessed using Fleiss’ kappa and 95% confidence intervals (CI). Intra-rater reliability was assessed using Cohen's Kappa and standard error (SE). Inter-rater reliability (Fleiss’ Kappa) was calculated for the Haraguchi classification as 0.522 (95% CI 0.490 – 0.553), for the Rammelt classification as 0.626 (95% CI 0.600 – 0.652), and the Mason & Molloy classification as 0.541 (95% CI 0.514 – 0.569). Intra-rater reliability (Cohen's Kappa) was 0.764 (SE 0.034) for the Haraguchi, 0.763 (SE 0.031) for the Rammelt, 0.688 (SE 0.035) for the Mason & Molloy classification. This study reports the inter-rater and intra-rater reliability for three classification systems for posterior malleolus fractures. Based on definitions by Landis & Koch (1977), inter-rater reliability was rated as ‘moderate’ for the Haraguchi and Mason & Molloy classifications; and ‘substantial’ for the Rammelt classification. Similarly, the intra-rater reliability was rated as ‘substantial’ for all three classifications


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 5 - 5
4 Apr 2023
Vicary-Watts R McLauchlan G
Full Access

Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR). This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score. The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one peri-prosthetic fracture. The mean Oxford score pre-arthroplasty was 12.2 (8.4), improving to 38.4 (11.1) at one-year. Although the pre op Oxford scores tended to be lower in patients with undisplaced fractures and higher ASA scores, the improvement was the same whatever the pre-op situation. The one-year Oxford score and the improvement in score are comparable to those seen in the literature for THR in general. In conclusion, CHS has a high success rate and where salvage arthroplasty is required it can provide good clinical outcomes with low complication rates


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 12 - 12
1 Dec 2021
Samsami S Pätzold R Winkler M Herrmann S Müller PE Chevalier Y Augat P
Full Access

Abstract. Objective. Bi-condylar tibia plateau fractures are one of challenging injuries due to multi-planar fracture lines. The risk of fixation failure is correlated with coronal splits observed in CT images, although established fracture classifications and previous studies disregarded this critical split. This study aimed to experimentally and numerically compare our innovative fracture model (Fracture C), developed based on clinically-observed morphology, with the traditional Horwitz model (Fracture H). Methods. Fractures C and H were realized using six samples of 4th generation tibia Sawbones and fixed with Stryker AxSOS locking plates. Loading was introduced through unilateral knee replacements and distributed 60% medially. Loading was initiated with six static ramps to 250 N and continued with incremental fatigue tests until failure. Corresponding FE models of Fractures C and H were developed in ANSYS using CT scans of Sawbones and CAD data of implants. Loading and boundary conditions similar to experimental situations were applied. All materials were assumed to be homogenous, isotropic, and linear elastic. Von-Mises stresses of implant components were compared between fractures. Results. Fracture C showed 46% lower static stiffness than Fracture H, and it was 38–59% laxer than Fracture H during cyclic loading. Fractures C and H failed at 368±63N and 593±159N, respectively. Von-Mises stress distributions of locking plates indicated that for Fracture C peak stresses, observed around the proximal-inferior and proximal-threadless holes, were 55% higher than Fracture H's, which occurred around the kick-stand hole. The Kick-stand screw of Fracture C demonstrated 65% higher stress than Fracture H's. Conclusions. Experimental outcomes revealed that coronal splits significantly reduced structural stability. Von-Mises stress distributions demonstrated that potential fatigue failure points of implant components depend on the fracture geometry. Therefore, coronal fracture lines should be counted to precisely assess different fixation methods and find the optimum option for this problematic trauma


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 87 - 87
1 Mar 2021
Bommireddy L Crimmins A Gogna R Clark DI
Full Access

Abstract. Objectives. Operative management of distal humerus fractures is challenging. In the past, plates were manually contoured intraoperatively, however this was associated with high rates of fixation failure, nonunion and metalwork removal. Anatomically pre-contoured distal humerus locking plates have since been developed. Owing to the rarity of distal humeral fractures, literature regarding outcomes of anatomically pre-contoured locking plates is lacking and patient numbers are often small. The purpose of this study is to investigate the outcomes of these patients. Methods. We retrospectively identified patients with distal humeral fractures treated at our institution from 2009–2018. Inclusion criteria were patients with a distal humeral fracture, who underwent two-column plate fixation with anatomically pre-contoured locking plates. Clinical records and radiographs were reviewed to elicit outcome measures, including range of motion, complications and reoperation rate. Results. We identified 50 patients with mean age of 55 years (range 17–96 years). Mean length of follow up was 5.2 years. AO fracture classification Type A occurred most frequently (46%), followed by Type B (22%) and Type C (32%). Low energy mechanisms of injury predominated in 72% of patients. Mean time from injury to fixation was seven days. Mean range of motion at the elbow was 13–123o postoperatively. The overall reoperation rate was 22%, the majority of which required subsequent removal of prominent metalwork (18%). The incidence of nonunion, heterotopic ossification, deep infection and neuropathy requiring decompression was 2% each. Fixation failure occurred in only one patient however the fracture went on to heal. Conclusions. Previously reported reoperation rates with manually contoured plates were as high as 44%, which is twice our reported rate. Modern locking plates are no longer subject to implant failure (previously 27% reported metalwork failure rate). Likewise, heterotopic ossification and non-union have also reduced, highlighting that modern plates have significantly improved overall patient outcomes. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 39 - 39
1 May 2012
Ramasamy A Hill AM Gibb I Masouros SD Bull AM Clasper JC
Full Access

Introduction. Civilian fractures have been extensively studied with in an attempt to develop classification systems, which guide optimal fracture management, predict outcome or facilitate communication. More recently, biomechanical analyses have been applied in order to suggest mechanism of injury after the traumatic insult, and predict injuries as a result of a mechanism of injury, with particular application to the field so forensics. However, little work has been carried out on military fractures, and the application of civilian fracture classification systems are fraught with error. Explosive injuries have been sub-divided into primary, secondary and tertiary effects. The aim of this study was to 1. determine which effects of the explosion are responsible for combat casualty extremity bone injury in 2 distinct environments; a) in the open and b) enclosed space (either in vehicle or in cover) 2. determine whether patterns of combat casualty bone injury differed between environments Invariably, this has implications for injury classification and the development of appropriate mitigation strategies. Method. All ED records, case notes, and radiographs of patients admitted to the British military hospital in Afghanistan were reviewed over a 6 month period Apr 08-Sept 08 to identify any fracture caused by an explosive mechanism. Paediatric cases were excluded from the analysis. All radiographs were independently reviewed by a Radiologist, a team of Military Orthopaedic Surgeons and a team of academic Biomechanists, in order to determine the fracture classification and predict the mechanism of injury. Early in the study it became clear that due to the complexity of some of the injuries it was inappropriate to consider bones separately and the term ‘Zone of Insult’ (ZoI) was developed to identify separate areas of injury. Results. 62 combat casualties with 115 ZoIs (mean 1.82 zones) were identified in this study. 34 casualties in the open sustained 56 ZoIs (mean 1.65); 28 casualties in the enclosed group sustained 59 ZoIs (mean 2.10). There was no statistical difference in the mean ZoIs per casualty in the open vs enclosed group (Student t-test, p=0.24). Open fractures were more prevalent in the open group compared to the enclosed group (48/59 vs 20/49, Chi-squared test p<0.001). Of the casualties in the open, 1 zone of injury was due to the primary effects of blast, 10 a combination of primary and secondary blast zones, 23 due to secondary effects and 24 from the tertiary effects of blast. In contrast, there were no primary or combined primary and secondary blast zones and only 2 secondary blast zones in the enclosed group. Tertiary blast effects predominated in the enclosed group, accounting for 96% of injury zones (57/59). Analysis of the pattern of injury revealed that there were a higher proportion of lower limb injuries in the Enclosed group (54/59) compared to the Open group (40/58, Chi-squared p<0.05). In the Open group the mechanism of lower limb injury was more evenly distributed amongst mixed primary and secondary blast effects (10), secondary (10) and tertiary (20). In the enclosed group, lower limb injuries were almost exclusively caused by tertiary blast effects (47/48). A similar pattern was also seen in the Upper limb with 4/5 in the enclosed group was injured by tertiary effects compared to 4/18 in the Open Group. In the open group fragmentation injury was the predominant cause of injury (13/18). Conclusions. This data clearly demonstrates two distinct injury groups based upon the casualties' environment. The enclosed environment afforded by buildings and vehicles appears to mitigate the primary and secondary effects of the explosion. However, tertiary blast effects were the predominant mechanism of injury, with severe axial loading to the lower extremity being a characteristic of the fractures seen. In contrast, secondary fragments from the explosion were more likely to result in fractures of casualties caught in the open. The development of future mitigation strategies must be focused on reducing all the different mechanisms of injury caused by an explosion. This will require a better understanding on the effects of bone in high strain environments. This method of forensic biomechanics involving clinicians and engineers, combined with accurate physical and numerical simulations can form the basis in reducing the injury burden to the combat soldier


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 186 - 186
1 Jul 2014
Falcinelli C Schileo E Balistreri L Baruffaldi F Toni A Albisinni U Ceccarelli F Milandri L Viceconti M Taddei F
Full Access

Summary Statement. In a retrospective study, FE-based bone strength from CT data showed a greater ability than aBMD to discriminate proximal femur fractures versus controls. Introduction. Personalised Finite Element (FE) models from Computed Tomography (CT) data are superior to bone mineral density (BMD) in predicting proximal femoral strength in vitro [Cody, 1999]. However, results similar to BMD were obtained in vivo, in retrospective classification of generic prevalent fractures [Amin, 2011] and in prospective classification of femoral fractures [Orwoll, 2009]. The aim of this work is to test, in a case-control retrospective study, the ability of a different, validated FE modelling procedure [Schileo, 2008] to: (i) discriminate between groups of proximal femoral fractures and controls; (ii) individually classify fractures and controls. Patients & Methods. 55 women (22 incident low-trauma proximal femur fractures and 33 controls) were enrolled in 3 clinical centres in Emilia Romagna region, Italy. All received a full femoral CT and DXA exams (in acute conditions for fractured cases) with a standardised protocol. Femoral neck aBMD was measured from DXA. FE models were built from CT (right femur for controls, intact for fractured) [Schileo, 2008]. Differently from existing works, FE strength was calculated for a range of 12 physiological directions of hip joint reactions [Bergmann, 2001] and 10 fall directions [Grassi, 2012]. Bone strength (in stance and fall) was the minimum load inducing on the femoral neck surface an elastic principal strain value greater than the yield limit [Bayraktar, 2004]. Fracture classification was analysed through logistic regressions and AUC of ROC curves. Results. Mean FE strength and aBMD were significantly lower in the fractured than in the control group (33%, p<0.0001 for strength; 12% p=0.01 for aBMD). Logistic regression on single variables. All classifiers were significant (p<0.001, AUC=0.88 for both stance and fall FE strength, p=0.02, AUC=0.72 for aBMD). The statistical power of the logistic regressions [Vaeth, 2004] was >0.9 for FE strength, 0.86 for aBMD. Logistic regressions on multiple variables. Only FE strength was retained significant (p<0.001, AUC=0.88) when including aBMD in the regression. Adding age to the logistic regression, FE strength and age (but not aBMD) remained significant, with AUC=0.95. Discussion. FE strength could discriminate the fractured group better than aBMD and than [Keyak, 2011]. FE strength was a better fracture classifier than aBMD, and obtained AUC values slightly higher than [Amin, 2011; Orwoll, 2009]. The high statistical power mildens the small sample numerosity. Cases and controls were not age matched, but FE strength and age were found to be independent classifiers. In conclusion the proposed FE method was superior to aBMD in the classification of proximal femoral fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 57 - 57
1 May 2012
Magill P McGarry J Queally J Morris S McElwain J
Full Access

Introduction. Acetabular fractures are a challenging problem. It has been published that outcome is dependent upon the type of fracture, the reduction of the fracture and concomitant injuries. The end-points of poor outcome include avascular necrosis of the femoral head, osteoarthritis. However, we lack definitive statistics and so counselling patients on prognosis could be improved. In order to achieve this, more outcome studies from tertiary referral centres are required. We present the first long term follow up from a large tertiary referral centre in Ireland. Methods. We identified all patients who were ten years following open reduction and internal fixation of an acetbular fracture in our centre. We invited all of these patients to attend the hospital for clinical and radiographic follow-up. As part of this, three scoring systems were completed for each patient; the Short-form 36 health survey (SF36), the Merle d'Aubigné score and the Short Musculoskeletal Functional Assessment (SMFA). Results. The data represents one year's activity at a new tertiary referral unit. We identified a total of 44 patients who were ten years following ORIF of acetabular fractures in our unit. 21 patients (48%) replied to written invitation and attended the hospital for clinical and radiographic follow-up. A further 7 patients were contacted by telephone and interviewed to gauge their rehabilitation. 3 patients had passed away. The remaining 13 patients were not contactable. Of those who attended in person for follow-up; 18 were male and 3 were female. The mean age at follow-up was 40.5 years (Range 27-60). In terms of fracture pattern epidemiology, 43% of patients sustained posterior column and wall fractures, 29% posterior wall, 14% posterior column alone, 9.5% transverse with posterior wall and 9.5% bicolumnar. 2 patients in the follow-up group had total hip replacements. Of the remaining patients the overall mean SF36 score was 78.8% (SD 16.4). The mean SMFA was 14.1% (SD 5). The mean Merle d'Aubigné score was 14.9 (SD 3.2) with 63% graded as good or excellent. Comparison of outcome between sub-groups according to fracture classification showed no significant difference. Traumatic sciatic nerve injury was sustained by four patients in the follow-up group and all patients continued to complain of ongoing weakness. Of the patients who were contacted via telephone, 2 had total hip replacements. The remaining 5 reported no significant problems with their hips and cited this as the reason for not attending follow-up. Conclusion. Overall the outcome of the patients was more favourable than expected. This was supported by the results of the clinical scoring systems. In some patients this also appeared to be despite poor radiographic findings. Our observations suggest that concomitant injuries, especially sciatic nerve injury have a profound negative influence on the patients' ability to fully rehabilitate. These data provide a valuable tool for the trauma surgeon in providing the patient with an educated prognosis


Bone & Joint Research
Vol. 6, Issue 8 | Pages 481 - 488
1 Aug 2017
Caruso G Bonomo M Valpiani G Salvatori G Gildone A Lorusso V Massari L

Objectives

Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years.

Methods

A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.