Within an ageing population, the morbidity and mortality burden of neck of femur fractures will only worsen. Financially incentivising acute Trusts via the Best Practice Tariff for inpatient care has yielded good results(1,2,3,4) but post-discharge care is still variable. Most importantly, restoring patients to their pre-fracture mobility is key to their quality of life(5,6) and reducing both readmissions to hospital(7,8) and expensive local authority residential care. Unfortunately, physiotherapist vacancies are in their thousands(9,10) leading to waiting times of around three months once discharged(11). In 2019, the Royal Derby Hospital created a novel Hip Fracture Patient Advocate (HFPA) to observe those who have fallen through
Aims. Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Methods. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar
Aims. The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Methods. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans. Results. Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar
Hip prosthetic joint infection (PJI) is a debilitating complication following joint replacement surgery, with significant impact on patients and healthcare systems. The INFection ORthopaedic Management: Evidence into Practice (INFORM:EP) study, builds upon the 6-year INFORM programme by developing evidence-based guidelines for the identification and management of hip PJI. A panel of 21 expert stakeholders collaborated to develop best practice guidelines based on evidence from INFORM \[1\]. An expert consensus process was used to refine guidelines using RAND/UCLA criteria. The guidelines were then implemented over a 12-month period through a Learning Collaborative of 24 healthcare professionals from 12 orthopaedic centres in England. Qualitative interviews were conducted with 17 members of the collaborative and findings used to inform the development of an implementation support toolkit. Patient and public involvement contextualised the implementation of the guidelines. The study is registered with the ISCRTN (34710385). The INFORM guidelines, structured around the stages of PJI management, were largely supported by surgeons, although barriers included limited awareness among non-surgical team members, lack of job planning for multidisciplinary teams, and challenges in ensuring timely referrals from primary care. Psychological support for patients was identified as a critical
Aims. Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component?. Methods. A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar
Partial thickness abductor tendon tears are a significant source of recalcitrant laterally based hip pain. For those that fail conservative treatment, the results of endoscopic repair are highly successful with minimal morbidity. The principal burden is the protracted rehabilitation that is necessary as part of the recovery process. There is a wide
This meta analysis address the relationship between infection developing after total hip arthroplasty (THA) and heterotopic ossification (HO). To identify the
The growth of life expectancy during the last decades has led to an increment in age-related conditions such as hip arthritis and fractures. On the other hand, these elderly patients will present a higher incidence of mental diseases which, in some studies, have been associated with inferior results. This study aims to evaluate the differences in early complication rates between patients with cognitive impairment compared with those without this condition following total hip replacement for osteoarthritis or fracture in the context of contemporary perioperative care protocols. We conducted a retrospective cohort study where cognitively-impaired patients who required primary hip arthroplasty were compared to a propensity-score matched cohort of patients without cognitive alterations. Early major complications were measured and analyzed in order to determine significant differences. Screening and matching. 1196 patients were identified during the study period. After screening for inclusion and exclusion criteria and matching, two cohorts comprising 65 patients each were compared. After performing the propensity-score match, no significant differences were found in covariates between the two groups. Outcomes. The occurrence of delirium was more frequent in patients with cognitive deficit (27.5%) than in the control group (9%), p<0.001. No significant differences were found among groups regarding myocardial infarction, venous thromboembolism, blood transfusion requirement, 30-day readmission, in-hospital death, 90-days death, dislocation or surgical site infection. The composite outcome of any adverse event did not exhibit a significant difference either. To our knowledge, this is the first study which demonstrates similar outcomes between patients with cognitive impairment and those without these alterations. Our results might indicate that contemporary protocols and implants are bridging the traditional
The purpose of this modified Delphi study was to obtain consensus on wound closure (including best practices for each tissue layer of closure) and dressing management in total hip arthroplasty (THA), using an evidence-based approach. The Delphi panel included 20 orthopedic surgeons from Europe and North America. Eighteen statements were identified (14 specific to THA and 4 relating to both THA and total knee arthroplasty) using a targeted literature review. Consensus was developed on the statements with up to three rounds of anonymous voting per topic. Panelists ranked their agreement with each statement on a five-point Likert scale. An a priori threshold of 75% was required for consensus. In Round 1, 15 of 18 statements achieved consensus via a structured electronic questionnaire. In Round 2, the 3 statements that did not achieve consensus were revised during a virtual face to face meeting. An additional 2 statements were edited for clarity. In Round 3, the 5 revised statements achieved consensus via a structured electronic questionnaire. Wound closure related interventions that were recommended for use in THA included: 1) barbed sutures over non-barbed sutures (shorter closing times and overall cost savings); 2) subcuticular sutures over skin staples (lower risk of infections and higher patient preference); 3) mesh-adhesives over silver-impregnated dressings (lower rate of wound complications); 4) negative pressure wound therapy over other dressings (lower wound complications and reoperations and fewer dressing changes); 5) triclosan coated sutures (lower risk of surgical site infection). Using a modified Delphi approach, a panel of 20 orthopedic surgeons achieved consensus on 18 statements pertaining to multi-layer wound closure and dressing management in THA. This study forms the basis for identifying critical evidence
Aims. Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable
The 2020 London International Hamstring Consensus meeting was convened to improve our understanding and treatment of hamstring injuries. The multidisciplinary consensus panel included 14 International specialists on the management of hamstring injuries. The Delphi consensus process consisted of two rounds of surveys which were completed by 19 surgeons from a total of 106 participants. Consensus on individual statements was regarded as over 70% agreement between panel members. The consensus group agreed that the indications for operative intervention included the following:
Introduction. The anatomic dual mobility (ADM) technology utilized a monoblock cobalt chromium acetabular component. However, design limitations conferred difficulties controlling orientation during component insertion and inability to confirm full implant seating; the solution resulted in the creation of the modular dual mobility (MDM). The modular implant combines a standard titanium acetabular component and a cobalt chromium liner insert. Due to the metal-on-metal interface on MDM implants, fretting and corrosion releasing metal ions like previous metal-on-metal THA implants, were a concern. This study prospectively reviewed metal ions (cobalt, chromium and titanium) on patients who were at least 1 year post MDM implantation and compared them to patients with an ADM implant and evaluated radiographic seating of the components. Methods. All patients with ADM and MDM implants underwent evaluation of metal ions (cobalt, chromium and titanium) at their one year follow-up appointment. Radiographic evaluation for acetabular polar
Introduction. Porous coated cups have a low modulus of elasticity that enhances press-fit and a surface that promotes osseointegration as well as permitting modularity. Monoblock ceramic acetabular cups represent a subtype of uncemented cup permitting the use of large femoral heads. The aim of this study was to compare the short-term clinical and radiographic performances of both cups. Methods. This was a prospective RCT of 86 unilateral THA patients (M: 40, F: 48; mean age: 59.5 ± 10.6) randomized to either a porous-coated, modular metal-on-polyethylene (MoP) acetabular component (pore size 250µm, 45% mean volume porosity)(n=46) or a hydroxyapatite (HA) and titanium-coated monoblock shell with ceramic-on-ceramic(CoC) bearing (pore size 300µm, 48% mean volume porosity & 80nm HA coating thickness)(n=42). All sockets were under-reamed by 1 mm. Two-year radiographs and patient-reported outcomes (PROMs) were available. Results. Thirty-two (69%) and 28 (6%)
Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a
Objectives. Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. Materials and Methods. A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm. 3. (standard deviation (. sd). 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and
Porous tantalum is a highly osteoinductive biomaterial, initially introduced in orthopedics in 1997, with a subsequent rapid evolution of orthopedic applications. The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and mid-term results. However, long term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiological outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients. We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. The presence of initial
To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure.Aims
Methods
Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up. This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up.Aims
Methods
Introduction. The vast majority of intertrochanteric fractures treated with cephalomedullary nails (CMN) will heal. Occasionally even though bony union occurs excessive lag screw sliding can cause persistent pain and soft tissue irritation and return to surgery for hardware removal. The purpose of this study was to evaluate if fracture stability, lag screw tip-apex distance (TAD), and quality of reduction have any impact excessive lag screw sliding and potential cutout. Methods. As part of our level one trauma center's institutional hip fracture registry, a retrospective analysis identified 199 intertrochanteric fractures fixed with CMN between 2009 and 2015 with follow up to union or a minimum of three months. The mean follow-up was 22 months (3 to 94 months). Mean patient age was 75 years (50 to 97 years) and 72% were women. Postoperative radiographs were used to measure the TAD, quality of reduction, neck-shaft angle (NSA), and lateral lag screw prominence. Follow-up radiographs were reviewed to assess fracture union, translation, and progression of lateral lag screw prominence. Complications and reoperations were recorded. Results. The average lag screw sliding was 5±5 mm. Excessive lag screw sliding (defined as > 10 mm; one standard deviation above the mean) was present in 12% of patients. Lag screw sliding was more common in unstable fracture patterns (21% vs. 5%, p<0.01) and patients with calcar fracture
Periprosthetic hip-joint infection is a multifaceted and highly detrimental outcome for patients and clinicians. The incidence of prosthetic joint infection reported within two years of primary hip arthroplasty ranges from 0.8% to 2.1%. Costs of treatment are over five-times greater in people with periprosthetic hip joint infection than in those with no infection. Currently, there are no national evidence-based guidelines for treatment and management of this condition to guide clinical practice or to inform clinical study design. The aim of this study is to develop guidelines based on evidence from the six-year INFection and ORthopaedic Management (INFORM) research programme. We used a consensus process consisting of an evidence review to generate items for the guidelines and online consensus questionnaire and virtual face-to-face consensus meeting to draft the guidelines.Aims
Methods