Aims. The aims of this study were to report the outcomes of patients with a complex fracture of the lower limb in the five years after they took part in the Wound
Since osteoimmunology is gaining increasingly interest and evidence for involvement of complement in bone biology was found, the role of complement in bone biology and fracture healing was evaluated. After characterizing the bone phenotype, a fracture healing experiment with C3- and C5- deficient mice was performed. After osteotomy of the right femur and external fixation, healing was analyzed after 1, 3, 7 and 21 days. Bone characterization revealed a reduced number of osteoclasts in C5-deficient animals with a significantly reduced resorption activity. While bone mineral density was significantly higher in complement-deficient strains, stiffness was significantly reduced. After 21 days of fracture healing, C5-deficient animals showed reduced stiffness and a smaller callus volume compared to controls. Interestingly, C3- more than C5-deficient animals showed reduced bone formation. Altogether, bone phenotype of complement-deficient animals resembles a mild form of osteopetrosis. This might be due to the resorption defect seen in C5-deficient mice. A reason for the minor involvement of C3-deficient mice compared to the C5-deficient animals could be the cross-talk between the coagulation cascade with side activation of complement factor C5 by thrombin. These results indicate for the first time an essential role of complement in bone biology and fracture healing. Future studies should focus on the molecular basis of complement involvement and the osteoclastic resorption defect.
The aim of this double-blind prospective randomised controlled
trial was to assess whether low intensity pulsed ultrasound (LIPUS)
accelerated or enhanced the rate of bone healing in adult patients
undergoing distraction osteogenesis. A total of 62 adult patients undergoing limb lengthening or bone
transport by distraction osteogenesis were randomised to treatment
with either an active (n = 32) or a placebo (n = 30) ultrasound
device. A standardised corticotomy was performed in the proximal
tibial metaphysis and a circular Ilizarov frame was used in all
patients. The rate of distraction was also standardised. The primary
outcome measure was the time to removal of the frame after adjusting
for the length of distraction in days/cm for both the per protocol
(PP) and the intention-to-treat (ITT) groups. The assessor was blinded
to the form of treatment. A secondary outcome was to identify covariates affecting
the time to removal of the frame.Aims
Patients and Methods
The fracture healing outcome is often evaluated via ex vivo testing of the fracture callus. However, there is only a small time window, where the callus stiffness is significantly different, i.e. a delayed fracture healing might be undetected if the time point of sacrifice is improper. The aim of this study was to develop an in vivo monitoring concept, which allows determining the fracture callus stiffness in vivo over the whole healing time in rats. The fracture callus stiffness can be monitored by measuring the deformation of the external fixation device during gait analysis at several healing time points.Introduction
Hypothesis
Several low energy osteotomy techniques are described in the literature but there is limited evidence comparing healing indices. We present a retrospective review of two techniques to evaluate an optimum method. Two cohorts of patients underwent osteotomy of the tibia using a Gigli saw (n=15) or DeBastiani corticotomy (n=12) technique. Indications for surgery included limb lengthening and bone transport for defect reconstruction with a minimal distraction of 2 cm. The patient radiographs were anonymised and the regenerate assessed by the two senior authors who were blinded to the osteotomy type. Bone quality was recorded along the anterior, posterior, medial and lateral cortices, graded 1–5 from absent to full consolidation over time in frame. The time to 3 cortices healed/regenerate length was calculated. The time to consolidation of the anterior, posterior, medial and lateral cortices were compared. The mean 3 cortices index in the Gigli group was 2.0 months/cm and in the DeBastiani group 1.8 months/cm, This was not a significant difference. In both groups anterior bone formation was slower, and in 50% and 33% of the Gigli and DeBastiani groups respectively the anterior cortex did not fully heal by the time of frame removal.Method:
Results:
Segmental defects of long bones are notoriously demanding and difficult to treat. We evaluate nine cases where the Masquelet induced membrane technique to substitute bone loss has been used. We discuss the method compared to other types of bone reconstruction and share our tips and tricks to reduce treatment time and improve patient comfort. Eight patients (nine injuries) operated between 2011 and 2014 were included. Four were infected. Outcome was time-to weight-bearing, consolidation, complications, bone grafting.Background:
Method:
A multicenter retrospective analysis of patients treated for tibial fracture was conducted to develop a score that correlates with fracture healing time and, ultimately, to identify the risk gradient of delayed healing. The clinical records of 93 patients treated for tibial fracture at three orthopaedic centers were evaluated. Patients were considered healed when full weight bearing was allowed and no further controls were scheduled. For the purpose of our analysis, we separated patients healed within or after 180 days. Patient's risk factors known to be associated to delay healing, as well as fracture morphology and orthopaedic treatment were recorded in an electronic Case Report Form (e-CRF). Information available in the literature was used to weight the relative risk (RR) associated to each risk factor; values were combined to calculate a score to be correlated to the fracture healing time: L-ARRCO (Literature-Algoritmo Rischio Ritardo Consolidazione Ossea). Among all information collected in e-CRFs, we identified other risk factors, associated to delayed healing, that were used to calculate a new score: ARRCO. Univariate logistic analysis was used to determine a correlation between the score and healing time. Analysis by receiver operating characteristic (ROC) and calculation of the area under the curve (AUC) were used for sensitivity and specificity. Complete information was available for 53 patients. The mean value of the L-ARRCO score among patients healed within 180 days was 5.78 ± 1.59 and 7.05 ± 2.46 among those healed afterwards, p=0.044. The mean value of the ARRCO score of patients healed within 180 days was 5.92 ± 1.78 and 9.03 ± 2.79 among those healed afterwards, p<0.0001. The ROC curve shows an AUC of 0.62±0.09 for L-ARRCO and an AUC of 0.82±0.07 for ARRCO, (p<0.0001). We have shown that the ARRCO score value is significantly correlated to fracture healing time. The score may be used to identify fractures at risk of delayed healing, thus allowing surgeon's early intervention to stimulate osteogenesis.
We evaluated the osteogenic potential of a novel biomimetic bone paste (DBSint®), made of a combination of a human demineralized bone matrix (hDBM) and a nano-structured magnesium-enriched hydroxyapatite (Mg-HA), in a standardized clinical model of high tibial osteotomy for genu varus. A prospective, randomized, controlled study was performed and thirty patients were enrolled and assigned to three groups: DBSint® (Group I), nano-structured Mg-HA (SINTlife®) (Group II) and lyophilized-bone-chips (Group III). Six weeks after surgery, computed tomography-guided biopsies of the grafts were performed. Clinical/radiographic evaluation was performed at six weeks, twelve weeks, six months, one and 2 year after surgery, in order to verify if the graft type influenced the healing rate.Introduction
Methods
Our unit has extensive experience with the use of Ilizarov circular frames for acute fracture and nonunion surgery. We have observed and analysed fracture healing patterns which question the role of relative stability in fracture healing and we offer limb mechanical axis restoration as a more important determinant. To assess for the presence of external callus, when only relative stability has been achieved but with anatomical restoration of the mechanical axis (ARMA).Introduction
Aim
The hematoma occurring at a fracture site is known to play an important role in fracture healing. Previously, we demonstrated that fracture hematoma contained multilineage mesenchymal progenitor cells. On the other hand, the process of fracture healing is associated by two different mechanisms, intramembranous and endochondral. However, there are no reports proving the details about cellular analysis in the process of endochondoral ossification. We hypothesized that one of the cell origins for endochondral ossification after fracture was hematoma.Introduction
Hypothesis
There is evidence that fracture healing is impaired in patients with chronic immune disorders the reasons remaining unclear so far. To further elucidate the role of the immune system in bone healing, this study investigated the hypothesis that fracture healing would be considerably disturbed in a mouse model with severe defects of the innate as well as adaptive immune system. Immune deficient Nod- The flexural rigidity of the callus did not significantly differ between both genotypes after 21 and 28 days but was significantly lower in Nod- These data indicate an only moderate delay in fracture healing in Nod-
CXC chemokine receptor 4 (CXCR4) is a specific receptor for stromal-derived-factor 1 (SDF-1). SDF-1/CXCR4 interaction contributes to the regulation of endotherial progenitor cell (EPC) recruitment in ischemic tissues. The purpose of this study is to investigate the mechanistic function of CXCR4 on EPCs for bone fracture healing. We made CXCR4 gene knockout mice using the Cre/loxP system. A reproducible model of femoral fracture was created in both Tie2-Cre CXCR4 knockout mice (CXCR4KO) and wild type mice (control). To evaluate gain function of the SDF-1/CXCR4 pathway, we set three groups of the SDF-1 intraperitoneally injected group, wild type group, and SDF-1 injected CXCR4 KO group.Introduction
Materials and methods
In the assessment of fracture healing by monitoring stiffness with vibrational analysis or instrumented external fixators, it has been assumed that there is a workable correlation between stiffness and strength. We used four-point bending tests to study time-related changes in stiffness and strength in healing tibial fractures in sheep. We aimed to test the validity of the measurement of stiffness to assess fracture strength. At each duration of healing examined, we found marked variations in stiffness and strength. Stiffness was shown to be load-dependent: measurements at higher loads reflected ultimate strength more accurately. There was a biphasic relationship between stiffness and strength: at first there was a strong correlation regardless of loading conditions, but in the second phase, which included the period of ‘clinical healing’, stiffness and strength were not significantly correlated. We conclude that the monitoring of stiffness is useful primarily in assessing progress towards union but is inherently limited as an assessment of strength at the time of clinical union. Any interpretation of stiffness must take into account the load conditions.
Despite its clinical significance, metaphyseal fracture healing has received little attention in research and experimental models have been limited. In particular it is not known to what extent the mechanical environment plays a role in metaphyseal fracture healing. Recently, a new murine internal fixation plate has been developed to stabilise fractures in the distal femur under highly standardised conditions. Goal of the current study was to modify this design, in order to be able to evaluate the influence of the fixator bending stiffness on metaphyseal fracture healing in mice. Adapting the existing single body design, resulting in low flexibility fixation, two new plates were developed with a decreased bending stiffness of approximately 65% and 45% of the original implant (100%). Pilot experiments were performed on 54 animals, whereas the mice were sacrificed and fracture healing assessed radiologically and biomechanically after 14 and 28 days. MicroCT evaluation confirmed that the osteotomy was created in the trabecular, metaphyseal bone of the distal mouse femora. All bones showed progressive fracture healing over time, with decreased implant stiffness leading to increased periosteal callus formation. These implants represent an important new research tool to study molecular and genetic aspects of metaphyseal fracture healing in mice under standardized mechanical conditions, in order to improve clinical treatment in challenging situations, such as in osteoporotic bone.
Secondary fracture healing processes are strongly influenced by interfragmentary motion. Shear movement is assumed to be more critical than axial movement, however experimental results are controversial. Numerical fracture healing models allow to simulate the fracture healing process with variation of single input parameters and under comparable normalized mechanical conditions. Therefore, a direct comparison of different in vivo scenarios is possible. The aim of this study was to simulate fracture healing under several axial and shear movement scenarios and compare their respective time to heal. We hypothesize that shear movement is always more critical than axial loading. For the presented study, we used a corroborated numerical model for fracture healing in sheep. Numerous variations of the movement amplitude, the fracture gap size and the musculoskeletal loads were simulated for comparable axial compressive and shear load cases. In all simulated cases, axial compressive load had less inhibitory influences on the healing process than shear load. Therefore, shear loading is more critical for the fracture healing outcome in general. Thus, our findings suggest osteosynthesis implants to be optimized to limit shear movements under musculoskeletal loading.
The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Echo tracking (ET) can noninvasively measure the displacement of a certain point on the bone surface under a load. Echo tracking has been used to assess the bone deformation angle of the fracture healing site. Although this method can be used to evaluate bending stiffness, previous studies have not validated the accuracy of bending stiffness. The purpose of the present study is to ensure the accuracy of bending stiffness as measured by ET. A four-point bending test of the gap-healing model in rabbit tibiae was performed to measure bending stiffness. Echo tracking probes were used to measure stiffness, and the results were compared with results of stiffness measurements performed using laser displacement gauges. The relationship between the stiffness measured by these two devices was completely linear, indicating that the ET method could precisely measure bone stiffness.
Nowadays, autologous platelet-rich plasma is used commonly in wound treatment. However, platelet gel, which was derived from allogeneic platelet-rich plasma (PRP) [1,2], has never been studied about efficacy in vivo or animal models. We aimed to determine efficacy of allogeneic platelet-gel on wound healing in rats by comparing with untreated, antibiotic-gel (Mupirocin 2%) treated and gel (sodium carboxymethylcellulose(NaCMC))-treated control. Fresh frozen plasma was centrifuged at 1200-G for 15 minutes to extract PRP which would be freeze-dried at −70°c, sterilized with gamma ray of Cobalt source 25 kGy and stored at −70°c. Then, processed freeze-dried PRP was mixed with gel base (NaCMC) as in form of allogeneic platelet-gel concentrated 30 mg/1g by sterilization process (table 1). Full-thickness of 6-mm-diameter skin punch biopsies were performed on 18 female Wistar rats which each rat had four wounds at back. Each wound was applied with untreated care, antibiotic-gel, NaCMC-gel and platelet-gel, respectively. Wound healing was studied from day 0–12. Animals were sacrificed with wound tissues removal on day 3, 7, 12 post-biopsy. Digital planimetric measurement device (VISITRAK, Smith and Nephew) was used in evaluation of total wound area on day 0, 3, 7, 12 post-biopsy. Histopathological changes of wound healing were studied, using 4-μm thickness section with haematoxylin-eosin (H&E) and Masson's trichrome-stain, under light microscope.Introduction
Methods
The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Many researchers have attempted to monitor stiffness either directly or indirectly for the purpose of assessing strength, as strength has been impossible to assess directly in clinical practice. The purpose of this study was thus to determine the relationship between bending stiffness and strength using mechanical testing at different times during the healing process. Unilateral, transverse, mid-tibial osteotomies with a 2-mm gap were performed in 28 rabbits. The osteotomy site was stabilized using a double-bar external fixator. The animals were divided into four groups (n=7/group/time point; 4, 6, 8 and 12 weeks). A series of images from micro-computed tomography of the gap was evaluated to detect the stage of fracture healing and a 4-point bending test was performed to measure stiffness and strength. Formation of cortex and medullary canal at the gap was seen in the 12-week group and would represent the remodeling stage. In addition, the relationship between stiffness and strength remained almost linear until at least 12 weeks. However, stiffness recovered much more rapidly than strength. Strength was not fully restored until the later stages of fracture healing. However, the current study demonstrated that stiffness could be monitored as a surrogate marker of strength until at least the remodeling stage.
Nonunion is a common and costly fracture outcome. Intricate reciprocity between angiogenesis and osteogenesis means vascular cell-based therapy offers a novel approach to stimulating bone regeneration. The current study compared early and late outgrowth endothelial progenitor cell subtypes (EPCs vs OECs) for fracture healing potential in vitro and in vivo.Introduction
Hypothesis
There is evidence that fracture healing is delayed in severely injured patients. We recently demonstrated that a blunt chest trauma, which induced posttraumatic systemic inflammation, considerably impaired fracture healing in rats. Because the complement anaphylatoxin C5a is an important trigger of systemic inflammation, we tested the hypothesis, whether the impairment of fracture healing observed after a severe trauma resulted from systemically activated complement. 16 male Wistar rats received a thoracic trauma and a femur osteotomy stabilized by an external fixator. Immediately and 12 h after the trauma, half of the animals received a C5aR-antagonist to prevent the C5a-dependent systemic inflammation. Control rats received a nonsense peptide, which does not provoke any biological effect. The animals were killed after 35 days and the calli were analyzed by three point bending testing, μCT and histomorphometry. Statistics: Mann-Whitney U test, level of significance to p<0.05. The treatment with the C5aR-antagonist increased flexural rigidity significantly by 55%, improved bony bridging of the fracture gap and led to a slightly larger and qualitatively improved callus as evaluated by μCT and histological measurements. This study shows, that the immunomodulation by a C5aR-antagonist significantly reduced the deleterious effects of a thoracic trauma on fracture healing. C5a could possibly represent a target to prevent delayed bone healing in patients with severe trauma.