Introduction. Infection is disastrous in arthroplasty surgery and requires multidisciplinary treatment and debilitating revision surgery. Between 80-90% of bacterial wound contaminants originate from colony forming units (CFUs) present in operating room air, originating from bacteria shed by personnel present in the operating environment. Steps to reduce bacterial shedding should reduce wound contamination. These steps include the use of unidirectional laminar airflow systems and the introduction of theatre attire modelled on this principle (e.g. total body exhaust suits). Our unit introduced the use of the Stryker Sterishield Personal Protection System
Introduction Infection is a disastrous complication of arthroplasty surgery, requiring multidisciplinary treatment and debilitating revision surgery. As between 80–90% of bacterial wound contaminants originate from colony forming units (CFU’s) present in operating room air tending to originate from bacteria shed by personnel present within the operating environment, any steps that can reduce this bacterial shedding should reduce the chances of wound contamination. These steps have included the use of unidirectional downward laminar airflow theatre systems, and the introduction of theatre attire modelled on this principle (e.g. total body exhaust suits). Our unit has introduced the use of the Stryker T4 Personal Protection System
Introduction Infection is a disastrous complication of arthroplasty surgery, requiring multidisciplinary treatment and debilitating revision surgery. As between 80–90% of bacterial wound contaminants originate from colony forming units (CFU’s) present in operating room air tending to originate from bacteria shed by personnel present within the operating environment, any steps that can reduce this bacterial shedding should reduce the chances of wound contamination. These steps have included the use of unidirectional downward laminar airflow theatre systems, and the introduction of theatre attire modelled on this principle (e.g. total body exhaust suits). Our unit has introduced the use of the Stryker Sterishield Personal Protection System
Background. Sterile Surgical
Introduction. Surgical spacesuits are in widespread use. Only one previous study (JBJS 1998) has assessed the quality of the environment within the space suit. They demonstrated that surgical spacesuits could allow re-breathing of carbon dioxide (CO. 2. ). However, they had no control group and performed a vigorous exercise protocol which may have been an unfair test. The design of
Deep infection occurs in 2–4% of lower limb arthroplasty resulting in increasing cost, co-morbidity and challenging revision arthroplasty surgery. Identifying the potential sources of infection helps reduce infection rates. The aim of our study is to identify the impact and potential for contamination of our hands and gowns whilst scrubbing using SSHS. A colony-forming unit (CFU) is a pathogenic particle of 0.5 micrometers to 5 micrometers. Concurrent particle counts and blood agar exposure settle plates for 3 subjects and 1 alcohol cleaned mannequin; testing a standard arthroplasty hood, a SSHS with and without the fan on for a 2 minute exposure to represent scrubbing time. Microbiological plates were incubated using a standard protocol by our local microbiology department. All SSHS were positive for gram-positive cocci with a mean colony count of 410cfu/m2. Comparing background counts for laminar flow (mean 0.7 particle/m3; 95% CI 0–1.4) versus scrub areas (mean 131.5 particle/m3; 95% CI 123.5–137.9; p=0.0003), however neither grew any CFU's with a 2-minute exposure. For the mannequin, the only significant result was with the fan on with a 1.5× increase in the particle count (p=0.042) and a correlating positive organism (13CFU/m2). With human subjects, however, the particle count increased by 3.75× the background count with the fan on (total p=0.004, CFU p=0.047) and all had positive cultures, mean 36 CFU/m2. There were no positive cultures with the standard arthroplasty hood or the SSHS with no fan on. If repeated in laminar flow, there was only a statistically significant increase with the fan on (p=0.049), but with negative cultures following a 2-minute exposure. Sterile gloves and gowns can be contaminated when scrubbing with the SSHS fan on. We recommend having the fan switched off when scrubbing until the hood and gown is in place, ideally in a laminar flow environment.
Aims. Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters. Methods. We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using t-tests and p-values < 0.05 were considered significant. Results. We studied 5,705 patients from 34 studies. The mean age was 33.3 years (SD 3.5), and 58.3% (n = 3,325) were male. The leading mechanism of injury was falling (n = 3,595, 74.4%). Injured patients were more likely to not wear a
The February 2024 Research Roundup. 360. looks at: If you use a surgical
The December 2024 Shoulder & Elbow Roundup. 360. looks at: Predicting recurrence of instability after a primary traumatic anterior shoulder dislocation; Predictors of surgery and long-term outcomes in nonoperative management of full-thickness rotator cuff tears; Reverse shoulder arthroplasty viable despite acquired acromial compromise, but higher infection risk noted; LP-PRP reduces retear rates in rotator cuff repair but shows no functional outcome advantage; Long-term clinical outcomes of arthroscopic supraspinatus tendon repair using the single anchor tension band technique – minimum five-year follow-up; Arthroscopic stabilization for anterior shoulder dislocation shows low recurrence rates regardless of prior dislocations; ORIF outperforms arthroplasty for complex radial head fractures: mid-term outcomes; Routine use of surgical
Aims. The aim of this study was to identify risk factors for prosthetic
joint infection (PJI) following total knee arthroplasty (TKA). . Patients and Methods. The New Zealand Joint Registry database was analysed, using revision
surgery for PJI at six and 12 months after surgery as primary outcome
measures. Statistical associations between revision for infection,
with common and definable surgical and patient factors were tested. Results. A total of 64 566 primary TKAs have been recorded on the registry
between 1999 and 2012 with minimum follow-up of 12 months. Multivariate
analysis showed statistically significant associations with revision
for PJI between male gender (odds ratio (OR) 1.85, 95% confidence
interval (CI) 1.24 to 2.74), previous surgery (osteotomy (OR 2.45
95% CI 1.2 to 5.03), ligament reconstruction (OR 1.85, 95% CI 0.68
to 5.00)), the use of laminar flow (OR 1.6, 95% CI 1.04 to 2.47)
and the use of antibiotic-laden cement (OR 1.93, 95% CI 1.19 to
3.13). There was a trend towards significance (p = 0.052) with the
use of surgical
Orthopaedic surgical hoods rely on an intrinsic fan to force clean external air over the wearer and allow potentially contaminated and expired air to flow down and away from the surgical field. Carbon dioxide (CO. 2. ) is produced through aerobic metabolism and can potentially accumulate inside the hood. Levels above 2500ppm have been shown to affect cognitive and practical function in flight simulator studies. Maximum Health and Safety Executive (HSE) 8-hour exposure limit is 5000ppm There is a paucity of data on real-world CO. 2. levels experienced during arthroplasty surgery whilst wearing a hood. CO. 2. levels were continuously recorded during 31 elective arthroplasties, both primary and revision. Data was collected for surgeon and assistant. Data was recorded at 0.5Hz throughout the procedure utilising a Bluetooth CO. 2. detector, worn inside a Stryker Flyte. ™. surgical
Trauma patients present with different injuries and some of them require emergency surgical procedures. Orthopaedic department at Steve Biko Academic Hospital (SBAH) have seen an increasing number of patients presenting with serious orthopaedic injuries due to Delivery Motorbike Accidents (DMBA). The aim of the study was to establish the epidemiology and pattern of orthopaedic injuries sustained following Delivery Motorbike Accident. Motor Vehicle Accident (MVA) administration office at SBAH in emergency department was approached for patients registers used between 1 January 2020 and 31 December 2022. There patients were registered as Motor Vehicle Accident (MVA), Motorbike Accident (MBA) and Pedestrian Vehicle Accident (PVA) by the administration office. The details of patients classified as MBA were collected and used to obtain clinical data from medical and radiological records in the form of patient's files and PACS respectively. Approximately 240 patients presented to Emergency department with orthopaedic injuries following a motorbike accident. About 78 files could not be retrieved from the patient's records department. About 74patients had their occupation recorded as unknown or unemployed. Approximately 70 patients had their occupation indicated in the file by the Clinicians or Administration Clerks. About 40 patients had their occupation as delivery man or working for a delivery company. 16 patients did not have images on the PACS system. Most of the patients were males, presented after hours and sustained multiple injuries that were managed surgically. Very few patients had their
The use of exhaust suit systems is commonplace in arthroplasty surgery where isolation of the surgical team is desirable in an attempt to reduce the risk of infection transmission. Elevated carbon dioxide levels have been reported in the non-clinical setting with such systems the consequences of which can include fatigue, diapho-resis, nausea, headache and irritability. The aim of our study was to determine the levels of carbon dioxide present within an exhaust suit system during hip arthroplasty and to compare these with the recommended occupational exposure limit levels published by the Health and Safety Executive (HSE). Data was collected during ten primary hip replacements performed by the same surgeon whilst wearing the Stryker Steri-Shield
The use of exhaust suit systems is commonplace in arthroplasty surgery where isolation of the surgical team is desirable in an attempt to reduce the risk of infection transmission. Elevated carbon dioxide levels have been reported in the non-clinical setting with such systems the consequences of which can include fatigue, diaphoresis, nausea, headache and irritability. The aim of our study was to determine the levels of carbon dioxide present within an exhaust suit system during hip arthroplasty and to compare these with the recommended occupational exposure limit levels published by the Health and Safety Executive (HSE). Data was collected during ten primary hip replacements performed by the same surgeon whilst wearing the Stryker Steri-Shield
The number of skate related injuries has seen a resurgence in the western world with almost 51000 patients in 1999 presenting to US hospitals with a skateboard related injury, almost 90% of these being male and almost 70% of these are orthopaedic related injuries. Protection , particularly wrist guards, elbow pads, knee pads and recognized
Introduction. The original Charnley-type negative pressure body exhaust suit reduced infection rates in randomized trials of total joint arthroplasty decades ago. Modern positive pressure surgical
Surfing is a popular UK water-sport. Recommendations for protective gear are based on studies abroad from trauma from large waves and reef breaks which may not be relevant in the UK. This study assesses the aetiology of UK surfing injuries in order to assist treatment and provide formative recommendations on protective equipment. Data was collected from UK surf clubs via an online survey. 130 individuals reported 335 injuries. M:F ratio 85:45, median age 28 (range 17–65). Head injuries were the most common (24%) followed by foot and ankle (19%). Surfers collided most often with their own boards (31%) followed by rocks/coral (15%), the sea (11%) and other surf boards (10%). Lacerations were the commonest injury (31%); followed by bruises/ black-eyes (24%) and joint/ligament sprains (15%). Concussions (5%), fractures (3%) and teeth injuries (1%) were rare. Less than 1/3 of all injuries required professional medical attention, 2 required operative intervention. Surfing injuries in the UK are common but usually minor. Serious head injuries (fractures and concussions) are rare. There is insufficient evidence to warrant the routine use of protective
Sledging related minor and major injuries represent a significant workload at ski-area medical centers across the world. Although safety rules exist, they are seldom obeyed or enforced. We set out to determine the incidence of sledging related injuries, identifying trends and causative factors at a busy New Zealand Ski resort. All sledging related injuries presenting during a 70-day period were prospectively reviewed. Patient demographics, mechanism, diagnosis, and treatment were recorded. Sixty patients were identified, mean age 10 years, range 4-30 years. Injuries comprised; collisions with sledgers (21), collision with wall (14) and falling from sledge (14). Site of injury included head (36), lower limb (18), spine (9), upper limb (7), and abdomen (2). Fractures included; femur (1), tibia (1), fibula (1), ankle (2), cuboid (1), clavicle (2), scaphoid (1). One 9-year-old patient sustained a serious intracranial haemorrhage, with subsequent permanent neurological sequelae. Sledging related injuries are mostly minor, however significant major injuries do occur requiring intervention at a secondary center. The potential for serious morbidity is evident. Recommendations supporting safety improvement measures does exist, however most were not implemented by the study cohort examined. The use of basic cycling