The aims of this study were to develop an automatic system capable of calculating four radiological measurements used in the diagnosis and monitoring of cerebral palsy (CP)-related hip disease, and to demonstrate that these measurements are sufficiently accurate to be used in clinical practice. We developed a machine-learning system to automatically measure Reimer’s migration percentage (RMP), acetabular index (ACI), head shaft angle (HSA), and neck shaft angle (NSA). The system automatically locates points around the femoral head and acetabulum on pelvic radiographs, and uses these to calculate measurements. The system was evaluated on 1,650 pelvic radiographs of children with CP (682 females and 968 males, mean age 8.3 years (SD 4.5)). Each radiograph was manually measured by five clinical experts. Agreement between the manual clinical measurements and the automatic system was assessed by mean absolute deviation (MAD) from the mean manual measurement, type 1 and type 2 intraclass correlation coefficients (ICCs), and a linear mixed-effects model (LMM) for assessing bias.Aims
Methods
Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment. Methods. A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained. Results. Among 256 hips with AI outputs, all six
The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable.Aims
Methods
Migration analysis after total joint arthroplasty are performed using EBRA analysis (Krismer et al., 1997) or - more accurate but also much more cost-intensive and time-consuming – via radiostereometric analysis (RSA). For the latter, additional radiographs from two inclined perspectives are needed in regular intervals in order to define the position of the implant relative to tantalum bone markers which have been implanted during surgery of the artificial joint (Fig. 1). Modern analysis software promises a migration precision along the stem axis of a hip implant of less than 100 μm (Witvoet-Brahm et al., 2007). However, as the analysis is performed semi-automatically, the results are still dependent on the subjective evaluation of the X-rays by the observer. Thus, the present phantom study aims at evaluating the inter- and intra-observer reliability, the repeatability as well as the precision and gives insight into the potential and limits of the RSA method. Considering published models, an RSA phantom model has been developed which allows a continuous and exact positioning of the prostheses in all six degrees of freedom (Fig. 2). The position sensitivities of the translative and rotative positioning components are 1 μm and 5 to 24, respectively. The roentgen setup and Model-Based RSA software (3.3, Medis specials bv, Leiden, Netherlands) was evaluated using the SL-PLUS® standard hip stem (size 7, Smith & Nephew, Baar, Switzerland). The inter-observer (10 repetitions) and intra-observer (3 observers) reliability have been considered. Additionally, the influences of the model repositioning and inclination as well as the precision after migration and rotation along the stem axis are investigated.Background
Materials and Methods
It has been well documented in the arthroplasty literature that lumbar degenerative disc disease (DDD) contributes to abnormal spinopelvic motion. However, the relationship between the severity or pattern of hip osteoarthritis (OA) as measured on an anteroposterior (AP) pelvic view and spinopelvic biomechanics has not been well investigated. Therefore, the aim of the study is to examine the association between the severity and pattern of hip OA and spinopelvic motion. A retrospective chart review was conducted to identify patients undergoing primary total hip arthroplasty (THA). Plain AP pelvic radiographs were reviewed to document the morphological characteristic of osteoarthritic hips. Lateral spine-pelvis-hip sitting and standing plain radiographs were used to measure sacral slope (SS) and pelvic femoral angle (PFA) in each position. Lumbar disc spaces were measured to determine the presence of DDD. The difference between sitting and standing SS and PFA were calculated to quantify spinopelvic motion (ΔSS) and hip motion (ΔPFA), respectively. Univariate analysis and Pearson correlation were used to identify morphological hip characteristics associated with changes in spinopelvic motion.Aims
Methods
The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed.Aims
Methods
Purpose. Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA). Conventional (manual) intraoperative stem adjustment may result in variability and inaccuracy of stem antetorsion (AT). Since March 2013, we have measured stem antetorsion with CT free Navigation system (OrthoPilot Navigation System THA Pro Ver4.2, B/Braun Aesculap Germany: Navi). We have developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment and adjustment of stem AT. We evaluated the accuracy and effectiveness of G-guide and navigation software as referenced to postoperative CT evaluation with 3D template system (Zed hip, LEXI, Japan). Method. Between March 2013 and December 2014, 50 patients underwent primary THA were evaluated. Surgeries were performed with routine techniques with a modified Hardinge approach with the patient at a lateral decubitus position in all cases. The G-guide consists of two parts: one attached to the lower leg and the other attached to the handle of the rasp. During surgery, AT value was determined with navigation at the time of final rasping of the femur. Additionally, the G-guide was utilised at the time of final rasp insertion. In intraoperative AT assessment using this instrument, a correction was required considering the discrepancy between the perpendicular to the posterior condylar axis and the longitudinal axis of the lower leg. The angle of discrepancy between posterior condylar line and femoral trans-epicondyler axis needs to be taken into consideration. Therefore, correction by the angle between the trans-epicondylar and posterior condylar lines (correction angle) was required for each patient when the intraoperative AT as measured by the G-guide. Therefore, the correction angle should be added to the AT value obtained from the G-guide for comparison with postoperative value measured with Zed Hip. Result. The discrepancy between the intraoperative G-guide with correction angle and postoperative Zed
Developmental dysplasia of the hip (DDH) describes a pathological relationship between the femoral head and acetabulum. Periacetabular osteotomy (PAO) may be used to treat this condition. The aim of this study was to evaluate the results of PAO in adolescents and adults with persistent DDH. Patients were divided into four groups: A, adolescents who had not undergone surgery for DDH in childhood (25 hips); B, adolescents who had undergone surgery for DDH in childhood (20 hips); C, adults with DDH who had not undergone previous surgery (80 hips); and D, a control group of patients with healthy hips (70 hips). The radiological evaluation of digital anteroposterior views of hips included the Wiberg angle (centre-edge angle (CEA)), femoral head cover (FHC), medialization, distalization, and the ilioischial angle. Clinical assessment involved the Harris Hip Score (HHS) and gluteal muscle performance assessment.Aims
Methods
The use of hip resurfacing arthroplasty (HRA) has largely regressed due to the fear of metal-on-metal bearings. However committed HRA users continue to assert the functional advantages that a geometry retaining implant would have on a patient”s hip. Currently worldwide, HRA is only recommended to men who demand an active lifestyle. Despite this precarious indication, it is not clear to what extent HRA has on higher activity function. The aim of this study was to determine the functional extent to which could be achieved with HRA. The primary objective is to assess the loading pattern change for patients implanted with HRA at high walking speeds and inclinations. The second objective is to compare their loading features to a healthy group to determine if a normal gait pattern could be achieved. Between 2012 and 2016, a total of 28 prospective unilateral HRA patients were analysed on an instrumented treadmill from a single centre. All 28 patient patients had a uniform implant type and had no other lower limb operations or disease. Perioperative plain orthogonal radiographs were used to measure hip length and global hip offset change. A healthy control group (n=35) were analysed to compare. All HRA patients gait characteristics were assessed at incrementally higher speeds and inclinations to determine the extent of improvement HRA has on a challenging activity. A Student t-test along with a multivariate analysis was done with significance set at α=0.05. Weight and height variance was accounted with Hof normalisation. The HRA and control group were reasonably matched for age (57 vs 55yrs), BMI (27 vs 25) and height (175 vs 170cm) respectively.
Background. Since 2011, the knee service at the Nuffield Orthopaedic Centre has been offering a neutralising medial opening wedge high tibial osteotomy (HTO) to a group of patients presenting with early medial osteoarthritis of the knee, varus alignment and symptoms for more than 2 years. During development of this practice an association was observed between this phenotype of osteoarthritis and the presence of CAM deformity at the hip. Methods. A retrospective cohort study. All patients who underwent HTO since 2011 were identified (n=30). Comparator groups were used in order to establish whether meaningful observations were being made: Control group: The spouses of a high-risk osteoarthritis cohort recruited for a different study at our unit (n=20) Pre-arthroplasty group: Patients who have undergone uni-compartmental arthroplasty (UKA) for antero-medial osteoarthritis (n=20)All patients had standing bilateral full-length radiographs available for analysis using in house developed Matlab-based software for
Some patients presenting with hip pain and instability and underlying acetabular dysplasia (AD) do not experience resolution of symptoms after surgical management. Hip-spine syndrome is a possible underlying cause. We hypothesized that there is a higher frequency of radiological spine anomalies in patients with AD. We also assessed the relationship between radiological severity of AD and frequency of spine anomalies. In a retrospective analysis of registry data, 122 hips in 122 patients who presented with hip pain and and a final diagnosis of AD were studied. Two observers analyzed hip and spine variables using standard radiographs to assess AD. The frequency of lumbosacral transitional vertebra (LSTV), along with associated Castellvi grade, pars interarticularis defect, and spinal morphological measurements were recorded and correlated with radiological severity of AD.Aims
Methods
Summary. Anatomical variations in hip joint anatomy are associated with both the presence and location of tibiofemoral osteoarthritis (OA). Introduction. Variations in hip joint anatomy can alter the moment-generating capacity of the hip abductor muscles, possibly leading to changes in the magnitude and direction of ground reaction force and altered loading at the knee. Through analysis of full-limb anteroposterior radiographs, this study explored the hypothesis that knees with lateral and medial knee OA demonstrate hip geometry that differs from that of control knees without OA. Patients and Methods. This cross-sectional study is an ancillary to the Multicenter Osteoarthritis Study (MOST), an observational cohort study of incident and progressive knee OA in community-dwelling men and women, ages 50–79 years. We report on 160 knees with lateral OA (LOA), 168 knees with medial OA (MOA), and 336 controls. All participants with LOA at the baseline MOST visit were included. An equal number of knees with MOA, and twice the number of control knees were then randomly selected. In participants with bilateral eligibility, a single knee was randomly selected so that all participants contributed only one case or one control knee to the analysis. Case knees were identified as having Kellgren/Lawrence (K/L) ≥ 2 with joint space narrowing (JSN) ≥ 1 in the specified compartment with no JSN in the adjoining compartment. Controls had no radiographic OA (K/L=0 or 1 and JSN=0) in either compartment. Hip joint anatomy parameters were assessed from full-limb standing radiographs using custom OsiriX software by an author (AB) blinded to knee OA status, and unreadable radiographs (N = 8) were discarded prior to unblinding. We measured parameters that influence the abductor moment arm of the hip, including: abductor lever arm, femoral offset, femoral neck length, femoral neck-shaft angle, height of hip centre, body weight lever arm, acetabular version, and abductor angle. All
To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases.Aims
Methods
In perfroming hip resurfacing arthroplasty, concern has been expressed as to the proximity of the femoral neurovascular bundle during the anterior capsulotomy and the risk of damage during this maneuver. We therefore aimed to identify the proximity of the femoral nerve, artery and vein during an anterior capsulotomy done during a hip resurfacing procedure using the posterior approach. A standard posterior approach was performed in 5 fresh frozen cadavic limbs. An anterior incision was then used to measure the distance of the femoral neurovascular structures to the anterior capsule. Measurements from the most posterior aspect of the vessels and nerves to the most anterior aspect of the anterior capsule were taken prior to hip dislocation. The femoral head was then dislocated, and measurements were made with the hip in both flexion and extension. In a separate group of eleven patients that underwent routine MR imaging of the
In this paper operations are discussed that improve the dysplastic acetabular roof in developmental dislocation of the hip (DDH) of children up to 10 years. In the first year of life acetabular dysplasia can be treated successfully by flexion-abduction splints and plaster casts in „human position“. From the second year on, only slight dysplasias can heal spontaneously or be treated conservatively. Then the steep acetabular roof has to be osteotomized and levered down to a normal angle and coverage to avoid redislocation or residual dysplasia. Different procedures have been described in the course of time. Two osteotomies are chiseling in the anterior to posterior direction. Salters innominate osteotomy levers the whole acetabulum with the lower part of the pelvis in an anterolateral direction around an axis passing through the pubic symphysis and the posterior part of the osteotomy. In Pembertons osteotomy the hinge for turning down the acetabular roof is the last, posterior, transverse cortical segment over the tri-radiate cartilage, short before the sciatic notch. Osteotomies chiseling from lateral in medial direction have been described already by Albee (1915) and Jones (1920). Lance (1925) propagated this technique in Europe. Here the acetabular roof is partially osteotomized in a thickness of 5–7 mm. Only the lateral part of the acetabulum is brought into the horizontal position. Wiberg in 1939 used this technique, but in 1953 he was the first to publish a full osteotomy what Dega called 1973 a transiliac osteotomy. Dega had originally learned the technique of Lance, but in 1963 when he reduced high dislocations after the technique of Colonna, he performed also a full transiliac osteotomy. After the Symposium of Chapchal in Basel 1965 we started in Berlin also with the complete acetabular osteotomy. With the control of an image intensifier the blade of the osteotome is driven toward the posterior rim of the tri-radiate cartilage leaving only a small bony rim above. Anteriorly the blade passes through the ant. inf. iliac spine. Posteriorly it just enters the sciatic notch. Here we check the blade position by direct palpation. The acetabulum is bent down partly in the small rim of bone left and mainly in the triradiate cartilage. Angles up to 50° have been achieved, which you cannot reach by other techniques. In the beginning we have combined after Mittelmeier and Witt this acetabuloplasty with a varus osteotomy of the femur. In our long-time follow-up (Brüning et al. 1988,1990) however, we found in almost 50% a subcapital coxa valga or a so-called head-in-neck-position of the femoral head. Then we avoided varusosteotomies and had good results without it (Pothmann). To keep the acetabular roof in the new position we used first bone wedges from the varus osteotomy, then deproteinized bone wedges from animals, and today deep frozen wedges of human femoral heads of the bone bank, sterilized at 121 degrees C for 20 min. (Ekkernkamp, Katthagen). A firm layer of cortical bone laterally is necessary. Reinvestigations have proven the stability of this material too ( Pothmann). This type of acetabular osteotomy in our and other authors opinion is the best. Salters osteotomy is not as efficient in severe dysplasia. And in older children it produces a decrease in anteversion of the acetabulum, which may limit internal rotation of the hip and cause osteoarthritis if it does not improve. In Pembertons osteotomy one cannot use the image intensifier, which is of great help to perform the osteotomy exactly and also the levering of the acetabulum to the optimal coverage. Our first long-time follow-up of children with additional varus-osteotomies (Brüning et al.) reviewed 90 hip joints in 67 children. The age at operation was in average 3.6 years, the age at follow-up 15 years. Clinical results. 98% of the patients had no pain or only occasional, no limitation of movement and normal or almost normal gait. The Trendelenburg sign was negative in 71% of the cases, grade 1 in 15.5% and grade 3 in 13.5%. Radiological evaluation. The mean value of the AC-angle (acetabular index) preoperatively was 33.8°, postoperatively normal with 16.3°. The acetabular angle of the weightbearing zone was at follow-up 9.7°, which is normal too. At the age of less than 18 years the CE angle of 25,9° was normal too, as well the instability (protrusion) index of Reimers of 12.3 % and the distance femoral head to teardrop figure with 8.8 mm. In our study group of hip dysplasia we introduced a score of normal values of
Loss of bone stock is a major problem in revision surgery of the hip. Impaction bone grafting of the femur is frequently used when dealing with deficient bone stock. In this retrospective study a consecutive series of 68 patients (69 hips) who had revision of a hip replacement with femoral impaction grafting were reviewed. Irradiated bone allograft was used in all
A retrospective study of the development of the hip opposite a congenitally dislocated hip was carried out to identify at an early age those hips which would develop abnormally. Recognised radiological measurements were used showing the development of the joints with age. The development was compared with that of a control group of normal
A recently developed parametric geometrical finite element model (p-FEM) was adapted to the specific