Advertisement for orthosearch.org.uk
Results 1 - 20 of 1081
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 78 - 78
1 Dec 2021
Benech N LEVAST B Gasc C Cecile B Senneville E Lustig S Boutoille D Dauchy F Zeller V Cazanave C Josse J Laurent F Ferry T
Full Access

Aim. Bone and joint infections (BJI) need frequently prolonged antibiotic treatment at high dosage for a total of 6 or 12 weeks depending the type of infection. Impact of such prolonged antibiotic exposure on the gut microbiota has never been assessed. Method. We performed a national multicentric prospective study of patients with BJI to monitor the gut microbiota dynamic all along antimicrobial treatment. Clinical data and stool collection were performed at the baseline visit (B) within 24h before starting antibiotics, at the end of the treatment (EOT) and 2 weeks after antibiotic withdrawal during a follow-up visit (FU). Microbiota composition was determined by shotgun metagenomic sequencing. Biological markers of gut permeability and inflammation were monitored at each time point. Results. Sixty-two patients were enrolled: 27 native BJI, 14 osteosynthesis-related BJI and 21 prosthetic joint infections (PJI). At EOT there was a significant loss of alpha-diversity that recovered at FU in patients with native BJI and PJI but not in patients with osteosynthesis-related BJI (p<0.05, Wilcoxon test). At EOT, we observed an increase of Proteobacteria and Bacteroidetes that partially recovered at FU. Principal Component Analysis (PCoA) of the Bray Curtis distance, showed a significant change of the gut microbiota at the end of treatment compared to baseline (p<0.01, PERMANOVA) that only partially recover at FU. The taxonomic analysis showed that microbiota composition at FU does not differ significantly at the genus level when comparing patients treated for 6 weeks to patients treated for 12 weeks. No particular antibiotic (especially fluoroquinolones) was associated with a lower Shannon index or distinct dynamic of recovery at the end of treatment. PCoA analysis of the Bray Curtis distance shows that patients with elevated plasma level of CRP (≥5mg/L) at EOT had a distinct gut microbial composition compared to others. Conclusions. In patients with BJI, antibiotics altered the gut microbiota diversity and composition with only partial recovery 2 weeks after antibiotic withdrawal, independently on the duration of the therapy and on the type of the antibiotic used. Elevated CRP at EOT might reflect persistent alteration of the gut microbiota. Assessment of long-term impact after the end of treatment is on-going


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 103 - 103
1 Dec 2022
Sandoval C Patel N Dragan A Terner M Webster G Dunbar M Bohm E
Full Access

In Canada, hip and knee replacements are each among the top three surgeries performed annually. In 2020, surgeries across the country were cancelled in response to the COVID-19 pandemic. We examined the impact on these joint replacement surgeries throughout the year. Using the Discharge Abstract Database and National Ambulatory Care Reporting System, we developed a dataset of all 208,041 hip and knee replacements performed in Canada (except from Quebec) between January 1, 2019 to December 31, 2020. We compared patient and surgical characteristics (including sex, age, main diagnosis, and type of surgery (planned/urgent, primary/revision, inpatient/day surgery) in 2020 to 2019. In 2020, hip and knee replacements volumes decreased by 18.8% compared to 2019. In April and May 2020, hip and knee replacements fell by 69.4% and 93.8%, respectively, compared to the same period in 2019. During those months, 66.5% of hip replacements were performed to treat hip fracture versus 20.2% in April and May 2019, and 64.5% of knee replacements were primaries versus 93.0% in April and May 2019. Patterns by patient age group and sex were similar compared to 2019. These patterns were similar across all provinces. By the summer, planned surgeries resumed across the country and volumes mostly returned to pre-pandemic monthly levels by the end of the year. We also found that there was an increase in the proportion of hip and knee replacements done as day surgery, with 4% in 2020 versus 1% in 2019, and patients undergoing day surgery replacement for osteoarthritis were older, with a median age of 64 for hip patients and 65 for knee patients, versus 63 for both joints the previous year. As a result of the COVID-19 pandemic, there was a notable drop in 2020 of hip and knee replacements performed in Canada. With the demand for joint replacements continuing to grow, the resulting backlog will have an immediate, significant impact on wait lists and patient quality of life. The shift to a greater proportion of joint replacements performed as day surgeries may have an effect on patient outcomes as well shifts in access to care. It will be important to continue monitor patient outcomes following day surgery and the impact on patients for which day surgery was not an option


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 151 - 151
1 May 2016
Kaneeda T Zhao X Matsuura H
Full Access

Impact relief ability of Metal-on-Metal artificial hip joint with multi-garter spring using drop impact tester for practical use. Toshiaki Kaneeda, Xinming Zhao and Hiroshi Matsuura. Metal-on-metal (MoM) joints can provide better wear properties than hard-on-polymer joints, leading to reducing osteolysis. However during gait, MoM hip joints have no material to relieve impact. These impacts can cause severe pain in postoperative patients. Kaneeda proposed double-shell MoM artificial hip joints in which multi garter springs were inserted between the inner and outer acetabular shell as an impact relief device. The proposed double-shell metal-on-metal artificial hip joint is composed of two layers, as shown in Fig. 11). A garter spring is usually used when by loading and a compression stress from the outside to the center axis. In the model testing for garter spring, it is demonstrated that garter spring had impact relief ability, then using dual garter springs could lead to better impact relief ability than single one2). In this work, the impact relief ability of model hip joint were investigated by using the Instron CEAST 9340 machine as shown in Fig. 2. The machine is a floor standing impact system designed to deliver 0.30–405J of energy and equipped with precise locating system for height. A holding device of double-shell cup was made to fix the right position. A shape of drop impact weight was modified for this experiment. The model hip joint was applied vertical load over 6000N, which is estimated to be equal to maximum vertical load during jumping. The ability in the case of single garter spring and dual garter springs was evaluated in the model hip joint, comparing with UHMWPE liner in the same size of femur head. Each testing was conducted 10 times. Fig. 3 shows load-time curve detected. From the results, it can be seen that in both case Load L gradually rise with Time T, then reach maximum values, finally L gently drop: maximum impact load as well as maximum impact load arriving time also presented nearly the same values. Much differences in shape of the curve between model hip joint with dual garter springs and UHMWPE liner could not be recognized. The model hip joint with dual garter springs may has enough impact relief ability


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 29 - 29
22 Nov 2024
Trebše N Blas M Kanalec T Angelini K Filipič T Levašic V Trebse R
Full Access

Aim. There is limited data on the frequency and impact of untoward events such as glove perforation, contamination of the surgical field (drape perforation, laceration, detachment), the unsterile object in the surgical field (hair, sweat droplet…), defecation, elevated air temperature…that may happen in the operating theatre. These events should influence the surgical site infection rate but it is not clear to what extent. We wanted to calculate the frequency and measure the impact of these events on the infection and general revision rate. Method. In our institution, scrub nurses prospectively and diligently record untoward events in the theatres. We have an institutional implant registry with close to 100% data completion since 2001, and surgeons register complications before discharge. We analysed the respective databases and compared the revision and infection rate in the group with untoward events with the outcome of all arthroplasty patients within the same period. Two-tailed Z statistical test was used for analysis. Results. Between 1.1.2012 and 31.12.2018 we operated 13574 prosthetic joints: 6232 primary THR (total hip replacement) and 5466 primary KR (total and partial knee replacement) and 1245 and 631 revisions respectively. During this period, we recorded 372 events (2.74%) including 20 (0.15 %) defecations, 40 (0.29 %) unsterile object in the surgical field, 73 (0.54%) field sterility violations, 45 (0.33 %) glove perforations, 45 (0.33 %) occasions with elevated air temperature, 106 (0.78%) with guests in the OR, 11 (0.08%) with wound near the surgical field, and 32 (0.24%) with other events. We followed the patients till 1.1.2022, in this time we recorded 27 (7.26%) reoperations in the cohort with untoward events. There were 9 (2.42%) infections and 18 (4.84%) aseptic revisions in the group with unwanted events. The infection rate for all TJR (total joint replacement) from the period 2012-2018, followed till 1.1.2022 was 2.23%, the revision rate for any reason was 4.37%. For all THR (primary and revision) the infection rate was 0.84%, the overall revision rate was 3.18% and for the KR (primary and revision) 1.71% and 5,82% respectively. The difference is significant at p>0.05 for infection rate. Conclusions. The potentially serious sterility disruptive events in the operative rooms did result in an increased infection rate but not an increase in revision rate. There is no data about the rate and the impact of these events besides for perforated surgical gloves with higher reported incidences than in our study influencing infection rate if perioperative antibiotic prophylaxis was not used. Ours is the first study reporting the impact of these unwanted events in the operating theatre. Key words. orthopaedic surgery, unwanted events, revision rate


Bone & Joint Open
Vol. 3, Issue 10 | Pages 777 - 785
10 Oct 2022
Kulkarni K Shah R Mangwani J Dias J

Aims. Deprivation underpins many societal and health inequalities. COVID-19 has exacerbated these disparities, with access to planned care falling greatest in the most deprived areas of the UK during 2020. This study aimed to identify the impact of deprivation on patients on growing waiting lists for planned care. Methods. Questionnaires were sent to orthopaedic waiting list patients at the start of the UK’s first COVID-19 lockdown to capture key quantitative and qualitative aspects of patients’ health. A total of 888 respondents were divided into quintiles, with sampling stratified based on the Index of Multiple Deprivation (IMD); level 1 represented the ‘most deprived’ cohort and level 5 the ‘least deprived’. Results. The least deprived cohort were older (mean 65.95 years (SD 13.33)) than the most deprived (mean 59.48 years (SD 13.85)). Mean symptom duration was lower in the least deprived areas (68.59 months (SD 112.26)) compared to the most deprived (85.85 months (SD 122.50)). Mean pain visual analogue scores (VAS) were poorer in the most compared to the least deprived cohort (7.11 (SD 2.01) vs 5.99 (SD 2.57)), with mean mood scores also poorer (6.06 (SD 2.65) vs 4.71 (SD 2.78)). The most deprived areas exhibited lower mean quality of life (QoL) scores than the least (0.37 (SD 0.30) vs 0.53 (SD 0.31)). QoL findings correlated with health VAS and Generalized Anxiety Disorder 2-item (GAD2) scores, with the most deprived areas experiencing poorer health (health VAS 50.82 (SD 26.42) vs 57.29 (SD 24.19); GAD2: 2.94 (SD 2.35) vs 1.88 (SD 2.07)). Least-deprived patients had the highest self-reported activity levels and lowest sedentary cohort, with the converse true for patients from the most deprived areas. Conclusion. The most deprived patients experience poorer physical and mental health, with this most adversely impacted by lengthy waiting list delays. Interventions to address inequalities should focus on prioritizing the most deprived. Cite this article: Bone Jt Open 2022;3(10):777–785


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 210 - 210
1 Sep 2012
Cummins F Kelly D Kenny P
Full Access

Background and purpose. The two most common complications of femoral impaction bone grafting are femoral fracture and massive implant subsidence. We investigated fracture forces and implant subsidence rates in embalmed human femurs undergoing impaction grafting. The study consisted of two arms, the first examining the force at which femoral fracture occurs in the embalmed human femur, and the second examining whether significant graft implant/subsidence occurs following impaction at a set force at two different impaction frequencies. Methods. Using a standardized impaction grafting technique with modifications, an initial group of 17 femurs underwent complete destructive impaction testing, allowing sequentially increased, controlled impaction forces to be applied until femoral fracture occurred. A second group of 8 femurs underwent impaction bone grafting at constant force, at an impaction frequency of 1 Hz or 10 Hz. An Exeter stem was cemented into the neomedullary canals. These constructs underwent subsidence testing simulating the first 2 months of postoperative weight bearing. Results. No femur fractured below an impaction force of 0.5 kN. 15/17 of the femurs fractured at or above 1.6 kN of applied force. In the second group of 8 femurs, all of which underwent femoral impaction grafting at 1.6 kN, there was no correlation between implant subsidence and frequency of impaction. Average subsidence was 3.2 (1–9) mm. Interpretation. It is possible to calculate a force below which no fracture occurs in the embalmed human femur undergoing impaction grafting. Higher impaction frequency at constant force did not reduce rates of implant subsidence in this experiment


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 7 - 7
24 Nov 2023
Martos MS Boadas L Trebse R Marais L Ruiz PS Vaznaisiene D Grenho A Ferrari MC Soriano A
Full Access

Aim. Two-stage replacement is a frequent procedure in patients with chronic PJI. However, results in the literature after this procedure differ, ranging from 54% to 100% of infection eradication. Positive cultures at reimplantation, when performing the second stage, are perceived as a risk factor for reinfection. This study aims to determine the impact of positive cultures during the second stage on the outcome of patients undergoing a 2-stage septic replacement and the impact of antibiotic holidays between the first and the second stage. Method. We systematically searched four databases from inception to May 31, 2022. We combined terms related to PJI, joint replacement and culture results. We analysed the risk of failure when positive cultures at second stage and performed a subgroup analysis by antibiotic holiday period. Results. We included 24 studies with 2387 patients of which 432 had positive cultures during second stage (18.09%). Global failure rate was 18.01% (430 patients). When dividing failure by culture results during second stage, we found that failure in positive group was 37.01% (161/432 patients) and failure in negative group was 13.7% (269/1953 patients). In the meta-analysis (MA) the odds ratio (OR) was 4.047 (95% CI: 2.954–5.544). When performing the subgroup analysis by antibiotic holidays we found that the rate of positive cultures without and with holidays was 21.3% and 16.05%, respectively. Failure rate without holidays was 15% (90/600 patients) and with holidays was 17.3% (202/1165 patients) (p=0.21). Failure in each group was higher when cultures were positive (without holidays, 25% vs 12.2%, p=0.0003, and with holidays 41.1% vs 12.7%, p<0.0001). In the MA we found that those studies in which antibiotic holiday was reported had higher risk of failure when cultures were positive during second stage (OR 4.798 95%IC 3.142–7.325). When studies reported no antibiotic holidays also had a higher risk of failure when cultures where positive (OR 2.225 95%CI 1.103–4.489), though it was lower. Conclusions. There exists a higher risk of failure after a two-stage septic replacement when cultures are positive during reimplantation. Patients who followed no antibiotic holidays or antibiotic holidays before reimplantation have similar failure rate when cultures are negative. In both groups they have a higher risk of failure when cultures are positive, having higher risk those positive patients in the antibiotic holidays group. Therefore, importance in detecting these patients before reimplantation is crucial to ensure higher survival rates


Bone & Joint Open
Vol. 1, Issue 11 | Pages 676 - 682
1 Nov 2020
Gonzi G Gwyn R Rooney K Boktor J Roy K Sciberras NC Pullen H Mohanty K

Aims. The COVID-19 pandemic has had a significant impact on the provision of orthopaedic care across the UK. During the pandemic orthopaedic specialist registrars were redeployed to “frontline” specialties occupying non-surgical roles. The impact of the COVID-19 pandemic on orthopaedic training in the UK is unknown. This paper sought to examine the role of orthopaedic trainees during the COVID-19 and the impact of COVID-19 pandemic on postgraduate orthopaedic education. Methods. A 42-point questionnaire was designed, validated, and disseminated via e-mail and an instant-messaging platform. Results. A total of 101 orthopaedic trainees, representing the four nations (Wales, England, Scotland, and Northern Ireland), completed the questionnaire. Overall, 23.1% (23/101) of trainees were redeployed to non-surgical roles. Of these, 73% (17/23) were redeployed to intensive treatment units (ITUs), 13% (3/23) to A/E, and 13%(3/23%) to general medicine. Of the trainees redeployed to ITU 100%, (17/17) received formal induction. Non-deployed or returning trainees had a significant reduction in sessions. In total, 42.9% (42/101) % of trainees were not timetabled into fracture clinic, 53% (53/101) of trainees had one allocated theatre list per week, and 63.8%(64/101) of trainees did not feel they obtained enough experience in the attached subspecialty and preferred repeating this. Overall, 93% (93/101) of respondents attended at least one weekly online webinar, with 79% (79/101) of trainees rating these as useful or very useful, while 95% (95/101) trainees attended online deanery teaching which was rated as more useful than online webinars (p = 0.005). Conclusion. Orthopaedic specialist trainees occupied an important role during the COVID-19 pandemic. COVID-19 has had a significant impact on orthopaedic training. It is imperative this is properly understood to ensure orthopaedic specialist trainees achieve competencies set out in the training curriculum. Cite this article: Bone Joint Open 2020;1-11:676–682


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 129 - 129
1 Jul 2020
Petruccelli D Wood T Winemaker MJ De Beer J
Full Access

Overall, hip and knee total joint replacement (TJR) patients experience marked benefit, with reported satisfaction rates of greater than 80% with regard to pain relief and improved function. However, many patients experience ‘nuisance’ symptoms, an annoyance which may cause discomfort, which can negatively impact postoperative satisfaction. The purpose of this study was to evaluate the prevalence of nuisance symptoms among TJR patients and impact on overall patient satisfaction. A prospective survey study to assess type and prevalence of primary hip/knee TJR related nuisance symptoms, and impact on patient satisfaction at six-months to one-year post-TJR was conducted. The survey was administered over a one-year period at one academic arthroplasty centre. Survey questions tapped occurrence of commonly reported nuisance symptoms (e.g. localized pain, swelling, stability, incision appearance/numbness, stiffness, clicking/noise, ability to perform activities of daily living), and impact of the symptom on overall hip/knee satisfaction rated on a 10-point visual analogue scale (VAS), (0=no impact, 10=to a great extent). Overall VAS satisfaction with TJR was also assessed (0=not at all satisfied, 10=extremely satisfied). Survey responses were analysed using descriptive statistics. The sample comprised of 974 primary TJR patients, including 590 knees (61%) and 384 hips 39%) who underwent surgery over a one-year period. Among knees, the most commonly reported nuisance symptoms and associated impact to satisfaction per mean VAS scores included: difficulty kneeling (78.2%, mean VAS 4.3, ±3.3), limited ability to run or jump (71.6%, VAS 3.3, ±3.3), numbness around incision (46.3%, VAS 3.8, ±3.3), clicking/noise from the knee (44.2%, VAS 2.7, ±2.7) and stiffness (43.3%, 3.3, ±2.7) following knee arthroplasty. Overall, 88.1% of knee patients surveyed experienced at least one self-reported nuisance symptom at one-year postoperative. Mean overall VAS satisfaction with knee TJR was reported as 9/10 (±1.7). Among hip TJR patients, the most commonly reported nuisance symptoms and associated impact to satisfaction per VAS scores were: limited ability to run or jump (68.6%, VAS 3.4, ±3.4), muscular pain in the thigh (44.8%, VAS 3 ±2.7), limp when walking (37.6%, VAS 4.1, ±3.2), hip stiffness (31%, VAS 3.1, ±2.4), and new or worsening low back pain (24.3%, VAS 2.9, ±2.5). Overall, 93.7% of patients experienced at least one self-reported nuisance symptom at one-year postoperative. Mean overall VAS satisfaction following total hip arthroplasty at one year was reported as 8.9/10 (±1.7). Nuisance symptoms following primary total hip and knee arthroplasty are very common. Despite the high prevalence of such symptoms, impact of individual symptoms to overall TJR satisfaction is minimal and overall TJR patient satisfaction remains high. Careful preoperative counselling regarding the prevalence of such symptoms is prudent and will help establish realistic expectations following primary hip and knee TJR


Bone & Joint Open
Vol. 1, Issue 10 | Pages 645 - 652
19 Oct 2020
Sheridan GA Hughes AJ Quinlan JF Sheehan E O'Byrne JM

Aims. We aim to objectively assess the impact of COVID-19 on mean total operative cases for all indicative procedures (as outlined by the Joint Committee on Surgical Training (JCST)) experienced by orthopaedic trainees in the deanery of the Republic of Ireland. Subjective experiences were reported for each trainee using questionnaires. Methods. During the first four weeks of the nationwide lockdown due to COVID-19, the objective impact of the pandemic on each trainee’s surgical caseload exposure was assessed using data from individual trainee logbook profiles in the deanery of the Republic of Ireland. Independent predictor variables included the trainee grade (ST 3 to 8), the individual trainee, the unit that the logbook was reported from, and the year in which the logbook was recorded. We used the analysis of variance (ANOVA) test to assess for any statistically significant predictor variables. The subjective experience of each trainee was captured using an electronic questionnaire. Results. The mean number of total procedures per trainee over four weeks was 36.8 (7 to 99; standard deviation (SD) 19.67) in 2018, 40.6 (6 to 81; SD 17.90) in 2019, and 18.3 (3 to 65; SD 11.70) during the pandemic of 2020 (p = 0.043). Significant reductions were noted for all elective indicative procedures, including arthroplasty (p = 0.019), osteotomy (p = 0.045), nerve decompression (p = 0.024) and arthroscopy (p = 0.024). In contrast, none of the nine indicative procedures for trauma were reduced. There was a significant inter-unit difference in the mean number of total cases (p = 0.029) and indicative cases (p = 0.0005) per trainee. We noted that 7.69% (n = 3) of trainees contracted COVID-19. Conclusion. During the COVID-19 pandemic, the mean number of operative cases per trainee has been significantly reduced for four of the 13 indicative procedures, as outlined by the JCST. Reassignment of trainees to high-volume institutions in the future may be a plausible approach to mitigate significant training deficits in those trainees worst impacted by the reduction in operative exposure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 119 - 119
10 Feb 2023
Lai S Zhang X Xue K Bubra P Baba M
Full Access

The second wave of COVID-19 infections in 2021 resulting from the delta strain had a significantly larger impact on the state of New South Wales, Australia and with it the government implemented harsher restrictions. This retrospective cohort study aims to explore how the increased restrictions affected hand trauma presentations and their treatment. Retrospective analysis was performed on patients who underwent hand surgery from the period of June 23 – August 31 in 2020 and 2021 at a level one trauma centre in Western Sydney. During the second-wave lockdown there was an 18.9% decrease in all hand trauma presentations. Despite widespread restrictions placed on the manufacturing, wholesale, retail and construction industries, there was an insignificant difference in work injuries. Stay-at-home orders and reduced availability of professional tradespersons likely contributed to an increase in DIY injuries. Significant reductions in metacarpal and phalangeal fractures coincided with significantly curtailed sporting seasons. The findings from this study can assist in predicting the case-mix of hand trauma presentations and resource allocation in the setting of future waves of COVID-19 and other infectious diseases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 48 - 48
24 Nov 2023
Dos Santos MV Meller S Perka C Trampuz A Renz N
Full Access

Aim. Antimicrobial suppression has shown to significantly improve treatment success of streptococcal periprosthetic joint infection (PJI) compared to 12-week standard antimicrobial therapy, however, only short-term follow-up was investigated. In this study we assessed the impact of suppression on the long-term outcome of streptococcal PJI. Method. Consecutive patients with streptococcal PJI (defined by EBJIS criteria) treated 2009–2021 were prospectively included and allocated into standard and suppression (> 6 months) treatment group. Infection-free survival was assessed with Kaplan-Meier-method and compared between the groups with log rank test. Rates of infection-free, streptococcal infection-free and relapse-free status as well as tolerability of suppression were assessed. Results. Sixty-three PJI episodes (36 knee, 26 hip and one shoulder prosthesis) of patients with a median age of 70 (35–87) years were included. Twenty-seven (43%) were females. Predominant pathogens were S. agalactiae (n=20), S. dysgalactiae (n=18) and S. mitis/oralis (n=13). The main surgical procedures used were two-stage exchange (n=35) and prosthesis retention (n=21). Standard 12-week treatment was administered in 33 patients and suppression in 30 patients, of whom 10 had ongoing suppression and 20 had discontinued antibiotics at time of follow-up. Used oral antibiotics for suppression were amoxicillin (n=29), doxycycline (n=5) and clindamycin (n=2); 6 patients changed antibiotic substance due to side effects. The median follow-up time was 3.9 (0.3–13.3) years. Infection-free survival after 7.5 years was 38% with standard treatment and 62% with suppression (p=0.038). Of all failures, 52% (14/27) were due to streptococci. Suppression was effective in preventing streptococcal infection for the duration of antimicrobial treatment, however, after discontinuation relapses or new infections due to streptococci occurred in 5/20 (25%) patients and infection with any Streptococcus spp. was observed in 9/19 (47%) failures with standard treatment, 5/6 (83%) failures after discontinuing suppression and none during suppression. All failures in patients with ongoing suppression were caused by gram-negative rods. Conclusion. At long-term follow-up, the success rate was superior with suppression compared to standard treatment. Most failures after stopping suppression were caused by streptococci, whereas failures under suppression were caused by aerobic gram-negative rods


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 54 - 54
1 Dec 2022
Pereira Duarte M Joncas J Parent S Duval M Chemaly O Brassard F Mac-Thiong J Barchi S Labelle H
Full Access

There is a significant positive association between hours of brace wear and rate of success in the treatment of Adolescent Idiopathic Scoliosis (AIS). The abandon rate reported in the literature averages 18%. In a recent randomized trial conducted at our center; the abandon rate was 4%. We aim to document the abandon rate towards brace treatment during the COVID-19 pandemic and its impact on AIS progression. We reviewed a database of AIS patients recruited between March and September 2020. Inclusion criteria were patients with AIS under brace treatment according to SRS criteria. The patients were divided in 2 cohorts: those with a self-reported good adherence to treatment and those who voluntarily abandoned treatment during follow-up. Patients with irregular adherence were excluded. Data analysis included age, gender, Risser stage, type of brace, Cobb angles at first visit and last follow-up (mean 11 months) and % of progression. Unpaired student tests were used for comparison. 154 patients met inclusion criteria. 20 patients were excluded due to irregular adherence. 89 patients (age: 12.1 y.o. ±1.4) reported good adherence to treatment, while 45 patients (age: 12.6 y.o. ±1.5) abandoned treatment, an abandon rate of 29%. The cohort of compliant patients started treatment with a mean main thoracic (MT) curve of 26° and finished with 27°. The mean difference between measurements was +0.65°±7.5; mean progression rate was −4.6%. However, patients who abandoned treatment started with a mean MT curve of 28° and finished with 33°, with a mean increase of +5°±8 and a mean progression rate of −11%. The differences between the 2 cohorts were statistically significant (p=0.002). Five (5) patients from the abandon group were offered for surgery because of curve progression. The abandon rate of brace treatment in AIS significantly increased during the first wave of COVID-19 pandemic. Patients who voluntarily discontinued treatment had significant increases in curve progression and surgical indication rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 21 - 21
23 Feb 2023
Sandow M Page R Hatton A Peng Y
Full Access

The 2021 Australian Orthopaedic Association National Joint Replacement Registry report indicated that total shoulder replacement using both mid head (TMH) length humeral components and reverse arthroplasty (RTSA) had a lower revision rate than stemmed humeral components in anatomical total shoulder arthroplasty (aTSA) - for all prosthesis types and diagnoses. The aim of this study was to assess the impact of component variables in the various primary total arthroplasty alternatives for osteoarthritis in the shoulder. Data from a large national arthroplasty registry were analysed for the period April 2004 to December 2020. The study population included all primary aTSA, RTSA, and TMH shoulder arthroplasty procedures undertaken for osteoarthritis (OA) using either cross-linked polyethylene (XLPE) or non-cross-linked polyethylene (non XLPE). Due to the previously documented and reported higher revision rate compared to other anatomical total shoulder replacement options, those using a cementless metal backed glenoid components were excluded. The rate of revision was determined by Kaplan-Meir estimates, with comparisons by Cox proportional hazard models. Reasons for revision were also assessed. For a primary diagnosis of OA, aTSA with a cemented XLPE glenoid component had the lowest revision rate with a 12-year cumulative revision rate of 4.7%, compared to aTSA with cemented non-XLPE glenoid component of 8.7%, and RTSA of 6.8%. The revision rate for TMH was lower than aTSA with cemented non-XLPE, but was similar to the other implants at the same length of follow-up. The reason for revision for cemented aTSR was most commonly component loosening, not rotator cuff deficiency. Long stem humeral components matched with XLPE in aTSA achieve a lower revision rate compared to shorter stems, long stems with conventional polyethylene, and RTSA when used to treat shoulder OA. In all these cohorts, loosening, not rotator cuff failure was the most common diagnosis for revision


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 39 - 39
1 Oct 2022
Vargas-Reverón C Soriano A Fernandez-Valencia J Martinez-Pastor JC Morata L Muñoz-Mahamud E
Full Access

Aim. Our aim was to evaluate the prevalence and impact of unexpected intraoperative cultures on the outcome of total presumed aseptic knee and hip revision surgery. Method. Data regarding patients prospectively recruited in our center, who had undergone elective complete hip and knee revision surgery from January 2003 to July 2017 with a preoperative diagnosis of aseptic loosening was retrospectively reviewed. Partial revisions and patients with follow up below 60 months were excluded from the study. The protocol of revision included at least 3 intraoperative cultures. Failure was defined as the need for re-revision due to any-cause at 5 years and/or the need for antibiotic suppressive therapy. Results. A total of 608 cases were initially included in the study, 53 patients were excluded. 123 hip and 432 knee revision surgeries were included. 420 cases (75.7%) had all cultures negative, 114 (20.5%) a single positive culture or two of different microorganisms and 21 (3.8%) had at least 2 positive cultures for the same microorganism. Early failure was found in 4.8% (1/21) of the patients with missed low grade infection. The presence of positive cultures during total exchange was not associated with a higher failure rate than in those with negative cultures (44 of 420, 10.5%). In contrast, patients revised before 24 months had a significant higher rate of re-revision, 18% (15/83) vs. 8.4%. Conclusions. Total hip and knee revisions with unexpected positive cultures were not significantly associated with a higher re-revision risk at 5 years of follow-up. Representing an overall good prognosis. However, revision surgeries performed within the first 24 months have a higher rate of failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 24 - 24
1 Dec 2022
Searle S Reesor M Sadat M Bouchard M
Full Access

The Ponseti method is the gold standard treatment for clubfoot. It begins in early infancy with weekly serial casting for up to 3 months. Globally, a commonly reported barrier to accessing clubfoot treatment is increased distance patients must travel for intervention. This study aims to evaluate the impact of the distance traveled by families to the hospital on the treatment course and outcomes for idiopathic clubfoot. No prior studies in Canada have examined this potential barrier. This is a retrospective cohort study of patients managed at a single urban tertiary care center for idiopathic clubfoot deformity. All patients were enrolled in the Pediatric Clubfoot Research Registry between 2003 and April 2021. Inclusion criteria consisted of patients presenting at after percutaneous Achilles tenotomy. Postal codes were used to determine distance from patients’ home address to the hospital. Patients were divided into three groups based on distance traveled to hospital: those living within the city, within the Greater Metro Area (GMA) and outside of the GMA (non-GMA). The primary outcome evaluated was occurrence of deformity relapse and secondary outcomes included need for surgery, treatment interruptions/missed appointments, and complications with bracing or casting. A total of 320 patients met inclusion criteria. Of these, 32.8% lived in the city, 41% in the GMA and 26% outside of the GMA. The average travel distance to the treatment centre in each group was 13.3km, 49.5km and 264km, respectively. Over 22% of patients travelled over 100km, with the furthest patient travelling 831km. The average age of presentation was 0.91 months for patients living in the city, 1.15 months for those within the GMA and 1.33 months for patients outside of the GMA. The mean number of total casts applied was similar with 7.1, 7.8 and 7.3 casts in the city, GMA and non-GMA groups, respectively. At least one two or more-week gap was identified between serial casting appointments in 49% of patients outside the GMA, compared to 27% (GMA) and 24% (city). Relapse occurred in at least one foot in 40% of non-GMA patients, versus 27% (GMA) and 24% (city), with a mean age at first relapse of 50.3 months in non-GMA patients, 42.4 months in GMA and 35.7 months in city-dwelling patients. 12% of the non-GMA group, 6.8% of the GMA group and 5.7% of the city group underwent surgery, with a mean age at time of initial surgery of 79 months, 67 months and 76 months, respectively. Complications, such as pressure sores, casts slips and soiled casts, occurred in 35% (non-GMA), 32% (GMA) and 24% (city) of patients. These findings suggest that greater travel distance for clubfoot management is associated with more missed appointments, increased risk of relapse and treatment complications. Distance to a treatment center is a modifiable barrier. Improving access to clubfoot care by establishing clinics in more remote communities may improve clinical outcomes and significantly decrease the burdens of travel on patients and families


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 42 - 42
22 Nov 2024
Mu W Tarabichi S Xu B Wang F Li Y Lizcano JD Zhang X Parvizi J Cao L
Full Access

Aim. This study aimed to evaluate the impact of intraoperative direct sonication on the yield of traditional culture and the time to positivity (TTP) of cultures obtained for periprosthetic joint infection (PJI), thereby assessing its potential to improve diagnostic efficiency and reduce contamination risk. Method. A prospective cohort study was conducted at a tertiary care center, involving 190 patients undergoing revision surgery for PJI from August 2021 to January 2024. Patients were included based on the 2018 International Consensus Meeting definition of PJI. The study utilized a novel sonication protocol, which involved direct intraoperative sonication of the implant and tissue, followed by incubation in a BACT/ALERT 3D system. The primary outcomes measured were the number and percentage of positive culture samples, identified microorganisms, and the TTP of each culture. Statistical analysis was performed using R software, with various tests applied to assess the significance of findings. Results. The study included 510 positive cultures from 190 patients, demonstrating that sonication significantly improved the positivity rate for both tissue and prosthesis specimens (p < 0.05). The median TTP for all samples was 3.13 days, with sonicated samples showing a significantly shorter TTP compared to non-sonicated samples (p < 0.05). Specifically, the shortest median TTP was observed in prosthesis post-sonication samples. Furthermore, the study found that Gram-positive organisms had a shorter TTP than gram-negative organisms, and specific microorganisms like Staphylococcus aureus and MRSE showed the fastest TTP. The analysis also revealed higher positivity rates in chronic PJIs compared to acute PJIs for sonicated tissue samples. Conclusions. The study demonstrates that intraoperative direct sonication combined with the BACT/ALERT 3D system can significantly enhance the diagnostic yield of cultures and reduce the TTP for common PJI pathogens. This novel technique not only improves pathogen detection, facilitating the tailoring of antibiotic therapy, but also potentially reduces the risk of contamination associated with sonication. These findings suggest that direct intraoperative sonication could be a valuable addition to the current diagnostic protocols for PJI, contributing to more effective management and treatment of this complex condition. Further research is necessary to explore the clinical significance of TTP and its correlation with patient outcomes in PJI


Bone & Joint Open
Vol. 1, Issue 7 | Pages 420 - 423
15 Jul 2020
Wallace CN Kontoghiorghe C Kayani B Chang JS Haddad FS

The coronavirus 2019 (COVID-19) global pandemic has had a significant impact on trauma and orthopaedic (T&O) departments worldwide. To manage the peak of the epidemic, orthopaedic staff were redeployed to frontline medical care; these roles included managing minor injury units, forming a “proning” team, and assisting in the intensive care unit (ICU). In addition, outpatient clinics were restructured to facilitate virtual consultations, elective procedures were cancelled, and inpatient hospital admissions minimized to reduce nosocomial COVID-19 infections. Urgent operations for fractures, infection and tumours went ahead but required strict planning to ensure patient safety. Orthopaedic training has also been significantly impacted during this period. This article discusses the impact of COVID-19 on T&O in the UK and highlights key lessons learned that may help to proactively prepare for the next global pandemic. Cite this article: Bone Joint Open 2020;1-7:420–423


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 12 - 12
23 Apr 2024
Jido JT Al-Wizni A Rodham P Taylor DM Kanakaris N Harwood P
Full Access

Introduction. Management of complex fractures poses a significant challenge. Evolving research and changes to national guidelines suggest better outcomes are achieved by transfer to specialist centres. The development of Major Trauma Networks was accompanied by relevant financial arrangements. These do not apply to patients with closed fractures referred for specialist treatment by similar pathways. Despite a surge in cases transferred for care, there is little information available regarding the financial impact on receiving institutions. Materials & Methods. This retrospective study examines data from a Level 1 trauma centre. Patients were identified from our electronic referral system, used for all referrals. Transferred adult patients, undergoing definitive treatment of acute isolated closed tibial fractures, were included for a 2-year period. Data was collected using our clinical and Patient Level Information and Costing (PLICS) systems including coding, demographics, treatment, length of stay (LOS), total operative time, number of operations, direct healthcare costs, and NHS reimbursements. Results. 104 patients were identified, 23 patients were treated by internal fixation and 81 with circular frames. Patients required a median of 190 minutes of total operative time and 6 days of hospital stay at a median cost of £16,233 each, median reimbursement was £10,625. The total cost of treatment for all 104 patients was £2,205,611 and total reimbursement was £1,391463, the median deficit per patient being £5825. The overall deficit over the 2 years was £814,148. Conclusions. This study reveals a considerable economic burden associated with treating complex tibial fractures. It should be emphasised that these do not include patients referred for fracture-related infection or non-union, who may also incur similar deficits in recovered costs. These findings emphasise the importance of understanding and addressing the financial implications of managing tertiary referral orthopaedic trauma patients to ensure efficient and sustainable resource allocation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 93 - 93
1 Apr 2019
Avila C Taylor A Collins S
Full Access

INTRODUCTION. Unlike current acetabular cups, this novel ceramic cup has a Ti/HA coating which removes the requirement for assembly into a metal shell which avoiding potential chipping/misalignment and reducing wall thickness [Figure 1]. This study examines the resistance of novel thin-walled, direct to bone fixation ceramic cups to critical impact loads. METHODS. Samples of the smallest (Ø46mm) and largest (Ø70mm) diameter ReCerf. TM. acetabular cups and corresponding femoral head implants were implanted into Sawbones foam blocks considered representative of pelvic cancellous bone. Two different positional configurations were tested and were considered worst case and the extremes of surgical compromise; P1 simulates the cup fully supported by the acetabulum with a high inclination angle (70°) and a vertical impaction axis (worst case loading near the cup rim) and. P2 simulates the cup implanted with a lower inclination (55°) but with the superior section unsupported by acetabulum bone [Figure 2]. For each size, three acetabular cups were tested in each position. The impact fixture was positioned within a drop weight rig above a bed of sand and ≈22mm of pork belly representative of soft tissues damping effect and the implant components aligned to achieve the defined impact point on the cup [Figure 2]. Lateral falls were tested on all available samples applying impact energy of 140J [1] and 3m/s impact velocity [2]. After the lateral fall test, each sample was tested under impact conditions equivalent to a frontal car crash considering a peak impact force of 5.7kN occurring 40ms from initial contact (able to produce acetabular fracture)[3]. RESULTS. None of the testing simulating a lateral fall produced fracture or any other damage to the ceramic acetabular cup. In 7 of the 12 tests, the impact force was sufficient to fracture the foam block representing the periprosthetic bone. The cups showed a good stability within the blocks, with a maximum recorded cup spinning angle relative to the acetabulum of 4.5˚. Subsequent testing simulating a car crash resulted in the fracture of two samples out of 12, one of the largest and one of the smallest ReCerf. TM. cups. In both instances, failure occurred very close to the inner edge. Of the remaining 10 samples no cup fractures were observed. All foam acetabulum blocks were severely damaged and 5 blocks fractured. The maximum recorded cup spinning angle following the car crash impact was 5.8˚. SIGNIFICANCE. Extreme testing scenarios presented here are not a regulatory requirement for manufacturers and have not previously been considered for ceramic acetabular components. Fracture is a possible failure mode of ceramics but this testing has proven that modern ceramics can withstand lateral falls and the large majority can withstand subsequent loading equivalent to head on car-crash; loading under which pelvic bone fracture and significant injury is far more likely to occur than implant fracture