Objectives. To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing. Main outcome measures. Hip arthroplasty procedures were linked to the time to any subsequent mortality or revision (implant failure). Flexible parametric survival analysis methods were used to analyse time to mortality and also time to revision. Comparisons between procedure groups were adjusted for age, sex, American Society of Anesthesiologists (ASA) grade, and complexity. Results. Multivariable survival analyses identified a higher mortality rate for patients undergoing cemented compared with uncemented total hip replacement (adjusted hazard ratio 1.11, 95% confidence interval 1.07 to 1.16); conversely, there was a lower revision rate with cemented procedures (0.53, 0.50 to 0.57). These translate to small predicted differences in population averaged absolute survival probability at all time points. For example, compared with the uncemented group, at eight years after surgery the predicted probability of death in the cemented group was 0.013 higher (0.007 to 0.019) and the predicted probability of revision was 0.015 lower (0.012 to 0.017). In multivariable analyses restricted to men, there was a higher mortality rate in the cemented group and the uncemented group compared with the Birmingham hip resurfacing group. In terms of revision, the Birmingham hip resurfacings had a similar revision rate to uncemented total hip replacements. Discussion. There is a small but significant increased risk of revision with uncemented rather than cemented total hip replacement, and a small but significant increased risk of death with cemented procedures. It is not known whether these are causal relations or caused by residual confounding. Compared with uncemented and cemented total hip replacements, Birmingham hip resurfacing has a significantly lower risk of death in men of all ages. Previously, only adjusted analyses of hip
Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient,
Introduction. Osseointegration has emerged as a promising alternative to rehabilitating with a traditional socket mounted prosthesis. Advantages have been reported to include improved functional mobility, better osseoperception, improved comfort, reduced pain, better biomechanical alignment and better gait, which all lead to a less restricted lifestyle and significantly improved quality of life. A major concern of the Osseointegrated approach lies in the risk of infections occurring from the permanent transcutaneous opening often referred to as the stoma. Several systematic reviews have indicated that the occurrence of minor infections can be quite common, serious complications are reported to be rare. In addition to commonly anticipated complications including fractures, surgical debridements or revisions, we have identified several significant events in which a patient may require to be readmitted and go through additional surgery. The objective of this study is to examine the rate of occurrence and reports on the best management practices of serious complications across a multi-centre review of more than 1000 osseointegration surgeries. Materials & Methods. A detailed analysis has been performed on all osseointegration surgeries performed by the Osseointegration Group of Australia and it's affiliates between since 2010. The majority of surgeries took place in Australia, the United States, the Middle East as well as in Europe. All events leading to a re-admission and subsequent re-operation have been identified through hospital operation records and pooled together for meta-analysis. Events identified include:
Introduction. Osseointegration has been established as a promising approach for the reconstruction of amputated limbs, particularly for amputees suffering from traditional socket prosthesis (TSP). While Osseointegration was originally developed with a screw fixation design, several Osseointegration devices adopting a modern press-fit design have also been introduced. In this study, medium-term outcomes for patients with the two most common press-fit osseointegration implant used worldwide are analysed. Materials and Methods. This is a cross-sectional analysis containing a cohort of Osseointegration patients treated in several centres worldwide. We analyzed a total of 93 patients with an average follow-up time of 6.52 years. Functional, Mobility and patient reported outcomes were collected pre-operatively and during follow-up. All postoperative adverse events (infection, revision surgery, fractures, and implant failures) were also analyzed. Results. Crude analysis of the data indicated that all 93 patients continue to use their osseointegrated prosthesis. Significant improvements for all outcome measures were observed. However, several adverse events including 19
Introduction. Advantages of osseointegration have been reported to include improved functional mobility, better osseoperception, improved comfort, reduced pain, better biomechanical alignment and gait, which all lead to a less restricted lifestyle and significantly improved quality of life. A major concern of the Osseointegrated approach lies in the risk of infections occurring from the permanent transcutaneous opening often referred to as the stoma. Materials and Methods. Detailed analysis has been performed on all osseointegration surgeries performed by the Osseointegration Group of Australia and it's affiliates since 2010. All events leading to a re-admission and subsequent re-operation have been identified through hospital operation records and pooled together for meta-analysis. Events identified include:
THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for
Background. The duration and extent of postoperative wound leakage after joint arthroplasty in patients with or without a complicated course, like a prosthetic joint infection (PJI), is currently unknown. Adequate differentiation between normal postoperative wound leakage and wound leakage due to a postoperative PJI is important and prevents unnecessary surgical procedures. We investigated the association between postoperative wound leakage and development of PJI in patients who used a previously developed mobile wound care app. Methods. A multicenter, prospective cohort study with patients aged 18 years or older after primary
Chronic extensor mechanism insufficiency around TKA is a very challenging pathology to treat. An insufficient extensor mechanism negatively affects implant survival and patient outcomes. There are several risk factors for extensor mechanism disruption and the surgeon should be aware and avoid these problems in the perioperative period. In appropriately selected patients, reconstruction of the extensor mechanism is a valid option. Whole extensor mechanism and Achilles tendon allograft reconstruction of the deficient extensor mechanism have been proposed with good early published results. These reconstructions, however, are expensive and with time may stretch and lead to recurrence of an extensor lag. An alternative to allograft, is the use of Marlex mesh as popularised by Browne and Hanssen. This technique uses a knitted monofilament polypropylene mesh that is secured to the patient's native lateral tissue and covered by an appropriately dissected and distalised vastus medialis muscle. The technique can be used for both patellar and quadriceps tendon deficiencies and can be done with or without
The interest in osteolysis has waned largely due to the impact of crosslinked polyethylene and the “rarity” of this phenomenon. However, the basic process still remains: particles, motion observed with unstable implants and host specific factors all play a role in bone loss around implants. There are 2 predominant patterns of lysis: Linear versus Expansile. Linear Lysis: is focal bone loss at the interface as seen in the bone cement interface in when using acrylic or at the implant-host interface with porous ingrowth/ongrowth implants. Expansile Lysis: is observed in less contained regions such as the retro- and supra-acetabular regions around the socket. These lesions can also be quite extensive yet may be subtle in appearance. Imaging is essential in identifying the extent and magnitude of osteolysis. Available modalities include plain radiographs although they can be of limited value in that even with oblique views, they often underestimate the degree of bone loss. CT scans are useful but can be limited by artifact. Several centers have explored the role of MRI in assessing lysis. It can be useful for bone loss and provides excellent assessment for soft tissue: abductors, neurovascular structures. Metal artifact reduction sequencing is required to maximise information obtainable. Management of osteolysis: Identification and monitoring periprosthetic osteolysis is a crucial element of patient care. Progressive bone loss leading to loss of fixation and the potential risk for periprosthetic fracture is a real possibility and early recognition and intervention is a priority. The basic Guiding Principles of management are centered around several key elements including the source of osteolysis and degree, the fixation of implant, the location of lysis, the track record of implant system, the presence of patient symptoms (if any), and finally the patient age, activity level, and general health. Specifics of treatment of osteolysis around the acetabulum: With cemented sockets, lysis is typically seen late and frequently at the bone-cement interface. It is often associated with a loose implant and the prime indication for surgery may be pain. Treatment involves implant removal and revision with an uncemented cup and bone grafting or augmentation as needed. With uncemented sockets in the setting of osteolysis, there are several factors to consider. These have been stratified by Rubash, Maloney, and Paprosky. The treatment of these sockets has been summarised as follows: for Type I and Type II with limited lysis, lesional treatment such as debridement and bone grafting with head and polyethylene exchange has been suggested. WATCH for impingement!!!! Graft defects via trap-doors can be performed but make the door big enough to graft. Small doors and grafting through screw holes is at best marginal. In instances of compromised locking mechanisms, consider cementing the liner into the shell. For Type II and Type III
INTRODUCTION. In the United States, the Centers for Medicare and Medicaid Services consider rates of unplanned hospital readmissions to be indicators of provider quality. Understanding the common reasons for readmission following total joint arthroplasty will allow for improved standards of care and better outcomes for patients. The current study seeks to evaluate the rates, reasons, and Medicare costs for readmission after total hip and total knee arthroplasty. METHODS. This study used the Limited Data Set (LDS) from the Centers for Medicare and Medicaid Services (CMS) to identify all primary, elective Total Knee Arthroplasties (TKA) and Total Hip Arthroplasties (THA) performed from January 2013 through June 2016. The data were limited to Diagnosis-Related Group (DRG) 470, which is comprised of major joint replacements without major complications or comorbidities. Readmissions were classified by corresponding DRG. Readmission rates, causes, and associated Medicare Part A payments were aggregated over a ninety-day post-discharge period for 804,448 TKA and 409,844 THA. RESULTS. There were 31,172 readmissions in the ninety days following THA, for a readmission rate of 7.6%. There were 51,768 readmissions following TKA, for a readmission rate of 6.4%. The leading causes of readmission post-THA were revision of hip or knee replacement (17.66%); septicemia (4.76%); and postoperative infections (3.74%). The most common reasons for readmission post-TKA were postoperative infections (6.42%); septicemia (4.84%); and esophagitis (3.85%). In contrast to THA,
Introduction. National Institute for Health and Clinical Excellence (NICE) guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractured neck of femur (NOF) in cognitively intact patients who were independently mobile prior to the injury. The National Joint Registry for England and Wales (NJR) has collected data on THRs performed since 2003. This retrospective cohort study explores risk factors independently associated with implant failure and perioperative mortality. Methods. NJR data recording a THR performed for acute fractured NOF between 2003 and 2010 were analysed. Cox proportional hazards models were used to analyse the extent to which risk of
INTRODUCTION. Historically, the clinical performance of novel implants was usually reported by designer surgeons who were the first to acquire clinical data. Regional and national registries now provide rapid access to survival data on new implants and drive ODEP ratings. To assess implant performance, clinical and radiological data is required in addition to implant survival. Prospective, multi-surgeon, multi-centre assessments have been advocated as the most meaningful. We report the preliminary results of such a study for the MiniHip™femoral component and Trinity™ acetabular component (Corin Ltd, UK). METHODS. As part of a non-designer, multi-surgeon, multi-centre prospective surveillance study to assess the MiniHip™stem and Trinity™ cup, 535 operations on 490 patients were undertaken. At surgery, the average age and BMI of the study group was 58.2 years (range 21 to 76 years) and 27.9 (range 16.3 to 43.4) respectively. Clinical (Harris Hip Score, HHS) and radiological review have been obtained at 6 months, 3 and 5 years. Postal Oxford Hip Score (OHS) and EuroQol- 5D (EQ5D) score have been obtained at 6 months and annually thereafter. To date, 23 study subjects have withdrawn or lost contact, 11 have died, and 9 have undergone revision surgery. By the end of March 2018, 6 month, 1, 2, 3, 4, and 5 year data had been obtained for 511, 445, 427, 376, 296 and 198 subjects respectively. RESULTS.
Endoprosthetic replacement (EPR) is an available option for the management of massive bone loss around failed knee implants. The aim of this study was to determine the results of knee EPRs performed for non-tumour indications. Since 2007, 85 EPRs were performed for in a single tertiary centre by seven surgeons. Mean age at surgery was 73.5 years (range:35–95) with infection as the most common indication (49%), followed by aseptic loosening (18%), complex primary replacement (16%), fracture (15%) and mechanical failure (2%). Mean follow up was 4 years (range:1–9). Functional outcome was determined using the Oxford Knee Score (OKS). At follow-up, 21 patients were deceased and 2 lost to follow-up. Complication rate was 19%. Of the 7 infected cases, 6 were treated with DAIR (debridement, antibiotics, and implant retention) and one underwent above knee amputation. Four of the patients undergoing DAIR were cleared of infection and 2 are on long-term antibiotics. Accounting for
Aim. Diagnosis of periprosthetic joint infection (PJI) is challenging given the limitations of available diagnostic tests. Recently, several studies have shown a role of the long pentraxin PTX3 as a biomarker in inflammatory diseases and infections. This single-center prospective diagnostic study evaluated the diagnostic ability of synovial fluid and serum PTX3 for the infection of total hip arthroplasty (THA) and total knee arthroplasty (TKA). Method. Consecutive patients undergoing revision surgery for painful THA or TKA were enrolled. Patients with antibiotic therapy suspended for less than 2 weeks prior to surgery and patients eligible for metal-on-metal
Background. Periprosthetic joint infection (PJI) after knee arthroplasty surgery remains a serious complication. Yet, there is no international consensus on the surgical treatment of PJI. The purpose was to assess the prosthesis survival rates, risk of re-revision, and mortality rate following the different surgical strategies (1-stage or 2-stage
Dislocation and instability remain leading cause of failure following THA. We present a single-surgeon 10-year experience with use of Dual Mobility (DM) bearings in Primary and Revision THA using posterior approach. 127 DM bearings were implanted between September 2006 – September 2016; 102 in high-risk primary THA's and 25 revision THA's for either treatment or prevention of instability. Selection for DM bearing followed individual patient risk assessment. Criteria for use of DM bearing were presence of multiple risk factors. Mean age was 72.9 years. 100 Mono-block DM implants, 22 Modular DM implants and 5 custom-made DM devices were
Introduction. The precise indications for tibial component metal backing and modularity remain controversial in routine primary total knee arthroplasty. This is particularly true in elderly patients where the perceived benefits of metal backing such as load redistribution and the reduction of polyethylene strain may be clinically less relevant. The cost implications for choosing a metal-backed design over an all-polyethylene design may exceed USD500 per primary knee arthroplasty case. Methods. A prospective randomised clinical trial was carried out at the QEII Health Sciences Centre, Halifax, Nova Scotia, to compare modular metal-backed versus an all-polyethylene tibial component. Outcome measures included clinical range of motion, radiographs, survivorship, Knee Society Clinical Rating System, WOMAC and SF-12. Results. 116 patients requesting primary knee arthroplasty were recruited and randomised between the Smith & Nephew Genesis I non-modular (57) and modular (59) tibial designs between September 1995 and August 1997. At 10 years clinical follow-up, 4
Introduction. Our department is responsible specifically for complex cases resulting from trauma. Our experience does not want to add what has been clearly demonstrated by multicenter studies on the efficacy of rivaroxaban but aims to demonstrate how the use of this molecule was effective also in mega-prosthesis and how it has proven to be flexible and safe in dealing with difficulties and surgical complications more common in such difficult cases. Materials and Methods. From January 2010 to date DVT prophylaxis in THR / TKR and revision was routinely performed with rivaroxaban. To date, in addition to first
The Vancouver classification separates periprosthetic femur fractures after THA into three regions (A - trochanteric, B - around or just below the stem, and C - well below the stem), with fractures around or just below the stem further separated into those with a well-fixed (B1) or loose stem and good (B2) or poor (B3) bone stock. Trochanteric fractures may be associated with osteolysis and require treatment that addresses osteolysis as well as ORIF of displaced fractures. Fractures around a well-fixed stem can be treated with ORIF using cerclage or cable plating, while those around a loose stem require
Introduction. Total hip replacement is one of the most successful orthopaedic surgeries, not least because of the introduction of modular systems giving surgeons the flexibility to intraoperatively adapt the geometry of the artificial joint to the patient's anatomy. However, taper junctions of modular implants are at risk of fretting-induced postoperative complications such as corrosion, which can lead to adverse tissue reactions. Interface micro-motions are suspected to be a causal factor for mechanical loading-induced corrosion, which can require