The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 689 - 695
1 Apr 2021
Jämsä P Reito A Oksala N Eskelinen A Jämsen E

Aims

To investigate whether chronic kidney disease (CKD) is associated with the risk of all-cause revision or revision due to a periprosthetic joint infection (PJI) after primary hip or knee arthroplasty.

Methods

This retrospective cohort study comprised 18,979 consecutive hip and knee arthroplasties from a single high-volume academic hospital. At a median of 5.6 years (interquartile range (IQR) 3.5 to 8.1), all deaths and revisions were counted. To overcome the competing risk of death, competing risk analysis using the cumulative incidence function (CIF) was applied to analyze the association between different stages of CKD and revisions. Confounding factors such as diabetes and BMI were considered using either a stratified CIF or the Fine and Gray model.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. Conclusion. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions. Cite this article: Bone Jt Open 2023;4(2):110–119


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 97 - 102
1 Jan 2025
Smeitink N Schröder FF Dorrestijn O Spekenbrink-Spooren A Govaert LHM Veen EJD

Aims. Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition. Methods. Data from 280 shoulders with 159 primary HAs and 121 TSAs, which were undertaken in patients with atraumatic avascular necrosis of the humeral head between January 2014 and January 2023 from the Dutch Arthroplasty Register (LROI), were included. Kaplan-Meier survival analysis and Cox regression analysis were undertaken. Results. Within four years of follow-up, a total of 15 revisions were required, involving seven HAs (4%) and eight TSAs (7%). This difference was not statistically significant (p = 0.523). Two HAs were revised because of progressive glenoid erosion, and three TSAs were revised for loosening of the glenoid component. The cumulative percentages of revision of HA and TSA were 6% and 8%, respectively (HR 1.1 (95% CI 0.5 to 2.7)). Conclusion. We found no significant difference in short- to mid-term implant survival between the use of a HA and a TSA in the treatment of atraumatic avascular necrosis of the humeral head, without significant glenoid wear. Cite this article: Bone Joint J 2025;107-B(1):97–102


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 71 - 71
1 Dec 2021
Giles W Komperla S Flatt E Gandhi M Eyre-Brook A Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Background/Objectives. The incidence of reverse total shoulder replacement (rTSR) implantation is increasing globally, but apprehension exists regarding complications and associated challenges. We retrospectively analysed the senior author's series of rTSR from a tertiary centre using the VAIOS shoulder system, a modular 4th generation implant. We hypothesised that the revision rTSR cohort would have less favourable outcomes and more complications. Methods. 114 patients underwent rTSR with the VAIOS system, over 7 years. The primary outcome was implant survival. Secondary outcomes were Oxford shoulder scores (OSS), radiographic analysis (scapular notching, tuberosity osteolysis, and periprosthetic radiolucent lines) and complications. Results. There were 55 Primary rTSR, 31 Revision rTSR and 28 Trauma rTSR. Implant survival: Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Average post-operative OSS for the Trauma rTSR was 31.4 Radiological analysis and complications: Low incidence of scapular notching One hairline fracture below the tip of stem, noted incidentally, which required no treatment. One periprosthetic fracture after alcohol related fall. Treated non-surgically One joint infection requiring two-stage revision to rTSR. One dislocation noted at 2 year follow up. This patient had undergone nerve grafting within 6 months of rTSR for axillary nerve injury sustained during the original fracture dislocation. One acromial fracture with tibial and distal humeral fracture after a fall. Conclusions. The 4th generation modular VAIOS implant is a reliable option for various indications. The revision rTSR cohort had favourable outcomes with low complication rates. In this series, early-to-medium term results suggest lower revision rates and good functional outcomes when compared to published reports. We plan to monitor long-term implant survivorship and patient reported outcomes. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 198 - 204
1 Feb 2020
Perlbach R Palm L Mohaddes M Ivarsson I Schilcher J

Aims. This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993. Methods. Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register. Results. Among patients with possible follow-up of ten and 15 years, 152 and 72 patients remained alive without revision of the acetabular component. The number of deaths was 61 and 50, respectively. Of those who died, six patients in each group had a reoperation performed before death. The number of patients with a reoperation was 22 for those with ten-year follow-up and 21 for those with 15 years of follow-up. The Kaplan-Meier implant survival rate for aseptic loosening among all 370 patients in the cohort was 96.3% (95% confidence interval (CI) 94.1 to 98.5) after ten years and 92.8% (95% CI 89.2 to 96.6) after 15 years. Conclusion. Extensive bone impaction grafting combined with uncemented revision components appears to be a reliable method with favourable long-term survival. This technique offers the advantage of bone stock restoration and disputes the long-standing perception that uncemented components require > 50% of host bone contact for successful implant survival. Cite this article: Bone Joint J 2020;102-B(2):198–204


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 152 - 152
1 Sep 2012
Van Der Weegen W Hoekstra H Sybesma T Bos E Schemitsch E Poolman R
Full Access

Background. Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to address these issues. Objective. To evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing arthroplasty (HRA). Method. Electronic databases and reference lists were searched from 1988 to May 2010. Identified abstracts were checked for inclusion or exclusion by two independent reviewers. Data were extracted and summarized by one reviewer and verified by a second reviewer. Main study endpoint was implant survival, which we compared with the National Institute of Clinical Excellence (NICE) benchmark. We also evaluated radiological and functional outcomes, failure modes and other adverse events. The quality of evidence was judged using the Grading of Recommendations Assessment, Development and Evaluation system (GRADE). Results. We identified 539 articles, of which 29 met the inclusion criteria. The studies included one randomised clinical trial, 27 prospective case series and one retrospective case series. Data were extracted from these 29 articles, totalling 10621 resurfaced hips, providing details on five out of 11 resurfacing devices on the market. Mean follow up ranged from 0.6 to 10.5 years and implant survival ranged from 84% to 100%. Of the 10621 hips, 370 were revised (3.5%), with aseptic loosening as most frequent failure mode. None of the HRA implants used to date met the full 10 year NICE benchmark. Thirteen studies showed satisfactory implant survival percentages compared to the three year NICE entry-benchmark. These 13 studies used the BHR implant (eight studies), the Conserve plus (two studies), the Durom implant (one study), the Cormet 2000 implant (one study) or both the McMinn and the BHR implant (one study)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 202 - 202
1 Sep 2012
Van Der Weegen W Hoekstra H Sijbesma T Bos E Schemitsch E Poolman R
Full Access

Introduction. Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing Arthroplasty. Method. Electronic databases and reference lists were searched from 1988 to September 2009. Identified abstracts were checked for inclusion or exclusion by two independent reviewers. Data were extracted and summarized by one reviewer and verified by a second reviewer. Main study endpoint was implant survival, which we compared with the National Institute of Clinical Excellence (NICE) benchmark. We also evaluated radiological and functional outcomes, failure modes and other adverse events. Results. We identified 433 articles, of which 24 met the inclusion criteria. Data were extracted from these 24 articles, totalling 8745 resurfaced hips, providing details on five out of 11 resurfacing devices on the market. Maximum follow up was 9 years, mean follow up ranged from 0.6 to 8 years. Implant survival ranged from 88.7% to 100%. Of the 8745 hips, 276 were revised (3.2%), with fracture of the femoral neck as most frequent failure mode. With implant survival plotted against time, 10 studies showed satisfactory implant survival percentages compared to the 3 year NICE entry-benchmark. Nine of these 10 studies used the BHR implant, the other study used the Cormet 2000 implant. Discussion. None of the HRA implants used to date meet the full 10 year NICE benchmark (≥ 90% survival at 10 years follow up). If follow up is too short for the full benchmark, implants are still recommendable if they meet the NICE three year ‘entry benchmark’ (> 3 year revision rate experience, consistent with the 10-year benchmark). Compared to the 3 year NICE entry-benchmark, 10 studies showed satisfactory implant survival percentages. Nine used the BHR implant, the other study used the Cormet 2000 implant. The quality of evidence is low according to the GRADE classification. Future research has to address the most important failure mode for HRA trying to explain the large variation in the frequency of femoral neck fractures


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims

We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients.

Methods

A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 45 - 45
1 Dec 2017
Glehr M Klim S Sadoghi P Bernhardt G Leithner A Radl R Amerstorfer F
Full Access

Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of metaphyseal sleeve fixation in septic two-stage knee revision surgery. Method. Clinical and radiological follow-up examinations were performed in 49 patients (25 male and 24 female). All patients were treated with a two-stage procedure, using a temporary non-articulating bone cement spacer. The spacer was explanted after a median of 12 weeks (SD 5, min. 1 – max. 31) and reimplantation was performed, using metaphyseal sleeves in combination with stem fixation. Bone defects were classified on preoperative radiographs using the Anderson Orthopaedic Research Institute (AORI) classification. During follow-up postoperative range of motion (ROM) was measured and radiographs were performed to analyse: (i) osseointegration (radiolucent lines and spot welds), (ii) leg alignment, (iii) patella tilt and shift. Results. All types of bone defects were found on the tibial (4× type 1, 7× type 2a, 26× type 2b, 9× type 3) as well as on the femoral side (1× type 1, 4× type 2a, 20× type 2b, 6× type 3). Mean follow-up time was 4.7 years (minimum 1 year). In total 12 knees (24.5%) had to be re-revised, all due to re-infection. We did not encounter any case of aseptic loosening. In 3 patients (6.8%) we detected an insufficient osseointegration, but no patient had to be re-revised due to only minimal or to the absence of symptoms and no clinical signs of loosening. The ROM (mean 93°, SD 20.6, min. 25° max. 125°) has shown very satisfying results at the time of follow-up. Malalignment was detected in 4 patients (10.3%), a patella tilt in 7 (19.4%) and a patella shift in 14 (48.3%). Conclusions. Metaphyseal Sleeves have shown very promising mid-term results regarding osseointegration and aseptic implant survival in RTKA with compromised metaphyseal bone stock. Our results indicate that they are a reliable fixation option in septic RTKA patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 183 - 183
1 Sep 2012
Ruggieri P Pala E Henderson E Funovics P Hornicek F Windhager R Temple T Letson D Mercuri M
Full Access

Introduction. The current investigation includes a retrospective review of the experience of five Institutions with distal femur megaprostheses for tumor over a twenty year period, to analyze the incidence and etiology of failure, using a new classification system based upon the failure modes. Methods. Between 1974 and 2008, 2174 patients underwent primary limb preservation for a benign or malignant extremity tumor using a metallic megaprosthesis at five Institutions, 951 (43.7%) were distal femur replacements. Retrospective analysis of complications according to the Letson and Ruggieri Classification was performed and Kaplan-Meier curves of implant survival were defined. Segmental megaprosthetic reconstruction failures were categorized as mechanical and non-mechanical failures. Results. A total of 951 skeletally mature patients received a segmental endoprosthesis for the treatment of an oncologic condition. Overall 261 (27%) of the primary procedures were considered failures. There were 137 mechanical failures (14.4%): 12 (1.3%) Type 1 (soft tissue failure), 65 (6.8%) Type 2 (aseptic loosening), and 60 (6.3%) Type 3 (structural failure). Non-mechanical causes accounted for 124 failures (13%): 45 (4.7%)Type 4 (tumor progression) and 79 (8.3%) Type 5 (infection). The overall implant survival to all modes of failure was 77% at 10 years and 73% at 20 years. The implant survival to aseptic loosening was over 90% at 10 years. Conclusion. Most frequent cause of failure was infection followed by aseptic loosening and structural failure. The implant survival at long term was quite satisfactory


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims

We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls.

Patients and Methods

This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 55 - 55
22 Nov 2024
Meijer J Soriano A Zijlstra W ten Have B Tarabichi S Jutte P Parvizi J Wouthuyzen-Bakker M
Full Access

Introduction

In recent years, many studies demonstrated the efficacy of an early switch to oral antibiotics after surgical treatment in orthopaedic related infections. However, large analyses on periprosthetic joint infections (PJIs) are lacking.

Material and Methods

We conducted a retrospective observational multicenter study in patients diagnosed with an early postoperative PJI (i.e less than 3 months after the index arthroplasty) treated with debridement, antibiotics and implant retention (DAIR). Patients from Europe and the USA were included. These two cohorts served as a quasi-randomised trial since an early oral antibiotic switch is routine practice in Europe versus a long duration of intravenous (IV) antibiotic treatment in the USA. Failure was defined as the clinical need for: i) a second DAIR, ii) implant removal, iii) suppressive antibiotic treatment or iv) infection related death.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 5 - 5
1 Nov 2016
Drampalos E Karim T Clough T
Full Access

Aim. To examine the mid-term survival, clinical and patient reported outcomes of the silastic 1. st. metatarsophalangeal joint replacement for the treatment of end stage hallux rigidus. Methods. We reviewed 83 consecutive silastic arthroplasties performed in 79 patients for end stage hallux rigidus. There were 3 men and 76 women; mean age 63 years (range 45–78 years). No patient was lost to follow up. Average follow-up was 5.3 years (1.1–11.3 years). The EQ 5D–5L Health index, Manchester-Oxford Foot Questionnaire (MOXFQ), visual analogue scale (VAS) of pain and overall satisfaction rate (Likert scale) were collected for patient reported outcomes. Results. 2 patients required revision; 1 for early infection (2 months) and 1 for stem breakage (10 years 1 month). 5 patients reported lateral metatarsalgia, 2 patients reported neuropathic pain, 6 patients developed superficial infection which fully responded to oral antibiotics, and 1 patient developed interphalangeal joint pain. 2 patients died in the cohort. Pre-operative mean MOXFQ was 44, mean EQ5D Index was 0.564 and VAS was 6.97. At mean follow-up of 5.3 years, the mean MOXFQ was 12.7 (0–57), the mean EQ5D Index was 0.851 (−0.02–1) and the mean VAS was 1.67 (0–8). The mean range of motion was 35° (30° dorsiflexion and 5° plantarflexion). The overall satisfaction rate was 90.2%. The implant survival rate was 97.6%. Conclusions. The silastic big toe arthroplasty offers excellent clinical mid term survival and functional outcomes and could be considered as an attractive alternative to traditional fusion for end stage hallux rigidus


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 452 - 452
1 Jul 2010
Ruggieri P Pala E Ussia G Angelini A Abati CN Calabrò T Pignotti E Casadei R Mercuri M
Full Access

From October 2003 to September 2007 at Rizzoli 161 GMRS. ®. prostheses were implanted after resections of the lower limb. This is a modular system with a knee rotating hinge mechanism, cemented and uncemented stems, in titanium and chromium-cobalt-molybdenum, curved and straight-fluted, with or without hydroxyapatite coating. Adaptors are available to revise HMRS. ®. prostheses with hybrid implants. This study includes 88 males and 73 females ranging in age from 9 to 80 years. Sites of reconstruction were 109 distal femurs, 19 proximal femurs, 1 total femur and 32 proximal tibias. There were 149 oncologic and 12 non oncologic diagnoses, including 96 primary reconstructions and 65 revisions for failures of previous reconstructions. Analysis of imaging and complications was performed and function assessed according to MSTS system. Kaplan-Meier curves were used to statistically evaluate implant survival. At a mean follow up of 2.5 yrs. 106 patients are continuously NED, 31 NED after treatment of relapse, 7 AWD, 5 DWD. There were 10 major complications: 8 infections (4.7%) (5 in primary and 3 in secondary implants) and 2 aseptic loosenings (1.2%) (1 each). There were 9 minor complications requiring minor revisions. Comparative statistical analysis of implant survival showed no statistically significant difference between primary and secondary implants. Functional results were good or excellent in 95% of patients, without any poor. Middle term results are promising with no breakages of implant components. Besides oncological cases, there are selected indications in non oncological settings, such as revisions of prosthetic or allografts failures. While a higher complication rate was expected in secondary implants, statistical analysis shows similar survival


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 119 - 119
1 May 2011
Ruggieri P Pala E Abati C Calabrò T Henderson E Marulanda G Cheong D Letson D Mercuri M
Full Access

Purpose was to evaluate the incidence of complication in lower limb reconstructions with modular prostheses comparing cemented versus uncemented stems in two different orthopedic tumor Centers. Methods: retrospective analysis of implant survival, complications and functional results assessed according to MSTS system of the Rizzoli and Moffitt series of modular megaprosthesis in lower limb. From 2002 and 2007, 238 modular prostheses of same design with a rotating hinge knee, were implanted in the lower limb as primary reconstruction in these two Centers. In 130 cases the prosthesis was implanted with cemented stems and in 108 cases with uncemented stems. Sites included: 120 distal femur, 61 proximal femur, 46 proximal tibia, 10 total femur and in 1 case both distal femur and proximal tibia. Histologic diagnoses included: 89 osteosarcoma, 13 Ewing sarcoma, 21 chondrosarcoma, 19 sarcoma, 55 metastasis, 17 TGC, 7 MFH, 11 other diagnoses and 6 non oncologic cases. Major prostheses-related complications were analysed and functional results according to Muscolo Skeletal Tumor Society system, at a mean follow up of 2.03 yrs. Also a statistical evaluation with Kaplan Meier curves, a comparative statistical analysis with Wilcoxon test and multivariate Cox regression analysis were performed. Results: Outcome in 223 evaluated oncologic pts, showed: 121 pts continuously disease free, 26 NED after treatment of relapse, 54 AWD, 16 DWD. Margins were wide in 94.3% (214/227 pts) of evaluated pts. Complications causing implants failure were: infections in 20/238 (8.41%), aseptic loosening in 7/238 (2.95%). No breakages of prosthetic components were observed. Infections occurred at mean time of 1.3 yrs, sites included: 9 distal femurs, 4 proximal femurs, 5 proximal tibias, 2 total femurs. Aseptic loosening occurred at mean time of 2.3 yrs, sites included: 3 proximal tibias, 2 distal femurs, 2 proximal femurs. Rate of aseptic loosening was higher for cemented stems 5/130 (3.85%) vs uncemented 2/108 (1.85%). This difference is not statistically significant. Infection rate was 10% (13/130) for cemented stems and 6.5% (7/108) for uncemented stems. This difference is statistically significant at comparison of survival curves logrank test. Average MSTS function score was 83.5%. Multivariate Cox regression analysis showed that the significant factor favourable reluted with lower incidence of complications was the use of uncemented stems. Conclusions: lower limb modular prostheses with both cemented and uncemented stems gave good results and a low complication rate. Better results were observed with uncemented stems and statistically confirmed, but this needs to be further investigate in a future study at long term


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1121 - 1126
1 Aug 2013
Núñez-Pereira S Pellisé F Rodríguez-Pardo D Pigrau C Bagó J Villanueva C Cáceres E

This study evaluates the long-term survival of spinal implants after surgical site infection (SSI) and the risk factors associated with treatment failure. . A Kaplan-Meier survival analysis was carried out on 43 patients who had undergone a posterior spinal fusion with instrumentation between January 2006 and December 2008, and who consecutively developed an acute deep surgical site infection. All were appropriately treated by surgical debridement with a tailored antibiotic program based on culture results for a minimum of eight weeks. A ‘terminal event’ or failure of treatment was defined as implant removal or death related to the SSI. The mean follow-up was 26 months (1.03 to 50.9). A total of ten patients (23.3%) had a terminal event. The rate of survival after the first debridement was 90.7% (95% confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95% CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78) at two, three and four years. Four of nine patients required re-instrumentation after implant removal, and two of the four had a recurrent infection at the surgical site. There was one recurrence after implant removal without re-instrumentation. Multivariate analysis revealed a significant risk of treatment failure in patients who developed sepsis (hazard ratio (HR) 12.5 (95% confidence interval (CI) 2.6 to 59.9); p < 0.001) or who had > three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03). Implant survival is seriously compromised even after properly treated surgical site infection, but progressively decreases over the first 24 months. Cite this article: Bone Joint J 2013;95-B:1121–6


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year).

THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 33 - 39
1 Jan 2016
Sabah SA Henckel J Koutsouris S Rajani R Hothi H Skinner JA Hart AJ

Aims

The National Joint Registry for England, Wales and Northern Ireland (NJR) has extended its scope to report on hospital, surgeon and implant performance. Data linkage of the NJR to the London Implant Retrieval Centre (LIRC) has previously evaluated data quality for hip primary procedures, but did not assess revision records.

Methods

We analysed metal-on-metal hip revision procedures performed between 2003 and 2013. A total of 69 929 revision procedures from the NJR and 929 revised pairs of components from the LIRC were included.