Advertisement for orthosearch.org.uk
Results 1 - 20 of 33
Results per page:
Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 119 - 119
1 Mar 2009
DESAI A CHOUDHARY A SHAHI K
Full Access

Aim of the study: to assess the early complication rate following k-wiring of distal radial fractures and their final clinical outcome. Materials & methods: a prospective study. 48 Patients with 50 distal radial fractures (26 male,22 female) with mean age 34 years(range 4–88) were treated by closed k-wiring during the period jan 2005-june 2005. They were assessed in terms of early complications following mua and k-wiring and their final clinical outcome. Results: 12 patients(24%)had discharge, pin tract granulation, loosening out of which 4 required antibiotics. Out of 12 only 2(4%) had positive swab culture requiring i.V. Antibiotics. 3(6%)Had symptoms suggesting superficial radial nerve damage of which 2 recovered completely after pin removal. One had residual symptom which got better before planned exploration. 9 Patients (18%)had stiffness of which only 3(6%)had residual stiffness at the end of 6 months. Crps was noted in 1 patient(2%)who recovered after good physio. There wer nocases of deep infection, osteomyelitis, tendon rupture, pin migration or significant loss of position. Conclusion: our data suggests that though early complication rate of k-wiring is alarming, it doesnot affect the final clinical outcome of fracture management and this complication can be avoided by proper technique and care. There is no rationale in giving antibiotic coverage for all the pintract discharges unless swab positive


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 41 - 41
2 Jan 2024
Singh S Dhar S Kale S
Full Access

The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants.

We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria.

A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics.

Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 107 - 107
1 Jan 2013
Oakley E Sanghrajka A Fernandes J Flowers M Jones S
Full Access

Aim. To investigate the effectiveness of a decision-based protocol designed to minimise the use of medial incisions when performing crossed-wire fixation of supracondylar fractures of the distal humerus whilst minimising ulnar nerve injury. Method. We have employed a protocol for placing the medial wire during crossed k-wire fixation of supracondylar fractures dependent upon the medial epicondyle. When this is palpable, the wire is introduced percutaneously; when it is not, a mini-incision is made. All cases of closed reduction and crossed K-wiring of supracondylar fracture over a three year period (2008–2011) were identified from our department database. Cases with a neurological injury identified pre-operatively, and those in which the protocol had not been followed were excluded. Casenotes were reviewed to determine the incidence and outcomes of post-operative ulnar nerve deficit. Results. A total of 106 cases were identified, from which 36 cases were excluded, leaving 70 cases in the study. The mean age was 5 (range 1–11). 68 were extension-type injuries, of which 29 (41%) were type 2 and 39 (56%) type 3 according to the classification of Gartland. 2 were flexion-type. A mini-incision for placement of the medial K-wire was required in only 3 cases (4.3%), with percutaneous placement in all other cases. There was clinical evidence of partial ulnar nerve injury in 1 case (1.4%) which recovered spontaneously within 11 months. Conclusion. The results of this study demonstrate our protocol to be effective. Careful percutaneous placement of the medial wire can be performed in the majority of cases with little risk of significant or permanent injury to the ulnar nerve. Open placement of the medial wire is indicated in only a small proportion of cases. We suggest that the routine use of a medial mini-incision should be re-considered


Bone & Joint 360
Vol. 14, Issue 1 | Pages 50 - 50
1 Feb 2025


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 333 - 333
1 Jul 2008
Desai AS Mysore SS Choudhary AK
Full Access

Aim of the study: to assess the early complication rate following k-wiring of distal radius fractures and their clinical outcome. A retrospective treatment. METHOD: 48 patients with 50 Distal Radial fractures, number? High velocity (26 Males, 22 Females; Mean age 34 years; Range 4 to 88 years) treated by Closed K-Wiring during the period between January 2005 to June 2005 were assessed in terms of early complications following MUA and K-Wiring and their final outcome. All cases were performed by staff grade or above. 12 patients (24%) had discharge, pin tract granulation, loosening, out of which 4 required antibiotic. Out of 12 only 2 (4%) has positive swab culture requiring Intravenous antibiotics. 3 patients (6%) had symptoms suggesting superficial radial nerve damage of which 2 recovered completely after pin removal. One had residual symptom, put on waiting list but symptoms got better and she refused further treatment. 9 patients (18%) had stiffness out of which only 3 (6%) had residual stiffness at the end of 6 months. However this stiffness can not be attributable to k-wiring alone (?fracture intra articular). CRPS was noted in 1 patient (2%) and recovered after prompt physiotherapy. There were no cases of deep infection, osteomyelitis, tendon rupture, pin migration or significant loss of position in our study. CONCLUSION: Our data suggests that though early complication rate of K-wiring is alarming, it does not affect the final outcome of fracture management; and this complication can be avoided by proper technique and care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 110 - 110
10 Feb 2023
Kim K Wang A Coomarasamy C Foster M
Full Access

Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the headless compression screws (HCS), however there has been no cost analysis to compare the two. Therefore, this study aims to 1) review the cost of DIPJ fusion between k-wire and HCS 2) compare functional outcome and patient satisfaction between the two groups. A retrospective review was performed over a nine-year period from 2012-2021 in Counties Manukau. Cost analysis was performed between patients who underwent DIPJ fusion with either HCS or k-wire. Costs included were surgical cost, repeat operations and follow-up clinic costs. The difference in pre-operative and post-operative functional and pain scores were also compared using the patient rate wrist/hand evaluation (PRWHE). Of the 85 eligible patients, 49 underwent fusion with k-wires and 36 had HCS. The overall cost was significantly lower in the HCS group which was 6554 New Zealand Dollars (NZD), whereas this was 10408 NZD in the k-wire group (p<0.0001). The adjusted relative risk of 1.3 indicate that the cost of k-wires is 1.3 times more than HCS (P=0.0053). The patients’ post-operative PRWHE pain (−22 vs −18, p<0.0001) and functional scores (−38 vs −36, p<0.0001) improved significantly in HCS group compared to the k-wire group. Literatures have shown similar DIPJ fusion outcomes between k-wire and HCS. K-wires often need to be removed post-operatively due to the metalware irritation. This leads to more surgical procedures and clinic follow-ups, which overall increases the cost of DIPJ fusion with k-wires. DIPJ fusion with HCS is a more cost-effective with a lower surgical and follow-up costs compared to the k-wiring technique. Patients with HCS also tend to have a significant improvement in post-operative pain and functional scores


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 262 - 263
1 Mar 2003
Ghoneem H
Full Access

Background: Distal forearm fractures are common in children. Many studies have described high failure rate when treated by closed reduction and immobilization in plaster cast. Loss of reduced position in the cast has been shown to be the most important factor leading to malunion and failure of the treatment. Treating these fractures by closed reduction and percutaneous Kirsch-ner (K-) wiring has been recommended. Objective: This study aims at determining the value of management of distal forearm fractures in children by closed reduction and percutaneous K-wiring in avoiding treatment failure and improving the final outcome. Material and methods: A series of 70 displaced distal forearm fractures in children was studied. These children were randomly allocated to one of two treatment groups: either manipulation and cast alone, or manipulation and percutaneous K-wiring with cast. Both groups were followed up until union occurred. Looking at the incidence of redisplacement, the radiological position at union, and the functional results four months after injury. Results: Redisplacement occurred in 8 out of 35 patients in the cast group (23%), compared to none in the K-wiring group (the difference was statistically significant).The quality of reduction was significantly better in the K-wire group, both initially and at union. Only 59 patients (84%) were reviewed 4 months after injury, none of the children in both groups had functional deficit


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 135 - 135
1 Feb 2012
Kavouriadis V O'Gorman A Bain G Ashwood N
Full Access

Purpose. To elucidate whether there is an advantage in external fixation supplementation of K-wires in comparison to K-wires and plaster, in the treatment of distal radius fractures without metaphyseal comminution. Indications. Distal intraarticular radius fractures, Frykman VIII or VIII without metaphyseal comminution. Contraindications. Metaphyseal comminution, general medical contraindications for surgical intervention. Study design. Fifty-one patients were prospectively randomised in two groups: 24 patients were treated with K-wire and spanning external fixation supplementation, and 27 were treated with K-wires and plaster. Results. Patients were monitored following the operation with a minimum follow up of 1 year, and checked independently of surgeon for pain, satisfaction and range of motion. There was a statistically significant difference in favour of the external fixation patient group for pain (Visual Analogue Score, Ex-Fix group: mean 14.9, plaster group: mean 28.1, p<0.001) and satisfaction (Ex-Fix group: mean 89.7, plaster group: mean 76.3, p<0.001,). Although one would expect that range of motion would be reduced in the external fixation group, there were no statistically significant differences found in favour of plaster; on the contrary supination results were surprisingly in favour of the external fixation group (Ex-Fix group: mean 54.4, plaster group: mean 45.2, p<0.05). Conclusion. In this study, external fixation supplementation of K-wiring had statistically significant superior results in patient satisfaction score, pain score, and wrist supination in comparison to plaster augmentation of K-wiring


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 431 - 431
1 Oct 2006
Barton T Bannister G
Full Access

53 patients underwent closed reduction and longitudinal k-wiring of displaced Colles’ fractures and were reviewed after a mean of 26 months. Radiographs taken at the time of injury, after reduction and k-wiring, and at fracture union were compared for radial shortening and dorsal angulation. Manipulation significantly improved fracture position (p< 0.001). Dorsal angulation was successfully corrected by manipulation in 98%, and this position was maintained to fracture union in all cases. 73% of fractures manipulated for radial shortening > 2mm were adequately reduced, but 41% of these fractures subsequently lost position to malunite. The mean shortening between reduction and fracture union was 1.6mm. This did not correlate with Frykman Class or radial shortening at injury. Closed Reduction and k-wire stabilisation is an attractive technique because it is relatively non-invasive compared with plating or external fixation. However, a degree of radial shortening between reduction and fracture union must be anticipated. Fractures reduced inadequately to allow for this loss of radial length, are more likely to malunite. This may compromise functional outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 73 - 73
1 Mar 2013
Rollinson P Wicks L Kemp M
Full Access

Introduction. A recent retrospective study of distal femoral physeal fractures (DFPFs) suggested closed manipulation alone has a high incidence of re-displacement, malunion or physeal bar formation. The paper concluded that all displaced DFPFs require internal fixation, and breaching the physis with k-wires is safe. We agree that hyper-extension/flexion injuries need stabilisation using k-wires but, in our experience, purely valgus/varus deformities can be successfully managed by manipulation under anaesthesia (MUA) and a moulded cylinder cast. Method. We prospectively observed DFPFs presenting over 12 months. Departmental policy is to treat varus/valgus deformities by MUA, with cylinder casting providing 3 point fixation. Hyper-extension/flexion injuries are reduced on a traction table. 2mm cross k-wiring is performed, leaving the wires under the skin, and a cylinder plaster applied. A post-operative CT scanogram accurately assesses limb alignment. Patients are mobilised immediately using crutches and weight-bearing as pain allows. Plaster and k-wires are removed after 4–5 weeks. Scanogram is then repeated, and again at 6 months and 1 year. Results. 17 cases presented over 1 year. 16 were male, with a median age of 15. 13 were injured playing soccer, 1 in a motor vehicle accident and 3 by other mechanisms. Internal fixation supplemented reduction in 13 cases. 1 patient required repeat MUA and k-wiring when post-operative scanogram identified significant varus mal-alignment. In all cases, cylinder casting was unproblematic and range of movement quickly recovered after plaster/wire removal. To date none have developed significant malunion or growth arrest requiring intervention. Conclusion. DFPFs are uncommon, almost always occurring in teenage males. Accurate reduction and stabilisation is vital to restore and maintain a correct mechanical axis. MUA and cylinder casting is adequate in appropriate cases. Early imaging with CT scanogram can detect mal-alignment. Growth arrest is unusual and unlikely to be significant in most patients, who are approaching skeletal maturity. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 8 - 8
1 Mar 2008
Gadgil A Hayhurst C Maffulli N Dwyer J
Full Access

Reduction and K-wiring is the most popular form of treating displaced supracondylar fractures of the humerus. Complications including redisplacement of the fracture, cubitus varus, iatrogenic nerve injuries and pin tract infection have been reported following surgery. For successful outcome with K-wiring of supracondylar fractures, strict adherence to protocols and surgical expertise are necessary. We have treated these fractures in straight arm traction since 1995, and the purpose of this study was to audit our practice. Between January 1995 and December 2000, 112 children with a closed displaced supracondylar fracture of the humerus, without neurovascular deficit, were managed by straight arm traction for a mean duration of 22 days. Final outcome was assessed using clinical (flex-ion-extension arc, carrying angle and residual rotational deformity) and radiographical (metaphyseal-diaphyseal angle and Humero-Capitellar angle) criteria. Our outcomes were compared with those of the recent large studies reporting results of surgical treatment. 71 (63%) patients had excellent, 33 (29%) patients good, 5 (4.4%) patients fair, and 3 (2.6%) patients poor outcome. All patients with fair or poor outcomes were older than 10 years. Elevated straight-arm traction is safe and effective in children younger than 10 years. It can be effectively used in an environment that has provision of paediatric medical care and general orthopaedic expertise with outcomes comparable to those fractures treated surgically in specialist centres


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 42 - 42
1 Mar 2009
Chambers C Barton T Lane E Bannister G
Full Access

Introduction: Displaced Colles’ fractures are usually managed by closed reduction and cast immobilisation. They are reduced initially but frequently lose position because cast immobilisation is an inefficient means of stabilisation. This results in malunion. If position is lost after reduction and cast immobilisation or the fracture is unstable, closed reduction and cast immobilisation is often supplemented by longitudinal k-wire fixation. There is a paucity of literature examining the incidence of unacceptable malunion after closed reduction and k-wire stabilisation. Aim: The aim of this study was to determine whether closed reduction, longitudinal k-wire fixation and cast immobilisation of displaced fractures of the distal radius avoids unacceptable malunion. A secondary aim was to define the type of fracture best treated by this method. Methods: 53 patients underwent closed reduction and longitudinal k-wiring of displaced Colles’ fractures and were reviewed after a mean of 26 months. Radiographs taken at the time of injury, after reduction and k-wiring, and at fracture union were compared for radial shortening and dorsal angulation. Results: Manipulation significantly improved fracture position (p< 0.001). Dorsal angulation was successfully corrected by manipulation in 98%, and this position was maintained to fracture union in all cases. 73% of fractures manipulated for radial shortening > 2mm were adequately reduced, but 41% of these fractures subsequently lost position to malunite. The mean shortening between reduction and fracture union was 1.6mm. This did not correlate with Frykman Class or radial shortening at injury. Discussion: Closed Reduction and k-wire stabilisation is an attractive technique because it is relatively non-invasive compared with plating or external fixation. However, a degree of radial shortening between reduction and fracture union must be anticipated. Fractures not reduced to allow for this later loss of radial length are more likely to malunite. This may compromise functional outcome


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 286 - 286
1 May 2006
Bahari S Morris S Taylor C Broe D Sparkes J Nicholson P Rice J Mc Elwain J
Full Access

Introduction: The increasing popularity of minimal access surgery in orthopaedic surgery has resulted in increasing use of intra-operative fluoroscopy. The radiation dose received by the surgeon varies from procedure to procedure depending on several factors such as duration of procedure, direct exposure to radiation beam and distance from the radiation source. In particular hand and wrist injuries often involve direct fluoroscopic exposure to the hands of the surgeon and assistant during the procedure. Aim: We undertook a prospective study to directly evaluate the exposure of the surgeon’s and assistant’s hands and thyroid glands during K-wiring procedures of the hand and wrist. In addition we evaluated the efficacy of a lead thyroid shield in limiting the radiation dose to the thyroid gland. In addition we undertook a questionnaire of orthopaedic surgeons and trainees in Ireland to assess the availability of thyroid shields and current practice in wearing them. Method A total of 30 cases were evaluated. Dosimeter film badges (TLD) were obtained from the Radiological Protection Institute of Ireland (RPI). Two dosimeters were worn by each of the surgical team: one on the dorsum of the dominant hand and a second worn on the neck during the procedure. The number of fluoroscopic exposures, number of times that hands were caught in the image field, the total dosage of radiation for the procedure and the length of time of exposure were recorded. In 20 cases the surgical team undertook standard precautions of a lead jacket. In a random selection of 10 cases the surgical team also wore a thyroid shield. Results. The mean dose to the surgical teams’ hands was 1.8 cGy (95% CI + 0.6). The mean dose to the thyroid gland was 0.6 cGy in unprotected cases. Notably the dose to the assistants’ hands was higher though this did not reach statistical approval. In cases in which a thyroid shield was worn a significant decrease in dose was noted (p< 0.05). 35% of surgeons had completed a radiation protection course with junior trainees being less likely to have completed such a course. Conclusion: Significant cumulative radiation dose to the hands and thyroid gland occurs following K-wiring of extremities. The dose to the thyroid gland can be effectively decreased by the use of a thyroid collar. Junior trainees whose operative times and hence radiation exposure are higher, have limited radiation protection training. The mandatory use of thyroid shields and early introduction of radiation protection training may help minimise further radiation exposure


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_11 | Pages 1 - 1
1 Feb 2013
Sanghrajka A Jones S Flowers M
Full Access

Aim. Differing reports about the surgical management of the supracondylar humeral fracture make evidence-based practice very difficult, so knowledge of the contemporary practices and opinions of an expert body can provide a useful benchmark for appraisal; the aim of this study was to obtain this information. Methods. An electronic 18 item, single response multiple-choice questionnaire was designed to investigate various aspects of the surgical management of supracondylar fractures, with particular focus on areas that remain controversial in the literature. Members of BSCOS were invited by email, on three occasions, to complete the questionnaire, which was posted on the web-based SurveyMonkey™ platform (. www.surveymonkey.com. , California, USA). The survey was available for completion for a period of 10 weeks. Results. 102 responses were received (response rate 56.7%); all respondents completed the entire questionnaire. There was almost complete agreement (>90%) in only three areas: -The preferred management of Gartland 3 fractures; The management of the fracture with an absent radial pulse and impaired digital perfusion; An ulnar nerve palsy detected four weeks post-operatively. Majority agreement (>60%) was found regarding: - Possible consequences of delay in performing closed reduction; Management of the pink, perfused hand with an absent radial pulse; Necessity of anatomical reduction. There was no consensus regarding: - K-wiring of Gartland 2 fractures; Management of ulnar nerve palsy detected one week post-operatively; Open insertion of the medial K-wire. Conclusion. Reflecting current trends and attitudes, this survey provides information against which an individual surgeon can appraise their own practice. Strong consensus existed in areas in which clear evidence is available to inform practice. This highlights the importance of good-quality research, and identifies areas requiring further investigation


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 224 - 224
1 Nov 2002
Cheng J Yung S Kw N Lam T
Full Access

Out of a total of 112 children with displaced forearm shaft fracture treated with Percutaneous Kirschner (K) wire fixation in the past 9 years, 84 cases with fracture of both the radius and ulna were reviewed. 64 (76%) had fixation of both the radius and ulna, 10 (12%) the radius only and the other 10 (12%) the ulna only. In 60 (71%) patients were successful with one stage close reduction and pinning, while in the remaining 24 (29%) a semi- open reduction through a small incision was required. The K-wire was inserted through the radial styloid or the Lister tubercle for the radius, and through the tip of the olecranon for the ulna. All the patients reviewed were found to have good functional results with no non-union, deep infection or premature physeal closure at a mean follow-up of 48 months. Initial pre-operative shortening or translation of the fracture were associated with significantly higher chance of open reduction. We concluded that percutaneous K-wiring for forearm diaphyseal fracture in children is a convenient, effective and safe operation, with minimal complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 32 - 32
1 May 2012
O'Meara S Cawley D Kiely P Shannon F
Full Access

Background. Proximal phalangeal fractures are caused by an injury to the dorsum of the hand. This usually causes volar angulation which is unstable when reduced. K-wiring or external fixation can damage the soft tissue envelope, can introduce infection and can loosen or displace. Traction splinting is not well described for these fractures. Objectives. Functional and radiographic assessment of all patients with proximal phalangeal fractures treated with traction splinting. Methods. Theatre records were examined for relevant injuries over a 2 year period. These patients were then assessed using a QuickDASH score, a questionnaire specific to traction splinting and with pre-op, intra-op, post-op and follow-up radiographs. Results. A total of 7 patients were treated with traction splinting, all by the senior author (FJS). Clinical follow was 16 months (range12-20). QuickDASH scores were 0, 0, 0, 0, 0, 2.5, 25/100. With regard to work (n=6), all patients but one scored 0/100 for disability with one patient describing mild work related difficulties. Those participating in sports/performing arts (n=6) scored 0/100. There were no finger-tip pain or numbness issues. Finger length perception was satisfactory in all patients. The splint slipped in 3 patients, secondary to horse riding, showering and through scratching. Two patients reported having a measurable loss of motion in the affected digit (follow-up 18 and 20 months), both with mild functional deficit. Radiographic outcomes showed that traction achieved acceptable length restoration, with no angular deformities. Finger length was maintained in all but one patient who had a shortening of 3.2mm. Conclusions. Traction splinting is a non-invasive, safe and inexpensive method of treating proximal phalangeal fractures. Results of our follow-up study show excellent functional and radiographic outcomes with minimal long term morbidity for this treatment option


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 298 - 298
1 Mar 2004
Achan P Calder P Barry M
Full Access

Aims: To compare the cost of intra-medullary implants used stabilising paediatric diaphyseal fractures with the clinical outcome. Methods: Between March 1994 and August 2001, at two centres, The Womenñs and Childrenñs Hospital, Adelaide, Australia and The Royal London Hospital, London UK 60 children were surgically treated for diaphyseal forearm fractures using Elastic Stable Intramedullary Nails (ESIN) or 2.5mm Kirschner wires. Having established no difference in the clinical outcome or subjective disability of either technique we compared the implant cost directly. Results: The two treatments both resulted in an excellent outcome with all fractures leading to union with no subjective disability. The Kirscner wires cost £3.00 per wire while the ESI Nails cost between £57.50 and £ 113.30 per wire, depending on the dimensions. Conclusions: We were not able to demonstrate any difference in outcome between ESIN and K-Wiring, although the nails do offer theoretical advantages. The cost implications of using the special implant are twenty fold or more, and as the pressures of cost cutting grow, we wonder if theoretical advantage is Òvalue for moneyÒ


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 368 - 368
1 May 2009
Anwar M Khalid M Hamilton D Searle R Sundar M
Full Access

Introduction: Arthrodesis of 1st MTPJ is performed using various fixation techniques including lag screws, dorsal plate and screws, K-wiring. We evaluated the strength of fixation using two staples placed at right angles. Methods: Ten pairs of cadaveric feet were dissected to harvest the hallux MTPJ. Planar cut of articular surfaces using a micro-saggital saw. The bony ends were then approximated with an intervening blade and fixed using 2 staples placed at right angles. The specimen was supported on either ends and subjected to 3 point loading using a materials testing machine (Instron). The load at which the joint opened up sufficiently to let the blade fall was recorded. The load at which the construct failed was then recorded. Results: The joint opened up at an average of 41 Newtons. The load to failure was 130 Newtons. The corresponding average values in kilograms were 4.19 kilograms for the opening of the joint and 12.61 kilograms for the failure of the construct. On full weight bearing using the heel weight bearing shoes that we normally use post-operatively, the forces going through the forefoot were 0 newtons/kilograms, calculated using a TEK SCAN (measures the foot pressure on walking). Conclusion: It is safe to walk patients using a heel weight bearing shoe (Benefoot post op wedge shoe) following 1st MTPJ fusion using staples (uniclip-NewDeal). This is a major advantage compared to other methods of fixation that require plaster cast immobilisation thus reducing inconvenience, plaster expenses and possible complications like DVT


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2010
Ali A Boran S Leonard M Cogley D
Full Access

Introduction: Distal radius metaphyseal fractures in children are not uncommon, but when they occur proximal to the insertion of the pronator quadratus muscle, reduction and maintenance of reduction can be challenging. The deforming forces at the fracture site result in pronation and shortening of the distal fragment. Manual manipulation of this fracture often results in tearing of the dorsal periosteum and hence renders this fracture highly unstable. Aim: We present a novel easily reproducible mini-open surgical technique and functionally and radiologically evaluate a series of eleven patients who have undergone this technique. Materials and Methods: The surgical technique consists of a mini-open intrafocal image intensifier guided reduction technique with percutaneous k-wiring fixation. Five males and six females with an average age of 8.8 years (range 5 to 13 years), who sustained a pronator quadratus distal radius fracture and subsequently underwent this surgical technique from 2005 to 2007, were evaluated both radiologically in terms of radial length, radial tilt and volar tilt compared with the contralateral limb and functionally using the Mayo Modified wrist score and the patient related wrist evaluation questionnaire. Results: Patients were followed up for an average of 18 months (range 2–31 months). All patients achieved clinical and radiological union. No patient required remanipulation for loss of reduction. Radiological outcome measures similar to contralateral limb with good functional scores. No complications were noted. All patients returned to preoperative level of function. Conclusion: This minimally invasive technique has been shown to be technically easy, reliable and reproducible with excellent results and low risk of displacement compared to other techniques used to treat this potentially challenging fracture


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 286 - 286
1 Mar 2004
Himanshu S Taylor G Clarke N
Full Access

Aims: There are no large published studies examining the complication rates associated with use of Kirschner wires in þxation of a wide variety of paediatric fractures. The aim of this study is to analyse the outcomes of fracture þxation using K-wire in upper limb fractures in children and to critically assess the incidence and type of complications. Methods: This study is a retrospective review of a consecutive series of 107 fractures in 105 paediatric trauma cases treated with K-wire in between 01.09.99 to 10.09.01. Results: The fractures were fractures around Wrist (47%) and around elbow (45%). 66 (61.68%) were performed by closed percutaneous technique, 27 (25.23%) by open method and in 14 (13.08%) combined approach was used. Around there were 13 cases with over-granulation at wound site, 6 cases of Soft tissue infection, 2 cases with tendinitis, 1 case of Osteo-myelitis and 1 case with hyper-sensitive scar. 3 cases found to have postoperative neurapraxia and 1 case with axonotmesis. Metal migration was detected in 4 cases and 14 cases found to have shown wire loosening. 10 fractures have lost position in postoperative period out of which 2 cases were reoperated for Re K-wire, 1 had undergone Re-MUA and 7 left for remodelling. Conclusions: K-wires are versatile but are not inherently benign. We conclude that best results could be achieved if total life of K-wire can be restricted to 3–4 weeks. We recommend one should explain all these risks and complications during consenting for K-wiring procedures