Background. There is a paucity of long term data concerning the pre and postoperative patient reported function of total knee replacement. The aim of this study was to determine the mortality, implant survivorship, patient reported function and satisfaction in a cohort of 114 patients, from a single centre, who received a
Summary Statement. Using current analysis/methodology, new implant technology is unlikely to demonstrate a large enough change in patient function to impact on the cost-effectiveness of the procedure. Purpose. Cost effectiveness is an increasingly important metric in today's healthcare environment, and decisions surrounding which arthroplasty prosthesis to implant are not exempt from such health economic concerns. Quality adjusted life years (QALYs) are the typical assessment tool for this type of evaluation. Using this methodology, joint arthroplasty has been shown to be cost effective, however studies directly comparing the QALY achieved by differing prostheses are lacking. Methods. Data was gathered in a single centre prospective double-blind randomised controlled trial comparing the outcome a modern implant, the Triathlon total knee replacement, with its traditionally designed predecessor the
One of the main surgical goals when performing a total knee replacement (TKR) is to ensure the implants are properly aligned and correctly sized; however, understanding the effect of alignment and rotation on the biomechanics of the knee during functional activities is limited. Cardiff University has unique access to a group of local patients who have relatively high frequency of poor alignment, and early failure. This provides a rare insight into how malalignment of TKR's can affect patients from a clinical and biomechanical point of view to determine how to best align a TKR. This study aims to explore relationship clinical surgical measurements of Implant alignment with in-vivo joint kinematics. 28 patient volunteers (with 32
End-stage osteoarthritis is characterised by pain and reduced physical function, for which total knee arthroplasty (TKA) is recognised to be a highly effective treatment. Most implants are multi radius in design, though modern kinematic theory suggests a single flexion/extension axis is located in the femur. A recently launched TKA implant (Triathlon, Stryker US), is based on this theory, adopting a single radius of curvature femoral component. It is hypothesised that this design allows better function, and specifically, that it results in enhanced efficiency of the quadriceps group through a longer patello-femoral moment arm. Change in power output was compared between single and multi radius implants as part of a larger ongoing randomised controlled trial to benchmark the new implant. Power output was assessed using a Leg Extensor Power Rig, well validated for use with this population, pre-operatively and at 6, 26 and 52 weeks post-operatively in 101 Triathlon and 82
Previous research has shown an increase in chromosomal aberrations in patients with worn implants. The type of aberration depended on the type of metal alloy in the prosthesis. We have investigated the metal-specific difference in the level of DNA damage (DNA stand breaks and alkali labile sites) induced by culturing human fibroblasts in synovial fluid retrieved at revision arthroplasty. All six samples from revision cobalt-chromium metal-on-metal and four of six samples from cobalt-chromium metal-on-polyethylene prostheses caused DNA damage. By contrast, none of six samples from revision stainless-steel metal-on-polyethylene prostheses caused significant damage. Samples of cobalt-chromium alloy left to corrode in phosphate-buffered saline also caused DNA damage and this depended on a synergistic effect between the cobalt and chromium ions. Our results further emphasise that epidemiological studies of orthopaedic implants should take account of the type of metal alloy used.